全文获取类型
收费全文 | 126篇 |
免费 | 22篇 |
国内免费 | 25篇 |
专业分类
测绘学 | 7篇 |
大气科学 | 2篇 |
地球物理 | 48篇 |
地质学 | 68篇 |
海洋学 | 34篇 |
综合类 | 8篇 |
自然地理 | 6篇 |
出版年
2023年 | 2篇 |
2022年 | 4篇 |
2021年 | 4篇 |
2020年 | 1篇 |
2019年 | 4篇 |
2018年 | 5篇 |
2017年 | 8篇 |
2016年 | 4篇 |
2015年 | 7篇 |
2014年 | 4篇 |
2013年 | 10篇 |
2012年 | 8篇 |
2011年 | 12篇 |
2010年 | 9篇 |
2009年 | 5篇 |
2008年 | 11篇 |
2007年 | 12篇 |
2006年 | 13篇 |
2005年 | 7篇 |
2004年 | 5篇 |
2003年 | 6篇 |
2002年 | 3篇 |
2001年 | 3篇 |
2000年 | 5篇 |
1999年 | 5篇 |
1998年 | 2篇 |
1997年 | 3篇 |
1995年 | 2篇 |
1994年 | 1篇 |
1993年 | 2篇 |
1992年 | 2篇 |
1989年 | 2篇 |
1985年 | 2篇 |
排序方式: 共有173条查询结果,搜索用时 16 毫秒
1.
Roberto Mínguez Fernando Delgado Ignacio Escuder Manuel G. de Membrillera 《国际地质力学数值与分析法杂志》2006,30(10):1019-1037
Empirical criteria have been used successfully to design filters of most embankment large dam projects throughout the world. However, these empirical rules are only applicable to a particular range of soils tested in laboratory and do not take into account the variability of the base material and filter particle sizes. In addition, it is widely accepted that the safety of fill dams is mainly dependent on the reliability of their filter performance. The work herein presented consists in a new general method for assessing the probability of fulfilling any empirical filter design criteria accounting for base and filter heterogeneity by means of first‐order reliability methods (FORM), so that reliability indexes and probabilities of fulfilling any particular criteria are obtained. This method will allow engineers to estimate the safety of existing filters in terms of probability of fulfilling their design criteria and might also be used as a decision tool on sampling needs and material size tolerances during construction. In addition, sensitivity analysis makes possible to analyse how reliabilities are influenced by different sources of input data. Finally, in case of a portfolio risk assessment, this method will allow engineers to compare the safety of several existing dams in order to prioritize safety investments and it is expected to be a very useful tool to evaluate probabilities of failure due to internal erosion. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
2.
This paper is aimed towards investigating the filtration law of an incompressible viscous Newtonian fluid through a rigid non-inertial porous medium (e.g. a porous medium placed in a centrifuge basket). The filtration law is obtained by upscaling the flow equations at the pore scale. The upscaling technique is the homogenization method of multiple scale expansions which rigorously gives the macroscopic behaviour and the effective properties without any prerequisite on the form of the macroscopic equations. The derived filtration law is similar to Darcy's law, but the tensor of permeability presents the following remarkable properties: it depends upon the angular velocity of the porous matrix, it verifies Hall–Onsager's relationship and it is a non-symmetric tensor. We thus deduce that, under rotation, an isotropic porous medium leads to a non-isotropic effective permeability. In this paper, we present the results of numerical simulations of the flow through rotating porous media. This allows us to highlight the deviations of the flow due to Coriolis effects at both the microscopic scale (i.e. the pore scale), and the macroscopic scale (i.e. the sample scale). The above results confirm that for an isotropic medium, phenomenological laws already proposed in the literature fails at reproducing three-dimensional Coriolis effects in all types of pores geometry. We show that Coriolis effects may lead to significant variations of the permeability measured during centrifuge tests when the inverse Ekman number Ek−1 is 𝒪(1). These variations are estimated to be less than 5% if Ek−1<0.2, which is the case of classical geotechnical centrifuge tests. We finally conclude by showing that available experimental data from tests carried out in centrifuges are not sufficient to determining the effective tensor of permeability of rotating porous media. Copyright © 2004 John Wiley & Sons, Ltd. 相似文献
3.
Estimating hydraulic conductivity using grain-size analyses, aquifer tests, and numerical modeling in a riverside alluvial system in South Korea 总被引:2,自引:0,他引:2
Jae-Yeol Cheong Se-Yeong Hamm Hyoung-Soo Kim Eun-Joung Ko Kyounghee Yang Jeong-Hwan Lee 《Hydrogeology Journal》2008,16(6):1129-1143
Hydraulic conductivity (K) for an alluvial system in a riverbank filtration area in Changwon City, South Korea, has been studied using grain-size distribution, pumping and slug tests, and numerical modeling. The alluvial system is composed of layers: upper fine sand, medium sand, lower fine sand, and a highly conductive sand/gravel layer at the base. The geometric mean of K for the sand/gravel layer (9.89?×?10?4 m s?1), as determined by grain-size analyses, was 3.33 times greater than the geometric mean obtained from pumping tests (2.97?×?10?4 m s?1). The geometric mean of K estimates obtained from slug tests (3.08?×?10?6 m s?1) was one to two orders of magnitude lower than that from pumping tests and grain-size analyses. K estimates derived from a numerical model were compared to those derived from the grain-size methods, slug tests and pumping tests in order to determine the degree of deviation from the numerical model. It is considered that the K estimates determined by the slug tests resemble the uppermost part of the alluvial deposit, whereas the K estimates obtained by grain-size analyses and pumping tests are similar to those from the numerical model for the sand/gravel layer of the riverside alluvial system. 相似文献
4.
Lake bank filtration at Nainital,India: water-quality evaluation 总被引:6,自引:2,他引:4
There are different water-supply schemes in Uttarakhand, India to tap the water from streams, rivers and lakes. At Nainital,
seven tube-wells (depths 22.6–36.7 m), located at a distance of <100 m from the lake, are being used to abstract (1) lake
water after passage through the soil and (2) subsurface water/groundwater flowing towards the lake. Water samples from the
lake and tube-wells were analyzed in monsoon and non-monsoon periods from 1997 to 2006. Total dissolved solids, EC, alkalinity
and hardness were found to be marginally greater in tube-well waters. The difference in hydrochemistry of tube-well water
was mainly due to variation in flow regimes during monsoon and non-monsoon periods. Results clearly indicate that lake water
as such is not potable as it contains unacceptable levels of organic matter in terms of COD (~44 mg/L), coliforms (~15.6 × 104 MPN/100 mL) and nutrients. Coliform bacteria and COD have not been detected in any of the tube-well water samples over the
years. Lake water, treated by sand filters did not conform to drinking water standards. These investigations have led to the
closure of the treatment facility and installation of two tube-wells in addition to the existing five tube-wells.
Résumé Il existe divers projets d’alimentation en eau dans l’état d’Uttarakhand, Inde, afin de capter l’eau de ruisseaux, de rivières et de lacs. A Nainital, sept puits tubés (profondeur de 22.6–36.7 m), situés à une distance < à 100 m du lac, sont utilisés pour prélever (1) de l’eau du lac après transit à travers le sol et (2) de l’eau de sub-surface/eau souterraine s’écoulant vers le lac. Des échantillons d’eau du lac et des puits tubés ont été analysés en périodes de mousson et de celles sans mousson 1997 à 2006. Résidu sec, C.E., alcalinité et dureté ont été trouvés marginalement supérieurs dans l’eau des puits tubés. La différence d’hydrochimie de l’eau des puits tubés était surtout due à la variation des régimes d’écoulement pendant les périodes de mousson et de celles sans mousson. Les résultats indiquent clairement que l’eau du lac en tant que telle n’est pas potable car elle contient des teneurs inacceptables de matière organique en termes de COD (~44 mg/L), de coliformes (~15.6 × 104 MPN/100 mL) et d’éléments nutritifs. Des bactéries coliformes et du COD n’ont été détectés dans aucun des échantillons d’eau de puits tubés au fil des années. L’eau du lac traitée par des filtres à sable ne se conformait pas aux normes de l’eau potable. Ces recherches ont conduit à la fermeture de l’installation de traitement et à l’implantation de deux puits tubés en plus des cinq puits existants.
Resumen En el estado de Uttarakhand, India, existen diferentes esquemas de abastecimiento de agua que explotan agua de arroyos, ríos y lagos. En Nainital, siete pozos (profundidades entre 22.6–36.7 m), ubicados a una distancia de <100 m del lago, se usan para extraer (1) agua del lago luego de su pasaje a través del suelo y (2) agua superficial y subterránea que fluye hacia el lago. En períodos de monzón y de no monzón de 1997 a 2006 se han analizado muestras de agua del lago y de las captaciones. Se halló que el agua de los pozos es ligeramente mayor en términos del total de sólidos disueltos, la conductividad eléctrica, la alcalinidad y la dureza. La diferencia en la hidroquímica del agua de las perforaciones se debe principalmente a la variación de los regímenes de flujo durante los períodos de monzón y de no monzón. Los resultados claramente indican que el agua del lago no es potable por su contenido inaceptable de materia orgánica medida como demanda de carbono orgánico/oxígeno –DCO- (~44 mg/L), coliformes (~15.6 × 104 NMP/100 mL) y nutrientes. En el período, no se han detectado bacterias coliformes ni DCO en las muestras de agua de las captaciones. El agua del lago, tratada con filtros de arena, no conformó los estándares de agua para bebida. Estas investigaciones han demostrado la necesidad de clausurar las instalaciones de tratamiento y la adición de dos captaciones a las cinco ya existentes.相似文献
5.
Preparation of filter aids based on diatomites 总被引:1,自引:1,他引:1
Sanja Martinovic Milica Vlahovic Tamara Boljanac Ljubica Pavlovic 《International Journal of Mineral Processing》2006,80(2-4):255-260
Two major deposits of diatomaceous earth (diatomite) in the region of the Balkan Peninsula, the Kolubara basin (Serbia and Montenegro) and the Vesje deposit (Former Yugoslav Republic of Macedonia), were selected for detailed investigation of their possible application in preparation of beer filter aids. Chemical, mineralogical and structural properties of diatomite samples were analyzed with the aim of predicting the filtration efficiency. Results of beer filtering compounds preparation are presented in this paper. The parameters of crushing, drying, calcination and classification are also defined. Beer filtration tests proved diatomites to be satisfactory and not causing any degradation of filtration process or beer quality. Technological flow scheme for obtaining the beer filter aids is proposed in the paper. 相似文献
6.
7.
8.
基于Barnes滤波原理的降水场客观分析及尺度分离 总被引:4,自引:0,他引:4
基于Barnes滤波原理(又称高斯加权客观分析),在进行网格点插值的同时,通过选择适当的滤波参数C、G滤去原始场中的短波噪音,使分析结果平稳光滑;另外可通过它构成一带通滤波器,根据实际需要分离出影响天气过程的各种次天气尺度,达到尺度分离的目的。以全国160个国家基准代表站1954—2006年共53a的年平均降水场为例作实例分析,并同用Grads内插函数(Oacres函数)、九点平滑函数(Smth9函数)的绘图结果进行对比分析,结果表明客观分析结果同Grads内插平滑分析结果基本相似,都能反映出我国53a年平均降水场从东南向西北逐渐递减的趋势且与实际情况相符,降水场高值中心位于长江流域及以南的华南等地区,低值中心位于黄河流域以北的广大西部地区。取不同的参数C和G得到的尺度分离后的带通滤波值,既抑止了长波,又抑制了短波,达到较好的尺度分离效果。 相似文献
9.
10.
盐度对长江口3种滤食性贝类滤水率、摄食率、同化率的影响 总被引:2,自引:2,他引:2
采用实验生态学方法研究了盐度对长江口缢蛏(Sinonovacula constricta)、河蚬(Corbicula fluminea)和光滑河蓝蛤(Potamocorbula laevis)滤水率、摄食率、同化率的影响。缢蛏组设6个盐度梯度(5,10,15,20,25,30),光滑河蓝蛤组设6个盐度梯度(5,10,15,20,25,30),河蚬组设6个盐度梯度(0,5,10,15,20,25),并测定了此3种滤食性贝类的生物学参数。结果显示,3种滤食性贝类的滤水率、摄食率和同化率随着盐度的上升而增加,当上升到一定盐度时达到峰值,然后随着盐度的升高而降低。盐度20时,缢蛏滤水率、摄食率和同化率达到峰值,分别为0.57L/h、5.38mg POM/h和0.72%。盐度10时,光滑河蓝蛤滤水率和同化率达到峰值,分别为0.46L/h和0.53%,摄食率在盐度15时达到峰值3.80mg POM/h。盐度5时河蚬滤水率和摄食率都达到峰值,分别为0.39 L/h和2.48 mg POM/h,同化率在盐度0时已达到峰值0.51%,并随盐度上升而下降。上述结果表明,盐度对3种滤食性贝类的3个摄食生理指标均有显著影响。 相似文献