排序方式: 共有9条查询结果,搜索用时 546 毫秒
1
1.
2.
热岩石圈厚度是研究盆地的构造演化和板块动力学的重要参数,本文通过实测数据构建地壳分层模型,根据热传导的基本原理,计算了冀中坳陷中部的Moho面温度以及热岩石圈厚度,并探讨其地热学意义。结果表明:冀中坳陷中部的Moho面温度分布在500~600℃,西南侧整体温度较东北部高,热岩石圈厚度介于102~122km,其平面展布特征与华北克拉通热岩石圈厚度西厚东薄的特征相吻合,为华北克拉通受太平洋板块西向俯冲导致东部遭受破坏提供了依据,并且较薄的岩石圈使热流更易传导到地壳浅部,成为了该地区热异常的成因背景。 相似文献
3.
Water losses risk assessment: an example from Carpathian karst 总被引:1,自引:1,他引:0
The multipurpose dam and reservoir “Bogovina” in the Crni Timok valley is one of several projects that have been initiated
to improve water availability in Serbia. The site and height of the dam were initially proposed without consideration of risk
factors such as water leakage or stability of the banks. Later, complex hydrogeological and speleological surveys and tests
identified the potential of significant water losses from the reservoir area connected mainly to the karstic aquifer, and
the nearby Bogovina cave system. The analyses show that once the reservoir is filled up, groundwater flow currently oriented
towards the future reservoir would saturate the upper part of the karstified rocks, reactivate currently unsaturated pathways
and form a reverse discharge outside of the reservoir area. In response to these findings, the dam design and technical details
have been adapted accordingly: the dam height has been reduced by 9 m, and it is proposed that grouting and consolidation
work be conducted both at the foundation of the dam and extensively on the embankments. It was concluded that although the
proposed remedial measures cannot guarantee reservoir tightness, they can reduce the risk of large-scale leaking. 相似文献
4.
We propose a methodology for estimating the residence time of groundwater based on bomb-produced (36)Cl. Water samples were collected from 28 springs and 2 flowing wells located around Mt. Fuji, Central Japan. (36)Cl/Cl ratios in the water samples, determined by accelerator mass spectrometry (AMS), were between 43 × 10(-15) and 412 × 10(-15). A reference time series of the above-background (i.e., bomb-derived) (36)Cl concentration was constructed by linearly scaling the background-corrected Dye-3 data according to the estimated total bomb-produced (36)Cl fallout in the Mt. Fuji area. Assuming piston flow transport, estimates of residence time were obtained by comparing the measured bomb-derived (36)Cl concentrations in spring water with the reference curve. The distribution of (36)Cl-based residence times is basically consistent with that of tritium-based estimates calculated from data presented in previous studies, although the estimated residence times differ between the two tracers. This discrepancy may reflect chlorine recycling via vegetation or the relatively small change in fallout rate, approximately since 1975, which would give rise to large uncertainties in (36)Cl-based estimates of recharge for the period, approximately since 1975. Given the estimated ages for groundwater from flowing wells, dating based on a (36)Cl bomb pulse may be more reliable and sensitive for groundwater recharged before 1975, back as far as the mid-1950s. 相似文献
5.
Tetsuya Tokiwa Kimikazu Tsusaka Makoto Matsubara Taiki Ishikawa Daisuke Ogawa 《地学前缘(英文版)》2013,4(1):105-111
This paper focuses on the formation mechanism of fractures induced by excavation of a gallery in soft sedimentary rocks in the Horonobe area of Japan.Detailed fracture mapping of the gallery indicates that the fractures consist of both pre-existing shear fractures and excavation damaged zone(EDZ) fractures. EDZ fractures correspond to weak planes associated with bedding planes or transgranular cracks.The EDZ fractures terminate against pre-existing shear fractures.Therefore,even for excavations in soft sedimentary rocks,formation of the EDZ fractures are controlled by pre-existing fractures and earlier weak planes. 相似文献
6.
Fluid inclusions in quartz from miarolitic cavities, pegmatites, and quartz veins in Miocene biotite-granite plutons, Kofu, Japan, were analyzed by particle-induced X-ray emission to examine chemistries and behaviors of granite-derived fluids in island-arc granite. Most inclusions are aqueous two-phase inclusions, and halite-bearing polyphase inclusions are also observed in quartz veins in the upper part of the plutons. From element contents of fluid inclusions in the miarolitic cavities, the original fluid released from the granite plutons during solidification is inferred to have concentrations of Mn, Fe, Cu, Zn, Ge, Br, Rb, Pb, and Ba of several tens to hundreds of parts per million by weight (ppm) and a salinity of about 10 wt% NaCl equivalent. We estimated the formation conditions of the fluid to have been at about 1.3–1.9 kb and 530–600°C on the basis of the homogenization temperatures of the inclusions and the solidification conditions of the plutons. The polyphase inclusions probably originated from hypersaline fluid by boiling of part of the released fluid during its ascent in the plutons. The polyphase inclusions contain several hundreds to tens of thousands of ppm of Fe and Mn, and tens to several hundreds of ppm of Cu, Zn, Br, Rb, and Pb. The salinities are about 35 wt% NaCl equivalent. Compositional variations in two-phase inclusions from the miarolitic cavities and quartz veins are primarily explained by mineral precipitation with dilution by surface water exerting a secondary influence. Thus, chemistries and behaviors of the granite-derived fluids in the plutons can be explained by mineral precipitation, boiling, and dilution of the originally released fluid. 相似文献
7.
Masanori Kurosawa Kunihiro Shima Satoshi Ishii Kimikazu Sasa 《Geostandards and Geoanalytical Research》2006,30(1):17-30
The concentrations of fifty trace elements, including relatively volatile elements and transition metal elements, in fused glasses of Geological Survey of Japan rock reference materials GSJ JR-2, JA-1, JA-2, JB-1a, JB-3, JGb-1 and JF-1 were determined by particle (proton) induced X-ray emission (PIXE) and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). The fused glasses were prepared by rapid fusion and subsequent quenching in welded platinum capsules and were found to be homogeneous for major elements and for trace elements with concentrations of more than 1 μg g-1 within the observed precision (± 10% mean) on a 70 μm sampling scale. The values obtained by PIXE and LA-ICP-MS for the transition elements (Cr, Mn, Fe, Ni and Cu), the relatively volatile elements (Zn, Ga, Rb and Pb) and the refractory elements (Y, Zr, Nb and Th) with concentrations greater than a few μg g-1 showed good agreement (within 10 % relative difference). The values for almost all the elements detected at concentrations higher than 1 μg g-1 as determined by LA-ICP-MS also agreed well with the reference values (mean relative difference < ± 10%), except for B and Cu. The good agreement confirmed the appropriateness of the NIST SRM 600 series glass calibration reference material for LA-ICP-MS analysis of glasses with variable major-element compositions for almost all elements. The concentrations of Cu in all the samples were lower than the reference values, which was attributed to adsorption of the transition metals onto the platinum capsule during preparation. 相似文献
8.
该文考虑生命活动与物质交换和能量流动的关系,从热力学出发,引入一维能量模型。在一维能量模型的基础上,将水稻对外界能量的摄取能力与水稻生长季中的气温变化规律联系起来,建立在气温变化条件下水稻的生长模型。结合气温增长率、水稻最适气温和不同阶段的生物量,以徐士良单形调优算法为基础,利用Forcal二维方程参数拟合,得到关于水稻自然增长率、气温波幅和初始值等参数的最优拟合。将最优拟合数据代入水稻的生长模型,拟合得到水稻的生长曲线和水稻生长随气温的变化趋势。以水稻的生长模型为基础,定性分析水稻的临界气温和最大生长率出现时间。通过分析发现,水稻生长季的临界气温与气温增长率无关;水稻的最大生长率出现时间为水稻分蘖后期、孕穗期。为考虑异常气温对水稻生长的影响,利用Matlab对水稻分蘖期低温和生殖生长期高温的水稻生长进行模拟,结果表明:水稻后期高温对产量影响比前期受低温影响严重。 相似文献
9.
Several procedures for non-linear static and dynamic analysis of structures have been developed in recent years. This paper
discusses those procedures that have been implemented into the latest European and US seismic provisions: non-linear dynamic
time-history analysis; N2 non-linear static method (Eurocode 8); non-linear static procedure NSP (FEMA 356) and improved capacity
spectrum method CSM (FEMA 440). The presented methods differ in respect to accuracy, simplicity, transparency and clarity
of theoretical background. Non-linear static procedures were developed with the aim of overcoming the insufficiency and limitations
of linear methods, whilst at the same time maintaining a relatively simple application. All procedures incorporate performance-based
concepts paying more attention to damage control. Application of the presented procedures is illustrated by means of an example
of an eight-storey reinforced concrete frame building. The results obtained by non-linear dynamic time-history analysis and
non-linear static procedures are compared. It is concluded that these non-linear static procedures are sustainable for application.
Additionally, this paper discusses a recommendation in the Eurocode 8/1 that the capacity curve should be determined by pushover
analysis for values of the control displacement ranging between zero and 150% of the target displacement. Maximum top displacement
of the analyzed structure obtained by using dynamic method with real time-history records corresponds to 145% of the target
displacement obtained using the non-linear static N2 procedure. 相似文献
1