排序方式: 共有11条查询结果,搜索用时 15 毫秒
11.
The method for determining Pco2 in the atmosphere and water by using gas chroma-tography was studied. For determination of Pco2 in the atmosphere, a sampling method was developed in which the chromatograph was connected to a 6-port valve with a sampling pipe opening to the atmosphere, so gas pressure in the sampling pipe was identical to that of the atmoesphere. A semi-automatic seawater-atmosphere equilibrium system was designed to determine the Pco2 in seawater. The equilibrium chamber contained in situ seawater and the well-equilibrated gas was pushed into the sampling pipe by sample wa-ter, so pressure and temperature calibration could be avoided. This method has high accuracy for the de-termination of Pco2 in the air and seawater, and was used for in situ determination of Pco2 in the atmo-sphere and of the seawater sample in the JGOFS cruise in the East China Sea. 相似文献