Abstract. Evolution of hydrothermal system from initial porphyry Cu mineralization to overlapping epithermal system at the Dizon porphyry Cu‐Au deposit in western central Luzon, Zambales, Philippines, is documented in terms of mineral paragen‐esis, fluid inclusion petrography and microthermometry, and sulfur isotope systematics. The paragenetic stages throughout the deposit are summarized as follows; 1) stockwork amethystic quartz veinlets associated with chalcopyrite, bornite, magnetite and Au enveloped by chlorite alteration overprinting biotite alteration, 2) stockwork quartz veinlets with chalcopyrite and pyrite associated with Au and chalcopyrite and pyrite stringers in sericite alteration, 3) stringer quartz veinlets associated with molybdenite in sericite alteration, and 4) WNW‐trending quartz veins associated with sphalerite and galena at deeper part, while enargite and stibnite at shallower levels associated with advanced argillic alteration. Chalcopyrite and bornite associated with magnetite in quartz veinlet stockwork (stage 1) have precipitated initially as intermediate solid solution (iss) and bornite solid solution (bnss), respectively. Fluid inclusions in the stockwork veinlet quartz consist of gas‐rich inclusions and polyphase inclusions. Halite in polyphase inclusions dissolves at temperatures ranging from 360d?C to >500d?C but liquid (brine) and gas (vapor) do not homogenize at <500d?C. The maximum pressure and minimum temperature during the deposition of iss and bnss with stockwork quartz veinlets are estimated to be 460 bars and 500d?C. Fluid inclusions in veinlet stockwork quartz enveloped in sericite alteration (stage 2) consist mainly of gas‐rich inclusions and polyphase inclusions. In addition to the possible presence of saturated NaCl crystals at the time of entrapment of fluid inclusions that exhibit the liquid‐vapor homogenization temperatures lower than the halite dissolution temperatures in some samples, wide range of temperatures of halite dissolution and liquid‐vapor homogenization of polyphase inclusions from 230d?C to >500d?C and from 270d?C to >500d?C, respectively, suggests heterogeneous entrapment of gaseous vapor and hypersaline brine. The minimum pressure and temperature are estimated to be about 25 bars and 245d?C. Fluid inclusions in veinlet quartz associated with molybdenite (stage 3) are dominated by gas‐rich inclusions accompanied with minor liquid‐rich inclusions that homogenize at temperatures between 350d?C and 490d?C. Fluid inclusions in vuggy veinlet quartz associated with stibnite (stage 4) consist mainly of gas‐rich inclusions with subordinate polyphase inclusions that do not homogenize below 500d?C. Fluid inclusions in veinlet quartz associated with galena and sphalerite (stage 4) are composed of liquid‐rich two‐phase inclusions, and they homogenize into liquid phase at temperatures ranging widely from 190d?C to 300d?C (suggesting boiling) and the salinity ranges from 1.0 wt% to 3.4 wt% NaCl equivalent. A pressure of about 15 bars is estimated for the dilute aqueous solution of 190d?C from which veinlet quartz associated with galena and sphalerite precipitated. In addition to a change in temperature‐pressure regime from lithostatic pressure during the deposition of iss and bnss with stockwork quartz veinlets to hydrostatic pressure during fracture‐controlled quartz veinlet associated with galena and sphalerite, a decrease in pressure is supposed to have occurred due to unroofing or removal of the overlying piles during the temperature decrease in the evolution of hydrothermal system. The majority of the sulfur isotopic composition of sulfides ranges from ±0 % to +5 %. Sulfur originated from an iso‐topically uniform and homogeneous source, and the mineralization occurred in a single hydrothermal system. 相似文献
This paper presents the findings from a study on gravity-induced slope deformations along the northern slope of Mt. Nuria (Rieti-Italy). The slope extends from the village of Pendenza to the San Vittorino plain and hosts the Peschiera River springs, i.e. the most important springs of the Central Apennines (average discharge: about 18 m3/s).
Detailed geological-geomorphological and geomechanical surveys, supported by a site stress-strain monitoring system and laboratory tests, led us to define the main evolutionary features of the studied phenomena. Based on the collected data, a “geological-evolutionary model” was developed with a view to identifying a spatio-temporal correlation between relief forms, jointing of the rock mass and its stress conditions. The geological-evolutionary model was expected to improve numerical simulations and to test our assumptions.
The numerical model also allowed us to simulate changes in the stress-strain conditions of the rock mass and correlate them with jointing, seepage, as well as with site-detected and site-monitored forms and deformations. In particular, significant relations between seepage, tensile stresses within the rock mass, karst solution and collapse of cavities were identified. 相似文献
The intensive agricultural and economic activities induce the increase of the risk of groundwater quality degradation through high groundwater pumping rates. The salinization and contamination are the main sources of this pollution, especially in coastal aquifers. The explanation of the origin of salinity for the shallow aquifer of Northern Sahel of Sfax was analysed by a chemical study of the groundwater main compounds. The partitioning of groundwaters into homogenous groups is undertaken by graphical techniques, including a Stiff pattern diagram, an expanded Durov diagram and several binary diagrams. The study indicates the presence of various salinization processes. In the recharge area, salinization is the result of dissolution/precipitation of the aquifer formation material (group I). The irrigation water return and the intensive pumping have been identified as major sources of salinization in the south by direct cation exchange and mixing reactions (groups II and III). The anomaly of high groundwater salinity observed near the Hazeg zone was explained by the presence of a seawater intrusion in this area. This hypothesis is related to the high chloride concentration, to the presence of inverse cation exchange reactions (group IV), and to the piezometric level inferior to sea level. To cite this article: R. Trabelsi et al., C. R. Geoscience 337 (2005).相似文献
A multi-layered aquifer, typical of riverbank alluvial deposits in Korea, was studied to determine the hydrologic properties.
The geologic logging showed that the subsurface of the study site was comprised of four distinctive hydrogeologic units: silt,
sand, highly weathered and fresh bedrock layers. The electrical resistivity survey supplied information on lateral extension
of hydrogeologic strata only partially identified by a limited number of the geologic loggings. The laboratory column tracer
test for the recovered core of the sand layer resulted in a hydraulic conductivity of 5.00×10−2 cm/s. The slug tests performed in the weathered rock layer yielded hydraulic conductivities of 4.32–7.72×10−4 cm/s. Hydraulic conductivities for the sand layer calculated from the breakthrough curves of bromide ranged between 2.08×10−3 and 2.44×10−2 cm/s with a geometric mean of 6.89×10−3 cm/s, which is 7 times smaller than that from the laboratory column experiment. The trend of increasing hydraulic conductivity
with an increase in tracer travel length is likely a result of the increased likelihood of encountering a high conductivity
zone as more of the aquifer is tested. The combined hydrogeologic site characterization using hydraulic tests, tracer tests,
and column test with geologic loggings and geophysical survey greatly enhanced the understanding of the hydrologic properties
of the multi-layered alluvial aquifer. 相似文献
Composite granite–quartz veins occur in retrogressed ultrahigh pressure (UHP) eclogite enclosed in gneiss at General's Hill in the central Sulu belt, eastern China. The granite in the veins has a high‐pressure (HP) mineral assemblage of dominantly quartz+phengite+allanite/epidote+garnet that yields pressures of 2.5–2.1 GPa (Si‐in‐phengite barometry) and temperatures of 850–780°C (Ti‐in‐zircon thermometry) at 2.5 GPa (~20°C lower at 2.1 GPa). Zircon overgrowths on inherited cores and new grains of zircon from both components of the composite veins crystallized at c. 221 Ma. This age overlaps the timing of HP retrograde recrystallization dated at 225–215 Ma from multiple localities in the Sulu belt, consistent with the HP conditions retrieved from the granite. The εHf(t) values of new zircon from both components of the composite veins and the Sr–Nd isotope compositions of the granite consistently lie between values for gneiss and eclogite, whereas δ18O values of new zircon are similar in the veins and the crustal rocks. These data are consistent with zircon growth from a blended fluid generated internally within the gneiss and the eclogite, without any ingress of fluid from an external source. However, at the peak metamorphic pressure, which could have reached 7 GPa, the rocks were likely fluid absent. During initial exhumation under UHP conditions, exsolution of H2O from nominally anhydrous minerals generated a grain boundary supercritical fluid in both gneiss and eclogite. As exhumation progressed, the volume of fluid increased allowing it to migrate by diffusing porous flow from grain boundaries into channels and drain from the dominant gneiss through the subordinate eclogite. This produced a blended fluid intermediate in its isotope composition between the two end‐members, as recorded by the composite veins. During exhumation from UHP (coesite) eclogite to HP (quartz) eclogite facies conditions, the supercritical fluid evolved by dissolution of the silicate mineral matrix, becoming increasingly solute‐rich, more ‘granitic’ and more viscous until it became trapped. As crystallization began by diffusive loss of H2O to the host eclogite concomitant with ongoing exhumation of the crust, the trapped supercritical fluid intersected the solvus for the granite–H2O system, allowing phase separation and formation of the composite granite–quartz veins. Subsequently, during the transition from HP eclogite to amphibolite facies conditions, minor phengite breakdown melting is recorded in both the granite and the gneiss by K‐feldspar+plagioclase+biotite aggregates located around phengite and by K‐feldspar veinlets along grain boundaries. Phase equilibria modelling of the granite indicates that this late‐stage melting records P–T conditions towards the end of the exhumation, with the subsolidus assemblage yielding 0.7–1.1 GPa at <670°C. Thus, the composite granite–quartz veins represent a rare example of a natural system recording how the fluid phase evolved during exhumation of continental crust. The successive availability of different fluid phases attending retrograde metamorphism from UHP eclogite to amphibolite facies conditions will affect the transport of trace elements through the continental crust and the role of these fluids as metasomatic agents interacting with the mantle wedge in the subduction channel. 相似文献