排序方式: 共有36条查询结果,搜索用时 203 毫秒
31.
Comparison of Stainless Steel vs. PTFE Miniwells for Monitoring Halogenated Organic Solute Transport
Gino C. Bianchi-Mosquera Douglas M. Mackay 《Ground Water Monitoring & Remediation》1992,12(4):126-131
Field tests of organic solute transport behavior have often been monitored using small-diameter wells (miniwells). To determine if experimental results could be significantly biased by sorption to, desorption from, or diffusion through sampling lines, dissolved concentrations of tetrachloroethene and carbon tetrachloride were measured in ground water samples collected simultaneously from the same spatial location during a forced-gradient test in the Borden aquifer using polytetrafluoroethene (PTFE) and stainless steel miniwells (1/8-inch O.D.).
A semiautomated organic analytical system was used on-site to obtain real-time results, which avoided sample holding problems and permitted optimizing sampling times. The breakthrough curves (plots of concentration vs. time) for both organic compounds indicate that under the conditions of this experiment (low organic solute concentrations, short exposure time of sampling lines to the plume, adequate flushing of sampling lines) there is no significant difference between concentration histories (breakthrough curves) collected using a polytetrafluoroethene sampling line and those collected using a stainless steel sampling line. This suggests that organic solute tailing seen in this and also in a similar transport experiment previously conducted at the site is the result of transport processes in the aquifer rather than an artifact introduced by the PTFE miniwells. 相似文献
A semiautomated organic analytical system was used on-site to obtain real-time results, which avoided sample holding problems and permitted optimizing sampling times. The breakthrough curves (plots of concentration vs. time) for both organic compounds indicate that under the conditions of this experiment (low organic solute concentrations, short exposure time of sampling lines to the plume, adequate flushing of sampling lines) there is no significant difference between concentration histories (breakthrough curves) collected using a polytetrafluoroethene sampling line and those collected using a stainless steel sampling line. This suggests that organic solute tailing seen in this and also in a similar transport experiment previously conducted at the site is the result of transport processes in the aquifer rather than an artifact introduced by the PTFE miniwells. 相似文献
32.
Enhanced Degradation of Dissolved Benzene and Toluene Using a Solid Oxygen-Releasing Compound 总被引:6,自引:0,他引:6
Gino C. Bianchi-Mosquera Richelle M. Allen-King Douglas M. Mackay 《Ground Water Monitoring & Remediation》1994,14(1):120-128
A field lest to evaluate the applicability of an oxygon-releasing compound (ORC) to the rernediation of ground water contaminated with benzone and toluene was conducted in the Borden Aquifer in Ontario. Canada. Benzene and toluene were injected as organic substrates to represent BTEX compounds, bromide was used as a tracer, and nitrate was added to avoid nitrate-limited conditions.
The fate of the solutes was monitored along four lines of monitoring points and wells. Two lines studied the behavior of the solutes upgradient and downgradient of two large-diameter well screens filled with briquets containing ORC and briquets without ORC. One line was used to study the solute behavior upgradient and downgradient of columns of ORC powder placed directly in the saturated zone. The remaining line was a control.
The results indicate that ORC in both briquet and powder form can release significant amounts of oxygen to conlaminated ground water passing by it. In the formulation used in this work, oxygen release persisted for at least 10 weeks. Furthemiore, the study indicates that the enhancement of the available dissolved oxygen content of at least 4 mg/L each of the ground water by ORC can support biodegradation of benzene and toluene dissolved in ground water. Such concentrations are typical of those encountered at sites contaminated with petroleum hydrocarbons; therefore, these results suggest that there is promise for ORC to enhance in situ biodegradation of BTKX contaminants at such sites using passive (nonpumping) systems to contact the contaminated ground water with the oxygen source. 相似文献
The fate of the solutes was monitored along four lines of monitoring points and wells. Two lines studied the behavior of the solutes upgradient and downgradient of two large-diameter well screens filled with briquets containing ORC and briquets without ORC. One line was used to study the solute behavior upgradient and downgradient of columns of ORC powder placed directly in the saturated zone. The remaining line was a control.
The results indicate that ORC in both briquet and powder form can release significant amounts of oxygen to conlaminated ground water passing by it. In the formulation used in this work, oxygen release persisted for at least 10 weeks. Furthemiore, the study indicates that the enhancement of the available dissolved oxygen content of at least 4 mg/L each of the ground water by ORC can support biodegradation of benzene and toluene dissolved in ground water. Such concentrations are typical of those encountered at sites contaminated with petroleum hydrocarbons; therefore, these results suggest that there is promise for ORC to enhance in situ biodegradation of BTKX contaminants at such sites using passive (nonpumping) systems to contact the contaminated ground water with the oxygen source. 相似文献
33.
The role of land use and environmental factors on microbial pollution of mountainous limestone aquifers 总被引:1,自引:0,他引:1
Limestone aquifers in Southern Italy are often affected by bacterial contamination produced by pasture and agriculture. The
main goals of this study were (1) to analyze the role of land use and environmental factors on microbial contamination and,
(2) to identify, at field scale, the most suitable indicator of fecal pollution, by comparing fecal coliforms and fecal enterococci.
Analyzing surface and spring water, it was noted that both fecal indicators showed a significant decrease during the period
characterized by freezing and/or freeze-thaw intervals. The data analysis shows that fecal coliforms are characterized by
a significant decrease in population (3 orders of magnitude, at least) during the freezing period, while fecal enterococci
are temporarily inhibited. A taxonomic classification of fecal enterococci detected in spring water samples was performed
by the API 20 Strep system and by sequencing of the ribosomal 16S DNA genes. The results showed that freezing conditions did
not cause any significant change on the set of enterococcal species. 相似文献
34.
The Plio-Pleistocene stratigraphic record of the Peri-Adriatic basin (eastern central Italy) is well exposed along the uplifted western margin of the basin and consists of a series of coarse-grained slope canyon fills encased in a thick succession of hemipelagic mudstones. This study deals with the detailed sedimentology, stratal architecture, and sequence-stratigraphic interpretation of two of these submarine canyon-fills (namely CMC1 and CMC2) exposed at Colle Montarone. These strata contain widespread evidence of gravity-driven sedimentation processes, with high- and low-density turbidity currents, slumps and cohesive debris flows being responsible for most of the sediment transport and deposition. Beds are organised into four recurrent lithofacies, each corresponding to a specific deep-water depositional element: (i) clast-supported conglomerates (channel complexes); (ii) thin-bedded sandstones and mudstones (levee-overbank); (iii) very thinly-bedded mudstones (tributary channels); (iv) pebbly mudstones and chaotically bedded mudstones (mass-transport complexes). 相似文献
35.
36.
An integrating spectrometer based on a two-stage polyphase digital filter bank (PDFB) algorithm is described. The first PDFB operates on a time multiplexed wideband signal, with a bandwidth up to 1 GHz. The second PDFB is performed in parallel over couples of overlapping channels from the first filterbank. The design automatically deletes the unused portions of the first filterbank channels, providing a seamless, uniform channelization of the input band. The design has been implemented and tested on the VLBI DBBC platform, using a single Xilinx XC5VLX220 FPGA. 相似文献