The design of a drainage system for a roofing slate quarry was implemented by the enhancement of discharge peak estimation, and the uncertainty inevitably associated with the engineering model was reduced.
The development of a topographical, geological, and vegetation cover database developed from a Geographical Information System (GIS) allowed for the definition of the drainage network for a hydraulic system, along with the calculation of the runoff coefficient. This is applied to the digital model of accumulated flow (DMF) as a weight correction coefficient, using a matrix-based model at 5×5 m resolution. The new digital model of corrected accumulated flow (DMCF) is the result of combining the thematic maps with the map of slope <3%, which was previously created from the slope model. It is demonstrated that this new model allows to apply the “Rational Method” on cartographic units defined by the GIS.
The DMCF is compared with other traditional applications of the Rational Method based on the calculation of the discharge peak considering: (1) the drainage basin as a single watershed or (2) defining an average runoff coefficient in each sub-watershed. Both approaches have bigger discharge peaks than those obtained by the DMCF since the slope, lithology, and vegetation cover have average values, and the runoff coefficient is poorly defined, increasing the uncertainty in the discharge peak. 相似文献
Accidental spills of hydrocarbons, such as Light Non-Aqueous Phase Liquids (LNAPLs), are one of the most common sources of subsurface contamination. Migration of LNAPL in a porous medium is influenced by various factors such as the number of fluids present in the unsaturated/saturated zones and the proportion of pores occupied by each fluid. The results for relationship between matric suction and degree of saturation are presented in this paper for water–air, water–LNAPL and LNAPL–air systems in a sand. A simple and reliable setup using Buchner funnel was designed to obtain these relations. It was found that the relationship between matric suction head and degree of saturation is hysteretic for all the fluid systems (water–air, water–LNAPL and LNAPL–air). Furthermore, the amount of hysteresis depended upon the fluid system, with the maximum hysteresis occurring for water–air system. The results suggest that the amount of trapped air depends upon the reversal degree of saturation from drying to wetting. 相似文献
Rebuilding of victims' livelihoods was a crucial issue in the restoration process in the1995 Hanshin-Awaji Earthquake Disaster. Housing damage assessment influencedmost of the rebuilding of the livelihood in the long term, because the Victim Certificatesissued by the local governments based on the results of the Housing damage assessmentwas required to receive most of the individual assistance measures. In the process ofHousing damage assessment, many complex problems arose, leading to extensivework on the part of the disaster responders. Consequently, a considerable number ofvictims were dissatisfied with the assessment and applied for a resurvey. Due to a floodof requests for resurvey, disaster responders had to work on damage assessment, leavingrelief activities aside.In order to facilitate Housing damage assessment, this paper discusses thefollowing five points: (1) the processes and the problems of assessments performedin the Hanshin-Awaji Earthquake Disaster, (2) the changes in the nature of informationneeded by the victims, (3) the improvements over the present damage assessment, (4)the housing situation in Japan, and (5) the international situation on damage assessment.It is obvious from the results that a poor damage assessment system and the size ofthe disaster produced a very large work load. Differences in appreciation among theinvestigators also contributed to unfair assessments and led to the victims beingincreasingly dissatisfied by the survey results. Finally, a design concept for acomprehensive damage assessment system, which has been derived from theabove five points, is proposed for post-disaster management. 相似文献
There are many thrust-related structures occurring in the Paleozoic strata of the Niushou Mountain in the central part of Ningxia Hui Autonomous Region. The fault-related folds are the typical structures in this area. Based on the analysis about these structures and their relationships, the processes by which these structures of the Miboshan Formation were formed are reconstructed, and the strata underwent about three stages of deformation: (1) horizontal shortening, (2) folding, and (3) thrusting. And the fact that the Niushou Mountain is the leading edge of an old thrust sheet was proved, the Niushou Mountain, the Daluo Mountain and the Xiaoluo Mountain together constitute the front part of this old thrust zone, so the Niushou Mountain and the Ordovician strata in the central and southern parts of Ningxia now are likely allochthons. In the period from middle Ordovician to Devonian, the areas of the central and southern Ningxia belonged to the back-arc foreland basin of North Qilianshan orogen, which was adjacent to the continent in the north. In the later part of the early Paleozoic period, the Niushou Mountain was formed after the closure of the back-arc foreland basin. 相似文献
Abstract. Magnetotelluric (MT) surveys were carried out around the Muine volcano, Hokkaido, Japan, where it is expected that the heat and metal source forming the polymetallic Ag-Pb-Zn-Cu-In Toyoha deposit is present at depth. Measurements were performed at 20 sites, 18 of which were located along a WSW-ENE profile traversing the north ridge of Mt. Muine. A resistivity model obtained from 2D inversion of the MT data shows subsurface specific conductive and resistive features. Conductive layers are present at the surface of Mt. Muine. The low resistivity is probably due to the clay-rich rocks associated with the hydrothermal alteration. A high resistivity layer, which corresponds to the pre-Tertiary Usubetsu Formation, crops out east of Mt. Muine and dips westward. At the west foot of Mt. Muine, relatively high resistive layers are widely exposed. The resistivity increases with depth and exceeds 1000 ohm-m. This fact indicates that this region is not influenced by the recent hydrothermal activity. An extremely conductive zone about 3–6 km wide and 6–9 km thick exists at a depth of 2 km below Mt. Muine. This zone mostly corresponds to an elastic wave attenuation zone detected by a seismic survey. It is interpreted as a large hydrothermal reservoir or melted magma, which is a heat source of the hydrothermal system in this area. 相似文献