首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Subsurface temperatures were analyzed to evaluate the effects of urbanization and groundwater flow in Osaka, the second largest metropolitan in Japan. The temperature-depth profiles were classified into three (recharge, intermediate and discharge) types based on the thermal gradient, shape of the profiles, and temperature itself. The locations of the three types of profiles represent the places of regional and local groundwater flow systems in Osaka plain. The analyses of subsurface temperature using heat conduction-convection theory under the condition of surface warming showed that the depth of minimum temperature in the profile increased with the groundwater recharge rate and time lapse from the beginning of surface warming due to urbanization. Comparisons between observed and estimated temperature profiles showed that the surface warming due to urbanization is larger and occurred earlier in the middle of the city than those in surrounding area, which agreed with the air temperature records.  相似文献   

2.
Groundwater temperature is an important water quality parameter that affects species distributions in subsurface and surface environments. To investigate the response of subsurface temperature to atmospheric climate change, an analytical solution is derived for a one‐dimensional, transient conduction–advection equation and verified with numerical methods using the finite element code SUTRA. The solution can be directly applied to forward model the impact of future climate change on subsurface temperature profiles or inversely applied to produce a surface temperature history from measured borehole profiles. The initial conditions are represented using superimposed linear and exponential functions, and the boundary condition is expressed as an exponential function. This solution expands on a classic solution in which the initial and boundary conditions were restricted to linear functions. The exponential functions allow more flexibility in matching climate model projections (boundary conditions) and measured temperature–depth profiles (initial conditions). For example, measured borehole temperature data from the Sendai Plain and Tokyo, Japan, were used to demonstrate the improved accuracy of the exponential function for replicating temperature–depth profiles. Also, the improved accuracy of the exponential boundary condition was demonstrated using air temperature anomaly data from the Intergovernmental Panel on Climate Change. These air temperature anomalies were then used to forward model the effect of surficial thermal perturbations in subsurface environments with significant groundwater flow. The simulation results indicate that recharge can accelerate shallow subsurface warming, whereas upward groundwater discharge can enhance deeper subsurface warming. Additionally, the simulation results demonstrate that future groundwater temperatures obtained from the proposed analytical solution can deviate significantly from those produced with the classic solution. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
Long‐term heating of shallow urban aquifers is observed worldwide. Our measurements in the city of Cologne, Germany revealed that the groundwater temperatures found in the city centre are more than 5 K higher than the undisturbed background. To explore the role of groundwater flow for the development of subsurface urban heat islands, a numerical flow and heat transport model is set up, which describes the hydraulic conditions of Cologne and simulates the transient evolution of thermal anomalies in the urban ground. A main focus is on the influence of horizontal groundwater flow, groundwater recharge and trends in local ground warming. To examine heat transport in groundwater, a scenario consisting of a local hot spot with a length of 1 km of long‐term ground heating was set up in the centre of the city. Groundwater temperature‐depth profiles at upstream, central and downstream locations of this hot spot are inspected. The simulation results indicate that the main thermal transport mechanisms are long‐term vertical conductive heat input, horizontal advection and transverse dispersion. Groundwater recharge rates in the city are low (<100 mm a?1) and thus do not significantly contribute to heat transport into the urban aquifer. With groundwater flow, local vertical temperature profiles become very complex and are hard to interpret, if local flow conditions and heat sources are not thoroughly known. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
A simple numerical model is presented for estimating vertical groundwater flux from transient subsurface temperature profiles obtained from field measurements. The model developed utilizes the MacCormack scheme, which is based on the Finite Difference Method (FDM), for solving the governing partial differential equation of convection–diffusion heat transport with appropriate initial and boundary conditions within the subsurface. In order to validate the model, numerical solutions obtained for the study area located in the Nagoka plain, Japan are compared with the published measured data and results obtained by others. Results obtained show good agreement and fit the observed data with a correlation coefficient, R2, of 0·88. The estimated groundwater flux is 1·85 × 10−7 m s−1. Sensitivity analyses were also carried out to investigate the effect of variations in groundwater fluxes, thermal properties and the annual thermal variability due to climatic changes on the transient subsurface temperature profiles and to have a better understanding of the subsurface thermal dynamics. A substantial effect of annual climatic variability is observed on the temporal distributions of temperature depth profiles, and a better estimate of thermal parameters is required to estimate vertical groundwater flux. The largest change in subsurface temperature depth profiles due to groundwater flux over a year is within ± 4 °C. The influence of groundwater flux on subsurface temperature distributions in space and time may be more pronounced in areas where the top of the saturated layer fluctuates considerably. Variation in thermal diffusivity results in temperature change up to ± 1·5% and may cause change in groundwater flux estimate by ± 18%. The model presented has merits over analytical solutions (type curve matching techniques) in terms of suitability and applicability to real field problems, and can be a good asset to hydrological models as quantifying groundwater recharge or deducing it from other quantities, such as rainfall, evapotranspiration and runoff, is often complicated. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

5.
Seven longitudinal water temperature tow surveys were conducted to attempt to identify the location of surface and subsurface river water exchanges along the length of the West River at the Cape Bounty Arctic Watershed Observatory, Melville Island, Nunavut, Canada (74°55′ N, 109°35′ W). Water temperature data were collected using a calibrated thermistor with an accuracy of ±0.002 °C (resolution <0.00005 °C) along the river during July 2014 in conjunction with stable water isotope sampling to support the thermal data and to determine the extent of surface water mixing from different sources such as precipitation, snowmelt, and surface/subsurface water contributions to the river. Atmospheric conditions were found to be the main contributor to seasonal temperature variance in the river, whereas tributary inflows and residual channel snow also had important thermal effects to river temperatures. Residual channel snow was a sustained source of cold water during much of the 2014 summer season (June–August) and substantially offset downstream warming. The longitudinal temperature profiles indicate notable changes to the thermal state of the river, which are interpreted to be indicative of subsurface and surface water exchange through inputs of relatively cold or warm water. Broadly, surface inflows were found to provide warmer water relative to the West River, and contributed to downstream warming of the river, along with downstream enrichment of δD and δ18O. Subsurface inflows provided cooler water relative to the river, and contributed to downstream depletion of δD and δ18O and downstream cooling of river temperatures. These results demonstrate that localized changes in river temperature, in conjunction with isotopic tracers, can be used to track channel–slope water interactions in Arctic hydrological systems, work previously limited to alpine and temperate settings.  相似文献   

6.
We calculated statistical average of thermal data to speculate regional thermal structure of the forearc area of the Japanese Islands. The three thermal statistical averages show a difference of a high thermal regime in the western part of forearc inner zone and a low in the Kanto forearc outer zone. The Kanto zone marks 18 K km−1 for mean geothermal gradient, 44 mW m−2 for mean heat flow, while the western inner zone shows 27 K km−1 for mean geothermal gradient, 63 mW m−2 for mean heat flow. The geothermal gradients of the Nobi Plain and the Osaka Plain in the western inner zone are 29 and 36 K km−1, respectively, while the value of the Kanto Plain in the Kanto zone is 21 K km−1. Taking account of the effect of accumulation of sediments, we see the difference in the thermal regime between the plains and conclude that the difference is significant. Heat flux in the crust depends on the volume of granite rich in radioactive elements. There are few granitic rocks in the Kanto zone, while granitic rocks are dominant in the western inner zone. The heat flow of 20 mW m−2 is attributed to the granitic rocks of about 8 km in thickness. There are two oceanic plate subductions of the Pacific plate and the Philippine Sea plate under the Kanto zone, while only the Philippine Sea plate has been subducting under the western inner zone. The model simulation based on thermal and subduction model shows a heat flow ranging 50-60 mW m−2 in the southwest Japan forarc area and a low value of about 20 mW m−2 in the northeast Japan forearc area. The heat flux from the cooling oceanic lithosphere depends on the age of plate. The Shikoku Basin, a part of the Philippine Sea plate, off the western inner zone is 15-30 Ma, while the Pacific plate off the Kanto zone is 122-132 Ma. Theoretically, heat flux values of 15 and 50 Ma oceanic plates range 60-120 mW m−2 and those of 122-132 Ma could be about 10 mW m−2. If the heat flux contribution from the Philippine Sea plate under the Kanto zone is smaller than the plate under the western inner zone, there could be a thermal regime difference in order of several tens of mW m−2. Conclusively, the cause of the difference of heat flux could be the uneven granitic rocks distribution and/or the difference of heat flux between the two subducting plate.  相似文献   

7.
High quality temperature measurements have been made to depths of 30 to 220 m at 42 sites in 62 observational hydrogeological wells in Alberta. The temperature profiles commonly show near-surface inversions with a minimum temperature at depths of 30 to 50 m. Thermal modelling suggests a surface temperature history with warming reaching 2°C over the past 30 to 60 years. Recent climate warming evident from the analysis of the air temperature data in the region seems to provide at least a partial explanation of the increased ground temperatures. A sudden increase of the surface ground temperature caused by land clearing may be the other explanation, although modelling of such a sudden increase can only explain the observed temperature-depth data if the onset of such warming is 20–30 years old, which is in disagreement with the history of land development in the studied area. The effect of near-surface inversions of the temperature profiles also has been observed in the forested areas. The above support the climate based effect. The superposition of the climatic effect and man-made activity effect upon the ground warming is a very complicated process calling for considerably more research.  相似文献   

8.
Groundwater flow advects heat, and thus, the deviation of subsurface temperatures from an expected conduction‐dominated regime can be analysed to estimate vertical water fluxes. A number of analytical approaches have been proposed for using heat as a groundwater tracer, and these have typically assumed a homogeneous medium. However, heterogeneous thermal properties are ubiquitous in subsurface environments, both at the scale of geologic strata and at finer scales in streambeds. Herein, we apply the analytical solution of Shan and Bodvarsson ( 2004 ), developed for estimating vertical water fluxes in layered systems, in 2 new environments distinct from previous vadose zone applications. The utility of the solution for studying groundwater‐surface water exchange is demonstrated using temperature data collected from an upwelling streambed with sediment layers, and a simple sensitivity analysis using these data indicates the solution is relatively robust. Also, a deeper temperature profile recorded in a borehole in South Australia is analysed to estimate deeper water fluxes. The analytical solution is able to match observed thermal gradients, including the change in slope at sediment interfaces. Results indicate that not accounting for layering can yield errors in the magnitude and even direction of the inferred Darcy fluxes. A simple automated spreadsheet tool (Flux‐LM) is presented to allow users to input temperature and layer data and solve the inverse problem to estimate groundwater flux rates from shallow (e.g., <1 m) or deep (e.g., up to 100 m) profiles. The solution is not transient, and thus, it should be cautiously applied where diel signals propagate or in deeper zones where multi‐decadal surface signals have disturbed subsurface thermal regimes.  相似文献   

9.
Subsurface temperature is affected by heat advection due to groundwater flow and surface temperature changes. To evaluate their effects, it was implemented the measurements of temperature-depth profile (T-D profile) and the continuous monitoring of soil temperature in the southern part of Kamchatka which has not affected by human activity. Additionally, stable isotopic compositions of surface water and groundwater were analyzed. T-D profile and stable isotopic compositions show groundwater flow system is differ from the shallow aquifer to the deep aquifer. In the shallow aquifer, T-D profile suggests the existence of upward groundwater flux. On the other hand, the annual variation of soil temperature is divided into the large variation period (VP) and the stable period (SP) by the magnitude of daily and seasonal variation. VP and SP correspond to the summer and the winter season, respectively, and it considers that the difference between VP and SP is caused by the effect of snow cover. Therefore, the T-D profile is affected by not only upward groundwater flux but also the surface warming particularly in the summer season (VP).  相似文献   

10.
Long-term (1961 – 1996) meteorological air temperature series together with the reconstructed ground surface temperature histories, obtained by inverting borehole temperature-depth profiles, were used to project regional patterns of the recent (climate) warming rate on the territory of the Czech Republic. The characteristic magnitude of the warming rate of 0.02 –0.03 K/yr was confirmed by the results of several years of monitoring the temperature in two experimental boreholes. The monitoring of shallow temperatures at depths of about 30 –40 m, i.e. below the reach of the seasonal surface temperature variations, can serve as an alternative tool of direct quantitative assessment of the present warming rate. The data also seem to sustain a potential man-made component contributing to the more pronounced recent warming rate observed in the areas of large agglomeration.  相似文献   

11.
12.
Ground Surface Temperature (GST) history in Poland was derived from the inversion of temperature-depth profiles in over 20 wells. Temperature histories for the period 1500 A.D. through 1977 A.D. agree well with the instrumental record of the surface-air temperature available for the last two centuries. A statistical correlation of the reconstructed histories (from the well temperature data) with the instrumental record (air temperature) from the homogeneous Warsaw series is high (>0.8). Functional space inversion (FSI) of the temperature data with depth shows that beginning in the early 19th century, temperatures warmed by 0.9 ± 0.1°C following a long period of colder climate before. The last number could be a minimal as higher warming was calculated using a simple model based on surface temperature for the observational period (homogenized Warsaw surface temperature series, Lorenc, 2000) and POM (pre-observational mean; Harris and Chapman, 1998) of –1.53oC below the 1951–1980 mean temperature level.  相似文献   

13.
Although Egypt is not characterized by abundant Cenozoic igneous activity, its location in the northeastern corner of the African plate suggests that it may possess geothermal resources, especially along its eastern margin. Regional geothermal exploration has been carried out in Egypt using the thermal gradient/heat flow technique and groundwater temperature/chemistry technique. In the thermal gradient/heat flow study, existing oil-well bottom-hole temperature data as well as subsurface temperature measurements in existing boreholes were utilized before special thermal gradient holes were drilled. Groundwater temperature and chemistry data were used to extend the geographic range of the direct subsurface thermal measurements. On a very modest budget, a regional thermal high has been discovered along the eastern margin of Egypt, and a local thermal anomaly has been discovered in this zone. Published geological information suggests that the sandstones of the Nubian Formation may be a suitable reservoir for geothermal fluids. The new data indicate that temperatures of 150°C or higher may be found in this reservoir in the Gulf of Suez and Red Sea coastal zone where it lies at a depth of 4 km and deeper.  相似文献   

14.
The flow of groundwater beneath barrier islands has been cited as a possible pathway for salt water and chemical exchange between a protected embayment and the open sea. Evidence is presented that identifies an exchange of groundwater through a highly permeable paleoinlet along the barrier beach of Cavallino, which separates the northern Venice Lagoon from the Adriatic Sea. We utilized both point measurements of submarine groundwater discharge (SGD) and a geophysical investigation of the subsurface resistivity to analyze the movement of saline groundwater. Discharge of groundwater and associated nutrients, was higher at the site of a former inlet than at a similar site along the barrier and modulated by the difference in tidal water level between the lagoon and Adriatic Sea. If the measured conditions are typical, storm surge barriers could potentially result in a saline groundwater flow of up to 1.5×106 m3 d−1 into the lagoon.  相似文献   

15.
Aufeis (also known as icings) are large sheet-like masses of layered ice that form in river channels in arctic environments in the winter as groundwater discharges to the land surface and subsequently freezes. Aufeis are important sources of water for Arctic river ecosystems, bolstering late summer river discharge and providing habitat for caribou escaping insect harassment. The aim of this research is to use numerical simulations to evaluate a conceptual model of subsurface hydrogeothermal conditions that can lead to the formation of aufeis. We used a conceptual model based on geophysical data from the Kuparuk aufeis field on the North Slope of Alaska to develop a two-dimensional heterogeneous vertical profile model of groundwater flow, heat transport, and freeze/thaw dynamics. Modelling results showed that groundwater can flow to the land surface through subvertical high permeability pathways during winter months when the lower permeability soils near the land surface are frozen. The groundwater discharge can freeze on the surface, contributing to aufeis formation throughout the winter. We performed sensitivity analyses on subsurface properties and surface temperature and found that aufeis formation is most sensitive to the volume of unfrozen water available in the subsurface and the rate at which the subsurface water travels to the land surface. Although a trend of warming air temperatures will lead to a greater volume of unfrozen subsurface water, the aufeis volume can be reduced under warming conditions if the period of time for which air temperatures are below freezing is reduced.  相似文献   

16.
Non-perennial streams comprise over half of the global stream network and impact downstream water quality. Although aridity is a primary driver of stream drying globally, surface flow permanence varies spatially and temporally within many headwater streams, suggesting that these complex drying patterns may be driven by topographic and subsurface factors. Indeed, these factors affect shallow groundwater flows in perennial systems, but there has been only limited characterisation of shallow groundwater residence times and groundwater contributions to intermittent streams. Here, we asked how groundwater residence times, shallow groundwater contributions to streamflow, and topography interact to control stream drying in headwater streams. We evaluated this overarching question in eight semi-arid headwater catchments based on surface flow observations during the low-flow period, coupled with tracer-based groundwater residence times. For one headwater catchment, we analysed stream drying during the seasonal flow recession and rewetting period using a sensor network that was interspersed between groundwater monitoring locations, and linked drying patterns to groundwater inputs and topography. We found a poor relationship between groundwater residence times and flowing network extent (R2 < 0.24). Although groundwater residence times indicated that old groundwater was present in all headwater streams, surface drying also occurred in each of them, suggesting old, deep flowpaths are insufficient to sustain surface flows. Indeed, the timing of stream drying at any given point typically coincided with a decrease in the contribution from near-surface sources and an increased relative contribution of groundwater to streamflow at that location, whereas the spatial pattern of drying within the stream network typically correlated with locations where groundwater inputs were most seasonally variable. Topographic metrics only explained ~30% of the variability in seasonal flow permanence, and surprisingly, we found no correlation with seasonal drying and down-valley subsurface storage area. Because we found complex spatial patterns, future studies should pair dense spatial observations of subsurface properties, such as hydraulic conductivity and transmissivity, to observations of seasonal flow permanence.  相似文献   

17.
In northern regions, transportation infrastructure can experience severe structural damages due to permafrost degradation. Water infiltration and subsurface water flow under an embankment affect the energy balance of roadways and underlying permafrost. However, the quantification of the processes controlling these changes and a detailed investigation of their thermal impacts remain largely unknown due to a lack of available long-term embankment temperature data in permafrost regions. Here, we report observations of heat advection linked to surface water infiltration and subsurface flow based on a 9-year (from 2009 to 2017) thermal monitoring at an experimental road test site built on ice-rich permafrost conditions in southwestern Yukon, Canada. Our results show that snowmelt water infiltration in the spring rapidly increases temperature in the upper portion of the embankment. The earlier disappearance of snow deposited at the embankment slope increases the thawing period and the temperature gradient in the embankment compared with the natural ground. Infiltrated summer rainfall water lowered the near-surface temperatures and subsequently warmed embankment fill materials down to 3.6-m depth. Heat advection caused by the flow of subsurface water produced warming rates at depth in the embankment subgrade up to two orders of magnitude faster than by atmospheric warming (heat conduction). Subsurface water flow promoted permafrost thawing under the road embankment and led to an increase in active layer thickness. We conclude that the thermal stability of roadways along the Alaska Highway corridor is not maintainable in situations where water is flowing under the infrastructure unless mitigation techniques are used. Severe structural damages to the highway embankment are expected to occur in the next decade.  相似文献   

18.
Summary The results of geothermal research carried out in South Siberia (West-Siberian and Siberian Platforms, Altai-Sayan folded area and the Baikalian arched uplift zone) were employed to calculate the Earth's crustal temperatures. It is shown that temperature is a function of the heat flow value. The maps of the surface heat flow and the temperatures at the Moho discontinuity are presented and characteristic temperature-depth profiles were compiled for specific tectonic areas. The West-Siberian and Siberian Platforms, as well as the Altai-Sayan folded region are characterized by rather low heat flow, 42–50mW m –2 (1.0–1.2 µcal/cm 2 s), and low temperatures at the Moho boundary.400–500 °C. The thermal conditions in the area of Lake Baikal are extreme, the heat flow reaches here100–142 mW m –2 (2.4–3.4 µcal/cm 2 s), and the temperature at the crust's bottom may exceed1000 °C. The Moho-surface according to our calculations is nonisothermal.  相似文献   

19.
The eastern Pontides orogenic belt is one of the most complex geodynamic settings in the Alpine–Himalayan belt due to the lack of systematical geological and geophysical data. In this study, 1D crustal structure and P-wave velocity distribution obtained from gravity modeling and seismological data in the area has been used for the development of the thermal model of the eastern Pontides orogenic belt. The computed temperature-depth profiles suggest a temperature of 590?±?60°C at a Moho depth of 35?km indicates the presence of a brittle-ductile transition zone. This temperature value might be related to water in the subducted crust of the Tethys oceanic lithosphere. The Curie temperature depth value of 29?km, which may correspond to the crustal magma chambers, is found 5–7?km below the Moho depth. Surface heat flow density values vary from 66.5 and 104.7?mW?m?2. High mantle heat flow density value of 48?mW?m?2 is obtained for the area should be related to melting of the lithospheric mantle caused by upwelling of asthenosphere.  相似文献   

20.
Heat flow anomalies and their interpretation   总被引:1,自引:0,他引:1  
More than 10,000 heat flow determinations exist for the earth and the data set is growing steadily at about 450 observations per year. If heat flow is considered as a surface expression of geothermal processes at depth, the analysis of the data set should reveal properties of those thermal processes. They do, but on a variety of scales. For this review heat flow maps are classified by 4 different horizontal scales of 10n km (n = 1, 2, 3 and 4) and attention is focussed on the interpretation of anomalies which appear with characteristic dimensions of 10(n − 1) km in the respective representations.The largest scale of 104 km encompasses heat flow on a global scale. Global heat loss is 4 × 1013 W and the process of sea floor spreading is the principal agent in delivering much of this heat to the surface. Correspondingly, active ocean ridge systems produce the most prominent heat flow anomalies at this scale with characteristic widths of 103 km. Shields, with similar dimensions, exhibit negative anomalies.The scale of 103 km includes continent wide displays. Heat flow patterns at this scale mimic tectonic units which have dimensions of a few times 102 km, although the thermal boundaries between these units are sometimes sharp. Heat flow anomalies at this scale also result from plate tectonic processes, and are associated with arc volcanism, back arc basins, hot spot traces, and continental rifting. There are major controversies about the extent to which these surface thermal provinces reflect upper mantle thermal conditions, and also about the origin and evolution of the thermal state of continental lithosphere.Beginning with map dimensions of 102 km thermal anomalies of scale 101 km, which have a definite crustal origin, become apparent. The origin may be tectonic, geologic, or hydrologic. Ten kilometers is a common wavelength of topographic relief which drives many groundwater flow systems producing thermal anomalies. The largest recognized continental geothermal systems have thermal anomalies 101 km wide and are capable of producing hundreds of megawatts of thermal energy.The smallest scale addressed in this paper is 101 km. Worldwide interest in exploiting geothermal systems has been responsible for a recent accumulation of heat flow data on the smallest of scales considered here. The exploration nature of the surveys involve 10's of drillholes and reveal thermal anomalies having widths of 100 km. These are almost certainly connected to surface and subsurface fluid discharge systems which, in spite of their restricted size, are typically delivering 10 MW of heat to the near surface environment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号