1.
An approximate method for linear analysis of asymmetric‐plan, multistorey buildings is specialized for a single‐storey, base‐isolated structure. To find the mode shapes of the torsionally coupled system, the Rayleigh–Ritz procedure is applied using the torsionally uncoupled modes as Ritz vectors. This approach reduces to analysis of two single‐storey systems, each with vibration properties and eccentricities (labelled ‘effective eccentricities’) similar to corresponding properties of the isolation system or the fixed‐base structure. With certain assumptions, the vibration properties of the coupled system can be expressed explicitly in terms of these single‐storey system properties. Three different methods are developed: the first is a direct application of the Rayleigh–Ritz procedure; the second and third use simplifications for the effective eccentricities, assuming a relatively stiff superstructure. The accuracy of these proposed methods and the rigid structure method in determining responses are assessed for a range of system parameters including eccentricity and structure flexibility. For a subset of systems with equal isolation and structural eccentricities, two of the methods are exact and the third is sufficiently accurate; all three are preferred to the rigid structure method. For systems with zero isolation eccentricity, however, all approximate methods considered are inconsistent and should be applied with caution, only to systems with small structural eccentricities or stiff structures. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   
2.
A procedure for developing equations that estimate the isolator displacement due to strong ground motion is applied to buildings isolated with the friction pendulum system. The resulting design equations, based on rigorous non‐linear analysis, offer an alternative to the iterative equivalent‐linear methods used by current U.S. building codes. The governing equations of the system are reduced to a form such that the median normalized displacement of the system due to an ensemble of ground motions is found to depend on only the isolation period—a function of the curvature of the isolator—and the friction force at incipient slip normalized by peak ground velocity. The normalization is effective in minimizing the dispersion of the normalized displacement for an ensemble of ground motions, implying that the median normalized displacement is a reliable estimate of response. The design equations reflect the significant (20 to 38%) increase in displacement when the excitation includes two lateral components of ground motion instead of just one component. Equivalent‐linear methods are shown to underestimate by up to 30% the exact median displacement determined by non‐linear response history analysis for one component of ground motion, and building codes include at most a 4.4% increase for a second component. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   
3.
岩体中泥化夹层的流变试验及其长期强度的确定   总被引:3,自引:2,他引:1  
文中首先介绍两种室内试验设备--单剪流变仪和剪应力松弛仪(松弛流变仪)及其试验方法,然后根根岩体中泥化夹层的试验成果,证实陈宗基教授提出的最高屈服值f3--强度的临界值即长期强度值,工程设计要重视它。  相似文献   
4.
A full‐scale 5‐story steel moment frame building was subjected to a series of earthquake excitations using the E‐Defense shake table in August, 2011. For one of the test configurations, the building was seismically isolated by a hybrid system of lead‐rubber bearings and low friction roller bearings known as cross‐linear bearings, and was designed for a very rare 100 000‐year return period earthquake at a Central and Eastern US soil site. The building was subject to 15 trials including sinusoidal input, recorded motions and simulated earthquakes, 2D and 3D input, and a range of intensities including some beyond the design basis level. The experimental program was one of the first system‐level full‐scale validations of seismic isolation and the first known full‐scale experiment of a hybrid isolation system incorporating lead‐rubber and low friction bearings. Stable response of the hybrid isolation system was demonstrated at displacement demands up to 550 mm and shear strain in excess of 200%. Torsional amplifications were within the new factor stipulated by the code provisions. Axial force was observed to transfer from the lead‐rubber bearings to the cross‐linear bearings at large displacements, and the force transfer at large displacements exceeded that predicted by basic calculations. The force transfer occurred primarily because of the flexural rigidity of the base diaphragm and the larger vertical stiffness of the cross‐linear bearings relative to the lead‐rubber bearings.  相似文献   
5.
The accuracy of a series spring model to predict the peak displacement and displacement history of Triple Pendulum? (TP) bearings in a strongly shaken, full‐scale building is evaluated in this paper. The series spring model was implemented as a self‐contained three‐dimensional TP bearing element in OpenSees and is now available for general use. The TP bearing element contains the option for constant friction or a generalized friction model that accounts for the effect of instantaneous velocity and compression load on the friction coefficient. Comparison between numerical simulation and experimental data of a five‐story steel moment frame building shows that the peak displacement of isolation system can generally be predicted with confidence using a constant friction coefficient model. The friction coefficient model accounting for the effect of axial load and velocity leads to minor improvement over the constant friction coefficient models in some cases. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   
6.
A procedure based on rigorous non‐linear analysis is presented that estimates the peak deformation among all isolators in an asymmetric building due to strong ground motion. The governing equations are reduced to a form such that the median normalized deformation due to an ensemble of ground motions with given corner period Td depends primarily on four global parameters of the isolation system: the isolation period Tb, the normalized strength η, the torsional‐to‐lateral frequency ratio Ωθ, and the normalized stiffness eccentricity eb/r. The median ratio of the deformations of the asymmetric and corresponding symmetric systems is shown to depend only weakly on Tb, η, and Ωθ, but increases with eb/r. The equation developed to estimate the largest ratio among all isolators depends only on the stiffness eccentricity and the distance from the center of mass to the outlying isolator. This equation, multiplied by an earlier equation for the deformation of the corresponding symmetric system, provides a design equation to estimate the deformations of asymmetric systems. This design equation conservatively estimates the peak deformation among all isolators, but is generally within 10% of the ‘exact’ value. Relative to the non‐linear procedure presented, the peak isolator deformation is shown to be significantly underestimated by the U.S. building code procedures. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   
7.
In this study, the multi‐intensity seismic response of code‐designed conventional and base‐isolated steel frame buildings is evaluated using nonlinear response history analysis. The results of hazard and structural response analysis for three‐story braced‐frame buildings are presented in this paper. Three‐dimensional models for both buildings are created and seismic response is assessed for three scenario earthquakes. The response history analysis results indicate that the design objectives are met and the performance of the isolated building is superior to the conventional building in the design event. For the Maximum Considered Earthquake, isolation leads to reductions in story drifts and floor accelerations relative to the conventional building. However, the extremely high displacement demands of the isolation system could not be accommodated under normal circumstances, and creative approaches should be developed to control displacements in the MCE. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   
8.
Studies have shown the effectiveness of providing supplemental energy dissipation in base‐isolated structures to reduce displacements at the isolation level. A previous analytical study demonstrated the benefits of providing this energy dissipation at a specified gap larger than the design displacement. The gap before engagement allows the base isolation system to meet performance criteria in varying levels of ground excitation. Use of this ‘gap damper’ device eliminates undesirable effects often exhibited with large amounts of supplemental damping at lower intensity motions. Using results from an analytical study, the primary purpose of this research was to develop devices for practical implementation. Development of the devices demanded simplicity, feasibility, economy, and reliability to be an effective option in building design and construction. Multiple designs were proposed, and a final design was chosen based on selection criteria and finite element analyses. The device was designed and tested in Auburn University's Structural Research Lab. Experimental results were compared with theoretical models to verify behavior and make necessary adjustments for a shake table experiment. The design parameters were selected to accommodate re‐use of the device for the shake table test. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
9.
First in this paper, two types of apparatus in laboratories, the simple shear plastometer and the relaxation plastometer, and the methods of simple shear testing and relaxation testing are introduced. Then according to the test results of thin interbedded clayey seams in rock, the upper yield value f3-ritical stress suggested by Dr. Tan Tjongkie is the limit long-term stress to rocks or soils. For engineering purposes it is important to know their long-term creep strength.\  相似文献   
10.
黎克日 《岩土力学》1984,5(2):67-73
本仪器采用 FBM-3D-009型步进电机作动力源实现自控,电机转速分两段连续可调,第一段为1转/分~90转/分;第二段为110转/分~360转/分。剪位移的大小通过调节两个光敏二极管的距离来控制,精度达±0.01毫米。1~9999次的剪切次数可以预置,并可通过电子数码管不断地显示实际剪切次数。当剪切次数达到预置剪切次数时,自动停机,终止试验。另外,可通过手动开关,作人工控制。剪位移、剪应力可通过相应的传感器作自动记录。本仪器可做直剪快剪、松弛流变、疲劳剪切、单脉冲冲击等试验。  相似文献   