首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   2篇
地球物理   10篇
  2023年   1篇
  2020年   2篇
  2011年   1篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2007年   1篇
  2003年   1篇
  2002年   1篇
排序方式: 共有10条查询结果,搜索用时 355 毫秒
1
1.
The effects of damping in various laminated rubber bearings (LRB) on the seismic response of a ?‐scale isolated test structure are investigated by shaking table tests and seismic response analyses. A series of shaking table tests of the structure were performed for a fixed base design and for a base isolation design. Two different types of LRB were used: natural rubber bearings (NRB) and lead rubber bearings (LLRB). Three different designs for the LLRB were tested; each design had a different diameter of lead plug, and thus, different damping values. Artificial time histories of peak ground acceleration 0.4g were used in both the tests and the analyses. In both shaking table tests and analyses, as expected, the acceleration responses of the seismically isolated test structure were considerably reduced. However, the shear displacement at the isolators was increased. To reduce the shear displacement in the isolators, the diameter of the lead plug in the LLRB had to be enlarged to increase isolator damping by more than 24%. This caused the isolator stiffness to increase, and resulted in amplifying the floor acceleration response spectra of the isolated test structure in the higher frequency ranges with a monotonic reduction of isolator shear displacement. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   
2.
本文研究土与结构相互作用(SSI)对多层及中高层基础隔震建筑地震需求及隔震效率的影响规律,隔震层采用LRB铅芯橡胶与LNR普通橡胶隔震支座组合,就我国现行《建筑抗震设计规范》(GB50011-2010)中软土场地设置隔震层问题做探讨。提出土与基础隔震结构相互作用的简化计算模型,对不同场地及隔震设计目标下的多层及中高层基础隔震结构进行时程分析。研究表明:软土场地基础隔震建筑隔震层的有效隔震效率相对于硬土场地有所下降,必须通过设置具有一定规格的LRB支座来满足隔震目标。本文给出了铅芯橡胶支座极限变形需求随建筑层高及隔震目标变化的规律。  相似文献   
3.
钟先锋  刘文光 《华南地震》2011,31(2):94-102
综合国内外对铅芯橡胶支座力学性能的试验研究成果,考虑各种因素对支座水平方向恢复力模型的影响,提出了主要相关影响凶素的修正系数,依次对支座模型进行解耦分析.分析结果可以用来修止常用的铅芯橡胶支座恢复力模型.  相似文献   
4.
Numerical simulations are performed to assess the effects of near-fault ground motions on base-isolated buildings that consist of either lead-rubber (LRB) or friction-pendulum system (FPS) bearings in addition to supplemented viscous dampers. While LRB and FPS isolation systems have been applied for a number of years, the addition of supplemental damping devices is being currently considered for strong ground motions to reduce the isolator displacements. However, the main problem in this case is that the addition of damping may increase both internal deformation and absolute accelerations of the superstructure and thus may defeat many of the gains for which base isolation is intended. In the present paper, a detailed and systematic investigation on the performance of LRB and FPS isolation systems, provided with supplemental viscous damping under the effect of near-fault ground motions, has been carried out by using commercial finite element software.  相似文献   
5.
In the present study, the seismic behavior of steel–concrete composite structures isolated by base-isolation devices under near-fault earthquake excitations is numerically investigated. The seismic analysis is performed by means of the static non-linear (pushover) analysis procedure conducted on two five-storey three-dimensional (3-D) buildings with steel columns and steel–concrete composite slabs and beams. The present 3-D building examples are assumed to be located at a near-fault area in order to take into account the effect of strong ground motion on the isolation devices. The results of this study allowed the verification of the adequacy of the attachment isolation system as well as the comparison of the behavior of the seismic-protected building with or without bracings to the unprotected buildings with or without bracings, showing the benefits of the application of the isolation devices, the limitations and the characteristics of their performance.  相似文献   
6.
In the paper a simplified nonlinear method has been applied to the analysis of base‐isolated structures. In the first part, a three‐linear idealization of the capacity curve is proposed. The initial stiffness is defined based on the first yielding point in the superstructure, whereas the secondary slope depends on the failure mechanism of the superstructure. A consequence is a much more pronounced secondary slope, which does not correspond to the presumptions used in the originally proposed N2 method. A parametric nonlinear dynamic study of single degree of freedom systems with different hardening slopes and damping has been performed for an ensemble of seven EC8 spectrum‐compatible artificial accelerograms. It was concluded that, in the long‐period range, the equal displacement rule could be assumed also for the proposed systems with non‐zero post‐yield stiffness. In the second part, the proposed idealization was used for the analysis of isolated RC frame buildings that were isolated with different (lead) rubber‐bearing isolation systems. The stiffness of the isolators was selected for three different protection levels and for three different ground motion intensities, which have resulted in elastic as well as moderately and fully damaged superstructure performance levels. Three different lateral load distributions were investigated. It was observed that a triangular distribution, with an additional force at the base, works best in the majority of practical cases. It was concluded that the N2 method can, in general, provide a reasonably accurate prediction of the actual top displacement, as well as of the expected damage to the superstructure. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   
7.
Seismic isolation devices and technology have been developed in the last two decades and the first seismic‐isolated bridge, Bai‐Ho Bridge, in Taiwan was completed in 1999. This bridge was equipped with a seismic monitoring system under the Taiwan Strong Motion Instrumentation Program (TSMIP). On 22 October 1999, a moderate earthquake took place and struck the bridge. The seismic monitoring sensors were normally triggered and produced an intact time history for the health monitoring of the bridge system. The data set provided valuable records about the seismic response of the isolation bridge structure. This paper uses this data to explore the vibration mechanism of Bai‐Ho Bridge. The analysis includes (1) the global dynamic behavior identification and (2) the local component mechanism of the bridge such as the LRB and boundary condition between the deck and the abutments. Both the EMD+HHT method and the non‐linear parametric model were used to identify the model of the bridge structure. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   
8.
针对斜交桥在破坏性地震中发生破坏和损伤的突出问题,采用铅芯橡胶支座(LRB)进行隔震和滞回耗能。基于OpenSees平台建立了不同斜度的传统非隔震和全桥采用LRB隔震的4跨斜交连续梁桥动力分析模型,沿2个水平方向输入远场地震动和具有向前方向性效应、滑冲效应以及无速度脉冲效应的近断层地震动,并进行非线性时程计算,研究桥墩和挡块的损伤状态、主梁旋转度、碰撞力与斜交桥斜度的关系以及LRB对斜交桥抗震性能的影响。结果表明:向前方向性效应和滑冲效应的脉冲型地震动作用下的斜交桥地震反应和损伤明显大于无速度脉冲近断层和远场地震动作用; 采用LRB隔震后,明显降低了固定墩的地震损伤,桥墩位移减震率可达到50%以上; LRB隔震桥主梁与挡块的间隙宜结合桥梁的地震风险和设计位移进行确定。  相似文献   
9.
为研究温度对铅芯橡胶支座(LRB)性能的影响,进行支座拟静力试验。试验表明,在不同温度环境中试件的滞回曲线明显不同,支座的刚度和屈服剪力均随温度的升高而降低;低温时,支座的力学特性变化较大,而当温度大于20℃时,支座的力学特性趋于稳定。以某五层基础隔震建筑为例,编写基础隔震结构非线性时程分析程序NBIS,计算该隔震建筑在考虑温度影响后的地震响应。结果表明,在多遇地震作用下支座恢复力随温度的升高而降低,与罕遇地震下的变化趋势相反;考虑LRB温度影响后,该基础隔震结构的减震系数随环境温度的降低而增大,支座的最大位移随温度升高而增大。  相似文献   
10.
研究了地震地面运动多点激励,即空间变化效应对装有铅芯橡胶支座(Lead Rubber Bearing)的连续梁桥地震反应的影响。首先,利用三角级数法生成了拟合规范反应谱的多点人工地震动时程;然后利用非线性时程分析法数值仿真并比较了某五跨LRB隔震连续梁桥在一致激励、仅考虑地震动行波效应、仅考虑地震动部分相干效应、同时考虑行波和部分相干效应以及同时考虑行波、部分相干和局部场地土效应等七种工况下结构的减震效果。行波效应和部分相干效应对铅芯橡胶支座隔震桥梁影响不大,而局部场地土效应对该类桥梁的地震反应分析影响很大,应该引起重视。  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号