By utilizing observational data from a 325 m tower of the Institute of Atmospheric Physics (IAP), Chinese Academy of Sciences (CAS) on March 19-29, 2001 and August 11-25, 2003, a comprehensive study was conducted on the vertical dynamical and thermodynamic characteristics of the urban lower boundary layer (ULBL) and its relationship with aerosol concentration over Beijing. Firstly, a comparative analysis was made on the gradient data (wind, temperature and humidity), ultrasonic data (atmospheric turbulences) and air-quality observations at different tower heights (47, 120 and 280 m). Secondly, a diagnosis was made to reveal the major features of normalized variances of velocity and temperature, turbulence kinetic energy as well as their relationship with aerosol concentrations. Furthermore, the characteristics of the ULBL vertical structure and the TSP concentration/distribution variations during a sand/dust weather process were also analyzed. The outcome of the study showed that under unstable stratification, the normalized variances of velocity (σu/u*, σv/u*, σw/u*) and temperature (σT/T*) at 47 and 120 m heights fit the Monin-Obukhov similarity (MOS) framework and the fitting formulas were given out accordingly. According to the stratification parameter (z′/L), the stable ULBL could be divided into 2 zones. With z′/L<0.1, it was a weakly stable zone and MOS framework was applicable. The other was a highly stable zone with z′/L>0.1 and the normalized velocity variances tended to increase along with higher stability, but it remained constant for normalized temperature variances. At daytime, the near-surface layer includes two heights of 47 and 120 m, while 280 m has been above it. The ULBL analysis in conjunction with a sand/dust weather process in Beijing in March 2001 indicated that the maximum concentration of Total Suspended Particulates (TSP) at 320 m reached 913.3 μg/m3 and the particles were transported from the upper to lower ULBL, which was apparently related to the development process of a low-level jet and its concomitant strong sinking motion. 相似文献
Active tectonics in a basin plays an important role in controlling a fluvial system through the change in channel slope. The Baghmati, an anabranching, foothills-fed river system, draining the plains of north Bihar in eastern India has responded to ongoing tectonic deformation in the basin. The relatively flat alluvial plains are traversed by several active subsurface faults, which divide the area in four tectonic blocks. Each tectonic block is characterized by association of fluvial anomalies viz. compressed meanders, knick point in longitudinal profiles, channel incision, anomalous sinuosity variations, sudden change in river flow direction, river flow against the local gradient and distribution of overbank flooding, lakes, and waterlogged area. Such fluvial anomalies have been identified on the repetitive satellite images and maps and interpreted through DEM and field observations to understand the nature of vertical movements in the area. The sub-surface faults in the Baghmati plains cut across the river channel and also run parallel which have allowed us to observe the effects of longitudinal and lateral tilting manifested in avulsions and morphological changes. 相似文献
Most pingos in the permafrost region of the high northern Tibetan Plateau form along active fault zones and many change position annually along the zones and thus appear to migrate. The fault zones conduct geothermal heat, which thins permafrost, and control cool to hot springs in the region. They maintain ground-water circulation through broken rock in an open system to supply water for pingo growth during the winter in overlying fluvial and lacustrian deposits. Springs remain after the pingos thaw in the summer. Fault movement, earthquakes and man's activities cause the water pathways supplying pingos to shift and consequently the pingos migrate.
The hazard posed to the new Golmud–Lhasa railway across the plateau by migrating pingos is restricted to active fault zones, but is serious, as these zones are common and generate large earthquakes. Pingos have damaged the highway and the oil pipeline adjacent to the railway since 2001. One caused tilting and breaking of a bridge pier and destroyed a highway bridge across the Chumaerhe fault. Another has already caused minor damage to a new railway bridge. Furthermore, the construction of a bridge pier in the North Wuli fault zone in July–August 2003 created a conduit for a new spring, which created a pingo during the following winter. Measures taken to drain the ground-water via a tunnel worked well and prevented damage before the railway tracks were laid. However, pier vibrations from subsequent train motion disrupted the drain and led to new springs, which may induce further pingo growth beneath the bridge.
The migrating pingos result from active fault movement promoting artesian ground-water circulation and changing water pathways under the seasonal temperature variations in the permafrost region. They pose a serious hazard to railway construction, which, in turn can further disturb the ground-water conduits and affect pingo migration. 相似文献
In this study, hydrogen sulfide (H2S) measurements in air carried out using (a) passive/diffusive samplers (Radiello® traps) and (b) a high-frequency (60 s) real-time analyzer (Thermo® 450i) were compared in order to evaluate advantages and limitations of the two techniques. Four different sites in urban environments (Florence, Italy) and two volcanic areas characterized by intense degassing of H2S-rich fluids (Campi Flegrei and Vulcano Island, Italy) were selected for such measurements. The concentrations of H2S generally varied over 5 orders of magnitude (from 10−1–103 μg/m3), the H2S values measured with the Radiello® traps (H2SR) being significantly higher than the average values measured by the Thermo® 450i during the trap exposure (H2STa), especially when H2S was <30 μg/m3. To test the reproducibility of the Radiello® traps, 8 passive/diffusive samplers were contemporaneously deployed within an 0.2 m2 area in an H2S-contaminated site at Mt. Amiata (Tuscany, Italy), revealing that the precision of the H2SR values was ±49%. This large uncertainty, whose cause was not recognizable, is to be added to that related to the environmental conditions (wind speed and direction, humidity, temperature), which are known to strongly affect passive measurements. The Thermo® 450i analyzer measurements highlighted the occurrence of short-term temporal variations of the H2S concentrations, with peak values (up to 5732 μg/m3) potentially harmful to the human health. The Radiello® traps were not able to detect such temporal variability due to their large exposure time. The disagreement between the H2SR and H2STa values poses severe concerns for the selection of an appropriate methodological approach aimed to provide an accurate measurement of this highly toxic air pollutant in compliance with the WHO air quality guidelines. Although passive samplers may offer the opportunity to carry out low-cost preliminary surveys, the use of the high-frequency H2S analyzer is preferred when an accurate assessment of air quality is required. In fact, the latter provides precise real-time measurements for a reliable estimation of the effective exposure to hazardous H2S concentrations, giving insights into the mechanisms regulating the dispersion of this air pollutant in relation to the meteorological parameters. 相似文献