In Belgium, IWVA uses managed aquifer recharge (MAR) to recharge the aquifer with treated wastewater generated from the communities to sustain the potable water supply on the Belgian coast. This MAR facility is faced with a challenge of reduced infiltration rates during the winter season when pond water temperatures near 4°C. This study involves the identification of the predominant factor influencing the rate of infiltration through the pond bed. Several factors, including pumping rates, natural recharge, tidal influences of the North Sea and pond-water temperature, were identified as potential causes for variation of the recharge rate. Correlation statistics and linear regression analysis were used to determine the sensitivity of the infiltration rate to the aforementioned factors. Two groundwater flow models were developed in visual MODFLOW to simulate the water movement under the pond bed and to obtain the differences in flux to track the effects of variation of hydraulic conductivity during the two seasons. A 32% reduction in vertical hydraulic gradient in the top portion of the aquifer was observed in winter, causing the recharge rates to fluctuate. Results showed that water temperature caused a 30% increase in hydraulic conductivity in summer as compared with winter and has the maximum impact on infiltration rate. Cyclic variations in water viscosity, occurring because of seasonal temperature changes, influence the saturated hydraulic conductivity of the pond bed. Results from the models confirm the impact on infiltration rate by temperature-influenced hydraulic conductivity.  相似文献   

2.
Infiltration rate is the key parameter that describes how water moves from the surface into a groundwater aquifer during managed aquifer recharge (MAR). Characterization of infiltration rate heterogeneity in space and time is valuable information for MAR system operation. In this study, we utilized fiber optic distributed temperature sensing (FO‐DTS) observations and the phase shift of the diurnal temperature signal between two vertically co‐located fiber optic cables to characterize infiltration rate spatially and temporally in a MAR basin. The FO‐DTS measurements revealed spatial heterogeneity of infiltration rate: approximately 78% of the recharge water infiltrated through 50% of the pond bottom on average. We also introduced a metric for quantifying how the infiltration rate in a recharge pond changes over time, which enables FO‐DTS to be used as a method for monitoring MAR and informing maintenance decisions. By monitoring this metric, we found high‐spatial variability in how rapidly infiltration rate changed during the test period. We attributed this variability to biological pore clogging and found a relationship between high initial infiltration rate and the most rapid pore clogging. We found a strong relationship (R2 = 0.8) between observed maximum infiltration rates and electrical resistivity measurements from electrical resistivity tomography data taken in the same basin when dry. This result shows that the combined acquisition of DTS and ERT data can improve the design and operation of a MAR pond significantly by providing the critical information needed about spatial variability in parameters controlling infiltration rates.  相似文献   

3.
Spreading‐basin methods have resulted in more than 130 million cubic metres of recharge to the unconfined Navajo Sandstone of southern Utah in the past decade, but infiltration rates have slowed in recent years because of reduced hydraulic gradients and (or) clogging. Trench infiltration is a promising alternative technique for increasing recharge and minimizing evaporation. This paper uses a variably saturated flow model to further investigate the relative importance of the following variables on rates of trench infiltration to unconfined aquifers: saturated hydraulic conductivity, trench spacing and dimensions, initial water‐table depth, alternate wet/dry periods, and number of parallel trenches. Modelling results showed (1) increased infiltration with higher hydraulic conductivity, deeper initial water tables, and larger spacing between parallel trenches, (2) deeper or wider trenches do not substantially increase infiltration, (3) alternating wet/dry periods result in less overall infiltration than keeping the trenches continuously full, and (4) larger numbers of parallel trenches within a fixed area increases infiltration but with a diminishing effect as trench spacing becomes tighter. An empirical equation for estimating expected trench infiltration rates as a function of hydraulic conductivity and initial water‐table depth was derived and can be used for evaluating feasibility of trench infiltration in other hydrogeologic settings. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
Artificial recharge of groundwater is an increasingly important method for augmenting groundwater supply and can have a positive or negative influence on the quality of water resources. We instrumented a managed aquifer recharge (MAR) pond in central coastal California to assess how patterns of infiltration and recharge affect the load of nitrate delivered to the underlying aquifer. The concentration of nitrate in infiltrating water consistently decreased during passage through the first metre of subsurface soils. Enrichment of 18O and 15 N in the residual nitrate in infiltrating water proceeded in a ratio of 1:2, indicating that denitrification plays a significant role in the quantitative reduction of nutrients exported during infiltration through shallow soils. The extent and rate of nitrate removal was spatially and temporally variable across the bottom of the recharge pond, with 30% to 60% of the nitrate load being removed over the first 6 weeks of managed aquifer recharge operation. During the period of highest N loading to the system, when the average infiltration rate was > 1 m/day, the recharge pond achieved a load reduction efficiency of 7 kg NO3?‐N/day/ha, which compares favourably to nitrate load reductions achieved by treatment wetlands. Groundwater mounding and water composition below the recharge pond suggest that recharge and subsequent lateral transport occur heterogeneously in the underlying aquifer. Nitrate concentrations in the aquifer following infiltration were lowered primarily by dilution, with little evidence for additional denitrification occurring in the aquifer in comparison to high rates documented during shallow infiltration. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
Analysis of water movement in paddy rice fields (I) experimental studies   总被引:2,自引:0,他引:2  
For the purpose of increasing the amount of ground water recharge, we investigated the hydraulic characteristics of water infiltration in a flooded paddy rice field in Ten-Chung, Chung-Hwa county, Taiwan. Experimental results based on mini-tensiometers and double ring infiltrometer measurements indicated that the least permeable layer occurred at the interface of the puddled topsoil and non-puddled subsoil. The average thickness of this layer was about 7.5 cm and saturated hydraulic conductivity ranged from 0.034 to 0.083 cm/day. Vertical infiltration flow was saturated within the plow sole layer and became unsaturated in the subsoil below the plow sole layer. The hydraulic conductivity of the subsoil, 20–30 times greater than that of the plow sole layer, revealed that the subsoil was more permeable than the plow sole layer. In situ measurements also demonstrated that breakage of the plow sole layer increased infiltration rate by a factor of 3.7. Increasing ponded water depth from 6 to 16 cm increased infiltration 1.5 fold. It is suggested that using the fallow paddy rice fields without puddling is a feasible way to enhance groundwater recharge, but for cultivated paddy rice fields, breaking the plow sole needs further study in terms of its recoverability and because of the potential contamination of the shallow aquifer by agrochemicals. The experimental data can be applied in numerical simulation models to quantify detailed water movement mechanisms and accurately estimate the amount of ground water recharge in paddy rice fields.  相似文献   

6.
We studied the problem of local‐ and field‐scale infiltration over a particular class of heterogeneous soils. At the local scale, the soils are described as being vertically non‐uniform, with the saturated hydraulic conductivity continuously decreasing with depth according to a power law function. Analogous to the Green–Ampt model, analytical expressions are first developed for local‐scale infiltration using a sharp front approximation, and model results are compared with numerical solutions of the Richards equation. These results show that saturation does not occur from below in soils with such vertical non‐uniformity, thereby allowing for the use of a sharp front approximation. Because of vertical non‐uniformity, ponding conditions are achieved locally even for rainfall rates less than the surface saturated hydraulic conductivity. Furthermore, infiltration rates asymptotically approach zero at long times. To determine field‐scale infiltration properties, the spatial variability in the surface saturated hydraulic conductivity is represented by a log‐normal random field. Using cumulative infiltration as the independent variable, expressions are developed for the ensemble mean of field‐scale infiltration and the expected time for a given depth of water to infiltrate over the field. Surface horizontal heterogeneity is found to control field‐scale infiltration at small times, whereas local vertical non‐uniformity exerts a strong control at long times. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
Simulating groundwater flow in basin‐fill aquifers of the semiarid southwestern United States commonly requires decisions about how to distribute aquifer recharge. Precipitation can recharge basin‐fill aquifers by direct infiltration and transport through faults and fractures in the high‐elevation areas, by flowing overland through high‐elevation areas to infiltrate at basin‐fill margins along mountain fronts, by flowing overland to infiltrate along ephemeral channels that often traverse basins in the area, or by some combination of these processes. The importance of accurately simulating recharge distributions is a current topic of discussion among hydrologists and water managers in the region, but no comparative study has been performed to analyze the effects of different recharge distributions on groundwater simulations. This study investigates the importance of the distribution of aquifer recharge in simulating regional groundwater flow in basin‐fill aquifers by calibrating a groundwater‐flow model to four different recharge distributions, all with the same total amount of recharge. Similarities are seen in results from steady‐state models for optimized hydraulic conductivity values, fit of simulated to observed hydraulic heads, and composite scaled sensitivities of conductivity parameter zones. Transient simulations with hypothetical storage properties and pumping rates produce similar capture rates and storage change results, but differences are noted in the rate of drawdown at some well locations owing to the differences in optimized hydraulic conductivity. Depending on whether the purpose of the groundwater model is to simulate changes in groundwater levels or changes in storage and capture, the distribution of aquifer recharge may or may not be of primary importance.  相似文献   

8.
Xi Chen  Xunhong Chen   《Journal of Hydrology》2003,280(1-4):246-264
During a flood period, stream-stage increases induce infiltration of stream water into an aquifer; subsequent declines in stream stage cause a reverse motion of the infiltrated water. This paper presents the results of the water exchange rate between a stream and aquifer, the storage volume of the infiltrated stream water in the surrounding aquifer (bank storage), and the storage zone. The storage zone is the part of aquifer where groundwater is replaced by stream water during the flood. MODFLOW was used to simulate stream–aquifer interactions and to quantify rates of stream infiltration and return flow. MODPATH was used to trace the pathlines of the infiltrated stream water and to determine the size of the storage zone. Simulations were focused on the analyses of the effects of the stream-stage fluctuation, aquifer properties, the hydraulic conductivity of streambed sediments, regional hydraulic gradients, and recharge and evapotranspiration (ET) rates on stream–aquifer interactions. Generally, for a given stream–aquifer system, larger flow rates result from larger stream-stage fluctuations; larger storage volumes and storage zones are produced by larger and longer-lasting fluctuations. For a given stream-stage hydrograph, a lower-permeable streambed, an aquitard, or an anisotropic aquifer of low vertical hydraulic conductivity can significantly reduce the rate of infiltration and limit the size of the storage zone. The bank storage solely caused by the stage fluctuation differs slightly between gaining and losing streams. Short-term rainfall recharge and ET loss in the shallow groundwater slightly influence on the flow rate, but their effects on bank storage in a larger area for a longer period can be considerable.  相似文献   

9.
ABSTRACT

An infiltration model based on the Green-Ampt assumptions is developed for a class of non-uniform soils in which saturated hydraulic conductivity decreases as an exponential function of depth, and the storage-suction factor C = ΔθΔΨ is a constant. An analysis of measured hydraulic conductivity and porosity data suggests that the model may be useful in some soils where the changes of hydraulic characteristics with depth are of this form. A method for using the model with time variable rainfall rates is given. The model is applied to simulate the experimental results of Childs &; Bybordi (1969) who measured infiltration into layered sand profiles. Agreement was satisfactory even for this case.  相似文献   

10.
Artificial recharge through a thick, heterogeneous unsaturated zone   总被引:2,自引:0,他引:2  
Thick, heterogeneous unsaturated zones away from large streams in desert areas have not previously been considered suitable for artificial recharge from ponds. To test the potential for recharge in these settings, 1.3 x 10(6) m(3) of water was infiltrated through a 0.36-ha pond along Oro Grande Wash near Victorville, California, between October 2002 and January 2006. The pond overlies a regional pumping depression 117 m below land surface and is located where thickness and permeability of unsaturated deposits allowed infiltration and saturated alluvial deposits were sufficiently permeable to allow recovery of water. Because large changes in water levels caused by nearby pumping would obscure arrival of water at the water table, downward movement of water was measured using sensors in the unsaturated zone. The downward rate of water movement was initially as high as 6 m/d and decreased with depth to 0.07 m/d; the initial time to reach the water table was 3 years. After the unsaturated zone was wetted, water reached the water table in 1 year. Soluble salts and nitrate moved readily with the infiltrated water, whereas arsenic and chromium were less mobile. Numerical simulations done using the computer program TOUGH2 duplicated the downward rate of water movement, accumulation of water on perched zones, and its arrival at the water table. Assuming 10 x 10(6) m(3) of recharge annually for 20 years, a regional ground water flow model predicted water level rises of 30 m beneath the ponds, and rises exceeding 3 m in most wells serving the nearby urban area.  相似文献   

11.
Dissolved helium and bromide tracers were used to evaluate trapped gas during an infiltration pond experiment. Dissolved helium preferentially partitioned into trapped gas bubbles, or other pore air, because of its low solubility in water. This produced observed helium retardation factors of as much as 12 relative to bromide. Numerical simulations of helium breakthrough with both equilibrium and kinetically limited advection/dispersion/retardation did not match observed helium concentrations. However, better fits were obtained by including a decay term representing the diffusive loss of helium through interconnected, gas-filled pores. Calculations indicate that 7% to more than 26% of the porosity beneath the pond was filled with gas. Measurements of laboratory hydraulic properties indicate that a 10% decrease in saturation would reduce the hydraulic conductivity by at least one order of magnitude in the well-sorted sandstone, but less in the overlying soils. This is consistent with in situ measurements during the experiment, which show steeper hydraulic gradients in sandstone than in soil. Intrinsic permeability of the soil doubled during the first six months of the experiment, likely caused by a combination of dissolution and thermal contraction of trapped gas. Managers of artificial recharge basins may consider minimizing the amount of trapped gas by using wet, rather than dry, tilling to optimize infiltration rates, particularly in well-sorted porous media in which reintroduced trapped gas may cause substantial reductions in permeability. Trapped gas may also inhibit the amount of focused infiltration that occurs naturally during ephemeral flood events along washes and playas.  相似文献   

12.
This study presents an extension of the concept of “quasi-saturation” to a quasi-saturated layer, defined as the uppermost dynamic portion of the saturated zone subject to water table fluctuations. Entrapped air here may cause substantial reductions in the hydraulic conductivity (K) and fillable pore water. Air entrapment is caused by a rising water table, usually as a result of groundwater recharge. The most significant effects of entrapped air are recharge overestimation based on methods that use specific yield (Sy), such as the water table fluctuation method (WTF), and reductions in K values. These effects impact estimation of fluid flow velocities and contaminant migration rates in groundwater. In order to quantify actual groundwater recharge rates and the effects of entrapped air, numerical simulations with the FEFLOW (Version 7.0) groundwater flow model were carried out using a quasi-saturated layer for a pilot area in Rio Claro, Brazil. The calculated recharge rate represented 16% of the average precipitation over an 8-year period, approximately half of estimates using the WTF method. Air entrapment amounted to a fillable porosity of 0.07, significant lower that the value of 0.17 obtained experimentally for Sy. Numerical results showed that the entrapped air volume in the quasi-saturated layer can be very significant (0.58 of the air fraction) and hence can significantly affect estimates of groundwater recharge and groundwater flow rates near the water table.  相似文献   

13.
In glacial outwash deposits, the movement of ground water Is determined by small scale irregularities in the pattern of hydraulic conductivity. Permeability determinations on split spoon samples obtained from coring the site are not sufficient to predict the patchiness of flow since it cannot define continuity of the strata. The lattice work pattern can be determined by vertical profiling with direct ground water flow measurement. The rate and direction of flow is combined with head gradient changes to compute hydraulic conductivity changes across the site.
The results of the tests can be plotted on triangular graphs depicting the fundamental Darcy equation. The local conditions reflect a mathematical "patchiness" of hydraulic conductivity unique to outwash deposits.
The procedure was employed to determine flow characteristics and define the zone of contribution to porous bottom kettle lakes. The zone of contribution was defined by projecting backward from the vertical profiling and shallow measurements and taking into account the daily rain water recharge rate across the site.
For the unconfined aquifer north of the pond, shallow ground water flow measurements were necessary to define the recharge portion of the shoreline. Vertical profiling was required to define the recharge volume since the rate of flow was not even with depth. A simple differential equation for determining the recharge area is presented along with the calculations.  相似文献   

14.
During a 3 month recharge experiment related to conjunctive use of water resources, 1.5 × 106 T of imported water were percolated through a pond of 128 m by 128 m in the San Jacinto basin. The infiltration rates, which declined with time, averaged 1.9 m day−1, equivalent to four times the lowest laboratory-measured hydraulic conductivity of the fluvial deposits. Ponding altered the unimodal grain-size distribution at the ground surface to types without a dominant mode, but this redistribution did not always lead to reduction in conductivities, which varied over at least three orders of magnitude. The water table 80 m downstream from the ponding edge began to rise slowly 1 month after the start of ponding; it leveled off at 8 m above the pre-recharge water table depth of 75 m and did not recede 2 months after termination of ponding. Water levels in wells bottomed in the original vadose zone suggested that an inverted water table migrated downward to meet the rising water table. Minor, local perching occurred at 14 m depth, as indicated by the presence of moist ground near one monitoring well and by hydraulic responses during a 20 day intermission in percolation. As it percolated through the sediments, the imported northern California water gained Ca but lost Mg, so that the Mg/Ca ratio resembled that of local ground water. Such cation exchange has also been demonstrated by leaching experiments in the laboratory. However, the characteristics of the original source waters appear to be retained by D/H isotope ratios and Cl concentrations, as well as cross-plots of SO4 vs. Cl and B vs. Cl. Such unreactive tracers could serve to monitor transport and mixing of the chemically diverse water used in future recharge programs in the San Jacinto basin.  相似文献   

15.
The impact of three-dimensional subsurface heterogeneity in the saturated hydraulic conductivity on hillslope runoff generated by excess infiltration (so-called Hortonian runoff) is examined. A fully coupled, parallel subsurface–overland flow model is used to simulate runoff from an idealized hillslope. Ensembles of correlated, Gaussian random fields of saturated hydraulic conductivity are used to create uncertainty in spatial structure. A large number of cases are simulated in a parametric manner with the variance of the hydraulic conductivity varied over orders of magnitude. These cases include rainfall rates above, equal and below the geometric mean of the hydraulic conductivity distribution. These cases are also compared to theoretical representations of runoff production based on simple assumptions regarding (1) the rainfall rate and the value of hydraulic conductivity in the surface cell using a spatially-indiscriminant approach; and (2) a percolation-theory type approach to incorporate so-called runon. Simulations to test the ergodicity of hydraulic conductivity on hillslope runoff are also performed. Results show that three-dimensional stochastic representations of the subsurface hydraulic conductivity can create shallow perching, which has an important effect on runoff behavior that is different than previous two-dimensional analyses. The simple theories are shown to be very poor predictors of the fraction of saturated area that might runoff due to excess infiltration. It is also shown that ergodicity is reached only for a large number of integral scales (∼30) and not achieved for cases where the rainfall rate is less than the geometric mean of the saturated hydraulic conductivity.  相似文献   

16.
The mining industry has grown strongly in China in recent decades, resulting in large amounts of coal gangues, which cause water and soil pollution, soil erosion, and various other environmental problems. They are often used in reclamation projects in attempts to restore land damaged by mining, hence they are frequently present (in widely varying proportions) in the topsoil in areas around mines. Their presence can strongly affect key soil variables, including its bulk density, structure, water retention, water movement, and solute transport rates. In the study presented here, the effects of gangue contents on infiltration, saturated hydraulic conductivity, and solute transport parameters of a Chinese Loess plateau soil were examined. The results show that infiltration rates and saturated hydraulic conductivity decreased with increasing gangue content. The Peck–Watson equation modeled these relationships well, but Bouwer–Rice equations provided poorer matches with the acquired data. Cumulative infiltration over time was described well by both the Philip equation and Kostiakov equation. Both the simplified convection–dispersion equation and a two‐region model described the solute transport processes well. In addition, the dispersion increased, while both the Peclet number and mobile water fraction decreased, with increases in gangue contents.  相似文献   

17.
Numerical Modeling of Atoll Island Hydrogeology   总被引:3,自引:0,他引:3  
We implemented Ayers and Vachers' (1986) inclusive conceptual model for atoll island aquifers in a comprehensive numerical modeling study to evaluate the response of the fresh water lens to selected controlling climatic and geologic variables. Climatic factors include both constant and time-varying recharge rates, with particular attention paid to the effects of El Niño and the associated drought it brings to the western Pacific. Geologic factors include island width; hydraulic conductivity of the uppermost Holocene-age aquifer, which contains the fresh water lens; the depth to the contact with the underlying, and much more conductive, Pleistocene karst aquifer, which transmits tidal signals to the base of the lens; and the presence or absence of a semiconfining reef flat plate on the ocean side. Sensitivity analyses of steady-steady simulations show that lens thickness is most strongly sensitive to the depth to the Holocene-Pleistocene contact and to the hydraulic conductivity of the Holocene aquifer, respectively. Comparisons between modeling results and published observations of atoll island lens thicknesses suggest a hydraulic conductivity of approximately 50 m/d for leeward islands and approximately 400 m/d for windward islands. Results of transient simulations show that lens thickness fluctuations during average seasonal conditions and El Niño events are quite sensitive to island width, recharge rate, and hydraulic conductivity of the Holocene aquifer. In general, the depletion of the lens during drought conditions is most drastic for small, windward islands. Simulation results suggest that recovery from a 6-month drought requires about 1.5 years.  相似文献   

18.
Recent advancements in analytical solutions to quantify water and solute travel time distributions (TTDs) and the related StorAge Selection (SAS) functions synthesize catchment complexity into a simplified, lumped representation. Although these analytical approaches are efficient in application, they require rarely available long‐term and high‐frequency hydrochemical data for parameter estimation. Alternatively, integrated hydrologic models coupled to Lagrangian particle‐tracking approaches can directly simulate age under different catchment geometries and complexity, but at a greater computational expense. Here, we bridge the two approaches, using a physically based model to explore the uncertainty in the estimation of the SAS function shape. In particular, we study the influence of subsurface heterogeneity, interactions between distinct flow domains (i.e., the vadose zone and saturated groundwater), diversity of flow pathways, and recharge rate on the shape of TTDs and the SAS functions. We use an integrated hydrology model, ParFlow, linked with a particle‐tracking model, SLIM, to compute transient residence times (or ages) at every cell in the domain, facilitating a direct characterization of the SAS function. Steady‐state results reveal that the SAS function shape shows a wide range of variation with respect to the variability in the structure of subsurface heterogeneity. Ensembles of spatially correlated realizations of hydraulic conductivity indicate that the SAS functions in the saturated groundwater have an overall weak tendency toward sampling younger ages, whereas the vadose zone gives a strong preference for older ages. We further show that the influence of recharge rate on the TTD is tightly dependent on the variability of subsurface hydraulic conductivity.  相似文献   

19.
Analytical solutions for the water table and lateral discharge in a heterogeneous unconfined aquifer with time-dependent source and fluctuating river stage were derived and compared with those in an equivalent homogeneous aquifer. The heterogeneous aquifer considered consists of a number of sections of different hydraulic conductivity values. The source term and river stage were assumed to be time-dependent but spatially uniform. The solutions derived is useful in studying various groundwater flow problems in a horizontally heterogeneous aquifer since the spatially piecewise-constant hydraulic conductivity and temporally piecewise-constant recharge and lateral discharge can be used to quantify variations in these processes commonly observed in reality. Applying the solutions derived to an aquifer of three sections of different hydraulic conductivity values shown that (1) the aquifer heterogeneity significantly increases the spatial variation of the water table and thus its gradient but it has little effect on lateral discharge in the case of temporally and spatially uniform recharge, (2) the time-dependent but spatially uniform recharge increases the temporal variation of groundwater table over the entire aquifer but its effect on lateral discharge is limited in the zone near the river, and (3) the effect of river stage fluctuation on the water table and lateral discharge is limited in the zone near the river and the effect of the heterogeneity is to increase lateral discharge to or recharge from the river.  相似文献   

20.
A thorough understanding of rainfall recharge processes and their controlling factors is essential for management of groundwater systems. This study investigates the effects of various meteorological and hydrogeological factors on the gross recharge percentages, the rainfall–recharge relationships and the recharge threshold values for unconfined sandy aquifers under an equatorial climate. Among the meteorological factors investigated, rainfall intensity was found to have the most significant impact on the gross recharge rate. The effects of potential evaporation rate, relative humidity and air temperature on the gross recharge percentage were significant when the vadose zone thickness is larger than 2·5 m. The recharge threshold values were found to depend strongly on the vadose zone thickness. The rainfall–recharge relationships could generally be well defined by a normal–log relationship. The rainfall–recharge relationships derived here are applicable to yield estimates of gross recharge percentages for unconfined sandy aquifers under an equatorial climate, using rainfall intensity and vadose zone thickness as input variables. In this study, a theory was developed and validated to provide physical explanations for the observations, based on the residence time of the percolated rainwater within the vadose zone. Among the soil hydraulic parameters tested, porosity and saturated hydraulic conductivity were found to have the most pronounced effects on the gross recharge percentage. Utilizing the sensitivity results and the theory derived, an approach was developed for extending the application of the derived rainfall–recharge relationships to other sand textures. The approach was found to be capable of producing rough and fast estimations of gross recharge percentage for other sand textures. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   