首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
It is not common to purposely subject the web of wide‐flange or I‐sections to out‐of‐plane bending. However, yielding the web under this loading condition can be a stable source of energy dissipation as the transition at the corner from the web to the flanges is smooth and weld‐free; this prevents stress concentrations causing premature failure and eliminates uncertainties and imperfections associated with welding. Further, short segments of wide‐flange or I‐sections constitute a simple and inexpensive energy dissipating device as minimum manufacturing is required and leftovers not useful for other structural purposes can be re‐utilized. This paper proposes a new type of seismic damper in the form of braces based on yielding the web of short length segments of wide‐flange or I‐shaped steel sections under out‐of‐plane bending. The hysteretic behavior and ultimate energy dissipation capacity is investigated via component tests under cyclic loads. The experimental results indicate that the damping device has stable restoring force characteristics and a high energy dissipation capacity. Based on these results, a simple hysteretic model for predicting the load–displacement curve of the seismic damper is proposed, along with a procedure for predicting its ultimate energy dissipation capacity and anticipating its failure under arbitrarily applied cyclic loads. The procedure considers the influence of the loading path on the ultimate energy dissipation capacity. Finally, shaking table tests on half‐scale structures are conducted to further verify the feasibility and effectiveness of the new damper, and to assess the accuracy of the hysteretic model and the procedure for predicting its failure. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
This paper explores the influence of linear hysteretic damping on the performance of passive tuned-inerter devices. An inerter is a device that produces a force proportional to the relative acceleration across its two terminals; devices incorporating inerters have received widespread attention in the earthquake engineering community, because they offer the ability to improve the seismic response of structures. However, the majority of this research has assumed that the damping components within the tuned-inerter device exhibit viscous, rather than hysteretic, damping. This restriction imposes an essential question on how the hysteretic damping model will change the performance of the device compared with the viscous damping model. It is shown that the response of viscous and hysteretic inerter systems have significant differences in displacement amplitude due to the frequency dependency of the damping. Therefore, a new formulation for obtaining the optimum loss factor of the hysteretic damping in the inerter system is proposed. Next, the challenges associated with accurately predicting the time-response of a hysteretically damped system are discussed. A numerical time-integration method is extended to address these challenges, using a new formulation that has the benefit of being broadly applicable to multidegree-of-freedom hysteretic linear systems and nonstationary random signals. The results show that the earthquake responses from the hysteretic damping model can differ significantly from the ones obtained via the viscous model.  相似文献   

3.
A new type of bracing system composed of friction energy dissipation devices for energy dissipation, pre‐pressed combination disc springs for self‐centering and tube members as guiding elements is developed and experimentally studied in this paper. The mechanics of this system are explained, the equations governing its hysteretic responses are outlined and large‐scale validation tests of two braces with different types of disc springs are conducted under the condition of low cyclic reversed loading. The experimental results demonstrate that the proposed bracing system exhibits a stable and repeatable flag‐shaped hysteretic response with an excellent self‐centering capability and effective energy dissipation throughout the loading protocol. Furthermore, the maximum bearing force and stiffness are predicted well by the equations governing its mechanical behavior. Fatigue and destructive test results demonstrate that the proposed bracing system can maintain stable energy dissipation and self‐centering capabilities under large deformation cyclic loading even when the tube members exceed the elastic limit and that a larger bearing capacity is achieved by the system that has disc springs without a bearing surface. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
低屈服点钢剪切板阻尼器滞回性能试验研究   总被引:4,自引:0,他引:4  
为改善传统滞变型阻尼器在小振动变形时不明显的耗能效果,利用国产低屈服点钢设计了5个剪切板阻尼器(LYPSSP),并对其进行低周往复循环荷载试验,重点考察阻尼器核心板连接方式、高厚比、十字加劲肋对其滞回性能的影响。研究结果表明:核心板与翼缘板通过熔透焊缝连接与螺栓连接相比,构造简单、可靠度高且易加工;由国产低屈服点钢制作的剪切板阻尼器滞回曲线饱满,耗能性能好,在同一位移级别下循环的滞回曲线基本上重合,稳定性好,并且在整个循环加载过程中,强化现象非常明显,破坏之前也没有出现强度和刚度的突然改变;以P/Py为设计目标时,核心板高厚比越小、面外屈曲越小,滞回曲线就越饱满,耗能性能就越好;根据等效粘滞阻尼器系数和平均耗能指数,能够对阻尼器的耗能性能很好地做出评价。  相似文献   

5.
A number of experiments indicate that the internal damping corresponding to the energy dissipation of many materials is essentially frequency independent. Accordingly, an analysis model that can express such characteristics (called a hysteretic damping model) in the time domain is needed. Although a great number of investigations into this subject have been carried out, there are a few practical methods. In this paper, a simple hysteretic damping model which satisfies the causality condition is presented using an extension of the complex stiffness transfer method that the author has proposed. Compared with the energy proportional damping model and the Biot model, the applicability and the efficiency of this model to time history response analyses were confirmed well by example problems. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

6.
7.
The investigation of structural single rocking walls (SRWs) continues to gain interest as they produce self-centering lateral load responses with reduced structural damage. The simple rocking model with modifications has been shown to capture these responses accurately if the SRW and its underlying base are infinitely rigid. This paper advances previous rocking models by accounting for (1) the inelastic actions at or near the base of the SRW and (2) the flexural responses within the wall. Included in the proposed advancements are hysteretic and inherent viscous damping associated with these two deformation components so that the total dynamic responses of SRWs can be captured with good accuracy. A system of nonlinear equations of motion is developed, in which the rocking base is discretized into fibers using a zero-length element to locate the associated compressive deformations and damage. The flexural deformations of the rocking body are captured using an elastic term, while the impact events are modeled using impulse-momentum equations. Comparisons with experiments of structural precast concrete and masonry SRWs show that the proposed approach accurately estimates the dynamic responses of different SRWs with and without unbonded posttensioning, for various dynamic excitations and degrees of hysteretic action. Using the proposed approach, a numerical investigation employs different configurations of structural SRWs to quantify the various sources of energy loss, including hysteretic action and impact damping, during various horizontal ground motions.  相似文献   

8.
Damping formulation for nonlinear 1D site response analyses   总被引:2,自引:0,他引:2  
Measurements and observations of ground shaking during large earthquakes have demonstrated the predominant role of site effects in the response of infrastructure during a seismic event. Despite significant efforts to model the hysteretic response and nonlinearity of soils due to medium and large ground motions, the most widely accepted nonlinear site response methods are not able to represent simultaneously the changes of stiffness and energy dissipation (damping) observed in both laboratory tests and during earthquake events. This paper presents two new soil damping formulations implemented in nonlinear one-dimensional site response analysis for small and large strains. The first formulation introduces an approach to construct a frequency-independent viscous damping matrix which reduces the over-damping at high frequencies, and therefore, the filtering at those frequencies. The second formulation introduces a reduction factor that modifies the extended Masing loading/unloading strain–stress relationship to match measured modulus reduction and damping curves simultaneously over a wide range of shear strains. A set of examples are introduced to illustrate the effect of using the two proposed formulations, separately and simultaneously, in nonlinear site response analyses.  相似文献   

9.
The insertion of fluid viscous dampers in building structures is an innovative technology that can improve significantly the seismic response. These devices could be very useful also in the retrofit of existing buildings. The effect of this typology of damping system is usually identified with an equivalent supplemental damping ratio, which depends on the maximum displacement of the structure, so that iterative procedures are required. In this paper, a simplified direct assessment method for nonlinear structures equipped with nonlinear fluid viscous dampers is proposed. The method proposed in this study is composed by two steps. The first one yields the direct estimate of the supplemental damping ratio provided by nonlinear viscous dampers in presence of a linear elastic structural response. The second step extends the procedure to structures with nonlinear behavior. Both graphical and analytical approaches have been developed. The proposed method has then been verified through several applications and comparisons with nonlinear dynamic analyses. Moreover, an investigation has been performed with regard to the influence of the relations that define the damping reduction factor and the hysteretic damping. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
A new method of stiffness‐damping simultaneous identification of building structures is proposed using limited earthquake records. It is shown that when horizontal accelerations are recorded at the floors just above and below a specific storey in a shear building model, the storey stiffness and the damping ratio can be identified uniquely. The viscous damping coefficient and the linear hysteretic damping ratio can also be identified simultaneously in a numerical model structure. The accuracy of the present identification method is investigated through the actual limited earthquake records in a base‐isolated building. It is further shown that an advanced identification technique for mechanical properties of a Maxwell‐type model can be developed by combining the present method with a perturbation technique. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

11.
消能减震结构设计参数研究与试验验证   总被引:10,自引:1,他引:9  
本文就消能减震结构设计参数,即消能部件的支撑刚度、层间最大阻尼力与结构层间屈服力比值等恢复力模型参数的选取进行了讨论。通过对消能装置的耗能特性理论分析,导出了消能装置产生的层间等效阻尼比与这些参数的关系曲线,建议了这些参数的合理取值范围。同时通过对两个消能减震试验结果的分析,验证了本文建议的参数取值的合理性。  相似文献   

12.
This paper investigates the effects of supplemental viscous damping on the seismic response of one‐storey, asymmetric‐plan systems responding in the inelastic range of behaviour. It was found that addition of the supplemental damping reduces not only deformation demand but also ductility and hysteretic energy dissipation demands on lateral load resisting elements during earthquake loading. However, the level of reduction strongly depends on the plan‐wise distribution of supplemental damping. Nearly optimal reduction in demands on the outermost flexible‐side element, an element generally considered to be the most critical element, was realized when damping was distributed unevenly in the system plan such that the damping eccentricity was equal in magnitude but opposite in algebraic sign to the structural eccentricity of the system. These results are similar to those noted previously for linear elastic systems, indicating that supplemental damping is also effective for systems expected to respond in the inelastic range. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

13.
This paper presents qualitative investigations on the energy behaviour of structures into which hysteretic dampers are incorporated. Emphasis was given to the ratio of the structural stiffness after the yielding of hysteretic dampers to the initial elastic stiffness, with a premise that this ratio, termed α in this study, tends to be large for structures with hysteretic dampers. Structures concerned were represented by discrete spring–mass systems having bilinear restoring force behaviour, in which the second stiffness relative to the initial stiffness is α. It was found that with the increase of α the total input energy tends to increase, but the increase is confined to a narrow range of natural periods. Both the total input energy and hysteretic energy were found to become less sensitive to the yield strength with the increase of α. A simple formula was also proposed to estimate the maximum deformation given the knowledge of the hysteretic energy. Analysis of MDOF systems revealed that, even when α is large, the total input energy and hysteretic energy for MDOF systems are approximately the same as those of the equivalent SDOF system, and the hysteretic energy can be distributed uniformly over the stories if α is large.  相似文献   

14.
考虑到多维地震输入对网架结构的不利影响,基于形状记忆合金超弹性,研制出一种兼具自复位、高耗能及放大功能于一体的形状记忆合金复合黏滞阻尼器(Hybrid Shape Memory Alloy Viscous Dampers,简称HSMAVD),并通过试验研究该阻尼器在循环荷载作用下的力学性能;然后以平面四角锥网架模型为基础,将该阻尼器替换部分网架结构杆件,并分析该阻尼器减震控制效果。结果表明形状记忆合金与黏滞阻尼器复合后具有良好的协同工作能力,可有效发挥形状记忆合金的超弹性和黏滞阻尼器的速度相关特性,使其具有稳定的滞回性能和良好的耗能能力;采用阻尼杆件替换原杆件的方法既能对结构进行有效的减震控制,又不改变原有的结构形式,是一种优越的减震控制方法,并为HSMAVD被动控制系统在结构抗震中的实际应用提供新思路。  相似文献   

15.
内藏X形软钢板铅复合耗能器的力学性能及减震分析   总被引:1,自引:0,他引:1  
在内藏X形软钢板铅复合耗能器和软钢耗能器低周反复荷载试验研究基础上,进行了理论分析,理论计算滞回曲线与实测滞回曲线吻合较好。建议了恢复力模型。将内藏X形软钢板铅复合耗能器应用到了悬挂减震结构中,进行了地震反应时程计算分析,计算结果表明,装有内藏X形软钢板铅复合耗能器的结构具有良好的减震性能。  相似文献   

16.
The energy dissipation characteristics of reinforced concrete members that exhibit both strength and stiffness deterioration under imposed displacement reversals were investigated. To do this, 24 symmetrically reinforced concrete rectangular specimens were tested under stable variable and random variable amplitude inelastic displacement cycles. Stable variable amplitude tests were employed to determine the low‐cycle fatigue behavior of specimens where the loading sequence was the major variable. A 2‐parameter fatigue model was developed in order to express the variation of the dissipated energy in displacement cycles with the cumulative hysteretic energy. This model was then used to predict the energy dissipation of test specimens subjected to random variable amplitude displacement cycles simulating severe seismic excitations. It has been demonstrated that the remaining energy dissipation capacity for the next displacement cycle was dependent on the relative relationship between the maximal displacement cycle and the energy dissipated along the completed displacement path. The plastic energy dissipation capacity of reinforced concrete members is both displacement path dependent and cumulative hysteretic energy dependent.  相似文献   

17.
Supplemental viscous damping devices are generally envisioned to be connected in parallel to the inelastic parent structure or hysteretic damping devices. This gives rise to higher base shear, and often greater ductility demand of the hysteretic system. The series connection of the viscous and hysteretic system (the inelastic structure or a damper) is an alternative approach. In this paper, comparisons between the series and parallel connections of the hysteretic system and viscous dampers are done through response spectra analyses of single degree of freedom structures. Ductility demand of the hysteretic system and the total base shear are chosen as the response quantities. For the series model, a semi‐implicit solution scheme for classical Maxwell model is modified to include the inelasticity of the time‐independent hysteretic spring. It is observed that the series connection of the 2 dampers gives lower base shear than does the parallel connection. For long‐period and low‐damping structures, the ductility demand of the hysteretic system in series connection is higher than that in parallel connection. Increasing the viscous damping in series connection reduces the ductility demand substantially, lower than that obtained in parallel connection. Practical methods for implementing the series and parallel connections, in line with roof isolation, are also suggested.  相似文献   

18.
腹板开孔耗能支撑有效地避免了传统中心支撑斜杆的失稳破坏,具有较强的耗能能力.为研究腹板开孔形状对支撑滞回性能的影响,对腹板开菱形孔、椭圆孔及长圆孔耗能支撑试件进行了低周往复加载试验,分析了试件在循环荷载作用下的破坏机理、滞回性能、承载能力、刚度退化及耗能能力.试验结果表明:耗能支撑试件滞回曲线饱满,耗能性能优越.耗能支...  相似文献   

19.
A new earthquake resistant structural system for multi‐storey frame structures, based on a dual function of its bracing components, is developed. This consists of a hysteretic damper device and a cross‐bracing mechanism with a kinetic closed circuit, working only in tension, so that cable members can be used for this purpose. Solutions are presented regarding the connections' design of three types of structural frame system, that are concerned throughout the study: braced moment free frame, braced moment resisting frame with moment free supports, and with moment resisting supports. The dynamic behaviour of the system is investigated on the basis of an SDOF model, and based on the response spectra method an approximate design approach of the controlled structures is shown. From the time history analysis of the structural systems for the El Centro earthquake the areas of appropriate stiffness relations of the frames to the hysteretic dampers and the cable braces are deduced, so that the energy dissipation of the system may be controlled by the damper‐cable bracing mechanism. Based on the results of these studies, a predesign approach is developed for the implementation of the control system in frame structures. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

20.
In this paper two causal models that approximate the nearly frequency‐independent cyclic behaviour of soils are analysed in detail. The study was motivated by the need to conduct time‐domain viscoelastic analysis on soil structures without adopting the ad hoc assumption of Rayleigh damping. First, the causal hysteretic model is introduced in which its imaginary part is frequency independent the same way that is the imaginary part of the popular non‐causal constant hysteretic model. The adoption of an imaginary part that is frequency independent even at the zero‐frequency limit, in conjunction with the condition that the proposed model should be causal, yields a real part that is frequency dependent and singular at zero frequency. The paper shows that the causal hysteretic model, although pathological at the static limit, is the mathematical connection between the non‐causal constant hysteretic model and the physically realizable Biot model. The mathematical structure of the two causal models is examined and it is shown that the causal hysteretic model is precisely the high‐frequency limit of the Biot model. Although both models have a closed‐form time‐domain representation, only the Biot model is suitable for a time‐domain viscoelastic analysis with commercially available computer software. The paper demonstrates that the simplest, causal and physically realizable linear hysteretic model that can approximate the cyclic behaviour of soil is the Biot model. The proposed study elucidates how the dynamic analysis of soil structures can be conducted rigorously in terms of the viscoelastic properties of the soil material and not with the ad hoc Rayleigh damping approach which occasionally has been criticized that tends to overdamp the higher vibration modes. The study concludes that under pulse‐type motions the Rayleigh damping approximation tends to overestimate displacements because of the inappropriate viscous type of dissipation that is imposed. Under longer motions that induce several cycles, the concept of equivalent viscous damping is more appropriate and the Rayleigh damping approximation results to a response that is comparable to the response computed with a rigorous time‐domain viscoelastic finite element analysis. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   