首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   23篇
  免费   0篇
大气科学   1篇
地球物理   3篇
地质学   18篇
自然地理   1篇
  2013年   1篇
  2010年   1篇
  2008年   6篇
  2007年   1篇
  2006年   1篇
  2005年   2篇
  2004年   3篇
  2003年   3篇
  2002年   3篇
  2000年   2篇
排序方式: 共有23条查询结果,搜索用时 15 毫秒
1.
Information on the distribution of subsurface temperature and hydraulic heads at 24 observation wells in and around the Tokyo Lowland, the eastern part of the Tokyo Metropolitan area, were examined to make clear the relationship between groundwater and the subsurface thermal environment in the urban area. Minimums in temperature–depth logs due to subsurface temperature increasing at shallow parts were recognized in 21 wells. This fact shows subsurface temperature is affected by ground surface warming in almost all of this area. Deeper than minimums, where the effects of surface warming became relatively small, regional variation is observed as follows: high temperatures are shown in the central part to the southern part, and low temperatures shown in the inland to eastern part. The high temperature area corresponds to an area where the lower boundary of groundwater flow is relatively shallow. This area corresponds also to an area with severe land subsidence resulting from excessive groundwater pumping. It is considered that this high temperature area is formed by the effects of upward groundwater flow affected by hydrogeological conditions and pumping. On the other hand, a comparison between past data (1956–1967) and present data (2001–2003) revealed widespread decreasing temperature in the inland area. This is explained by downward groundwater flow based on an analysis of temperature–depth logs. This fact suggests that subsurface temperature is not only increasing from the effects of surface warming but also decreasing from the effects of groundwater environment change due to pumping.  相似文献   
2.
Urbanization has become one of the domain processes for city development in Indonesia. The results of the extremely high densities of fast growing population have led to negative subsurface environmental impact. Jakarta, as one of the rapidly developed and urbanized cities in Southeast Asia, has become one of the interesting urbanization city to analyze its effects. In Jakarta, the use of groundwater has greatly accelerated conforming to the rise in its population and the development of the industrial sector, which consume a relatively large amount of water. The increase of groundwater exploitation in Jakarta city has already caused a negative impact on these resources. Therefore, an assessment of groundwater trends in the urban area, including their hazard and risk management, is a necessary action. This paper describes the assessment of urban groundwater loading caused by human concentration in Jakarta city. Subsurface heat contamination under the condition of surface warming shows significant effects of urban groundwater loading during the past century in Jakarta city.  相似文献   
3.
Proper management of groundwater resources requires knowledge of the processes of recharge and discharge associated with a groundwater basin. Such processes have been identified in the Jakarta groundwater basin, Indonesia using a theory that describes the simultaneous transfer of heat and fluid in a porous medium. Temperature-depth profiles in monitoring wells are used to determine the geothermal gradient. To examine the rules of groundwater flow in the distortion of the isotherms in this area, several methods are compared. Subsurface temperature distribution is strongly affected by heat advection due to groundwater flow. Under natural flow conditions, the recharge area is assumed to occur in the hills and uplands, which are located on the periphery of the Jakarta basin, and the discharge area is located in the central and northern part of the Jakarta groundwater basin. A transition area, which could act as local recharge and discharge areas, occupies the middle of the lowland. Subsurface temperatures show good correlation with the groundwater flow conditions, and the data yield important information on the location of recharge and discharge areas.  相似文献   
4.
Combined X-ray powder diffraction, Mössbauer, and XANES spectroscopy in situ experiments revealed the transformation of cubic (Mg0.8Fe0.2)O ferropericlase to a rhombohedrally distorted phase at 35(1) GPa and room temperature. The Mössbauer spectroscopy results show that the rhombohedral distortion does not involve magnetic ordering. Combined with data from the literature, our results imply that the cubic to rhombodedral transition occurs in (Mg,Fe)O under conditions of non-hydrostatic stress over a wide range of composition (0.2≤x Fe≤1).  相似文献   
5.
Located at southern coast of China, the Pearl River Delta (PRD) is facing serious water problems in both quantity and quality after its rapid urbanization in the last decade. Most remarkably, the local groundwater, that was used to be the source of drinking water before the urbanization was polluted due to poor management of the septic tanks. In order to study the effects of suburban development on local groundwater flow and water quality in the PRD region, Fengcun of Guangzhou has been chosen as the study area. In Fengcun, drinking water was groundwater before the 1990s, but now piped reservoir water is used by each family because the groundwater has been polluted. This study clarifies the source and process of the groundwater pollution from septic tanks using isotopic and geochemical characteristics, especially nitrate (NO3?) concentrations. Water samples were collected from the wells and ponds in Fengcun in March and July 2005 and in July 2006. Based on the pe–pH diagram, NO3? and ammonium of groundwater are from the effect of human activities, rather than from nitrification and ammonification of N2. NO3? pollution of groundwater is from point sources, and NO3? concentrations decrease from northeast to southwest. Groundwater is polluted rapidly by the leakage of septic tanks. NO3? concentrations of pollution sources were lower than 20 mg l?1 in March 2005, but had increased to about 120 mg l?1 in July 2006. This implies that groundwater protection should be strengthened in rural areas of the PRD. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   
6.
A survey of the quality of groundwater across a broad area of the North China Plain, undertaken in 1998 to 2000, indicates that nitrate pollution is a serious problem affecting the drinking water for a vast population. The use of nitrogen (N)-fertilizer in agriculture has greatly increased over the past 20 years to meet the food needs of the rapidly expanding population. During the study, 295 water samples were collected from wells and springs to determine the water chemistry and the extent of nitrate pollution. High concentrations of nitrate, especially in a recharge area along the western side, but also in the vicinity of Beijing and locally in other parts of the plain, pose a serious problem for the drinking water supply. In places, the nitrate concentration exceeds the maximum for safe drinking water of 45 mg/L. The intense use of N-fertilizer and the widespread use of untreated groundwater for crop irrigation contribute greatly to the problem, but no doubt the disposal of industrial and municipal waste into streams and infiltrating the aquifer also contribute to the problem; however, the lack of data prevents evaluation of those sources. In the recharge area, nitrate is found at depths of as much as 50 m. Near Beijing, relatively high concentrations of nitrate occur at depths of as much as 80 m. In the discharge area, in the vicinity of the Yellow River, high concentrations of nitrate occur at depths of <8 m.

Electronic Supplementary Material Supplementary Material is available in the online version of this article at
Resumen Contaminacíon de nitratos a causa de prácticas agrícolas en diferentes zonas hidrogeológicas del sistema de flujo regional de aguas subterráneas en la planice del norte de China. Un estudio de la calidad del agua subterránea en una zona amplia de la planice del norte de China se llevó a cabo entre 1998 y el año 2000. Este estudio indica que la contaminación de nitratos es un problema grave que afecta el agua potable de una vasta población. El uso de fertilizantes a base de nitratos en la agricultura ha aumentado considerablemente durante los últimos 20 años para satisfacer las necesidades alimentices de la creciente población. Durante el estudio, se tomaron 295 muestras de pozos de agua y manantiales para determinar la química de las aguas y el grado de contaminación por nitratos. Altas concentraciones de nitratos, especialmente en una zona de recarga a lo largo del lado oeste, asì como en la cercanía a Pekín y en zonas locales en otras partes de la planicie, presentan un problema serio al sumunistro de agua potable. En ciertos lugares, la concentracióon de nitratos excede el nivel máximo de seguridad para el agua potable 45 mg NO3/L. El intenso uso de fertilizantes de nitratos y el abundante uso de agua subterránea sin tratamiento para la irrigación de cultivos contribuyen sustancialmente al problema. Sin embargo, sin lugar a dudas, la descarga de deshechos industriales y municipales en arroyos y en el acuífero también contribuyen al problema. La falta de datos impide la evalución de dichas fuentes. En la zona de recarga se encuentran nitratos hasta los 50 m de profundidad. Cerca a Pekín, concentraciones relativamente altas de nitrato ocurren hasta los 80 m de profunidad. En las zonas de descarga afectadas por el Río Amarillo las concentraciones altas de nitrato se encuentran solamente a menos de 8m de profundidad.

Resumé Une campagne dévaluation de la qualité de leau souterraine entreprise entre 1998 et 2000 à travers une vaste étendue de la plaine du nord en Chine indique que la pollution par les nitrates est un problème sérieux qui affecte la qualité de leau souterraine pour une abondante population. Lutilisation de fertilisants azotés pour lagriculture a augmenté considérablement durant les 20 dernières années afin de rencontrer les besoins alimentaires dune population à forte croissance. Lors de cette étude, 295 échantillons deau ont été prélevés dans des puits et sources naturelles afin de déterminer la composition chimique de leau souterraine ainsi que létendue de la pollution par les nitrates. Des concentrations élevées de nitrates, en particulier dans une zone de recharge le long de la limite ouest de la plaine, mais aussi dans la région de Beijing et sporadiquement dans la plaine, posent de sérieux problèmes à la consommation de leau souterraine. A certains endroits, la concentration en nitrates excède la valeur maximale acceptée pour la consommation qui est de 45 mg NO3/L. Lutilisation intensive de fertilisants azotés ainsi que lutilisation répandue deau souterraine non traitée pour lirrigation contribuent pour beaucoup au problème, mais il ne fait pas de doute que le rejet des déchets municipaux et industriels dans les rivières et aquifères y est aussi pour quelque chose. Par contre, le manque de donnés ne permet pas dévaluer la contribution de chacune de ces sources. Dans la zone de recharge, les nitrates se retrouvent à des profondeurs allant jusquà 50 m. Près de Beijing, des concentrations relativement élevées de nitrate ont été mesurées à des profondeurs allant jusquà 80 m. Enfin, dans la zone démergence affectée par la rivière Jaune, les fortes concentrations se retrouvent à une profondeur maximale de 8 m.
  相似文献   
7.
The purpose of this study was to trace the groundwater flow system in the Nagaoka area using subsurface temperature distribution, stable isotopes and water quality. Temperature-depth profiles were measured four times in observation wells during the period 2000–2002. Water was sampled from both observation and pumping wells during the same period. A combination of tracers was used to conceptualize the groundwater flow system. The flow system appears to be divided into shallow, intermediate and deep systems. It is clear that land use, pumping and the infiltration rate are affecting the shallow flow system.An erratum to this article can be found at  相似文献   
8.
9.
A Nappe system south to southwest of the São Francisco Craton represents the southern extension of the Brasília belt and describes an inverted metamorphic pile of greenschist facies toward amphibolite facies. The Aiuruoca-Andrelândia nappe is one of the nappes of this system. The hind portion of the Aiuruoca-Andrelândia nappe, south of Caxambu and Aiuruoca (MG), consists of a structural-metamorphic domain transported toward the E-NE. There is a metamorphic transition, from the kyanite zone to kyanite and sillimanite coexistence, until the sillimanite zone. Metapelitic rocks preserve high-pressure parageneses (Rt–Ky–Grt–Ms–Bt–Pl–Qtz) and contain retrograde eclogitic rocks. Sil–Pl–Qtz coronitic intergrowths around garnets are common decompressive textures. Kyanite schists register the Pmax of 11 kbar at 660 °C and define a decompressive path until 6–7.5 kbar at 650 °C. These PT conditions represent the equilibrium in S2 schistosity (amphibolite facies) and the beginning of the cooling path in the Ky–Sil transition. The decompressive path suggests an extrusional process, immediately after burying at about 60 km. Exhumation controlled by convergent events, related to the São Francisco Plate subduction and tectonic erosion, took these units, isothermally, to higher levels (20–33 km). Later, the metamorphic path shifted toward near-isobaric cooling.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号