首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The impact of lost circulation during rotary drilling near an existing monitoring well cluster was evaluated by periodic measurements of water levels and contaminant concentrations at the well cluster. Due to regulatory concerns, changes in water levels or VOC concentration in the well cluster during drilling would trigger monitoring well redevelopment. The borehole was drilled approximately 30 feet northeast of four nested monitoring wells that screen Devonian and Silurian carbonate bedrock at depths of 15, 60, 130, and 190 feet. Following complete circulation loss at depths of 177 and 1 S3 feet in the borehole, a rapid decrease in water levels was observed in the upper three monitoring wells. The water level in the well that was screened through the lost circulation zones increased slightly.
Decreasing water levels in formations located above the point of circulation loss appear to occur in response to a sudden decrease in borehole fluid pressure caused by the flow of drilling fluid into the formation. The relative contribution of contaminated formation water lo the borehole can be estimated by using the time-drawdown relationship and estimates of transmissivity. At the point of circulation loss, significant dilution of contaminant concentrations occurs from the loss of drilling fluid into the contaminated zone. Contaminated formation water entering the borehole during periods of complete lost circulation may mobilize contaminants from upper lo lower formations. Lost circulation into a formation would be signaled by a water level increase in monitoring wells. The wells would subsequently require development to remove the volume of fluid lost to the formation, including both drilling fluid and contaminated formation water. Monitoring wells exhibiting declining water levels following lost circulation would not require development since drilling water has not entered the zones screened by these wells.  相似文献   

2.
Efforts to sample representative, undisturbed distributions of uranium in ground water beneath the Fernald Environmemal Management Project (FEMP) prompted the application of a novel technique that is less invasive in the monitoring well. Recent studies (Kearl et al. 1992; Barcelona et al. 1994) indicate that representative samples can and should be collected without prior well volume exchange purging or borehole evacuation. Field experiments conducted at the FMMP demonstrate that under specific sampling conditions in a welldefined hydrogeologic system, representative ground water samples for a monitoring program can be obtained without removing the conventional three well volumes from the well. The assumption is made that indicator parameter equilibration may not be necessary to determine when to collect representative samples at the P'liMP. Preliminary results obtained from the field experiment suggest that this may be true. The technique employs low purge rates (< 1 L/min) with dedicated bladder pumps with inlets located in the screened interval of the well, while not disturbing the stagnant water column above the screened interval. If adopted, this technique, termed micro-purge low-flow sampling, will produce representative ground water samples, significantly reduce sampling costs, and minimize; waste water over the monitoring life cycle at the FEMP. This technique is well suited for sites that have been fully characterized and are undergoing long-term monitoring.  相似文献   

3.
Volatile organic compounds (VOCs) are present in multiple water-bearing zones beneath and downgradient of Lawrence Livermore National Laboratory. This area is composed of interfingering unconsolidated alluvial sediments with hydraulic conductivities ranging over four orders of magnitude. The more permeable sediments exhibit moderate hydraulic interconnection horizontally and less interconnection vertically, and appear to consist largely of interconnected stream channel deposits. To optimize selection of monitoring well screened intervals in this complex environment, a technique that enables collection of saturated formation samples from each water-bearing zone without contamination from other VOC-containing zones was developed, tested, and implemented. The technique utilizes a wireline punch-coring system that allows the drill bit to be replaced with a core barrel without removing the drill rod from the borehole. To help ensure that a sample from one water-bearing zone is not contaminated by VOCs from another zone, the drilling fluid is replaced with new fluid before each sampling run. Overnight chemical analysis by gas chromatography enables field personnel to know the vertical distribution of VOCs as drilling proceeds. Since its first use in 1985, the technique has successfully characterized the presence or absence of VOCs in ground water in 123 of 140 wells, many with concentrations in ground water in the low parts-per-billion range. Our sampling technique is a cost-effective and rapid method of evaluating the vertical distribution of VOCs in ground water in a complex hydrogeologic environment.  相似文献   

4.
Hollow-stem augers are a widely used drilling method for constructing monitoring wells in unconsolidated materials. The drilling procedures used when constructing monitoring wells with hollow-stem augers, however, are neither standardized nor thoroughly documented in the published literature.
Variations in drilling procedures and techniques may occur as a result of the: (1) type of auger drill equipment and formation samplers used; (2) hydrogeologic conditions at the site, especially where heaving sands occur; and (3) known or suspected presence of contaminated zones, where there is a potential for the vertical movement of contaminants within the borehole.
In a saturated zone in which heaving sands occur, changes in equipment and drilling techniques are required to provide a positive pressure head of water within the auger column. This may require the addition of clean water or other drilling fluid inside the augers.
When monitoring the quality of ground water below a known contaminated zone, hollow-stem auger drilling may not be advisable unless protective surface casing can be installed. Depending on the site hydrogeology, conventional hollow-stem auger drilling techniques alone may not be adequate for the installation of the protective surface casing. A hybrid drilling method may be needed that combines conventional hollow-stem auger drilling with a casing driving technique that advances the borehole and surface casing simultaneously.  相似文献   

5.
Leaf AT  Hart DJ  Bahr JM 《Ground water》2012,50(5):726-735
Subsurface heterogeneity in hydraulic properties and processes is a fundamental challenge in hydrogeology. We have developed an improved method of borehole dilution testing for hydrostratigraphic characterization, in which distributed temperature sensing (DTS) is used to monitor advective heat movement. DTS offers many advantages over conventional technologies including response times in the order of seconds rather than minutes, the ability to profile temperature synoptically in a well without disturbing the fluid column, sensitivity to a wider range of flow rates than conventional spinner and heat pulse flow meters, and the ease of interpretation. Open-well thermal dilution tests in two multiaquifer wells near Madison, Wisconsin, provided detailed information on the borehole flow regimes, including flow rates and the locations of inflows from both fractures and porous media. The results led to an enhanced understanding of flow in a hydrostratigraphic unit previously conceptualized as homogenous and isotropic.  相似文献   

6.
A model coupling fluid hydraulics in a borehole with fluid flow in an aquifer is developed in this paper. Conservation of momentum is used to create a one-dimensional steady-state model of vertical flow in an open borehole combined with radially symmetric flow in an aquifer and with inflow to the well through the wellbore screen. Both laminar and turbulent wellbore conditions are treated. The influence of inflow through the wellbore screen on vertical flow in the wellbore is included, using a relation developed by Siwoń (1987) . The influence of inflow reduces the predicted vertical variation in head up to 15% compared to a calculation of head losses due to fluid acceleration and the conventional Colebrook-White formulation of friction losses in a circular pipe. The wellbore flow model is embedded into the MODFLOW-2000 ground water flow code. The nonlinear conservation of momentum equations are iteratively linearized to calculate the conductance terms for vertical flow in the wellbore. The resulting simulations agree favorably with previously published results when the model is adjusted to meet the assumptions of the previous coupled models.  相似文献   

7.
A rapid-screening technique was developed to identify lithologies that best disperse artificial recharge via surface infiltration and minimize effects on ground water chemistry. The technique prospectively evaluates basin infiltration rates and water chemistry influences by integrating geotechnical, hydraulic, and water quality data with column test data and numerical modeling. The technique was validated using field data collected from surface infiltration basins designed to recharge ground water pumped from the Pipeline pit gold mine in Nevada. Observed recharge rates at these infiltration sites correlated most significantly with depth to groundwater, with basins in coarse-grained lithologies performing better (0.45 to 0.85 m/day) than those with fine-grained layers (< 0.30 m/day). Observed water quality resulting from leaching of the previously unsaturated vadose zone showed a transitory (< six months) increase in solute concentrations followed by a decrease to baseline conditions, a phenomenon also observed in column tests that leached native soils with local ground water. Leaching of fine-grained soils with evaporites resulted in greater solute concentrations (TDS > 2000 mg/L) than coarse-grained soils (< 1200 mg/L). The results of HYDRUS_2D simulations using the accumulated data as input were in agreement with observed ground water chemistry downgradient of the infiltration basins for a variety of lithologies. Sites for infiltration basins can be rapidly screened to include areas with greatest depth to groundwater and in coarsest alluvial sediments, and impact to ground water chemistry can be reliably predicted using computer modeling and column test results.  相似文献   

8.
Deep observation boreholes in the vicinity of active production wells in Honolulu, Hawaii, exhibit the anomalous condition that fluid-column electrical conductivity logs and apparent profiles of pore-water electrical conductivity derived from induction conductivity logs are nearly identical if a formation factor of 12.5 is assumed. This condition is documented in three boreholes where fluid-column logs clearly indicate the presence of strong borehole flow induced by withdrawal from partially penetrating water-supply wells. This result appears to contradict the basic principles of conductivity-log interpretation. Flow conditions in one of these boreholes was investigated in detail by obtaining flow profiles under two water production conditions using the electromagnetic flowmeter. The flow-log interpretation demonstrates that the fluid-column log resembles the induction log because the amount of inflow to the borehole increases systematically upward through the transition zone between deeper salt water and shallower fresh water. This condition allows the properties of the fluid column to approximate the properties of water entering the borehole as soon as the upflow stream encounters that producing zone. Because this condition occurs in all three boreholes investigated, the similarity of induction and fluid-column logs is probably not a coincidence, and may relate to aquifer response under the influence of pumping from production wells.  相似文献   

9.
Groundwater sampling from open boreholes in fractured‐rock aquifers is particularly challenging because of mixing and dilution of fluid within the borehole from multiple fractures. This note presents an alternative to traditional sampling in open boreholes with packer assemblies. The alternative system called ZONFLO (zonal flow) is based on hydraulic control of borehole flow conditions. Fluid from discrete fractures zones are hydraulically isolated allowing for the collection of representative samples. In rough‐faced open boreholes and formations with less competent rock, hydraulic containment may offer an attractive alternative to physical containment with packers. Preliminary test results indicate a discrete zone can be effectively hydraulically isolated from other zones within a borehole for the purpose of groundwater sampling using this new method.  相似文献   

10.
The Effect of Three Drilling Fluids on Ground Water Sample Chemistry   总被引:1,自引:0,他引:1  
Three monitoring wells were installed in borings that were constructed using water-based drilling fluids containing either (1) guar bean, (2) guar bean with breakdown additive, or (3) bentonite. These fluids were selected to observe their effect on the chemistry of subsequent water samples collected from the wells. The wells were installed to depths of 66 feet, 100.5 feet and 103 feet, respectively, in fine-to-medium sand and gravel outwash deposits near Antigo, Wisconsin. Drilling fluids were necessary to maintain an open borehole during well construction through strata containing cobbles and boulders.
The bentonite and guar drilling fluids caused temporarily elevated concentrations of chemical oxygen demand (COD) in ground water samples collected from the monitoring wells. Using standard development, purging and sampling procedures, elevated COD concentrations persisted for about 50 days for the well bored with the guar-with-additive fluid, 140 days for the bentonite well and 320 days for the guar well. Unfiltered ground water samples for all wells had greater concentrations of COD than samples filtered through a 0.45 micron filter. Sulfate concentrations also decreased with time in the guar-with-additive well and bentonite well, but not in the guar well.
The elevated COD concentrations are attributed to the large concentrations of oxidizable carbon present in the guar bean drilling fluid and in the organic polymers present in the bentonite drilling fluid. Well development and purging procedures, including borehole flushing, surging, bailing and/or chemically induced viscosity breakdown of the guar mud decreased the time before background conditions were achieved. Future research should evaluate the physical and geochemical interaction of different drilling fluid compositions with a variety of geologic matrices and drilling, well development and well purging techniques.  相似文献   

11.
Large-scale column experiments were undertaken to evaluate the potential of polymer mats to remove selected volatile organic compounds, polycyclic aromatic hydrocarbons, and pesticides (atrazine and fenamiphos) from ground water and potentially to act as permeable reactive barriers in contaminated ground water environments. The polymer mats, composed of interwoven silicone (dimethylsiloxane) tubes and purged with air, were installed in 2 m long flow-through columns. The polymer mats proved efficient in physically removing (stripping) benzene and naphthalene from contaminated water. Removal efficiencies for both these compounds from an aqueous phase flowing past a polymer mat were 75% or greater. However, for atrazine and fenamiphos, removal efficiencies were 5% or less, probably as a result of their lower Henry's law constants and possibly lower polymer diffusion coefficients.
These experiments indicate that, at least for relatively volatile compounds, polymer mats can provide a remediation technique for the removal of organic compounds from contaminated water. Application of this technique may be well suited as a longer-term, semipassive strategy to remediate contaminated ground water, using natural ground water flow to deliver contaminated ground water to polymer mats engineered as sorption-stripping barriers.
Additional benefits of this technique may include targeted delivery of gaseous chemical amendments, such as oxygen, to enhance aerobic biodegradation and to further reduce any residual concentrations of contaminants.  相似文献   

12.
Borehole television has been successfully utilized to gather in situ information on boreholes and wells in several ground water monitoring programs. Borehole television surveys are proposed as a viable alternative to other downhole instruments in the subsurface investigation stages of a ground water monitoring program.
The borehole television camera used by the authors was originally developed for use in the examination of nuclear reactor cores; the camera has since been modified for use in borehole investigations. The lens attachments are capable of looking sideward or downward and include built-in lighting assemblies. Use of the camera, lenses and various support equipment are discussed.
The in situ characterization of fractures that can provide pathways for contaminant migration poses a significant challenge. Borehole television inspection can provide information on the frequency, size and orientation of these fractures. Vertical correlations of rock cores in areas where voids are present (i.e. deep mining or karst topography) can also be simplified by this technique. In addition, borehole television can also be used to check monitoring well integrity. Casing inspections are especially useful where construction details are not known. Well screens may be inspected in place to determine if rusting has enlarged the screen openings or if screens have been damaged during emplacement or well development operations (i.e. surge block, air jetting, etc.). This information may prove to be very valuable in the decision to decommission a well. Examples of these successful applications in ground water monitoring programs at several Superfund hazardous waste sites are presented.  相似文献   

13.
Little is known about hydrogeochemical conditions beneath thick permafrost, particularly in fractured crystalline rock, due to difficulty in accessing this environment. The purpose of this investigation was to develop methods to obtain physical, chemical, and microbial information about the subpermafrost environment from a surface‐drilled borehole. Using a U‐tube, gas and water samples were collected, along with temperature, pressure, and hydraulic conductivity measurements, 420 m below ground surface, within a 535 m long, angled borehole at High Lake, Nunavut, Canada, in an area with 460‐m‐thick permafrost. Piezometric head was well above the base of the permafrost, near land surface. Initial water samples were contaminated with drill fluid, with later samples <40% drill fluid. The salinity of the non‐drill fluid component was <20,000 mg/L, had a Ca/Na ratio above 1, with δ18O values ~5‰ lower than the local surface water. The fluid isotopic composition was affected by the permafrost‐formation process. Nonbacteriogenic CH4 was present and the sample location was within methane hydrate stability field. Sampling lines froze before uncontaminated samples from the subpermafrost environment could be obtained, yet the available time to obtain water samples was extended compared to previous studies. Temperature measurements collected from a distributed temperature sensor indicated that this issue can be overcome easily in the future. The lack of methanogenic CH4 is consistent with the high sulfate concentrations observed in cores. The combined surface‐drilled borehole/U‐tube approach can provide a large amount of physical, chemical, and microbial data from the subpermafrost environment with few, controllable, sources of contamination.  相似文献   

14.
Strawberry Point, located on Hinchinbrook Island, Alaska, is the site of a Federal Aviation Administration air navigation facility that is contaminated with gasoline- and diesel-range hydrocarbons in soil and ground water. An air sparging system was installed to promote bioremediation in the zone of seasonal ground water fluctuation where the contaminant is concentrated. The sparge wells were placed in a homogeneous formation, consisting of fine-grain beach and eolian sands. The system was then evaluated to determine the ground water region of influence and optimum frequency of operation. Neutron probe borehole measurements of percentage; of fluid displacement during sparging at two wells revealed dynamic air distributions defined by an initial and relatively rapid expansion phase followed by a consolidation phase. Air distribution was stable within 12 hours after startup, reaching a peak air saturation of greater than 50 percent. The radius of peak expansion varied with time and depth, with measurable fluid displacement occurring beyond 12 feel from the sparge well near the water table. The percentage of air saturation stabilized within one hour following cutoff of the air flow, leaving pockets of entrapped air near the water table. When air injection was resumed, air saturation levels were found to be repeatable. The observations at this site indicated that the effective region of influence is relatively small and that frequent pulsing is needed to optimize oxygen distribution.  相似文献   

15.
Field-based experiments were designed to investigate the release of naturally occurring, low to moderate (< 50 microg/L) arsenic concentrations to well water in a confined sandstone aquifer in northeastern Wisconsin. Geologic, geochemical, and hydrogeologic data collected from a 115 m2 site demonstrate that arsenic concentrations in ground water are heterogeneous at the scale of the field site, and that the distribution of arsenic in ground water correlates to solid-phase arsenic in aquifer materials. Arsenic concentrations in a test well varied from 1.8 to 22 microg/L during experiments conducted under no, low, and high pumping rates. The quality of ground water consumed from wells under typical domestic water use patterns differs from that of ground water in the aquifer because of reactions that occur within the well. Redox conditions in the well can change rapidly in response to ground water withdrawals. The well borehole is an environment conducive to microbiological growth, and biogeochemical reactions also affect borehole chemistry. While oxidation of sulfide minerals appears to release arsenic to ground water in zones within the aquifer, reduction of arsenic-bearing iron (hydr)oxides is a likely mechanism of arsenic release to water having a long residence time in the well borehole.  相似文献   

16.
Cautions and Suggestions for Geochemical Sampling in Fractured Rock   总被引:2,自引:0,他引:2  
Collecting water samples for geochemical analyses in open bedrock boreholes or in discrete intervals of boreholes intersected by multiple fractures is likely to yield ambiguous results for ground water chemistry because of the variability in the transmissivity, storativity, and hydraulic head of fractures intersecting the borehole. Interpreting chemical analyses of water samples collected in bedrock boreholes requires an understanding of the hydraulic conditions in the borehole under the ambient flow regime in the aquifer as well as during sampling. Pumping in open boreholes, regardless of the pumping rate and the location of the pump intake, first draws water from the borehole and then from fractures intersecting the borehole. The time at which the volumetric rate of water entering the borehole from fractures is approximately equal to the pumping rate can be identified by monitoring the logarithm of drawdown in the borehole as a function of the logarithm of time. Mixing of water entering the borehole from fractures with water in the borehole must be considered in estimating the time at which the pump discharge is representative of aquifer water. In boreholes intersected by multiple fractures, after the contribution from the borehole volume has diminished, the contribution of fractures to the pump discharge will be weighted according to their transmissivity, regardless of the location of the pump intake. This results in a flux-averaged concentration in the pump discharge that is biased by the chemical signature of those fractures with the highest transmissivity. Under conditions where the hydraulic head of fractures varies over the length of the borehole, open boreholes will be subject to ambient flow in the water column in the borehole. In some instances, the magnitude of the ambient flow may be similar to the designated pumping rate for collecting water samples for geochemical analyses. Under such conditions, the contributions to the pump discharge from individual fractures will be a function not only of the transmissivity of the fractures, but also of the distribution of hydraulic head in fractures intersecting the borehole. To reduce or eliminate the deleterious effects of conducting geochemical sampling in open boreholes, a straddle-packer apparatus that isolates a single fracture or a series of closely spaced fractures is recommended. It is also recommended that open boreholes be permanently outfitted with borehole packers or borehole liners in instances where maintaining the hydraulic and chemical stratification in the aquifer is of importance. In a field example, a comparison of results from sampling in an open borehole and in discrete intervals of the same borehole showed dramatic differences in the concentrations of chemical constituents in the water samples, even though chemical field parameters stabilized prior to both open borehole and discrete interval sampling.  相似文献   

17.
Noncontaminating procedures were used during the hollow-stem auger installation of 12 observation wells on three hazardous waste sites in Kansas. Special precautions were taken to ensure that water samples were representative of the ground water in the aquifer and were not subjected to contamination from the land surface or cross contamination from within borehole. Precautions included thorough cleaning of the hollow-stem auger and casing, keeping drill cuttings from falling back into the borehole while drilling, and not adding water to the borehole. These procedures were designed to prevent contamination of the ground water during well installation.
Because the use of water during well installation could contaminate the aquifer or dilute contaminants already present in the aquifer, two methods of well installation that did not introduce outside water to the borehole were used. The first method involved using a slotted 3/4-inch coupling that was attached to the bit plate of the hollow-stem auger, allowing formation water to enter the auger, thereby preventing sand-plug formation. This method proved to be adequate, except when drilling through clay layers, which tended to clog the slotted coupling. The second method involved screened well swab that allowed only formation water to enter the hollow-stem auger and prevented sand from plugging the hollow-stem auger when the bit plate was removed.  相似文献   

18.
State-of-the-art analytical techniques are capable of detecting contamination In the part per billion (ppb) range or lower. At these levels, a truly representative ground water sample Is essential to precisely evaluate ground water quality. The design specifications of a ground water monitoring system are critical in ensuring the collection of representative samples, particularly throughout the long-term monitoring period.
The potential interfaces from commonly used synthetic well casings require a thorough assessment of site, hydrogeology and the geochemical properties of ground water. Once designed, the monitoring system must be installed following guidelines that ensure adequate seals to prevent contaminant migration during the installation process or at some time in the future. Additionally, maintaining the system so the wells are in hydraulic connection with the monitored zone as well as periodically Inspecting the physical integrity of the system can prolong the usefulness of the wells for ground water quality. When ground water quality data become suspect due to potential interferences from existing monitoring wells, an appropriate abandonment technique must be employed to adequately remove or destroy the well while completely sealing the borehole.
The results of an inspection of a monitoring system comprised of six 4-inch diameter PVC monitoring wells at a hazardous well facility Indicated that the wells were improperly installed and in some cases provided a pathway for contamination. Subsequent down hole television inspections confirmed inaccuracies between construction logs and the existing system as well as identified defects in casing materials. An abandonment program was designed which destroyed the well casings in place while simultaneously providing a competent seal of the re-drilled borehole.  相似文献   

19.
Boreholes drilled through contaminated zones in fractured rock create the potential for vertical movement of contaminated ground water between fractures. The usual assumption is that purging eliminates cross contamination; however, the results of a field study conducted in a trichloroethylene (TCE) plume in fractured sandstone with a mean matrix porosity of 13% demonstrates that matrix-diffusion effects can be strong and persistent. A deep borehole was drilled to 110 m below ground surface (mbgs) near a shallow bedrock well containing high TCE concentrations. The borehole was cored continuously to collect closely spaced samples of rock for analysis of TCE concentrations. Geophysical logging and flowmetering were conducted in the open borehole, and a removable multilevel monitoring system was installed to provide hydraulic-head and ground water samples from discrete fracture zones. The borehole was later reamed to complete a well screened from 89 to 100 mbgs; persistent TCE concentrations at this depth ranged from 2100 to 33,000 microg/L. Rock-core analyses, combined with the other types of borehole information, show that nearly all of this deep contamination was due to the lingering effects of the downward flow of dissolved TCE from shallower depths during the few days of open-hole conditions that existed prior to installation of the multilevel system. This study demonstrates that transfer of contaminant mass to the matrix by diffusion can cause severe cross contamination effects in sedimentary rocks, but these effects generally are not identified from information normally obtained in fractured-rock investigations, resulting in potential misinterpretation of site conditions.  相似文献   

20.
Characterization of a multilayer aquifer using open well dilution tests   总被引:1,自引:0,他引:1  
West LJ  Odling NE 《Ground water》2007,45(1):74-84
An approach to characterization of multilayer aquifer systems using open well borehole dilution is described. The approach involves measuring observation well flow velocities while a nearby extraction well is pumped by introducing a saline tracer into observation wells and collecting dilution vs. depth profiles. Inspection of tracer profile evolution allows discrete permeable layers within the aquifer to be identified. Dilution profiles for well sections between permeable layers are then converted into vertical borehole flow velocities and their evolution, using an analytic solution to the advection-dispersion equation applied to borehole flow. The dilution approach is potentially able to measure much smaller flow velocities that would be detectable using flowmeters. Vertical flow velocity data from the observation wells are then matched to those generated using a hydraulic model of the aquifer system, "shorted" by the observation wells, to yield the hydraulic properties of the constituent layers. Observation well flow monitoring of pumping tests represents a cost-effective alternative or preliminary approach to pump testing each layer of a multilayer aquifer system separately using straddle packers or screened wells and requires no prior knowledge of permeable layer depths and thicknesses. The modification described here, of using tracer dilution rather than flowmeter logging to obtain well flow velocities, allows the approach to be extended to greater well separations, thus characterizing a larger volume of the aquifer. An example of the application of this approach to a multilayer Chalk Aquifer in Yorkshire, Northeast England, is presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏