首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
本文主要研究如何通过合理设计来提高高层钢结构的整体抗震能力。首先,给出了高层钢结构的非线性计算模型;其次,建立了高层钢结构在强地震动作用下的倒塌失效模式的极限状态判别准则;然后,通过模态pushover分析,研究了高层钢结构在水平地震作用下的损伤规律;最后,重点研究了高层钢结构的整体抗震能力的提高方法,提出了均匀损伤的设计方法,该方法通过消除结构的薄弱层,来达到提高高层钢结构的整体抗震能力的目的。通过对两栋20层的高层钢框架结构进行极限时程分析和极限pushover分析,验证了文中提出的均匀损伤的设计方法的可行性。本文的工作可为高层钢结构的抗地震倒塌设计提供参考依据。  相似文献   

2.
为进一步研究用等位移理论估计高层建筑结构非弹性地震反应,选用五个钢筋混凝土高层结构实例,输入二十条不同场地条件的地震波,采用结构弹性和非弹性地震时程反应分析方法,研究了结构弹性和非弹性最大顶点位移以及最大层间位移角之间的关系。提出可以直接用弹性最大顶点位移估计非弹性最大顶点位移。对于非弹性层间位移角反应,在中、弱非线陛阶段宜可直接用弹性反应结果估计,而在强非线性阶段则需进行一定修正。  相似文献   

3.
The outrigger system is an effective means of controlling the seismic response of core‐tube type tall buildings by mobilizing the axial stiffness of the perimeter columns. This study investigates the damped‐outrigger, incorporating the buckling‐restrained brace (BRB) as energy dissipation device (BRB‐outrigger system). The building's seismic responses are expected to be effectively reduced because of the high BRB elastic stiffness during minor earthquakes and through the stable energy dissipation mechanism of the BRB during large earthquakes. The seismic behavior of the BRB‐outrigger system was investigated by performing a spectral analysis considering the equivalent damping to incorporate the effects of BRB inelastic deformation. Nonlinear response history analyses were performed to verify the spectral analysis results. The analytical models with building heights of 64, 128, and 256 m were utilized to investigate the optimal outrigger elevation and the relationships between the outrigger truss flexural stiffness, BRB axial stiffness, and perimeter column axial stiffness to achieve the minimum roof drift and acceleration responses. The method of determining the BRB yield deformation and its effect on overall seismic performance were also investigated. The study concludes with a design recommendation for the single BRB‐outrigger system.  相似文献   

4.
In this paper, an innovative seismic lateral force resisting system for tall buildings is introduced. In this system, a novel supplemental part, ribbed bracing system (RBSyst), is attached to Braced Tube System, creating a modified BTS. RBSyst is a supplemental part which is attached to the conventional bracing members to eliminate buckling problem. The behavior of RBSyst under tensile force is similar to that of the conventional braces. However, in compression, it prevents the braces from buckling by length reduction. In order to evaluate the efficiency of this new BTS system by performance-based assessment, two typical 40-story tall buildings with different story modules equipped with this proposed bracing system are modeled numerically. Then, the seismic behavior of these 3-dimensional models are evaluated by nonlinear time history analysis under maximum considered earthquakes and service-level earthquakes. The results of the analysis demonstrate that the performance of the tall buildings equipped with this new BTS system is within the acceptable limits under both service-level and maximum considered earthquake ground motions. Additionally, it is shown that RBSyst part can effectively enhance the seismic behavior of BTS systems.  相似文献   

5.
Sustainability and resilience are issues that are recognized worldwide, and increased attention should be placed on strategies to design and maintain infrastructure systems that are hazard resilient, damage tolerant, and sustainable. In this paper, a methodology to evaluate the seismic sustainability and resilience of both conventional and base‐isolated steel buildings is presented. Furthermore, the proposed approach is used to explore the difference between the performance associated with these buildings by considering the three pillars of sustainability: economic, social, and environmental. Sustainability and resilience are both considered to cover a comprehensive performance‐based assessment content. The uncertainties associated with performance and consequence evaluation of structural and non‐structural components are incorporated within the assessment process. The proposed performance‐based assessment approach is illustrated on conventional and base‐isolated steel buildings under given seismic scenarios. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
The concept of the hybrid passive control system is studied analytically by investigating the seismic response of steel frame structures. Hybrid control systems consist of two different passive elements combined into a single device or system. The hybrid systems investigated in this research consist of a rate‐dependent damping device paired with a rate‐independent energy dissipation element. The innovative configurations exploit individual element strengths and offset their weaknesses through multiphased behavior. A nine‐story, five‐bay steel moment‐frame was used for the analysis. Six different seismic resisting systems were analyzed and compared. The conventional systems included a special moment‐resisting frame (SMRF) and a dual SMRF–buckling‐restrained brace (BRB) system. The final four configurations are hybrid passive systems. The different hybrid configurations utilize a BRB and either a high‐damping rubber damper or viscous fluid damper. The analyses were run in the form of an incremental dynamic analysis. Several damage measures were calculated, including maximum roof drift, base shear, and total roof acceleration. The results demonstrate the capability of hybrid passive control systems to improve structural response compared with conventional lateral systems and to be effective for performance‐based seismic design. Each hybrid configuration improved some aspect of structural response with some providing benefits for multiple damage measures. The multiphased nature provides improved response for frequent and severe seismic events. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
目前我国房屋建筑抗震采用的以小震弹性计算为基础的设计方法,使工程师忽视了对建筑结构在强烈地震作用下破坏模式的充分考虑与设计,使得建筑结构的大震安全性有时难以得到保证。"破坏-安全"抗震理念,以房屋建筑最重要的抗震安全性能为目标,要求设计人员对结构的预期破坏模式有充分的把握和控制,使结构在强烈地震作用下能够形成明确的预期破坏模式并具备一定的耗能能力,从而以经济的代价保证结构其余部分在强烈地震作用下的安全。本文结合我国汶川地震灾后恢复重建与加固改造的实际情况,介绍了"破坏-安全"抗震理念及其设计概念,并介绍了国内外研究人员与工程师在实现"破坏-安全"抗震理念方面所提出的创新抗震结构体系及其研究成果。希望"破坏-安全"这一抗震理念及其相关技术能够在我国广大的经济欠发达地区的抗震设计实践中得到推广,以全面提高我国经济欠发达地区房屋建筑的抗震安全性。  相似文献   

8.
高层钢结构地震失效模式控制的失效路径修正法   总被引:1,自引:0,他引:1  
本文主要研究高层钢框架结构的地震失效模式及其控制方法。首先,给出了高层钢结构的地震失效模式的分析方法;其次,提出了根据结构的失效路径来加强构件对高层钢结构的地震失效模式进行控制的方法;然后,提出了结构整体抗震能力的分析方法以及分别相应于设计能力和屈服能力的能力储备分析方法;最后,通过对一座15层的钢框架结构进行典型地震动下的极限时程分析和极限pushover分析,得到高层钢框架结构的失效模式和整体抗震能力以及相应于最弱失效模式的能力储备,并验证了本文中地震失效模式控制方法的有效性。本文的研究表明,高层钢结构的地震失效模式控制可以采用结构失效路径修正(薄弱构件加强)来实现。  相似文献   

9.
Existing buildings can be at a greater seismic risk due to non-conformance to current design codes and may require structural retrofitting to improve building performance. The performance of buildings is measured in terms of immediate consequences due to direct damage, but the continuing impacts related to recovery are not considered in seismic retrofit assessment. This paper introduces a framework of retrofit selection based on the seismic resilience of deficient buildings retrofitted with the conventional mitigation approaches. The assembly-based methodology is considered for the seismic resilience assessment by compiling a nonlinear numerical model and a building performance model. The collapse fragility is developed from the capacity curve, and the resulting social, economic, and environmental consequences are determined. The seismic resilience of a building is assessed by developing a downtime assessment methodology incorporating sequence of repairs, impeding factors, and utility availability. Five functionality states are developed for the building functionality given investigated time interval, and a functionality curve for each retrofit is determined. It is concluded that seismic resilience can be used as a performance indicator to assess the continuing impacts of a hazard for the retrofit selection.  相似文献   

10.
11.
This paper presents the seismic behaviour of a concentrically braced frame system with self‐centring capability, in which a special type of bracing element termed reusable hysteretic damping brace (RHDB) is used. The RHDB is a passive energy dissipation device with its core energy‐dissipating component made of superelastic Nitinol wires. Compared with conventional bracing in steel structures, RHDB has a few prominent performance characteristics: damage free under frequent and design basis earthquakes in earthquake prone areas; minimal residual drifts due to the self‐centring capability of RHDB frame; and ability to survive several strong earthquakes without the need for repair or replacement. This paper also includes a brief discussion of the RHDB's mechanical configuration and analytical model for RHDB. The seismic performance study of RHDB frame was carried out through a non‐linear time history analysis of 3‐storey and 6‐storey RHDB frame buildings subjected to two suites of 20 earthquake ground motions. The analysis results were compared with buckling‐restrained brace (BRB) frames. This study shows that RHDB frame has a potential to outperform BRB frames by eliminating the residual drift problem. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

12.
Reinforced concrete (RC) shear walls have been extensively used as lateral load resisting structural members in tall buildings. However, in the past, strong earthquake events RC structural walls in some buildings suffered severe damage, which concentrated at the bottom and was very difficult to be repaired. The installation of the replaceable corner components (RCCs) at the bottom of the structural wall is a new method to form an earthquake resilient structural wall whose function can be quickly restored by replacing the RCCs after the strong earthquake because of the damage concentrating on RCCs. In this study, a new kind of replaceable energy‐dissipation component installed at the bottom corner of RC structural walls was proposed. To study the seismic performance of the new structural wall with RCCs, the cyclic loading tests on three new structural wall specimens and one conventional RC structural wall specimen were conducted. One of the new structural wall specimens experienced replacement and reloading process to verify the feasibility of replacement. The results show that the structural behavior of all specimens was flexure dominating. The damage in the new shear specimens mainly concentrated on RCCs. The replacement of RCCs can be implemented conveniently after the residual deformation occurred in the structure. Compared with the conventional structural wall specimen, the seismic performance of new structural wall specimens was improved significantly. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

13.
As a result of rapid economic growth and urbanization in the past two decades,many tall buildings have been constructed in China Mainland,offering researchers and practitioners an excellent opportunity for research and practice in the field of structural engineering. This paper reviews progress by researchers throughout China Mainland on the seismic research of tall buildings,focusing on three major topics that impact the seismic performance of tall buildings. These are:(1) new types of steel-concrete composite structural members such as steel-concrete composite shear walls and columns,(2) earthquake resilient shear wall structures such as shear walls with replaceable structural components,self-centering shear walls and rocking walls,and(3) performance-based seismic design,including seismic performance index,performance level and design method. The paper concludes by presenting future research needs and directions in this field.  相似文献   

14.
The modal pushover analysis (MPA) procedure, presently restricted to one horizontal component of ground motion, is extended to three‐dimensional analysis of buildings—symmetric or unsymmetric in plan—subjected to two horizontal components of ground motion, simultaneously. Also presented is a variant of this method, called the practical modal pushover analysis (PMPA) procedure, which estimates seismic demands directly from the earthquake response (or design) spectrum. Its accuracy in estimating seismic demands for very tall buildings is evaluated, demonstrating that for nonlinear systems this procedure is almost as accurate as the response spectrum analysis procedure is for linear systems. Thus, for practical applications, the PMPA procedure offers an attractive alternative whereby seismic demands can be estimated directly from the (elastic) design spectrum, thus avoiding the complications of selecting and scaling ground motions for nonlinear response history analysis. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
Most current seismic design includes the nonlinear response of a structure through a response reduction factor(R). This allows the designer to use a linear elastic force-based approach while accounting for nonlinear behavior and deformation limits. In fact, the response reduction factor is used in modern seismic codes to scale down the elastic response of a structure. This study focuses on estimating the actual ‘R' value for engineered design/construction of reinforced concrete(RC) buildings in Kathmandu valley. The ductility and overstrength of representative RC buildings in Kathmandu are investigated. Nonlinear pushover analysis was performed on structural models in order to evaluate the seismic performance of buildings. Twelve representative engineered irregular buildings with a variety of characteristics located in the Kathmandu valley were selected and studied. Furthermore, the effects of overstrength on the ductility factor, beam column capacity ratio on the building ductility, and load path on the response reduction factor, are examined. Finally, the results are further analyzed and compared with different structural parameters of the buildings.  相似文献   

16.
新版抗震设防烈度区划图实施以来,大量单跨框架结构校舍因抗侧力体系不合理以及抗震承载力不足急需加固改造。针对单跨框架结构不满足刚度及承载力要求的现状,提出并阐述了BRB减震与橡胶隔震联合加固技术原理,并对昆明某实际单跨框架结构进行了动力弹性和弹塑性有限元分析,结果表明:在多遇地震下,防屈曲支撑(BRB)未屈服,结构整体处于弹性;在设防地震作用下,部分BRB屈服耗能,结构层间位移角最大值为1/582,结构主体处于弹性阶段;在罕遇地震作用下,所有BRB屈服耗能,且其滞回曲线饱满,结构弹塑性层间位移角最大值为1/148,大部分梁端部产生塑性铰,少数柱产生塑性铰,且梁较柱先出铰,表现出良好的抗震性能。研究为单跨框架结构的加固提供一条有效的新途径。  相似文献   

17.
传统高层建筑地震损伤模型不能反映构件极限滞回耗能随累积幅值的改变情况,无法有效确定组合参数,离散性较大。为此,设计一种远场长周期地震下高层建筑的地震损伤模型。针对不同层次高层建筑结构,依据广义力-广义变形曲线,构建变形损伤模型。结合累积能量比、远场长周期地震瞬时输入能比构建能量损伤模型。从变形与能量两方面综合评价损伤,依据钢筋混凝土结构构建最大反应变形与耗损能量的线性组合地震损伤模型,并对其进行改进。实验选用ILA003、ILA048和TCU115三种长周期地震波,计算不同构件和高层建筑结构整体损伤结果,验证所提模型的可靠性。将所提模型应用于实际高层建筑中,发现其实用性强。  相似文献   

18.
Guo  Wei  Wu  Jun  Hu  Yao  Li  Yunsong  Yang  T. Y. 《地震工程与工程振动(英文版)》2019,18(2):433-446
Adding dampers is a commonly adopted seismic risk mitigation strategy for modern buildings, and the corresponding design procedure of dampers has been well established by the Chinese Building Code. Even though all types of dampers are designed by the same procedure, actual seismic performance of the building may differ from one to the others. In this study, a nine-story benchmark steel building is established, and three different and typical types of dampers are designed according to the Chinese Building Code to realize structural vibration control under strong earthquake excitation. The seismic response of the prototype building equipped with a viscoelastic damper, viscous damper and buckling-restrained brace(BRB) subjected to 10 earthquake records are calculated, and Incremental Dynamic Analysis(IDA) is performed to describe progressive damage of the structure under increasing earthquake intensity. In the perspective of fragility, it shows that the viscoelastic damper has the highest collapse margin ratio(CMR), and the viscous damper provides the best drift control. Both the BRB and viscoelastic dampers can effectively reduce the floor acceleration responses in the mid-rise building.  相似文献   

19.
Seismic safety of low ductility structures used in Spain   总被引:1,自引:0,他引:1  
The most important aspects of the design, seismic damage evaluation and safety assessment of structures with low ductility like waffle slabs buildings or flat beams framed buildings are examined in this work. These reinforced concrete structural typologies are the most used in Spain for new buildings but many seismic codes do not recommend them in seismic areas. Their expected seismic performance and safety are evaluated herein by means of incremental non linear structural analysis (pushover analysis) and incremental dynamic analysis which provides capacity curves allowing evaluating their seismic behavior. The seismic hazard is described by means of the reduced 5% damped elastic response spectrum of the Spanish seismic design code. The most important results of the study are the fragility curves calculated for the mentioned building types, which allow obtaining the probability of different damage states of the structures as well as damage probability matrices. The results, which show high vulnerability of the studied low ductility building classes, are compared with those corresponding to ductile framed structures.  相似文献   

20.
This study describes the seismic performance of an existing five storey reinforced concrete building which represents the typical properties of low-rise non-ductile buildings in Turkey. The effectiveness of shear walls and the steel bracings in retrofitting the building was examined through nonlinear static and dynamic analyses. By using the nonlinear static analysis, retrofitted buildings seismic performances under lateral seismic load were compared with each other. Moreover, the performance points and response levels of the existing and retrofitting cases were determined by way of the capacity-spectrum method described in ATC-40 (1996). For the nonlinear dynamic analysis the records were selected torepresent wide ranges of duration and frequency content. Considering the change in the stiffness and the energy dissipation capacities, the performance of the existing and retrofitted buildings were evaluated in terms of story drifts and damage states. It was found that each earthquake record exhibited its own peculiarities, dictated by frequency content, duration, sequence of peaks and their amplitude. The seismic performance of retrofitted buildings resulted in lower displacements and higher energy dissipation capacity depending mainly on the properties of the ground motions and the retrofitting strategies. Moreover, severe structural damage (irreparable or collapse) was observed for the existing building. However, buildings with retrofit alternatives exhibited lower damage levels changing from no damage to irreparable damage states.  相似文献   