High‐T, low‐P metamorphic rocks of the Palaeoproterozoic central Halls Creek Orogen in northern Australia are characterised by low radiogenic heat production, high upper crustal thermal gradients (locally exceeding 40 °C km?1) sustained for over 30 Myr, and a large number of layered mafic‐ultramafic intrusions with mantle‐related geochemical signatures. In order to account for this combination of geological and thermal characteristics, we model the middle crustal response to a transient mantle‐related heat pulse resulting from a temporary reduction in the thickness of the mantle lithosphere. This mechanism has the potential to raise mid‐crustal temperatures by 150–400 °C within 10–20 Myr following initiation of the mantle temperature anomaly, via conductive dissipation through the crust. The magnitude and timing of maximum temperatures attained depend strongly on the proximity, duration and lateral extent of the thermal anomaly in the mantle lithosphere, and decrease sharply in response to anomalies that are seated deeper than 50–60 km, maintained for <5 Myr in duration and/or have half‐widths <100 km. Maximum temperatures are also intimately linked to the thermal properties of the model crust, primarily due to their influence on the steady‐state (background) thermal gradient. The amplitudes of temperature increases in the crust are principally a function of depth, and are broadly independent of crustal thermal parameters. Mid‐crustal felsic and mafic plutonism is a predictable consequence of perturbed thermal regimes in the mantle and the lowermost crust, and the advection of voluminous magmas has the potential to raise temperatures in the middle crust very quickly. Although pluton‐related thermal signatures significantly dissipate within <10 Myr (even for very large, high‐temperature intrusive bodies), the interaction of pluton‐ and mantle‐related thermal effects has the potential to maintain host rock temperatures in excess of 400–450 °C for up to 30 Myr in some parts of the mid‐crust. The numerical models presented here support the notion that transient mantle‐related heat sources have the capacity to contribute significantly to the thermal budget of metamorphism in high‐T, low‐P metamorphic belts, especially in those characterised by low surface heat flow, very high peak metamorphic geothermal gradients and abundant mafic intrusions. 相似文献
Geothermal gradients are estimated to vary from 31 to 43 °C/km in the Yinggehai Basin based on 99 temperature data sets compiled from oil well data. Thirty-seven thermal conductivity measurements on core samples were made and the effects of porosity and water saturation were corrected. Thermal conductivities of mudstone and sandstone range from 1.2 to 2.7 W/m K, with a mean of 2.0±0.5 W/m K after approximate correction. Heat flow at six sites in the Yinggehai Basin range from 69 to 86 mW/m2, with a mean value of 79±7 mW/m2. Thick sediments and high sedimentation rates resulted in a considerable radiogenic contribution, but also depressed the heat flow. Measurements indicate the radiogenic heat production in the sediment is 1.28 μW/m3, which contributes 20% to the surface heat flow. After subtracting radiogenic heat contribution of the sediment, and sedimentation correction, the average basal heat flow from basement is about 86 mW/m2.Three stages of extension are recognized in the subsidence history, and a kinematic model is used to study the thermal evolution of the basin since the Cenozoic era. Model results show that the peak value of basal heat flow was getting higher and higher through the Cenozoic. The maximum basal heat flow increased from 65 mW/m2 in the first stage to 75 mW/m2 in the second stage, and then 90 mW/m2 in the third stage. The present temperature field of the lithosphere of the Yinggehai Basin, which is still transient, is the result of the multistage extension, but was primarily associated with the Pliocene extension. 相似文献
Premelting effects in gehlenite (Ca2Al2SiO7) have been studied by Raman spectroscopy and calorimetry, and in gehlenite and pseudowollastonite (CaSiO3) by electrical conductivity. The enthalpy of premelting of gehlenite is 17.3 kJ mol−1 and represents 9% of the reported enthalpy of fusion, which is in the range of the reported fraction of other minerals. The
Raman and electrical conductivity experiments at high temperatures, for gehlenite and pseudowollastonite, show that the premelting
effects of both compositions are associated with enhanced dynamics of calcium atoms near the melting point. This conclusion
agrees with the results obtained for other minerals like diopside, but contrasts with those found for sodium metasilicate
in which the weaker bonding of sodium allows the silicate framework to distort near the melting temperature and deform in
such a way to prefigure the silicate entities present in the melt.
Received: 30 April 2002 / Accepted: 7 August 2002
Acknowledgements We thank Y. Linard for help with DSC measurements and two anonymous reviewers for their constructive comments. This work
has been partly supported by the EU Marie-Curie fellowship contract no. HPMF-CT-1999-00329, the CNRS-Carnegie Institution
of Washington program PICS no.192, and the NSF grants EAR-9614432 and EAR-9901886 to B.O.M. 相似文献
The permeability of sedimentary rocks during triaxial compression tests was investigated to relate it to the complete strain–stress process. It was found that the permeability was not constant, but varied with the stress and strain states in the rocks. Prior to the peak strength, the permeability decreases with increasing load. A dramatic increase in permeability occurs during the strain softening period. In the present study, in situ measurements of fluid flow and pressure in floor strata was carried out in a double longwall mining face in the Yangzhuang colliery. These measurements show that both the strata pressure and the position with respect to the mining face influence the hydrogeologic properties. The permeability increased in the floor strata behind the mining face because those mining induced fractures opened as the strata pressure decreased. To better understand this change in hydraulic behavior around the mining faces, 3-D numerical modeling was carried out. The model provides the general picture of the stress distribution and failure zone both in the floor and roof strata. The field and model results demonstrate the importance of changes in the stress and strain states on the hydrogeology of a site. 相似文献
Thermal waters hosted by Menderes metamorphic rocks emerge along fault lineaments in the Simav geothermal area. Thermal springs and drilled wells are located in the Eynal, Çitgöl and Na
a locations, which are part of the Simav geothermal field. Studies were carried out to obtain the main chemical and physical characteristics of thermal waters. These waters are used for heating of residences and greenhouses and for balneological purposes. Bottom temperatures of the drilled wells reach 163°C with total dissolved solids around 2225 mg/kg. Surface temperatures of thermal springs vary between 51°C and 90°C. All the thermal waters belong to Na–HCO3–SO4 facies. The cold groundwaters are Ca–Mg–HCO3 type. Dissolution of host rock and ion-exchange reactions in the reservoir of the geothermal system shift the Ca–Mg–HCO3 type cold groundwaters to the Na–HCO3–SO4 type thermal waters. Thermal waters are oversaturated at discharge temperatures for aragonite, calcite, quartz, chalcedony, magnesite and dolomite minerals giving rise to a carbonate-rich scale. Gypsum and anhydrite minerals are undersaturated with all of the thermal waters. Boiling during ascent of the thermal fluids produces steam and liquid waters resulting in an increase of the concentrations of the constituents in discharge waters. Steam fraction, y, of the thermal waters of which temperatures are above 100°C is between 0.075 and 0.119. Reservoir pH is much lower than pH measured in the liquid phase separated at atmospheric conditions, since the latter experienced heavy loss of acid gases, mainly CO2. Assessment of the various empirical chemical geothermometers and geochemical modelling suggest that reservoir temperatures vary between 175°C and 200°C. 相似文献
In this study, representative samples from thermal wells and springs were chemically analyzed and geothermometers were used to calculate the deep temperatures of geothermal reservoirs on the basis of water–mineral equilibrium. In some cases, however, the chemical components are not in equilibrium with the minerals in the reservoir. Therefore, log(Q/K) diagrams are used to study the chemical equilibrium for the minerals that are likely to participate. The Na–K–Mg triangular diagram is also applied to evaluate the equilibrium of water with reservoir rocks. Standard curves at the reference temperatures are prepared to reveal which type of silica geothermometer is appropriate for the specified condition. This study shows that water samples from geothermal wells W9 and W12 are in equilibrium with the selective minerals, and chalcedony may control the fluid–silica equilibrium. It is estimated that there is an exploitable low-temperature reservoir with possible temperatures of 80–90°C in the Guanzhong basin. 相似文献
A field test and analysis method has been developed to estimate the vertical distribution of hydraulic conductivity in shallow unconsolidated aquifers. The field method uses fluid injection ports and pressure transducers in a hollow auger that measure the hydraulic head outside the auger at several distances from the injection point. A constant injection rate is maintained for a duration time sufficient for the system to become steady state. Exploiting the analogy between electrical resistivity in geophysics and hydraulic flow two methods are used to estimate conductivity with depth: a half-space model based on spherical flow from a point injection at each measurement site, and a one-dimensional inversion of an entire dataset.
The injection methodology, conducted in three separate drilling operations, was investigated for repeatability, reproducibility, linearity, and for different injection sources. Repeatability tests, conducted at 10 levels, demonstrated standard deviations of generally less than 10%. Reproducibility tests conducted in three, closely spaced drilling operations generally showed a standard deviation of less than 20%, which is probably due to lateral variations in hydraulic conductivity. Linearity tests, made to determine dependency on flow rates, showed no indication of a flow rate bias. In order to obtain estimates of the hydraulic conductivity by an independent means, a series of measurements were made by injecting water through screens installed at two separate depths in a monitoring pipe near the measurement site. These estimates differed from the corresponding estimates obtained by injection in the hollow auger by a factor of less than 3.5, which can be attributed to variations in geology and the inaccurate estimates of the distance between the measurement and the injection sites at depth. 相似文献
Introduction The measurements of the compressional wave velocity and electrical conductivity of minerals and rocks are of fundamental importance to look into the earths interior, including composition, geotherm, generation and distribution of fluids and melts. Hydrous minerals formed by metamatu-siom are abundant within the earth. Previous studies have been carried out on the dehydration effect on the electrical conductivity and wave velocity of rocks such as serpentine, amphibole, most of whi… 相似文献