首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   0篇
  国内免费   5篇
测绘学   1篇
大气科学   2篇
地球物理   8篇
地质学   16篇
  2022年   1篇
  2021年   1篇
  2020年   2篇
  2017年   2篇
  2014年   2篇
  2013年   2篇
  2012年   1篇
  2011年   1篇
  2010年   3篇
  2008年   3篇
  2007年   1篇
  2006年   1篇
  2004年   1篇
  2001年   1篇
  2000年   1篇
  1997年   1篇
  1991年   1篇
  1990年   1篇
  1985年   1篇
排序方式: 共有27条查询结果,搜索用时 0 毫秒
1.
2.
This study focuses on the three‐dimensional (3‐D) characteristics of wave propagation in pipe‐pile using elastodynamic finite integration technique. First, a real 3‐D pile‐soil model in cylindrical coordinate system is presented. Then, the governing equations are established. With the boundary and initial conditions, the numerical solution is obtained. The accuracy and feasibility of the self‐written code are further verified via comparing with the measured data. Velocity histories at different angles of pile top and pile tip are illustrated, and the snapshots reflecting the 3‐D characteristics of wave propagation are given. It shows that the interferences of Rayleigh waves can confuse the result interpretation for pile integrity testing. The increase of hammer contact time can effectively mitigate the interferences, and the interferences of Rayleigh waves are weakest at an angle of 90° from where hammer hits. Besides, surrounding soil can partly mitigate the wave interferences. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
3.
为实现北洺河铁矿不明涌水异常区域导水通道的精确定位,保证该矿安全生产,采用矿井瞬变电磁法对该铁矿-110 m水平11#穿脉顶板岩层进行了探测。在对金属干扰下的矿井瞬变电磁响应特征进行理论分析的基础上,结合该铁矿实际地质情况分析其地球物理特征,采用系数校正法对实测数据进行金属干扰校正,再将其作为初始模型进行全空间瞬变电磁蜂群算法反演处理,最终得到了工作面顶板高分辨率电阻率成像结果,结合已有地质资料,实现了富水异常区以及导水通道的精细探测;探测结果得到了钻孔验证。研究表明,采用有效的数据处理手段,矿井瞬变电磁法可以提高铁矿工作面顶板岩层的富水异常位置的探测精度,为铁矿防治水工作提供有效的技术保障。  相似文献   
4.
对数字形变观测过程中辽宁丹东地震台、营口地震台、抚顺地震台、朝阳地震台DSQ水管仪、SS-Y伸缩仪存在的自然干扰现象进行研究,对其机理和数据形态作了对比分析,为快速、准确地判别自然干扰提供了科学依据。  相似文献   
5.
GPS接收机的信号通常很微弱,很容易受到有意或无意的干扰。对于线性调频干扰,在GPS接收机中很难用单一的时域或频域方法消除,因为线性调频干扰不同于一般的宽带或窄带干扰。另外线性调频干扰在变换域有不同于GPS C/A码的显著特征,基于此特点设计了一种在变换域抑制线性调频干扰的GPS接收机。分析了线性调频干扰在变换域的特征,仿真结果验证了这种设计方法的可行性。  相似文献   
6.
铁同位素的MC-ICP-MS测定方法与地质标准物质的铁同位素组成   总被引:17,自引:5,他引:17  
详细报道了在低分辨和高分辨模式下运用MC-ICP-MS进行Fe同位素比值高精度测试的方法,对Fe同位素测定过程中谱峰干扰、基质效应、浓度效应、仪器测试的长期重现性等问题进行了评估,并对两种运行模式的测试结果进行了对比.在95%的可信度范围内,所建方法的外部精度优于0.5ε/ainu,达到国际同类实验室的先进水平,并且低分辨和高分辨两种模式下获得的Fe同位素测试结果是一致的.在此基础上对国家地质标准物质GBW07105(玄武岩)和GBW 07111(花岗闪长岩)进行了Fe同位素测定.相对于Fe同位素国际标样IRMM-014,GBW07105的Fe同位素成分为:ε57Fe=1.9±0.3(20),ε56Fe=1.3±0.2(2σ),ε57/56Fe=0.6±0.1(2σ);GBW 07111的Fe同位素成分为:ε57Fe=1.8±0.4(2σ),ε56Fe=1.2±0.2(2σ),ε57/56Fe=0.6±0.1(2σ).  相似文献   
7.
刘宜铬 《铀矿地质》1990,6(1):41-47
为了发挥航测仪器的性能和提高测量精度,用于航空放射性测量的飞机必须进行必要的改装,改装工作除了保证航测仪器安装可靠、牢固之外,还要使飞机对仪器的磁干扰,放射性干扰和电干扰降低到允许的水平。本文对运五和运十二飞机存在的干扰情况进行了讨论,并就如何消除这些干扰提出了切合实际的改装方案。  相似文献   
8.
A detector for the chemiluminescent measurement of NO in background air is described. A large reduction of interferences is achieved by using a stabilized ozone generator which allows operation of the instrument at lower O3 concentrations. Purification and humidification of the O3 stream further reduces interferences and shortens the instrumental clean-up time, which is important for aircraft missions. From a series of laboratory tests and from measurements performed aboard an aircraft it is demonstrated that the remaining interferences are acceptable for measurements in the undisturbed troposphere. In particular, no remnant NO signal is observed in clean air at night. During flight, a detection limit (2) of 20 ppt is achieved for a 1 min integration time.  相似文献   
9.
This review describes significant developments in trace element determination using inductively coupled plasma-atomic emission spectrometry (ICP-AES) and inductively coupled plasma-mass spectrometry (ICP-MS) that were reported in 2004 and 2005. It focuses on the application of ICP techniques to geological and environmental samples; fundamental studies in ICP-MS and ICP-AES instrumentation are not included. The literature reviewed indicated that the majority of new publications concerned advances in ICP-MS analysis rather than ICP-AES. However, ICP-AES developments are still being published, particularly in the areas of sample preconcentration and sample introduction. The trend in increasing publication of developments in hyphenated speciation techniques looks set to persist as knowledge of elemental speciation becomes critical for many environmental studies. Collision or reactions cells were the most reported technique for spectral interference removal in ICP-MS, probably reflecting the growing adoption of cell instruments in laboratories during the last few years.  相似文献   
10.
This review describes developments in trace element determination using inductively coupled plasma‐atomic emission spectrometry (ICP‐AES) and inductively coupled plasma‐mass spectrometry (ICP‐MS) that were reported in 2006 and 2007. It focuses on the application of ICP techniques to geological and environmental samples; fundamental studies in ICP‐MS and ICP‐AES instrumentation have largely been ignored. New advances in ICP‐MS and ICP‐AES were incremental over this period, partly because both techniques are now well‐established. A continuing shift towards the hyphenation of low‐flow separation techniques has sparked activity in the development of appropriate low‐flow interfaces, and papers discussing interference removal also contribute significantly to the volume of research for both ICP‐AES and ICP‐MS. Whereas the majority of new ICP publications concerned advances in ICP‐MS analysis rather than ICP‐AES, development for ICP‐AES still occurs in almost all areas, particularly in sample introduction and hyphenated techniques.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号