首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   6篇
  国内免费   1篇
地球物理   28篇
海洋学   1篇
  2020年   1篇
  2018年   2篇
  2017年   2篇
  2016年   1篇
  2015年   1篇
  2014年   6篇
  2013年   1篇
  2011年   1篇
  2009年   1篇
  2008年   1篇
  2006年   2篇
  2005年   1篇
  2004年   1篇
  2003年   3篇
  2002年   2篇
  2001年   1篇
  2000年   1篇
  1998年   1篇
排序方式: 共有29条查询结果,搜索用时 31 毫秒
1.
Comparative study of the inelastic response of base isolated buildings   总被引:1,自引:0,他引:1  
This article presents a numeric comparative study of the inelastic structural response of base isolated buildings. The comparative study includes the following isolation systems: laminated rubber bearings, New Zealand one, pure friction and the frictional pendulum ones. The study is based on obtaining non‐linear response spectra for various design parameters using six earthquake records. Usually the base isolation of a new building seeks to maintain the structure in the linear elastic range. The response of old weak buildings or the response of new ones subjected to extreme earthquakes may not be, necessarily, in the aforementioned ideal elastic range. Consequently, it is important to characterize the response of isolated buildings responding inelastically. A conclusion from this research is that the isolators affect significantly the structural response of weak systems. Rubber isolators seem slightly less sensitive to plastification that may occur in the structure compared to friction isolators. Ductility demands in the structure are affected significantly by friction and neoprene protected systems, in particular sliding ones where larger demands are obtained. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   
2.
Seismic tests have been conducted on two 3‐storey structures protected with pressurized fluid‐viscous spring damper devices. One of the structures was a reinforced concrete frame with clay elements in the slabs, while the other one was a steel frame with steel/concrete composite slabs. The spring dampers were installed through K bracing in between the floors. The tests were performed by means of the pseudodynamic method, which allowed the use of large and full‐size specimens, and by implementing a specific compensation strategy for the strain‐rate effect at the devices. The test results allowed the verification of the adequacy of the attachment system as well as the comparison of the behaviour of the unprotected buildings with several protected configurations, showing the benefits of the application of the devices and the characteristics of their performance. The response of the protected structures was always safer than that of the unprotected ones mainly due to a significant increase of equivalent damping. The increase in the damping ratio depends on the level of deformation. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   
3.
An effective strategy of seismic retrofitting consists of installing nonlinear viscous dampers between the existing building, with insufficient lateral resistance, and some auxiliary towers, specially designed and erected as reaction structures. This allows improving the seismic performance of the existing building without any major alteration to its structural and nonstructural elements, which makes this approach particularly appealing for buildings with heritage value. In this paper, the nonlinear governing equations of the coupled lateral‐torsional seismic motion are derived from first principles for the general case of a multistory building connected at various locations in plan and in elevation to an arbitrary number of multistory towers. This formulation is then used to assess the performance of the proposed retrofitting strategy for a real case study, namely, a 5‐story student hall of residence in the city of Messina, Italy. The results of extensive time‐history analyses highlight the key design considerations associated with the stiffness of the reaction towers and the mechanical parameters of the nonlinear viscous dampers, confirming the validity of this approach.  相似文献   
4.
An innovative solution for the seismic protection of existing masonry structures is proposed and investigated through shake table tests on a natural scale wall assemblage. After a former test series carried out without reinforcement, the specimen was retrofitted using Steel Reinforced Grout. The strengthening system comprises horizontal strips of ultra‐high strength steel cords, externally bonded to the masonry with hydraulic lime mortar, and connectors to transversal walls, applied within the thickness of the plaster layer. In order to assess the seismic performance of the retrofitted wall, natural accelerograms were applied with increasing intensity up to failure. Test results provide a deep understanding of the effectiveness of mortar‐based composites for improving the out‐of‐plane seismic capacity of masonry walls, in comparison with traditional reinforcements with steel tie‐bars. The structural implications of the proposed solution in terms of dynamic properties and damage development under earthquake loads are also discussed.Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
5.
孙静  谭明  王本华 《内陆地震》2014,28(3):219-226
结合准东石油基地幼儿园的抗震鉴定与加固实例,在对原结构抗震措施鉴定和分析验算的基础上,介绍了房屋结构薄弱部位的加固做法。对类似项目的结构加固有一定的参考价值。  相似文献   
6.
This study describes the seismic performance of an existing five storey reinforced concrete building which represents the typical properties of low-rise non-ductile buildings in Turkey. The effectiveness of shear walls and the steel bracings in retrofitting the building was examined through nonlinear static and dynamic analyses. By using the nonlinear static analysis, retrofitted buildings seismic performances under lateral seismic load were compared with each other. Moreover, the performance points and response levels of the existing and retrofitting cases were determined by way of the capacity-spectrum method described in ATC-40 (1996). For the nonlinear dynamic analysis the records were selected torepresent wide ranges of duration and frequency content. Considering the change in the stiffness and the energy dissipation capacities, the performance of the existing and retrofitted buildings were evaluated in terms of story drifts and damage states. It was found that each earthquake record exhibited its own peculiarities, dictated by frequency content, duration, sequence of peaks and their amplitude. The seismic performance of retrofitted buildings resulted in lower displacements and higher energy dissipation capacity depending mainly on the properties of the ground motions and the retrofitting strategies. Moreover, severe structural damage (irreparable or collapse) was observed for the existing building. However, buildings with retrofit alternatives exhibited lower damage levels changing from no damage to irreparable damage states.  相似文献   
7.
Evaluation of pile foundation response to lateral spreading   总被引:7,自引:0,他引:7  
The effects of liquefaction on deep foundations are very damaging and costly, and they keep recurring in many earthquakes. The first part of the paper reviews the field experience of deep foundations affected by liquefaction during earthquakes in the last few decades, as well as the main lessons learned. The second part of the paper presents results of physical modeling of deep foundations in the presence of liquefaction conducted by the authors and others at the 100g-ton RPI centrifuge. In the last decade centrifuge modeling has been identified as a key tool to identify and quantify mechanisms, calibrate analyses and evaluate retrofitting strategies for pile foundations. Results are presented of centrifuge models of instrumented pile foundations subjected to lateral spreading, including single pile and pile groups, 2- and 3-layer soil profiles, mass and stiffening elements above ground to incorporate the effect of the superstructure, and evaluation of proposed retrofitting strategies. Interpretations of these centrifuge experiments and their relation to field observations and soil properties.  相似文献   
8.
The 2012 Emilia earthquake (in Northern Italy) caused extensive damage to existing prefabricated reinforced concrete structures. These buildings were found being extremely vulnerable because, being designed for vertical loads only, they featured friction‐based connections between structural elements, most commonly between beams and columns. Given the large diffusion of these structures, their seismic retrofit is critical. Various techniques have been proposed in the literature, in most of which friction‐based connections are removed by inserting mechanical connectors that will make beam‐column connections hinged. These approaches lead to a significant increase of the base shear and therefore require strengthening of columns. The paper presents dissipative devices based on carbon‐wrapped steel tubes to be used as an alternative low‐damage solution for the retrofit of beam‐column connections. The first part of the paper presents results of experimental tests on the devices and discusses their dissipative behaviour. The succeeding parts of the paper present numerical analyses on simple structures reinforced with the proposed device. The results of the numerical study show how the introduction of the dissipative devices produces a significant reduction of forces transmitted to the structure, by comparing the seismic response of simple frame structures equipped with dissipative devices with the response of equivalent elastic systems.  相似文献   
9.
Damage or collapse of buildings vulnerable to seismic forces may cause human casualties, and seismic upgrading of such structures is a practical solution to this deficiency. The study presented here proposes a simple approach to prevent structural collapse by separating the superstructure from its foundation to let the superstructure slide during extreme ground shaking. The sliding mechanism contributes to cap the horizontal force exerted on the superstructure. In such approach, the key is to maintain the friction force between the superstructure and the foundation sufficiently low and stable. This research proposes to realize a controlled sliding mechanism, which acts as a structural fuse, by means of carbon powder lubrication at the bases of the structure's columns. The fundamental behaviour of the proposed structural system, named the base shear capping building, is investigated by shaking table tests and numerical simulation. Both experimental and numerical results showed that graphite lubrication is an efficient and robust lubrication material, maintaining the friction coefficient between the steel column bases and mortar foundation at around 0.16. The sliding at the bases significantly reduced the acceleration transmitted to the superstructure, keeping the base shear coefficient not greater than about 0.40. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   
10.
A new methodology for performance‐based optimal seismic retrofitting using a limited number of size groups of viscous dampers is presented. The damping coefficient of each size group of dampers is taken as a continuous variable and is determined by the optimization algorithm. Furthermore, for each potential location, a damper of a single size group is optimally assigned, if any. Hence, the formulation presents a large step forward towards practical optimal design of dampers. The key for achieving an efficient optimization scheme is the incorporation of material interpolation techniques that were successfully applied in other structural optimization problems of discrete nature. This results in a very effective optimization methodology that is expected to be very efficient for large‐scale structures. The proposed approach is demonstrated on several example problems of 3D irregular frame structures. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号