首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   0篇
地球物理   8篇
地质学   3篇
海洋学   7篇
天文学   1篇
自然地理   1篇
  2013年   1篇
  2012年   2篇
  2010年   2篇
  2008年   1篇
  2007年   2篇
  2006年   3篇
  2005年   2篇
  2003年   1篇
  2001年   1篇
  1997年   2篇
  1988年   1篇
  1985年   1篇
  1984年   1篇
排序方式: 共有20条查询结果,搜索用时 109 毫秒
1.
Heat flow estimated from the gas hydrate layers on the landward slope of the Nankai Trough reveals that heat flow increases downslope toward the trench floor. This data plus six new heat flow values obtained by a conventional probe and two values available from DSDP drill holes give a fairly detailed heat flow distribution in the Nankai Trough area, when combined with the already existing data set. There appears to be a zonal pattern parallel to the trough axis, with a high heat flow zone on the floor of the trough that is quite anomalous for a subduction zone. It might be explained as a result of subduction of the hot portion of the Philippine Sea plate, i.e. the Shikoku Basin, and/or of more local effects such as heating due to intrusion of hot water from subducted sediments to shallow depth beneath the trough floor. Surface heat flow patterns landward of the trough were calculated for a simple thermal model of subduction. Perfect reproduction of the observed zonal pattern is difficult to achieve by the simple model, suggesting the necessity for further heat flow and other observations.  相似文献   
2.
Thirty-three new measurements on the seaward slope and outer rise of the Japan Trench along a parallel of 38°45′N revealed the existence of high heat flow anomalies on the subducting Pacific plate, where the seafloor age is about 135 m.y.. The most prominent anomaly with the highest value of 114 mW/m2 is associated with a small mound on the outer rise, which was reported to be a kind of mud volcano. On the seaward slope of the trench, heat flow is variable: high (70–90 mW/m2) at some locations and normal for the seafloor age (about 50 mW/m2) at others. The spatial variation of heat flow may be related to development of normal faults and horst/graben structures due to bending of the Pacific plate before subduction, with fluid flow along the fault zones enhancing the vertical heat transfer. Possible heat sources of the high heat flow anomalies are intra-plate volcanism in the last several million years like that discovered recently on the Pacific plate east of the Japan Trench.  相似文献   
3.
In a coral reef environment, a slight increase in dissolved inorganic nitrogen (DIN;> or =1.0 micro M) can alter the ecosystem via macroalgal blooms. We collected seagrass leaves from the tropical and subtropical Pacific Ocean in five countries and examined the interactions between nutrient concentrations (C, N, P), molar ratios of nutrients, and delta15N to find a possible indicator of the DIN conditions. Within most sites, the concentrations of nutrients and their molar ratios showed large variations owing to species-specific values. On the other hand, almost identical delta15N values were found in seagrass leaves of several species at each site. The correlations between delta15N and nutrient concentrations and between delta15N and molar ratios of nutrients suggested that nutrient availability did not affect the delta15N value of seagrass leaves by altering the physiological condition of the plants. Increases in delta15N of seagrass leaves mostly matched increases in DIN concentrations in the bottom water. We suggest that delta15N in seagrass leaves can be a good tool to monitor time-integrated decrease/increase of DIN concentrations at a site, both in the water column and the interstitial water.  相似文献   
4.
To reconstruct the recent climate history in Kamchatka, a series of repeated precise temperature logs were performed in a number of boreholes located in a broad east-west strip (between 52 and 54°N) in the central part of Kamchatka west of Petropavlovsk-Kamchatski. Within three years more than 30 temperature logs were performed in 10 holes (one up to six logs per hole) to the depth of up to 400 metres. Measured temperature gradients varied in a broad interval 0 to 60 mK/m and in some holes a sizeable variation in the subsurface temperatures due to advective heat transport by underground water was observed. Measured data were compared with older temperature profiles obtained in the early eighties by Sugrobov and Yanovsky (1993). Even when older data are of poorer precision (accuracy of about 0.1 K), they presented valuable information of the subsurface temperature conditions existing 20–25 years ago. Borehole observations and the inverted ground surface temperature histories (GSTHs) used for the paleoclimate reconstruction were complemented with a detailed survey of meteorological data. Namely, the long-term surface air temperature (SAT) and precipitation records from Petropavlovsk station (in operation since 1890) were used together with similar data from a number of local subsidiary meteo-stations operating in Central Kamchatka since 1950. Regardless of extreme complexity of the local meteorological/climate conditions, diversity of borehole sites and calibration of measuring devices used during the whole campaign, the results of the climate reconstruction supported a general warming of about 1 K characteristic for the 20th century, which followed an inexpressive cooler period typical for the most of the 19th century. In the last three to four decades the warming rate has been locally increasing up to 0.02 K/year. It was also shown that the snow cover played a dominant role in the penetration of the climate “signal” to depth and could considerably smooth down the subsurface response to the changes occurred on the surface.  相似文献   
5.
The reef islands formed on coral atolls are generally small, low, and flat, with elevations of only a few meters. These islands are thus highly vulnerable to elevated sea levels caused by extreme events and global warming. Such vulnerability was recently evidenced at Fongafale Islet, the capital of Tuvalu, when it flooded during accelerated spring high tides possibly related to sea level rise caused by global warming. Many factors, not only environmental but also economic and social, determine the vulnerability of an island to sea level rise. In this study, we used data spanning 108 yrs to reconstruct changes in topography, land use/cover, population, and the distribution of buildings at Fongafale Islet. The results indicate that the vulnerability of Fongafale Islet relates to its original landform characteristics: the central part of the island was formerly dominated by swampland that flooded at high tides. Fongafale Islet experienced greater population in-migration and centralization beginning in the 1970s following the independence of Tuvalu and Kiribati. Migrants were also responding to declines in overseas mining operations and limited options for paid employment. As the population increased, construction took place in vulnerable swampland areas. Our results clearly demonstrate that examinations of global environmental issues should focus on characteristics specific to the region of interest. These characteristics should be specified using historical reconstruction to understand and address the vulnerability of an area to global environmental changes.  相似文献   
6.
Urbanization has become one of the domain processes for city development in Indonesia. The results of the extremely high densities of fast growing population have led to negative subsurface environmental impact. Jakarta, as one of the rapidly developed and urbanized cities in Southeast Asia, has become one of the interesting urbanization city to analyze its effects. In Jakarta, the use of groundwater has greatly accelerated conforming to the rise in its population and the development of the industrial sector, which consume a relatively large amount of water. The increase of groundwater exploitation in Jakarta city has already caused a negative impact on these resources. Therefore, an assessment of groundwater trends in the urban area, including their hazard and risk management, is a necessary action. This paper describes the assessment of urban groundwater loading caused by human concentration in Jakarta city. Subsurface heat contamination under the condition of surface warming shows significant effects of urban groundwater loading during the past century in Jakarta city.  相似文献   
7.
A Geographic Information System (GIS)-aided flow-tracking technique was adopted to investigate nutrient exchange rates between specific benthic communities and overlying seawater in a fringing reef of Ishigaki Island, subtropical Northwestern Pacific. Net exchange rates of NO3 , NO2 , NH4 +, PO4 3−, Total-N and Total-P were estimated from concentration changes along the drogue trajectories, each of which was tracked by the Global Positioning System and plotted on a benthic map to determine the types of benthic habitat over which the drogue had passed. The observed nutrient exchange rates were compared between 5 typical benthic zones (branched-coral (B) and Heliopora communities (H), seaweed-reefrock zone (W), bare sand area (S), and seagrass meadow (G)). The dependence of nutrient exchange rates on nutrient concentrations, physical conditions and benthic characteristics was analyzed by multiple regression analysis with the aid of GIS. The spatial correlation between nutrient exchange rates and benthic characteristics was confirmed, especially for NO3 and PO4 3−, which were usually absorbed in hydrographically upstream zones B and W and regenerated in downstream zones H and G. NO3 uptake in zones B and W was concentration-dependent, and the uptake rate coefficient was estimated to be 0.58 and 0.67 m h−1, respectively. Both nutrient uptake in zone W and regeneration in zone H were enhanced in summer. The net regeneration ratio of NO3 /PO4 3− in zone H in summer ranged 5.2 to 34 (mean, 17.4), which was somewhat higher than previously measured NO3 /PO4 3− for sediment pore waters around this zone (1.1–8.5). Nutrient exchanges in zone S were relatively small, indicating semi-closed nutrient cycling at the sediment-water interface of this zone. NH4 + efflux from sediments was suggested in zone G. The data suggest that the spatial pattern of nutrient dynamics over the reef flat community was constrained by zonation of benthic biota, and that abiotic factors such as nutrient concentrations and flow rates, influenced nutrient exchange rates only in absorption-dominated communities such as zones B and W.  相似文献   
8.
In order to infer past climatic change in central Japan, we measured temperatures in a borehole at the Karasuma site, on the southeastern coast of Lake Biwa, and reconstructed sediment surface temperature history during the last 3000 years. The reconstructed temperature history shows apparent Medieval Warm Period, Little Ice Age, and contemporary temperature warming. However, the large amplitude of the temperature changes up to 4-5 K cannot be explained by past climatic change only, suggesting that there was some other cause of the larger amplitude temperature changes. The onsets of temperature decrease in the late 12th century a.d. and temperature increase in the mid 17th century a.d. appear to coincide with occurrences of two destructive earthquakes (1185 and 1662 a.d.) that caused water level changes of Lake Biwa. It suggests that the reconstructed sediment surface temperature history reflects the environmental change due to tectonically induced water level changes of the lake. If the annual mean of the ground surface temperature was higher than that of the bottom water temperature in a shallow part of the lake, which is consistent with the present-day data, the large amplitude of the sediment surface temperature change may be attributed to a combined effect of past climatic and environmental changes. Thus, we suggest that the borehole temperature at the Karasuma site preserves information not only on past climate changes but also on environmental changes due to tectonically induced water level changes.  相似文献   
9.
Long-term temperature monitoring was carried out in a borehole drilled for investigation of the Nojima fault, an active fault in SW Japan, using the distributed optical fiber temperature sensing (DTS) technique. Temperatures in the borehole had been measured every 1 m along an optical fiber cable with a resolution of about 0.1 K over a period of 6 years. Water injection experiments were conducted in this borehole in 1997, 2000 and 2003. Monitoring of the temperature profile was started after the first injection experiment, and the temperature profile remained very stable until the start of the second injection experiment. During the second and third experiments, the temperatures in the borehole dropped due to cooling by the injected water but no appreciable temperature change was observed below about 580 m. It clearly shows that the water leaked out of the hole around this point and the leaking depth is estimated to be about 540 m based on the shape of the temperature profile. After the injection was stopped, the recovery of the temperature to the undisturbed profile was exceptionally slow around the leaking point, resulting in a local temperature anomaly, probably because the water leaking out of the hole had cooled the surrounding formations extensively. A very similar temperature anomaly was observed at the beginning of temperature monitoring, which suggests that water leaked out at the same depth in the first injection experiment as well. Between the second and third injection experiments, the top of the borehole was kept open to allow groundwater discharge for about 1 month in 2000 and 2003. In both periods, groundwater flowed out continuously and the shapes of the observed temperature profiles indicate that the groundwater entered in the hole at the same depth as the leaking point during the injection experiments. The temperature records also show that the rate of discharge had been nearly constant through the two test periods. The water discharge appears to have been little affected by the water injection. These results demonstrate that the optical fiber temperature monitoring system is a very effective tool for hydrological experiments.  相似文献   
10.
The seismogenic zone of subduction thrust faults   总被引:13,自引:0,他引:13  
Abstract Subduction thrust faults generate earthquakes over a limited depth range. They are aseismic in their seaward updip portions and landward downdip of a critical point. The seaward shallow aseismic zone, commonly beneath accreted sediments, may be a consequence of unconsolidated sediments, especially stable-sliding smectite clays. Such clays are dehydrated and the fault may become seismogenic where the temperature reaches 100--150°C, that is, at a 5--15 km depth. Two factors may determine the downdip seismogenic limit. For subduction of young hot oceanic lithosphere beneath large accretionary sedimentary prisms and beneath continental crust, the transition to aseismic stable sliding is temperature controlled. The maximum temperature for seismic behavior in crustal rocks is ~ 350°C, regardless of the presence of water. In addition, great earthquake ruptures initiated at less than this temperature may propagate with decreasing slip to where the temperature is ~ 450°C. For subduction beneath thin island arc crust and beneath continental crust in some areas, the forearc mantle is reached by the thrust shallower than the 350°C temperature. The forearc upper mantle probably is aseismic because of stable-sliding serpentinite hydrated by water from the underthrusting oceanic crust and sediments. For many subduction zones the downdip seismogenic width defined by these limits is much less than previously assumed. Within the narrowly defined seismic zone, most of the convergence may occur in earthquakes. Numerical thermal models have been employed to estimate temperatures on the subduction thrust planes of four continental subduction zones. For Cascadia and Southwest Japan where very young and hot plates are subducting, the downdip seismogenic limit on the subduction thrust is thermally controlled and is shallow. For Alaska and most of Chile, the forearc mantle is reached before the critical temperature, and mantle serpentinite provides the limit. In all four regions, the seismogenic zones so defined agree with estimates of the extent of great earthquake rupture, and with the downdip extent of the interseismic locked zone.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号