首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   9篇
  免费   3篇
地球物理   12篇
  2021年   1篇
  2016年   2篇
  2013年   1篇
  2010年   1篇
  2009年   2篇
  2008年   2篇
  2007年   1篇
  2006年   1篇
  2005年   1篇
排序方式: 共有12条查询结果,搜索用时 281 毫秒
11.
This paper presents results of a comprehensive experimental program on the seismic response of full‐scale freestanding laboratory equipment. First, quasi‐static experiments are conducted to examine the mechanical behavior of the contact interface between the laboratory equipment and floors. Based on the experimental results, the response analysis that follows adopts two idealized contact friction models: the elastoplastic model and the classical Coulomb friction model. Subsequently, the paper presents shake table test results of full‐scale freestanding equipment subjected to ground and floor motions of hazard levels with corresponding displacements that can be accommodated by the shake table at the UC Berkeley Earthquake Engineering Research Center. For the equipment tested, although some rocking is observed, sliding is the predominant mode of response, with sliding displacements reaching up to 60 cm. Numerical simulations with the proposed models are performed. Finally, the paper identifies a physically motivated intensity measure and the associated engineering demand parameter with the help of dimensional analysis and presents ready‐to‐use fragility curves. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   
12.
A building with a seismic isolation system, in an earthquake, is recognized as producing substantially smaller accelerations and deformations compared with a building that use other systems. This type of system is therefore expected to better protect the building's nonstructural components, equipment, and other contents that are essential for the activities conducted in the building. Unlike many available studies on building responses, only a small number of studies on a buildings' nonstructural component responses are available, and no study has directly addressed building performance with regard to nonstructural component protection. This paper therefore measures the performance of various seismically isolated buildings. Specifically, the effects of important structural parameters, namely, isolation stiffness, isolation damping ratio, and number of stories on the response of base‐isolated structures are investigated parametrically. Ground motions with 2% exceedence in 50years Maximum Considered Earthquake (MCE) are used. Performance is compared with that of fixed‐base structures in order to present data that will be useful in justifying the more costly technology. The buildings are 3, 9, and 20 stories, represented by MDOF shear‐beam models. As examples of displacement‐sensitive and acceleration‐sensitive components, partition walls and ceilings are considered, respectively. The Pacific Earthquake Engineering Research Center performance‐based earthquake engineering methodology is adopted to evaluate the failure return periods of the examples based on their available fragility curves. In addition, the curves are varied hypothetically to understand the sensitivity of the return period to the curve features. Then, the median and dispersion of fragility curves required to satisfy the components' desired failure return period are obtained. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号