排序方式: 共有35条查询结果,搜索用时 15 毫秒
1.
2.
3.
S. Bilir T. Güver I. Khamitov T. Ak S. Ak K. B. Coşkunoğlu E. Paunzen E. Yaz 《Astrophysics and Space Science》2010,326(1):139-150
We present CCD BV and JHK
s
2MASS photometric data for the open cluster NGC 1513. We observed 609 stars in the direction of the cluster up to a limiting
magnitude of V∼19 mag. The star-count method showed that the centre of the cluster lies at α
2000=04
h
09
m
36
s
, δ
2000=49°28′43″ and its angular size is r=10 arcmin. The optical and near-infrared two-colour diagrams revealed the colour excesses in the direction of the cluster
as E(B−V)=0.68±0.06, E(J−H)=0.21±0.02 and E(J−K
s
)=0.33±0.04 mag. These results are consistent with normal interstellar extinction values. Optical and near-infrared Zero Age
Main-Sequences (ZAMS) provided an average distance modulus of (m−M)0=10.80±0.13 mag, which can be translated into a distance of 1440±80 pc. Finally, using Padova isochrones we determined the
metallicity and age of the cluster as Z=0.015±0.004 ([M/H]=−0.10±0.10 dex) and log (t/yr)=8.40±0.04, respectively. 相似文献
4.
5.
6.
7.
8.
9.
Duygu Ozdes Celal Duran Hacer Bayrak Volkan Numan Bulut Mehmet Tufekcı 《洁净——土壤、空气、水》2012,40(2):211-217
A new separation and preconcentration technique based on coprecipitation of Cu(II) and Ni(II) ions by the aid of Mo(VI)/di‐tert‐butyl{methylenebis[5‐(chlorobenzyl)‐4H‐1,2,4‐triazol‐3,4‐diyl]}biscarbamate (BUMECTAC) precipitate has been established. The Mo(VI)/BUMECTAC precipitate was dissolved by concentrated HNO3 and the solution was completed to 5.0 mL with distilled/deionized water. The levels of the analyte ions were determined by flame atomic absorption spectrometer. The effects of experimental conditions like HNO3 concentration, amount of BUMECTAC and Mo(VI), sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of analyte ions. The preconcentration factors were found to be 40 for Cu(II) and 100 for Ni(II) ions. The detection limits for Cu(II) and Ni(II) ions based on 3σ (N:10) were 0.43 and 0.70 µg L?1, respectively. The relative standard deviations were found to be lower than 4.0% for both analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of two certified reference materials (Environment Canada TM‐25.3 and CRM‐SA‐C Sandy Soil C). The procedure was successfully applied to sea water and stream water as liquid samples and baby food as solid sample in order to determine the levels of Cu(II) and Ni(II) ions. 相似文献
10.