No other environmental variable of such ecological importance to estuarine and coastal marine ecosystems around the world has changed so drastically, in such a short period of time, as dissolved oxygen in coastal waters. The prevalent methods for counteracting anoxic sea events are indirect measures which aim to cut-down anthropic loads introduced in river and marine environments. To date, no direct approaches, like artificial devices have been investigated except the WEBAP and OXYFLUX devices. The present paper adopts a numerical approach to the analysis of the pumped surface water as well as the analysis of the dynamic response of the OXYFLUX device. By means of a CFD-RANS code and through the application of overset grid method, the 1/16 OXYFLUX model’s dynamic response and pumping performance are evaluated. The appropriate grid is selected after an extensive sensitivity analysis carried out on 9 different grids. The CFD model is validated by comparing numerical and physical results of heave decay test, heave response, and surface water discharge under the action of regular waves. The extensive comparison with experimental results shows consistently accurate predictions. The main findings of the study show that nonlinear effects remarkable reduce the dynamic behaviour of the OXYFLUX and generate an unexpected second harmonic for pitch response intensifying the overtopping discharge also for small waves caused by the summer's low intensity winds. 相似文献
3D city models, which are important items of content on the virtual globe, are characterized by complicated structures and large amounts of data. These factors make the visualization of 3D city models highly dependent upon the performance of computer hardware. Thus, achieving the efficient rendering of 3D city models using different hardware performance levels represents one of the key problems currently facing researchers. This paper proposes a time-critical adaptive visualization method that first estimates the possible rendering time for each model according to the data structure of the model in addition to the CPU/GPU performance of the computer. It then dynamically adjusts the rendering level for each model based on the results of an estimation of the rendering time to ensure that the final scene can be completed within a given time. To verify the effectiveness and flexibility of this method, it is applied using different computers. The results show that the adaptive visualization method presented in this paper not only can adapt to computers with different levels of performances but also demonstrates an obvious improvement in the time estimation precision, visual effects, and optimization speed relative to existing adaptive visualization methods. 相似文献
Renewable energy curtailment is a critical issue in China, impeding the country’s transition to clean energy and its ability to meet its climate goals. This paper analyzes the impacts of more flexible coal-fired power generation and improved power dispatch towards reducing wind power curtailment. A unit commitment model for power dispatch is used to conduct the analysis, with different scenarios demonstrating the relative impacts of more flexible coal-fired generation and improved power dispatch. Overall, while we find both options are effective in reducing wind power curtailment, we find that improved power dispatch is more effective: (1) the effect of ramping down coal-fired generators to reduce wind power curtailment lessens as the minimum output of coal-fired generation is decreased; and (2) as a result, at higher wind capacity levels, wind curtailment is much more significantly reduced with improved power dispatch than with decreased minimum output of coal-fired generation.
Key policy insights
China should emphasize both coal power flexibility and dispatch in its policies to minimize renewable power curtailment and promote clean energy transition.
China should accelerate the process of implementing spot market and marginal cost-based economic dispatch, while making incremental improvements to the existing equal share dispatch in places not ready for spot market.
A key step in improving of dispatch is incorporating renewable power forecasts into the unit commitment process and updating the daily unit commitment based on the latest forecast result.
China should expand the coal power flexibility retrofit programme and promote the further development of the ancillary service market to encourage more flexibility from coal-fired generation.
The semi-Lagrangian advection scheme is implemented on a new quasi-uniform overset (Yin-Yang) grid on the sphere. The Yin-Yang grid is a newly developed grid system in spherical geometry with two perpendicularly-oriented latitude-longitude grid components (called Yin and Yang respectively) that overlapp each other, and this effectively avoids the coordinate singularity and the grid convergence near the poles. In this overset grid, the way of transferring data between the Yin and Yang components is the key to maintaining the accuracy and robustness in numerical solutions. A numerical interpolation for boundary data exchange, which maintains the accuracy of the original advection scheme and is computationally efficient, is given in this paper. A standard test of the solid-body advection proposed by Williamson is carried out on the Yin-Yang grid. Numerical results show that the quasi-uniform Yin-Yang grid can get around the problems near the poles, and the numerical accuracy in the original semi-Lagrangian scheme is effectively maintained in the Yin-Yang grid. 相似文献