The current study sought to offer guidance for developing effective web-based mapping tools for wildfire warnings by identifying (1) the important content for facilitating individuals’ decision-making, and (2) the optimal interface design for ensuring usability and ease of information access. A map-based warning tool was prototyped in the Australian context, followed by a usability and effectiveness evaluation through individual interviews and verbal protocol analysis to assess participants’ interaction with the mapping interface and information in response to the simulated warning scenario. The results demonstrated variations in participants’ approaches to wildfire warning response, revealing varied information needs. Specifically, most participants relied on their own assessment of the prospective threat, requiring specific wildfire-related information before eliciting a response. In contrast, the decision of a minority of the participants was motivated by response guidance from agencies, and accurate wildfire information was less important for their response. Imperative information for both types of residents therefore needs to be highlighted in a map-based warning tool to cater to a wide audience. Furthermore, a number of heuristics were identified for designing effective interactive functions to facilitate the control of, and access to, the various maps and textual information presented on the map-based warning interface. 相似文献
This paper studies negative bias temperature instability (NBTI) under alternant and alternating current (AC) stress. Under alternant stress, the degradation smaller than that of single negative stress is obtained. The smaller degradation is resulted from the recovery of positive stress. There are two reasons for the recovery. One is the passivation of H dangling bonds, and another is the detrapping of charges trapped in the oxide. Under different frequencies of AC stress, the parameters all show regular degradation, and also smaller than that of the direct current stress. The higher the frequency is, the smaller the degradation becomes. As the negative stress time is too small under higher frequency, the deeper defects are hard to be filled in. Therefore, the detrapping of oxide charges is easy to occur under positive bias and the degradation is smaller with higher frequency. 相似文献
The saddle dolomites occur more intensely in cores closely to fault than that in cores far away from the fault in Upper Cambrian carbonate of western Tarim basin, suggesting that formation of the saddle dolomites is likely related to fault-controlled fluid flow. They partially fill in fractures and vugs of replacement dolomite. The saddle dolomites exhibit complex internal textures, commonly consisting of core and cortex. In comparison with the matrix dolomites, the saddle dolomites show lower Sr-content and 87Sr/86Sr ratios, higher Fe- and Mn-content, and more negative δ18O values. Combined with high Th (100–130 °C) of primary fluid inclusions, it is suggested that the saddle dolomites precipitated from hydrothermal fluid derived from the deep evaporite-bearing Middle Cambrian strata, and the magnesium source may be due to dissolution of host dolomite during hydrothermal fluid migration. Fault activity resulted in petrographic and geochemical difference of the core and cortex of the saddle dolomites. The cores precipitated from the formation water mixed by deep brines at the early stage of fault activity, and the cortexes precipitated from the deep fluid with higher temperatures through the Middle Cambrian later. In summary, the formation of the saddle dolomites implies a hydrothermal fluid event related to fault activity, which also resulted in high porosity in Upper Cambrian carbonate in western Tarim Basin. 相似文献
SARAL/AltiKa has a Dual Frequency Microwave Radiometer (DFMR), and Jason-2 has an Advanced Microwave Radiometer (AMR). Both microwave radiometer sensors include a 23.8 GHz primary water sensing channel. The measurement consistencies between DFMR and AMR are important for establishing a consistent altimetry data set between SARAL/AltiKa and Jason-2 in order to accurately assess sea level rise in a long-term time series. This study investigates the measurement consistency in the 23.8 GHz channel between DFMR and AMR at the Simultaneous Nadir Overpasses (SNO's) between the two satellites and also at coldest ocean brightness temperature locations. Preliminary results show that while both instruments show no significant trends over the one year since the launch of SARAL, a consistent relative bias of 2.88 K (DFMR higher than AMR) with a standard deviation of 0.98 K is observed. The relative bias at the lowest brightness temperature from the SNO method (-3.82 K) is consistent with that calculated from coldest ocean method (-3.74 K). The relative bias exhibits strong latitude (and scene temperature) dependency, changing from -3.82 K at high latitudes to -0.92 K near the equator. There also exists an asymmetry between the northern and southern hemisphere. The relative bias increases toward the lower end of brightness temperature. 相似文献
During the self-weight penetration process of the suction foundation on the dense sand seabed, due to the shallow penetration depth, the excess seepage seawater from the outside to the inside of the foundation may cause the negative pressure penetration process failure. Increasing the self-weight penetration depth has become an important problem for the safe construction of the suction foundation. The new suction anchor foundation has been proposed, and the self-weight penetration characteristics of the traditional suction foundation and the new suction anchor foundation are studied and compared through laboratory experiments and analysis. For the above two foundation types, by considering five foundation diameters and two bottom shapes, 20 models are tested with the same penetration energy. The effects of different foundation diameters on the penetration depth, the soil plug characteristics, and the surrounding sand layer are studied. The results show that the penetration depth of the new suction foundation is smaller than that of the traditional suction foundation. With the same penetration energy, the penetration depth of the suction foundation becomes shallower as the diameter increases. The smaller the diameter of the suction foundation, the more likely it is to be fully plugged, and the smaller the height of the soil plug will be. In the stage of self-weight penetration, the impact cavity appears around the foundation, which may affect the stability of the suction foundation.