首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Turbulent exchange above a pine forest II. Organized structures   总被引:1,自引:0,他引:1  
Data from two 100-min runs on the turbulent atmospheric wind, temperature and humidity fields above a pine forest have been analysed using conditional sampling techniques. With the aid of the temperature time series, ramp events were identified and all fields were averaged in order to remove smaller scale turbulence and random low-frequency turbulence, and to map the organized structures revealed in this way. It is shown that the turbulent fluxes of momentum, heat and humidity, determined from these ramp-events, in fact constitute a large part of the total fluxes, about 90% during the actual events.On average, the duration of and the time between ramps were found to be about 35 s and 100 s, respectively. These periods were also found in the uw-, wT- and wq-cospectra, not only in the data analysed in this paper, but in the major part of all day-time data from this forest site (about 80 runs of 60 or 100 min). This indicates that the ramp events described arc a rather common phenomenon. The organized structures also have remarkable resemblance to near-wall structures observed in the laboratory.  相似文献   

2.
Diurnal and vertical ambient air measurements of the monoterpenes have been made in and above a Scots pine (Pinus sylvestris) forest of central Sweden, within the boreal northern coniferous biome. Sampling was done with Tenax TA, and analysis by GC and ion trap detection. Daytime mixing ratios were on the order of tenths of a ppbv from the forest floor to the top of the forest, and a factor of 2 or 3 lower above the forest. Mixing ratios at night were at the ppbv level, highest near the forest floor and the crown, and decreased with height above the forest. The highest total concentration observed was 8 ppbv inside the forest at 3 am (GMT). The average terpene composition was 3-carene 32%, -pinene 29%, limonene 18%, -pinene 10%, -phellandrene 7%, camphene 5%, and sabinene at less than 2%. The 3-carene/-pinene ratio varied with wind direction and speed, relative humidity, and wet/dry vegetation, but not with ozone or NO2 concentration, solar radiation, or temperature. Variations in the observed terpene composition at the sampling site are mainly caused by the influence of other vegetation in the vicinity of the site. It would seem that wet Scots pine emits more 3-carene relative to -pinene than does dry pine.  相似文献   

3.
4.
Measurements of gradients of wind, temperature and humidity and of the corresponding turbulent fluxes have been carried out over a sparse pine forest at Jädra»s in Sweden. In order to ascertain that correct gradient estimates were obtained, two independent measuring systems were employed: one system with sensors at 10 fixed levels on a 51 m tower and another with reversing sensors for temperature and humidity, covering the height interval 23 to 32 m. Turbulent fluxes were measured at three levels simultaneously. Data from three field campaigns: in June 1985, June 1987 and September 1987 have been analyzed. The momentum flux is found on the average to be virtually constant from tree top level, at 20 to 50 m. The average fluxes of sensible and latent heat are not so well behaved. The ratio of the non-dimensional gradients of wind and temperature to their corresponding values under ideal conditions (low vegetation) are both found to be small immediately above the canopy (about 0.3 for temperature and 0.4 for wind). With increasing height, the ratios increase, but the values vary substantially with wind direction. The ratios are not found to vary systematically with stability (unstable stratification only studied). The ratio of the non-dimensional humidity gradient to the corresponding non-dimensional potential temperature gradient (equivalent to k h /k w ) is found to be unity for (z – d)/L v less than about –0.1 and about 1.4 for near neutral stratification, but the scatter of the data is very large.  相似文献   

5.
During the summer of 1974, simultaneous heat flux measurements were made over a pine forest in three ways:
  1. Using the Bowen ratio - Energy Budget technique, with the Bowen ratio estimated from temperature and humidity profiles measured with two pairs of wet-and dry-bulb thermometers at six levels.
  2. Using the Bowen ratio - Energy Budget technique, with the Bowen ratio estimated from temperature and humidity measurements using pairs of wet-and dry-bulb thermometers mechanically interchanged every ten minutes.
  3. Using the Eddy Correlation - Energy Budget technique, with a direct measurement of the sensible heat flux made by a simple eddy correlation apparatus.
Methods (b) and (c) are shown to give similar results apart from a systematic difference of about 25% in the measured sensible heat flux. This corresponds to an underestimate of the sensible heat flux by the eddy correlation apparatus. Although sometimes consistent with the other two methods, on occasions method (a) gave results which were significantly different from both (b) and (c). When differences occurred, they tended to be systematic and persistent over individual days; but they could change magnitude and sign if the particular sensors used at each level in the profile were rearranged. The experimental program used to collect these and previous data involved the rearrangement of sensors on a regular (two day) time scale. It is shown that, when averaged over several such rearrangements, method (a) produces median values of surface resistance which are more in keeping with those produced by the other methods. This is taken to imply that data previously gathered in this way can be used to produce physically reasonable results providing they are averaged over several days. On the basis of the results presented, recommendations are made on future experimental work in forest micrometeorology.  相似文献   

6.
Summary ?The long-term variations of upward terrestrial (E) and downward atmospheric (A) long-wave radiation fluxes above a pine stand in the southern part of the upper Rhine valley plain are analysed based on monthly mean values from 27 years of monitoring. Equivalent blackbody temperatures of the canopy and the atmosphere are calculated and compared to air temperatures at nearby sites. Based on 324 monthly values each, correlations between A and E as well as A and global radiation G are analysed. Only the former are highly correlated. Monthly mean values of long-wave radiation A can be calculated from air temperature, water vapour pressure and cloud cover. The long-term yearly average of equivalent blackbody temperature of the canopy is 0.6 K lower than kinetic air temperature at nearby sites. Only small, insignificant increases of both blackbody temperatures and air temperature are found. Despite the strong forest growth, it is surprising that the ratio of canopy emission temperature to air temperature did not change significantly. Relationships between the changes of general atmospheric circulation and equivalent blackbody temperatures of the canopy point to a strong dependence on shifts of general atmospheric flow. Received February 24, 2000; revised April 18, 2002; accepted July 20, 2002  相似文献   

7.
Turbulence Measurements above a Pine Forest   总被引:1,自引:0,他引:1  
Eddy fluxes of momentum, sensible and latent heat, and turbulence spectra measured over the Thetford Forest during 10 days in the Spring of 1973 are described. The measured total heat flux (H + λE) for 122 20-min periods agreed closely on average with independent estimates from an energy balance method. There was evidence that the energy balance data gave small systematic overestimates of available energy during the hours before noon, compensated by slight underestimates for the remainder of the day. A comparison of measured wind speeds and friction velocities in neutral stability confirmed the validity of the aerodynamic method for estimating momentum fluxes at heights of a few roughness lengths above the canopy. In stable conditions the log-linear wind profile $U=(u_{?t}/k)({? ln}((z-d)/z_{0})+←pha(z-d-z_{0})/L)$ with α = 3.4 ± 0.4 provided a good fit to the data. Spectra in unstable conditions were generally more sharply peaked than those measured by other workers over smoother terrain: differences were less marked in the case of vertical velocity in stable conditions. Temperature spectra in these stable conditions showed high energy at relatively low wavenumbers, and wT cospectra showed a cospectral gap; both of these results were associated with an intermittent sawtooth structure in the temperature fluctuations.  相似文献   

8.
9.
Quartz crystal thermometers with ceramic tubes for the wet bulbs were used to measure vertical profiles of temperature and humidity above a pine forest. The effect of the supporting structures on the measurements and an objective method of calculating the Bowen ratio are described. The surface resistance was computed from the Bowen-ratio results. The diurnal variations in the average surface resistance of the forest for groups of dry days in Spring, Summer and Autumn are presented.  相似文献   

10.
Summary The spatial variability of turbulence above a forest has been examined. Two measurement towers were erected 800 m apart within a heterogeneous mixed forest located in the north east of the Netherlands. The measurements of u * /u were analysed and subsequently used to test a surface layer model. The model simulated the magnitude of the measurements reasonably well, but measured trends were not always reproduced by the model. The variable (du/dz)/u did not adapt as quickly to the new surface as u * /u. This is in agreement with Schmid (1994), and can be explained by a local decrease in mixing length. It is recommended to adapt the mixing length near a surface transition to improve the accuracy of surface layer models of heterogeneous landscapes. Received September 8, 1997 Revised April 15, 1998  相似文献   

11.
Six levels of simultaneously sampled ultrasonic data are used to analyse the turbulence structure within a mixed forest of 13 m height on a steep slope (35°) in an alpine valley. The data set is compared to other studies carried out over forests in more ideal, flat terrain. The analysis is carried out for 30-min mean data, joint probability distributions, length scales and spectral characteristics.Thermally induced upslope winds and cold air drainage lead to a wind speed maximum within the trunk space. Slope winds are superimposed on valley winds and the valley-wind component becomes stronger with increasing height. Slope and valley winds are thus interacting on different spatial and time scales leading to a quite complex pattern in momentum transport that differs significantly from surface-layer characteristics. Directional shear causes lateral momentum transports that are in the same order or even larger than the longitudinal ones. In the canopy, however, a sharp attenuation of turbulence is observed. Skewed distributions of velocity components indicate that intermittent turbulent transport plays an important role in the energy distribution.Even though large-scale pressure fields lead to characteristic features in the turbulent structure that are superimposed on the canopy flow, it is found that many statistical properties typical of both mixing layers and canopy flow are observed in the data set.  相似文献   

12.
Summary The surface energy exchange of 12m high Scots pine plantation at Hartheim, Germany, was measured with a variety of methods during a 11-day period of fine weather in mid-May 1992. Net radiation and rate of thermal storage were measured with conventional net radiometers, soil heat flux discs and temperature-based storage models. The turbulent fluxes discussed in this report were obtained with an interchanging Bowen ratio energy budget system (BREB, at 14 m), two one-propeller eddy correlation systems (OPEC systems 1 and 2 at 17m), a 1-dimensional sonic eddy correlation system (SEC system 3) at 15 m, all on one low tower, and a 3-dimensional sonic eddy correlation system (SEC system 22) at 22 m on the high tower that was about 46 m distant. All systems measured sensible and latent heat (H and LE) directly, except for OPEC systems 1 and 2 which estimated LE as a residual term in the surface energy balance. Closure of turbulent fluxes from the two SEC systems was around 80% for daytime and 30% for night, with closure of 1-dimensional SEC system 3 exceeding that of 3-dimensional SEC system 22. The night measurements of turbulent fluxes contained considerable uncertainty, especially with the BREB system where measured gradients often yielded erroneous fluxes due to problems inherent in the method (i.e., computational instability as Bowen's ratio approaches –1). Also, both eddy correlation system designs (OPEC and SEC) appeared to underestimate |H| during stable conditions at night. In addition, both sonic systems (1- and 3-dimensional) underestimated |LE| during stable conditions. The underestimate of |H| at night generated residual estimates of OPEC LE containing a phantom dew error that erroneously decreased daily LE totals by about 10 percent. These special night problems are circumvented here by comparing results for daytime periods only, rather than for full days. To summarize, turbulent fluxes on the low tower from OPEC system 2 and the adjacent SEC system 3 were in reasonable agreement, while the BREB system appeared to overestimate H and underestimate LE; H and LE measured by SEC system 22 on the high tower were lower than from OPEC and SEC3 on the low tower. The turbulent flux measurements tended to converge, but the data exhibit unexplained differences between days, between systems, and between locations.With 7 Figures  相似文献   

13.
Turbulence structure in a deciduous forest   总被引:5,自引:2,他引:5  
Three-dimensional wind velocity components were measured at two levels above and at six levels within a fully-leafed deciduous forest. Greatest shear occurs in the upper 20% of the canopy, where over 70% of the foliage is concentrated. The turbulence structure inside the canopy is characterized as non-Gaussian, intermittant and highly turbulent. This feature is supported by large turbulence intensities, skewness and kurtosis values and by the large infrequent sweeps and ejections that dominate tangential momentum transfer. Considerable day/night differences were observed in the vertical profiles of the mean streamwise wind velocity and turbulence intensities since the stability of the nocturnal boundary layer dampens turbulence above and within the canopy.  相似文献   

14.
A detailed analysis is presented of the horizontal wind fluctuations with periods 20 s to 1 hr, and their vertical structure as measured with light three-cup anemometers in a tropical forest environment. Information collected during the TREND (Tropical Environmental Data) experiment in a monsoon dominated region, was utilized. A special attempt was made to extract information relevant for dispersion modeling. Variability parameters within and above the forest canopy under different stability conditions were derived. A similar analysis was performed for a nearby clearing, to facilitate comparison between relatively smooth and rough surfaces, under identical ambient conditions. A limited sample of data (7 days) was utilized, initially, to develop a methodology to be later applied on a comprehensive data base, spanning the whole monsoon cycle.  相似文献   

15.
16.
17.
18.
麻益民  郜永祺  李德新  胡景琳 《气象》1993,19(12):13-18
为了更好地了解大气与物质和能量交换,用二层三维超声风速温度仪测量了重庆市郊松林风速和温度脉动值。采样速率为每秒1次和11次,数字量记录。计算了湍流动最通量和热通量的日变化,以及湍流风速的统计量和功率谱。结果表明,冠层上动量通量向下传输,而冠层内大多向上传输;冠层内湍流风速u的三阶矩平均值大于零,w的小于零;冠层上无因次湍流风速分量u,w标准差和无因次湍流动能耗散率与局地Monin-Obukhov长  相似文献   

19.
Horizontal turbulence measurements obtained from 22 wind sensors located on 9 towers in a mountainous coastal area are described and categorized by stability and terrain. Vector wind time series are high-pass filtered, and lateral and longitudinal wind speed variance is calculated for averaging times ranging from 15 s to 2 h. Parameterizations of the functional dependence of variance on averaging time are discussed, and a modification of Panofsky's (1988) uniform terrain technique applicable to complex terrain is presented. The parameterization is applied to the data and shown to be more realistic than a less complicated power law technique. The parameter values are shown to be different than the flat terrain cases of Kaimal et al. (1972), and are primarily a function of sensor location within the complex terrain. The parameters are also examined in terms of their dependence upon season, stability, marine boundary-layer height, and measurement height.  相似文献   

20.
Comparison was made of the flux measurements of a closed-path CO2/H2O analyzer and an open-path H2O analyzer above a clover field and the forest floor of a Douglas-fir stand. The attenuation of the gas concentration fluctuations caused by the sampling tube of the closed-path analyzer resulted in underestimation of the H20 flux above both surfaces. The degree of underestimation above the clover field depended on wind speed, but was smaller than that calculated from the transfer function for laminar flow in a circular tube and the scalar cospectrum in the neutral and unstable surface layer. Above the forest floor CO2 fluctuations led those of H2O by 0.7s. The implications of this are discussed regarding the determination of the time delay caused by the sampling tube of the closedpath analyzer. The day-time CO2 efflux from the forest floor, averaged over three days, was 0.043 mg/(m2s).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号