首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new method for determining lead (Pb) content was developed by dispersive liquid–liquid microextraction based on the solidification of floating organic droplets followed by flame atomic absorption spectrometry. Under optimum conditions, the calibration graph was linear within the Pb content range of 8.43–400 µg L?1 with a detection limit of 2.53 µg L?1. The relative standard deviation for 10 replicate measurements of 20 and 400 µg L?1 of Pb were 3.41 and 2.78%, respectively. The proposed method was assessed through the analysis of certified reference water and recovery experiments.  相似文献   

2.
3.
A rapid and sensitive method for the determination of trace levels cadmium in water samples by flame atomic absorption spectrometry was developed. It is based on the online sorption of Cd(II) ions on a microcolumn packed with HCl treated bamboo charcoal. In a pH range of 5.0–7.5, Cd(II) ions were effectively retained on the microcolumn, which exhibited fast kinetics, permitting the use of high sample flow rates up to at least 12.8 mL/min without the loss of retention efficiency. The retained Cd(II) ions were quantitatively eluted with HCl (2.0 mol/L) for an online determination. With a preconcentration time of 80 s at a sample loading flow rate of 8.6 mL/min, a sensitivity enhancement factor of 63 was obtained compared with the slope of the linear portion of the calibration curves before and after preconcentration. The calibration graph using the preconcentration system for cadmium was linear with a correlation coefficient of 0.9997, at levels from 1–40 ng/mL. The precision (RSD) for 11 replicate measurements were 3.2% for the determination of 5 ng/mL Cd(II) and 1.8% for 20 ng/mL Cd(II), respectively, and the detection limit (3s) was 0.36 ng/mL. The accuracy was assessed through the determination of a certified reference material, and also through recovery experiments.  相似文献   

4.
5.
6.
In this work, a new separation–preconcentration method was developed for the determination of trace amounts of Cu(II), Ni(II), and Fe(III) by flame atomic absorption spectrometry (FAAS). Analytes were complexed by using zincon (2‐[2‐[alpha(2‐hydroxy‐5‐sulfophenylazo) benzylidene] hydrazino] benzoic acid sodium salt). The analyte ions were quantitatively adsorbed on a Diaion HP‐20 resin at pH 5. The retained metal ions on the resin were eluted by acetone. The analytical parameters such as pH of the sample, eluent type and volume, sample volume, and flow rates of the solution and the eluent were investigated. The influences of concomitant ions on the recoveries of the analytes were also examined. The instrumental detection limits for the analytes after application of the presented solid‐phase extraction procedure were in the range of 0.72–1.41 µg/L. The validation of the presented procedure was checked by analyzing certified reference material of SRM1515 Apple Leaves. The procedure was performed by analyzing some spice samples.  相似文献   

7.
A cloud point extraction procedure is presented for the preconcentration and simultaneous determination of Ag+ and Pd2+ in various samples. After complexation with 2‐((2‐((1H‐benzo[d]imidazole‐2‐yl)methoxy)phenoxy)methyl)‐1H‐benzo[d]imidazol (BIMPI), which was used as a new chelating agent, analyte ions were quantitatively extracted to a phase rich in Triton X‐114 following centrifugation, and determination was carried out by flame atomic absorption spectrometry (FAAS). Under the optimum experimental conditions (i. e., pH = 7.0, 15.0·10–5 mol/L BIMPI and 0.036% (w/v) Triton X‐114), calibration graphs were linear in the range of 28.0–430.0 μg/L and 57.0–720.0 μg/L with detection limits of 10.0 and 25.0 μg/L for Ag+ and Pd2+, respectively. The enrichment factors were 35.0 and 28.0 for Ag+ and Pd2+, respectively. The method has been successfully applied to evaluate these metals in some real samples, including waste water, soil and hydrogenation catalyst samples.  相似文献   

8.
The present paper proposes the application of multiwalled carbon nanotubes (MWCNTs) as a solid adsorbent for selective separation/preconcentration of silver(I) in water samples prior to flame atomic absorption spectrometry. The procedure is based on the solid phase extraction of Ag(I)–2‐mercaptobenzothiazole chelate on MWCNTs. The elution step is carried out with 5 mL of 2 mol L?1 HNO3 in acetone solution at a flow rate of 1.0 mL min?1. The influences of the various analytical parameters including pH of the solution, eluent type, sample volume, flow rates of eluent, matrix ions were investigated for optimization of the presented procedure. Tests of addition/recovery for analyte ion in real samples were performed with satisfactory results. Preconcentration factor and limit of detection for Ag(I) were 160 and 0.21 µg L?1, respectively. The synthesized MWCNT exhibited excellent stability in eluent solution and its adsorption capacity was 5.4 mg of silver per gram of sorbent. The proposed method was successfully applied to trace silver determination in a variety of environmental water samples.  相似文献   

9.
In this study, headspace single drop microextraction (HS‐SDME) method in combination with electrothermal atomic absorption spectrometry (ETAAS) method was developed and validated for the speciation and determination of inorganic mercury (iHg) and methylmercury (MeHg). MeHg and iHg species were reduced to volatile methylmercury hydride (CH3HgH) and elemental mercury, respectively, in the presence of NaBH4 and trapped onto a drop of acceptor phase in the tip of a microsyringe. Thiourea and ammonium pyrrolydinedithiocarbamate (APDC) were tested as the acceptor phase. The experimental parameters of the method such as microextraction time, temperature, NaBH4 concentration, acceptor phase concentration, and pH of the medium were investigated to obtain distinctive conditions for mercury species. Possible interference effects have also been investigated. In order to validation of the method, analytical figures of merits such as accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), and linear working range have been evaluated. Accuracy of the method has been verified by analyzing certified reference materials (BCR 453 Tuna fish) and spiked samples. The proposed method was applied for the speciation and determination of mercury species in water and fish samples. Mercury species (MeHg and iHg) have been determined in the real samples with a relative error less than 10%.  相似文献   

10.
A new separation and preconcentration technique based on coprecipitation of Cu(II) and Ni(II) ions by the aid of Mo(VI)/di‐tert‐butyl{methylenebis[5‐(chlorobenzyl)‐4H‐1,2,4‐triazol‐3,4‐diyl]}biscarbamate (BUMECTAC) precipitate has been established. The Mo(VI)/BUMECTAC precipitate was dissolved by concentrated HNO3 and the solution was completed to 5.0 mL with distilled/deionized water. The levels of the analyte ions were determined by flame atomic absorption spectrometer. The effects of experimental conditions like HNO3 concentration, amount of BUMECTAC and Mo(VI), sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of analyte ions. The preconcentration factors were found to be 40 for Cu(II) and 100 for Ni(II) ions. The detection limits for Cu(II) and Ni(II) ions based on 3σ (N:10) were 0.43 and 0.70 µg L?1, respectively. The relative standard deviations were found to be lower than 4.0% for both analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of two certified reference materials (Environment Canada TM‐25.3 and CRM‐SA‐C Sandy Soil C). The procedure was successfully applied to sea water and stream water as liquid samples and baby food as solid sample in order to determine the levels of Cu(II) and Ni(II) ions.  相似文献   

11.
The ultrasound‐assisted emulsification–microextraction (USAEME) method was combined with graphite furnace atomic absorption spectrometry (GFAAS) for the determination of trace Pb using dithizone (H2DZ) as chelating reagent. Some effective parameters influenced the detection and microextraction, such as ashing temperature and atomization temperature, pH, extraction solvent, sample volume, extraction time, and extraction temperature were selected and optimized. After extraction, the calibration curves for Pb was in the concentration range of 0.1–10 ng mL?1, and the linear equation was y = 0.097 x + 0.023 (R = 0.99). Under the optimized conditions, the detection limit of the method was 20 pg mL?1 with an enrichment factor of 70 and the relative standards deviation (RSD) for seven determinations of 1 ng mL?1 Pb was 11%. The proposed method was successfully applied to determine trace Pb in Yueya Lake water, pond water, and spiked samples. Furthermore, a certified reference material of Environment Water (GBW08607) was analyzed and the determined value was in good agreement with the certified value, which showed the accuracy, recovery, and applicability of the reported method.  相似文献   

12.
An on‐line solid phase extraction method for the preconcentration and determination of Cu(II) by flame atomic absorption spectrometry has been described. The procedure is based on the retention of Cu(II) ions at pH 6.0 on a minicolumn packed with Amberlite XAD‐1180 resin impregnated with chrome azurol S. After preconcentration, Cu(II) ions adsorbed on the impregnated resin were eluted by 1 mol L?1 HNO3 solution. Several parameters, such as pH, type of eluent, flow rates of sample and eluent solutions, amount of resin were evaluated. At optimized conditions, for 3.5 min of preconcentration time, the system achieved a detection limit of 1.0 µg L?1, and a relative standard deviation of 1.2% at 0.2 µg mL?1 copper. An enrichment factor of 56‐fold was obtained with respect to the copper determination. The proposed method was successfully validated by the analysis of standard reference material (TMDA 54.4 lake water) and recovery studies. The method was applied to the preconcentration of Cu(II) in natural water samples.  相似文献   

13.
A novel, simple, fast, and efficient ionic liquid‐based dispersive liquid–liquid extraction (IL‐DLLE) has been applied to extract and remove Congo Red (CR; a carcinogenic textile dye) from aqueous solutions. In this methodology a binary solution, containing the extraction solvent (1‐hexyl‐3‐methylimmidazolium bis(trifluormethylsulfonyl) imid) and a suitable disperser solvent, was rapidly injected into the water sample containing CR dye. Therewith, a cloudy solution was formed, and most of the dye molecules were extracted into fine IL droplets and removed from aqueous phase. The effects of pH, type, and amount of IL, initial concentration of the dye, type and volume of the dispersant, and concentrations of salt on the extraction of the dye were studied. Experimental surveys were also accomplished for recovery of the IL by applying a reverse dispersive liquid–liquid extraction using acidic stripping solutions.  相似文献   

14.
15.
Dispersive liquid–liquid microextraction based on solidification of floating organic droplet (DLLME‐SFO) technique was successfully applied for simultaneous assay of eight polychlorinated biphenyls, two organochlorine, and four pyrethroid pesticides multi‐residue in aqueous samples by using GC‐electron capture detection. The effects of various parameters such as kind of extractant and dispersant and volume of them, extraction time, effect of salt addition, and pH were optimized. As a result, 5.0 µL 1‐dodecanol was chosen as extraction solvent, 600 µL methanol were used as dispersive solvent without salt addition, pH was adjusted to 7. Under the optimized conditions, the limits of detection (LOD) were ranged from 1.4 to 8.3 ng L?1. Satisfactory linear range was observed from 5.0 to 2000 ng L?1 with correlation coefficient better than 0.9909. Good precisions were also acquired with RSD better than 13.6% for all target analytes. The enrichment factors of the method were ranged from 786 to 1427. The method can be successfully applied to simultaneous separation and determination of three class residues in real water samples and good recoveries were obtained ranging from 76 to 130, 73 to 129, and 78 to 130% for tap water, lake water, and industrial waste water, respectively.  相似文献   

16.
A multi‐element ion‐pair extraction method was described for the preconcentration of Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Mn(II), Ni(II), Pb(II), and Zn(II) ions in environmental samples prior to their determinations by flame atomic absorption spectrometry (FAAS). As an ion‐pair ligand 2‐(4‐methoxybenzoyl)‐N′‐benzylidene‐3‐(4‐methoxyphenyl)‐3‐oxo‐N‐phenyl‐propono hydrazide (MBMP) was used. Some analytical parameters such as pH of sample solution, amount of MBMP, shaking time, sample volume, and type of counter ion were investigated to establish optimum experimental conditions. No interferences due to major components and some metal ions of the samples were observed. The detection limits of the proposed method were found in the range of 0.33–0.9 µg L?1 for the analyte ions. Recoveries were found to be higher than 95% and the relative standard deviation (RSD) was less than 4%. The accuracy of the procedure was estimated by analyzing the two certified reference materials, LGC6019 river water and RTC‐CRM044 soil. The developed method was applied to several matrices such as water, hair, and food samples.  相似文献   

17.
18.
19.
This work describes the modification of silica gel with dimethylglyoxime, in order to prepare an effective sorbent for the preconcentration and determination of copper. The sorption capacity of dimethylglyoxime‐modified silica‐gel (DMGMS) was 71.37 mg g–1 and the optimum pH for the quantitative recovery of copper was found to be 5.0. The optimum flow rate, sorbent amount, and sample volume were 1 mL min–1, 300 mg, and 50 mL, respectively. 10 mL of 0.1 mol L–1 HCl was the most suitable eluent. The detection limit of copper was 6.0 ng mL–1. The recommended method, for the determination of copper, is simple and reliable, without any notable matrix effect and can be successfully applied to environmental water samples. Copper recovery in the range from 99–100% was obtained from seawater and thermal spring water using this method. The method was applied to standard reference materials, NIST‐1515 (apple leaves) and NIST‐1643e (simulated fresh water), for the determination of copper and the results were in good agreement with certified values.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号