首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The Signature of Sea Spray in the Hexos Turbulent Heat Flux Data   总被引:7,自引:0,他引:7  
The role of sea spray intransferring heat and moisture across the air-sea interface has remained elusive. Some studies have reported that sea spray does not affect the turbulent air-sea heat fluxes for 10-m wind speeds up to at least 25 m s-1, while others have reported important spray contributions for wind speeds as low as 12 m s-1. One goal of the HEXOS (Humidity Exchange over the Sea) program was to quantify spray's contribution to the turbulent air-sea heat fluxes, but original analyses of the HEXOS flux data found the spray signal to be too small to be reliably identified amid the scatter in the data. We look at the HEXOS data again in the context of the TOGA-COARE bulk flux algorithm and a sophisticated microphysical spray model. This combination of quality data andstate-of-the-art modelling reveals a distinct spray signature in virtually all HEXOS turbulent heat flux data collected in winds of 15 m s-1 and higher. Spray effects are most evident in the latent heat flux data, where spray contributes roughly 10% of the total turbulent flux in winds of 10 m s-1 and between 10 and 40% in winds of 15–18 m s-1. The spray contribution to the total sensible heat flux is also at least 10% in winds above 15 m s-1. These results lead to a new, unified parameterization for the turbulent air-sea heat fluxes that should be especially useful in high winds because it acknowledges both the interfacial and spray routes by which the sea exchanges heat and moisture with the atmosphere.  相似文献   

2.
Eddy-correlation measurements of the vertical fluxes of ozone, carbon dioxide, fine particles with diameter near 0.1 m, and particulate sulfur, as well as of momentum, heat and water vapor, have been taken above a tall leafless deciduous forest in wintertime. During the experimental period of one week, ozone deposition velocities varied from about 0.1 cm s–1 at night to more than 0.4 cm s-1 during the daytime, with the largest variations associated primarily with changes in solar irradiation. Most of the ozone removal took place in the upper canopy. Carbon dioxide fluxes were directed upward due to respiration and exhibited a strong dependence on air temperature and solar heating. The fluxes were approximately zero at air temperatures less than 5 °C and approached 0.8 mg m–2 s–1 when temperatures exceeded 15 °C during the daytime. Fine-particle deposition rates were large at times, with deposition velocities near 0.8 cm s–1 when turbulence levels were high, but fluxes directed upward were found above the canopy when the surface beneath was covered with snow. Diffusional processes seemed to dominate fine-particle transfer across quasilaminar layers and subsequent deposition to the upper canopy. Deposition velocities for particulate sulfur were highly variable and averaged to a value small in magnitude as compared to similar measurements taken previously over a pine forest in summer.  相似文献   

3.
Summary Strong stable layers are a common occurrence during western Colorado's winter. Analysis of radiosonde observations indicate wintertime boundary layer heights are near 500 m. The terrain in this region consists of mountains that rise approximately 1500–2000 m above the ground to the east, providing an effective blocking barrier. An experiment is described to observe upwelling and downwelling, longwave and shortwave radiative fluxes at two sites in western Colorado during January and February 1992, for combinations of clear, cloudy, snow covered, and bare ground periods. Analysis of the observations and the surface energy budget for typical Bowen ratios provides a better understanding of the role of radiation in maintaining and destroying stable layers.During the day, the surface received a net gain of energy from radiation, while at night there was a net loss. Over snow, the 24-hour net radiative flux was small and either positive or negative. Over bare soil, the 24-hour net radiative flux was positive but still small. There is little difference in the net radiative flux between clear and cloudy days; the reduction of the incident solar flux by clouds is nearly compensated by the hindering of the longwave cooling. The cumulative effects of the 24-hour net radiative flux were negative over snow early in the experiment. The 24-hour values shifted to near zero as the snow albedo decreased and were positive for bare ground.If the daytime net radiative flux is partitioned into sensible and latent heat flux using typical Bowen ratios, the daytime sensible heat available for destroying boundary layers is small for the low solar angles of the winter season. With a Bowen ratio of 0.5, the daytime sensible heat flux available is only 0.3 to 1.2 MJ m–2 over a snow surface and 1.4 to 2.3 MJ m–2 over soil. These heat fluxes will not build a deep enough boundary layer to break a typical wintertime inversion. The 24-hour sensible heat flux was negative at both sites for the entire experiment with this Bowen ratio.The radiation observations and the use of typical Bowen ratios lead to the conclusion that the net radiation will sustain or strengthen a stable atmosphere in the winter season in western Colorado. Analysis of the radiosonde observations confirm this result as the boundary layer depths were less than 500 m early in the experiment and grew to only 700 m later in the experiment.With 12 Figures  相似文献   

4.
The boundary layer in the warm sector of a moderately deepening winter cyclone during the Experiment on Rapidly Intensifying Cyclones over the Atlantic (ERICA) is studied near the cold front. Data from the National Center for Atmospheric Research Electra research aircraft are used to examine mean and turbulence quantities. The aircraft data and supplemental data from ships, drifting buoys and moored buoys reveal an equivalent-barotropic pressure field. The area is found to be dominated by gradients in temperature and in turbulent fluxes, with changes occurring over 100 km horizontally being comparable to changes over 350 m vertically. The horizontal components of the gradients are found to be a maximum in a direction perpendicular to the front. Cross-sections perpendicular to the front are used to illustrate boundary-layer structure. Profiles of wind speed, stress, wind direction and stress direction are estimated from an Ekman model that is modified to take into account the equivalent-barotropic pressure field. Comparison of profiles from the model to the aircraft-measured data show reasonable agreement far from the front (100 km) when the model uses a constant eddy viscosity of approximately 6 kg m–1 s–1. Near the front there is less agreement with the model. Profiles of turbulent fluxes of momentum, heat and latent heat are divergent, with along-wind momentum flux negative and decreasing upward, cross-wind momentum flux positive and increasing upward, and heat flux and latent heat flux small, positive and decreasing upward. Far from the front, the turbulent kinetic energy budget shows that dissipation balances shear production. However, near-front behavior has an imbalance at low altitude, with shear production appearing as a TKE sink.  相似文献   

5.
Eddy correlation equipment was used to measure mass and energy fluxes over a soybean crop. A rapid response CO2 sensor, a drag anemometer, a Lyman-alpha hygrometer and a fine wire thermocouple were used to sense the fluctuating quantities.Diurnal fluxes of sensible heat, latent heat and CO2 were calculated from these data. Energy budget closure was obtained by summing the sensible and latent heat fluxes determined by eddy correlation which balanced the sum of net radiation and soil heat flux. Peak daytime CO2 fluxes were near 1.0 mg m–2 (ground area) s–1.The eddy correlation technique was also employed in this study to measure nocturnal CO2 fluxes caused by respiration from plants, soil, and roots. These CO2 fluxes ranged from - 0.1 to - 0.25 mg m–2s–1.From the data collected over mature soybeans, a relationship between CO2 flux and photosynthetically active radiation (PAR) was developed. The crop did not appear to be light-saturated at PAR flux densities < 1800 Ei m–2 s–1. The light compensation point was found to be about 160 Ei m–2 s–1.Published as Paper No. 7402, Journal Series, Nebraska Agricultural Experiment Station. The work reported here was conducted under Nebraska Agricultural Experiment Station Project 27-003 and Regional Research Project 11–33.Post-doctoral Research Associate, Professor and Professor, respectively. Center for Agricultural Meteorology and Climatology, Institute of Agriculture and Natural Resources, University of Nebraska, Lincoln, NE 68583-0728.  相似文献   

6.
Atmospheric surface layer meteorological observations obtained from 20-m-high meteorological tower at Mangalore, situated along the west coast of India are used to estimate the surface layer scaling parameters of roughness length (z o) and drag coefficient (C D), surface layer fluxes of sensible heat and momentum. These parameters are computed using the simple flux–profile relationships under the framework of Monin–Obukhov (M–O) similarity theory. The estimated values of z o are higher (1.35–1.54 m) than the values reported in the literature (>0.4–0.9 m) probably due to the undulating topography surrounding the location. The magnitude of C D is high for low wind speed (<1.5 m s?1) and found to be in the range 0.005–0.03. The variations of sensible heat fluxes (SHF) and momentum fluxes are also discussed. Relatively high fluxes of heat and momentum are observed during typical days on 26–27 February 2004 and 10–11 April 2004 due to the daytime unstable atmospheric conditions. Stable or near neutral conditions prevail after 1700 h IST with negative SHF. A mesoscale model PSU/NCAR MM5 is run using a high-resolution (1 km) grid over the study region to examine the influence of complex topography on the surface layer parameters and the simulated fluxes are compared with estimated values. Spatial variations of the frictional velocity (u *), C D, surface fluxes, planetary boundary layer (PBL) height and surface winds are noticed according to the topographic variations in the simulation.  相似文献   

7.
An observational study of wind-induced waving of plants   总被引:1,自引:0,他引:1  
The motions of individual plants and the turbulence statistics of surface winds measured near the top of a canopy are obtained over a wheat field and a rush field. Two typical cases of motions of individual plants are presented. The displacements of the ear of wheat (the plant height is 1.0 m) showed a natural oscillation in wind speeds of 1.6 m s–1 measured at a height of 30 cm over a wheat canopy, while displacements of the stem of a rush plant were closely related to the fluctuations of surface winds in wind speeds of 1.7 m s–1 measured at the top of the rush plant. The power spectra of displacements of a rush plant seem to support the negative seven-third power hypothesis proposed by Inoue. The frequency responses of displacements of plants to fluctuations of the instantaneous momentum flux are also presented.  相似文献   

8.
On the cool skin of the ocean   总被引:1,自引:0,他引:1  
Previous data relating sea-surface temperature to heat flux across the air-sea interface were reanalyzed with a common formula for the wind-stress coefficient. An expression is proposed for the nondimensional thickness of the thermal sublayer: the expression increases with wind velocity at light winds and has a value of 7 when the wind velocity reaches 7 m s–1.  相似文献   

9.
Summary The Bowen ratio-energy balance (BREB) and the stability-corrected aerodynamic method were used to estimate turbulent fluxes of sensible and latent heat at an irrigated alfalfa site in a semi-arid valley in northern Utah, U.S.A., during August and September of 1991. Despite inclusion of a generalized stability factor, the aerodynamic method underestimated the daytime (sunrise-sunset) sensible and latent heat fluxes by approximately 30% in comparison with the BREB method. The sum of the aerodynamic estimates of sensible and latent heat seldom balanced the energy avaiable from net radiation and change in storage. Wind speed was low during the experiment (averaging 1.6 m s–1), and so a second analysis was run for data from daytime, non-rainy, turbulent conditions (wind > 1.5 m s–1). This showed that sensible and latent heat were still underestimated by approximately 30% in comparison with the BREB approach. This suggests that underestimation of sensible and latent heat fluxes by the aerodynamic method was not related to the wind speed conditions during the experiment. These results show that the stability-corrected aerodynamic model did not agree with the Bowen ratio method in this experiment. It appears unlikely that the discrepancies resulted from measurement errors. Perhaps the theoretical foundation of the similarity parameters (stability functions) in the aerodynamic model are not sufficiently generalized. The discrepancies found here confirm the necessity of calibration checks on the validity of aerodynamic estimates of the turbulent fluxes.With 7 Figures  相似文献   

10.
Based on measurements at Sodankylä Meteorological Observatory the regional (aggregated) momentum and sensible heat fluxes are estimated for two days over a site in Finnish Lapland during late winter. The forest covers 49% of the area. The study shows that the forest dominates and controls the regional fluxes of momentum and sensible heat in different ways. The regional momentum flux is found to be 10–20% smaller than the measured momentum flux over the forest, and the regional sensible heat flux is estimated to be 30–50% of the values measured over a coniferous forest.The regional momentum flux is determined in two ways, both based on blending height theory. One is a parameterised method, the other represents a numerical solution of an aggregation model. The regional sensible heat flux is determined from the theory of mixed-layer growth. At near neutral conditions the regional momentum flux can be determined independently of the regional sensible heat flux. At unstable conditions the two models become coupled.The information that is needed by the parameterised blending height method and by the mixed-layer evolution method in order to derive the regional fluxes of momentum and sensible heat can be obtained from radiosonde profiles of wind speed and temperature.  相似文献   

11.
Three aircraft-based studies of boundary-layer fronts (BLFs) werecarried out during the experiment KABEG in April 1997near the sea-ice edge over the Davis Strait. The zone of strongestcross-front horizontal gradients showed a typical length scaleof 20 km, while the along-front scale was observed to beseveral hundreds of kilometres.The observed BLFs were stronger than the few previously reportedcases. Horizontal gradients of potential temperature and specifichumidity ranged up to 3 K or 0.25 g kg-1over 20 km, respectively.Low-level winds were around 15 m s-1 parallel to the ice edge.The capping inversion sloped from between250 and 400 m over sea ice to between 400 and 700 m over ocean.For two BLF cases turbulent fluxes and energy budgets are calculated.Turbulent energy fluxes show a factor 2 to 3 contrast acrossthe ice edge and range from 15 to 50 W m-2 over sea iceand from 50 to 100 W m-1 over open ocean.The mean boundary-layer energy budgets are dominated bycold, dry horizontal advection, which is exceededby vertical heat flux convergence.The momentum budgets are dominated by pressure gradient force,Coriolis force and momentum flux divergence.  相似文献   

12.
13.
Dry-bulb temperature, dew-point, wind speed, and wind direction were measured in and around an isolated vegetative canopy in Davis CA from 12 to 25 October 1986. These meteorological variables were measured 1.5 m above ground along a transect of 7 weather stations set up across the canopy and the upwind/downwind open fields. These variables were averaged every 15 minutes for a period of two weeks so we could analyze their diurnal cycles as well as their spatial variability. The results indicate significant nocturnal heat islands and daytime oases within the vegetation stand, especially in clear weather. Inside the canopy within 5 m of its upwind edge, daytime temperature fell by as much as 4.5 °C, whereas the nighttime temperature rose by 1 °C. Deeper into the canopy and downwind, the daytime drop in temperature reached 6 °C, and the nighttime increase reached 2 °C. Wind speed was reduced by ~ 2 ms–1 in mild conditions and by as much as 6.7 ms–1 during cyclonic weather when open-field wind speed was in the neighborhood of 8 ms–1. Data from this project were used to construct correlations between temperature and wind speed within the canopy and their corresponding ambient, open-field values.With 10 Figures  相似文献   

14.
An experimental study of sulfur and NOx fluxes over grassland   总被引:1,自引:0,他引:1  
Three independent sulfur sensors were used in a study of sulfur eddy fluxes to a field of wheat stubble and mixed grasses, conducted in Southern Ohio in September, 1979. Two of these sensors were modified commercial instruments; one operated with a prefilter to measure gaseous sulfur compounds and the other with a denuder system to provide submicron particulate sulfur data. The third sensor was a prototype system, used to measure total sulfur fluxes. The data obtained indicated that the deposition velocity for gaseous sulfur almost always exceeded that for particulate sulfur; average surface conductances were about 1.0 cm s–1 for gaseous sulfur in the daytime and about 0.4 cm s–1 for particulate sulfur. The data indicate that nighttime values were probably much lower. The total sulfur sensor provided support for these conclusions. The boundary-layer quantity ln(z 0 /z H )was found to be 2.75 ± 0.55, in close agreement with expectations and thus providing some assurance that the site was adequate for eddy flux studies. However, fluxes derived using a prototype NOx sensor were widely scattered, partially as a consequence of sensor noise but also possibly because of the effects of nearby sources of natural nitrogen compounds.Formerly with Argonne National Laboratory.  相似文献   

15.
Vertical heat and momentum fluxes were measured by the eddy correlation method under near-neutral conditions during both day and night above a spruce forest canopy. Results show that 50% of the heat transported to the spruce canopy during night and away from the canopy during the day occurs in extreme magnitude events, the majority of less than one second duration. Extreme-magnitude events were more frequent and lasted longer during the day than during the night. The distributions of the duration of extreme events in the same direction as the net heat flux and the turbulence intensity for both day and night were similar.During the night, the mean horizontal windspeed was about 1 m s-1 and the measured coincident transport of momentum and heat accounted for 36% of the total heat flux. The predominant mechanism of forced convection during the extreme nightime heat transport events was excess heat sweeps in which the duration of the event is usually less than 1 s. During the day, the mean horizontal windspeed was about 2 m s -1 and the measured coincident transport of momentum and heat accounted for only 16% of the total heat flux. Local free convection was suggested to account for 27% of the total heat flux. The predominant mechanism of mixed convection during the extreme daytime heat transport events is deficit heat inward interactions. During both night and day, about 10% of the total heat transport occurred in extreme events working against the thermal gradient.Now atPurdue University, West Lafayette, IN, U.S.A.  相似文献   

16.
An experimental micrometeorological set-up was established at the CARBOEURO-FLUX site in Tharandt, Germany, to measure all relevant variables for the calculation of the vertical and horizontal advective fluxes of carbon dioxide. The set-up includes two auxiliary towers to measure horizontal and vertical CO2 and H2O gradients through the canopy, and to make ultrasonic wind measurements in the trunk space. In combination with the long-term flux tower an approximately even-sided prism with a typical side-length of 50 m was established. It is shown that under stable (nighttime) conditions the mean advective fluxes have magnitudes on the same order as the daily eddy covariance (EC) flux, which implies that they play a significant, but not yet fully understood, role in the carbon budget equation. The two advective fluxes are opposite and seem to cancel each other at night (at least for these measurements). During the day, vertical advection tends to zero, while horizontal advection is still present implying a flow of CO2 out of the control volume. From our measurements, a mean daily gain of 2.2 gC m–2 d–1 for the horizontal advection and a mean daily loss of 2.5 gC m–2d–1 for the vertical advection is calculated for a period of 20 days. However the large scatter of the advective fluxes has to be further investigated. It is not clear yet whether the large variability is natural or due to measurement errors and conceptual deficiencies of the experiment. Similar results are found in the few comparable studies.  相似文献   

17.
Concurrent measurements of the surface energy balance components (net radiation, heat storage, and sensible and latent heat fluxes) were made in three communities (open water, Phragmites australis, Scirpus acutus) in a wetland in north-central Nebraska, U.S.A., during May-October, 1994. The Bowen ratio – energy balance method was used to calculate latent and sensible heat fluxes. This paper presents results from the open water area. The heat stored in water (G) was found to play a major role in the energy exchange over the water surface. During daytime, G consumed 45–60% of R n , the net radiation (seasonally averaged daytime G was about 127 W m–2). At night, G was a significant source of energy (seasonally averaged nighttime G was about -135 Wm). The diurnal pattern of latent heat flux ( E) did not follow that of R n . On some days, E was near zero during midday periods with large R n . The diurnal variability in E seemed to be significantly affected by temperature inversions formed over the cool water surface. The daily evaporation rate (E) ranged from 2 to 8 mm during the measurement period, and was generally between 70 and 135% of the equilibrium rate.  相似文献   

18.
中国西北干旱区戈壁下垫面夏季的热力输送   总被引:5,自引:1,他引:5  
以敦煌戈壁站2004年6月和2008年8月的常规观测和超声观测为例,分析了西北干旱区戈壁下垫面夏季热力输送的一般过程及特征。首先评价了湍流通量的观测质量以及仪器观测的地表能量通量闭合问题,结果表明敦煌戈壁站的观测在白天总体较好。夏季地表能量通量的平均日变化显示,潜热通量整天都很小,可以忽略,白天到达地表的短波辐射以及地表向上的长波辐射非常强,地表净辐射主要转化为感热输送(敦煌戈壁站在中午时平均分别达380W·m-2以上和250W·m-2以上);夜间土壤释放热量以平衡地表的辐射冷却,感热通量略低于0。白天时地表大气经常触发自由对流活动,影响动量通量的观测质量,并有效输送地表热力至上层大气中,有助于形成超厚大气边界层。分析了戈壁下垫面的动量粗糙度特征和热力粗糙度特征(敦煌戈壁站动量粗糙度约为0.6mm),热力粗糙度基本小于动量粗糙度一个量级,这符合目前对干旱区戈壁下垫面热力输送特征的初步认识。  相似文献   

19.
The vegetated urban canopy model (VUCM), which includes parametrizations of urban physical processes for artificial surfaces and vegetated areas in an integrated system, has been further developed by including physical processes associated with grass-covered surfaces in urban pervious surfaces and the photosynthesis effects of urban vegetation. Using measurements made from three urban/suburban sites during the BUBBLE field campaign in 2002, the model’s performance in modelling surface fluxes (momentum flux, net radiation, sensible and latent heat fluxes and storage heat flux) and canopy air conditions (canopy air temperature and specific humidity) was critically evaluated for the non-precipitation and the precipitation days. The observed surface fluxes at the urban/suburban sites were significantly altered by precipitation as well as urban vegetation. Especially, the storage heat at urban surfaces and underlying substrates varied drastically depending on weather conditions while having an important role in the formation of a nocturnal urban surface layer. Unlike the nighttime canopy air temperature that was largely affected by the storage-heat release, the daytime canopy air conditions were highly influenced by the vertical turbulent exchange with the overlying atmosphere. The VUCM well reproduced these observed features in surface fluxes and canopy air conditions at all sites while performing well for both the non-precipitation and the precipitation days. The newly implemented parametrizations clearly improved the model’s performance in the simulation of sensible and latent heat fluxes at the sites, more noticeably at the suburban site where the vegetated area fraction is the largest among the sites. Sensitivity analyses for model input parameters in VUCM elucidated the relative importance of the morphological, aerodynamic, hydrological and radiative/thermal properties in modelling urban surface fluxes and canopy air conditions for daytime and nighttime periods. These results suggest that the VUCM has great potential for urban atmospheric numerical modelling for a range of cities and weather conditions in addition to having a better physical basis in the representation of urban vegetated areas and associated physical processes.  相似文献   

20.
The spatial variability and temporal behavior of the vertical flux of ozone have been investigated from turbulence measurements collected on aircraft flight legs in the daytime period during two consecutive summer experimental field programs. The data were obtained during horizontal flight legs conducted over agricultural crops and forested land in three different regions of the eastern United States.Results from individual experimental cases and statistics derived from all cases in each region are presented. Ozone flux generally exhibited a significant height dependency. The strongest negative (downward) fluxes in the lowest-level flight legs were primarily attributed to the uptake of ozone by the surface and vegetative cover. Fluxes were near-zero in the middle of the convective boundary layer (CBL) in the afternoon period. As ozone flux was proportional to concentration, slightly stronger fluxes were found in low-level urban plume segments where ozone concentrations were 10–20 ppb higher than in the surrounding area. The derived deposition velocity showed no such bias as a function of position across the urban plume. Ozone flux differences were not apparent between the more heavily forested sections and the primarily agricultural cropland areas in these regions. During the afternoon period when no clear temporal trend was evident, means from values obtained below 0.15Z i (Z i being the CBL height) were -0.421 and -0.431 ppb m-2 s-1 for ozone flux and 0.81 and 0.82 cm s-1 for the derived mean deposition velocity in the southeastern Pennsylvania and central Ohio areas, respectively. These experimental results for ozone provide support to a dry deposition parameterization module which computes grid-area averaged deposition velocities for use in regional-scale models.On assignment from the National Oceanic and Atmospheric Administration, U.S. Department of Commerce.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号