首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The study underlines the characteristics of the urban heat island of Ia?i (Ia?i’s UHI) on the basis of 3 years of air temperature measurements obtained by fixed-point observations. We focus on the identification of UHI development and intensity as it is expressed by the temperature differences between the city centre and the rural surroundings. Annual, seasonal and daily characteristics of Ia?i’s UHI are investigated at the level of the classical weather observation. In brief, an intensity of 0.8 °C of UHI and a spatial extension which corresponds to the densely built area of the city were delineated. The Ia?i UHI is stronger during summer calm nights—when the inner city is warmer with 2.5–3 °C than the surroundings—and is weaker during windy spring days. The specific features of Ia?i’s UHI bear a profound connection to the specificity of the urban structure, the high atmospheric stability in the region and the local topography. Also, the effects of Ia?i’s UHI upon some environmental aspects are presented as study cases. For instance, under the direct influence of UHI, we have observed that in the city centre, the apricot tree blossoms earlier (with up to 4 days) and the depth of the snow cover is significantly lower (with up to 10 cm for a rural snow depth of 30 cm) than in the surrounding areas.  相似文献   

2.
Urban surface modeling and the meso-scale impact of cities   总被引:4,自引:0,他引:4  
Summary New developments of the international community in modeling the urban canopy surface energy balance are presented and classified into five main categories: (i) models statistically fit to observations, (ii) and (iii) modified vegetation schemes with or without drag terms in the canopy, and (iv) and (v), new urban canopy schemes, that present both horizontal and vertical surfaces, again with or without a drag approach. The advantages and disadvantages of each type of model are explained. In general, the more the physics are correctly simulated, the more complex are the urban phenomenon that can be addressed, on the other hand however, the more consuming of computer-time and difficult to couple with atmospheric models the scheme becomes. Present use of these new models in meso-scale atmospheric models show their ability to reproduce the phenomenon of the urban heat island (UHI) and some of its consequences – urban breezes, storm initiation, interaction with sea-breeze. Their use opens up new perspectives, for example in the mitigation of the UHI, or assessment of the role of air-conditioning systems or the impact of urban dynamics on air pollution. However, there is need to validate further the different urban models available. In particular it is necessary to compare model output with urban surface energy balance measurements. An intercomparison exercise involving these urban schemes is suggested as an efficient way to assess and improve these models.  相似文献   

3.
The large-eddy simulation mode of the Weather Research and Forecasting model is employed to simulate the planetary boundary-layer characteristics and mesoscale circulations forced by an ideal urban heat island (UHI). In our simulations, the horizontal heterogeneity of the UHI intensity distribution in urban areas is considered and idealized as a cosine function. Results indicate that the UHI heating rate and the UHI intensity heterogeneity affect directly the spatial distribution of the wind field; a stronger UHI intensity produces a maximum horizontal wind speed closer to the urban centre. The strong advection of warm air from the urban area to the rural area in the upper part of the planetary boundary-layer causes a more stable atmospheric stratification over both the urban and rural areas. The mesoscale sensible heat flux caused by the UHI circulation increases with UHI intensity but vanishes when the background wind speed is sufficiently high $(>$ 3.0  $\mathrm{{m\,s}}^{-1})$ .  相似文献   

4.
Urban heat island research from 1991 to 2015: a bibliometric analysis   总被引:1,自引:0,他引:1  
A bibliometric analysis based on the Science Citation Index-Expanded (SCI-Expanded) database from the Web of Science was performed to review urban heat island (UHI) research from 1991 to 2015 and statistically assess its developments, trends, and directions. In total, 1822 papers published in 352 journals over the past 25 years were analyzed for scientific output; citations; subject categories; major journals; outstanding keywords; and leading countries, institutions, authors, and research collaborations. The number of UHI-related publications has continuously increased since 1991. Meteorology atmospheric sciences, environmental sciences, and construction building technology were the three most frequent subject categories. Building and Environment, International Journal of Climatology, and Theoretical and Applied Climatology were the three most popular publishing journals. The USA and China were the two leading countries in UHI research, contributing 49.56% of the total articles. Chinese Academy of Science, Arizona State University, and China Meteorological Administration published the most UHI articles. Weng QH and Santamouris M were the two most prolific authors. Author keywords were classified into four major groups: (1) research methods and indicators, e.g., remote sensing, field measurement, and models; (2) generation factors, e.g., impervious urban surfaces, urban geometry, waste heat, vegetation, and pollutants; (3) environmental effects, e.g., urban climate, heat wave, ecology, and pollution; and (4) mitigation and adaption strategies, e.g., roof technology cooling, reflective cooling, vegetation cooling, and urban geometry cooling. A comparative analysis of popular issues revealed that UHI determination (intensity, heat source, supporting techniques) remains the central topic, whereas UHI impacts and mitigation strategies are becoming the popular issues that will receive increasing scientific attention in the future. Modeling will continue to be the leading research method, and remote sensing will be used more widely. Additionally, a combination of remote sensing and field measurements with models is expected.  相似文献   

5.
The study has analyzed influence of an atmospheric circulation on urban heat island (UHI) and urban cold island (UCI) in Poznań. Analysis was conducted on the basis of temperature data from two measurement points situated in the city center and in the ?awica airport (reference station) and the data concerning the air circulation (Nied?wied?’s calendar of circulation types and reanalysis of National Centers for Environmental Prediction (NCEP)/National Center for Atmospheric Research (NCAR)). The cases with UHI constitute about 85 % of all data, and UCI phenomena appear with a frequency of 14 % a year. The intensity of UHI phenomenon is higher in the anticyclonic circulation types. During the year in anticyclonic circulation, intensity of UHI is 1.2 °C on average while in cyclonic is only 0.8 °C. The occurring of UHI phenomena is possible throughout all seasons of the year in all hours of the day usually in anticyclonic circulation types. The cases with highest UHI intensity are related mostly to nighttime. The cases of UCI phenomena occurred almost ever on the daytime and the most frequently in colder part of the year together with cyclonic circulation. Study based on reanalysis data indicates that days with large intensity of UHI (above 4, 5, and 6 °C) are related to anticyclonic circulation. Anticyclonic circulation is also promoting the formation of the strongest UCI. Results based on both reanalysis and the atmospheric circulation data (Nied?wied?’s circulation type) confirm that cases with the strongest UHI and UCI during the same day occur in strong high-pressure system with the center situated above Poland or central Europe.  相似文献   

6.
Urban heat island intensities (UHI) have been assessed based on in situ measurements and satellite-derived observations for the megacity Delhi during a selected period in March 2010. A network of micrometeorological observational stations was set up across the city. Site selection for stations was based on dominant land use–land cover (LULC) classification. Observed UHI intensities could be classified into high, medium and low categories which overall correlated well with the LULC categories viz. dense built-up, medium dense built-up and green/open areas, respectively. Dense urban areas and highly commercial areas were observed to have highest UHI with maximum hourly magnitude peaking up to 10.7 °C and average daily maximum UHI reaching 8.3 °C. UHI obtained in the study was also compared with satellite-derived land surface temperatures (LST). UHI based on in situ ambient temperatures and satellite-derived land surface temperatures show reasonable comparison during nighttime in terms of UHI magnitude and hotspots. However, the relation was found to be poor during daytime. Further, MODIS-derived LSTs showed overestimation during daytime and underestimation during nighttime when compared with in situ skin temperature measurements. Impact of LULC was also reflected in the difference between ambient temperature and skin temperature at the observation stations as built-up canopies reported largest gradient between air and skin temperature. Also, a comparison of intra-city spatial temperature variations based UHI vis-à-vis a reference rural site temperature-based UHI indicated that UHI can be computed with respect to the station measuring lowest temperature within the urban area in the absence of a reference station in the rural area close to the study area. Comparison with maximum and average UHI of other cities of the world revealed that UHI in Delhi is comparable to other major cities of the world such as London, Tokyo and Beijing and calls for mitigation action plans.  相似文献   

7.
城市热岛效应热点问题研究进展   总被引:1,自引:0,他引:1  
概述了国内外城市热岛效应研究热点及不足,探讨了时空替代性、评价指标合理性、模拟空间尺度适宜性及理论与应用研究相结合等问题,指出未来城市热岛效应研究应注重新方法与新思路的集成、城市群热岛效应监测、城市热岛与全球异常环境要素间的生态关联性、缓解城市热岛效应的生态途径与技术方法。  相似文献   

8.
In this study, urban climate in Nanjing of eastern China is simulated using 1-km resolution Weather Research and Forecasting (WRF) model coupled with a single-layer Urban Canopy Model. Based on the 10-summer simulation results from 2000 to 2009 we find that the WRF model is capable of capturing the high-resolution features of urban climate over Nanjing area. Although WRF underestimates the total precipitation amount, the model performs well in simulating the surface air temperature, relative humidity, and precipitation frequency and inter-annual variability. We find that extremely hot events occur most frequently in urban area, with daily maximum (minimum) temperature exceeding 36°C (28°C) in around 40% (32%) of days. Urban Heat Island (UHI) effect at surface is more evident during nighttime than daytime, with 20% of cases the UHI intensity above 2.5°C at night. However, The UHI affects the vertical structure of Planet Boundary Layer (PBL) more deeply during daytime than nighttime. Net gain for latent heat and net radiation is larger over urban than rural surface during daytime. Correspondingly, net loss of sensible heat and ground heat are larger over urban surface resulting from warmer urban skin. Because of different diurnal characteristics of urban-rural differences in the latent heat, ground heat and other energy fluxes, the near surface UHI intensity exhibits a very complex diurnal feature. UHI effect is stronger in days with less cloud or lower wind speed. Model results reveal a larger precipitation frequency over urban area, mainly contributed by the light rain events (< 10 mm d?1). Consistent with satellite dataset, around 10?C20% more precipitation occurs in urban than rural area at afternoon induced by more unstable urban PBL, which induces a strong vertical atmospheric mixing and upward moisture transport. A significant enhancement of precipitation is found in the downwind region of urban in our simulations in the afternoon.  相似文献   

9.
This paper studies the maximum intensity of the urban heat island (UHI) that develops in Volos urban area, a medium-sized coastal city in central Greece. The maximum temperature difference between the city center and a suburb is 3.4°C and 3.1°C during winter and summer, respectively, while during both seasons the average maximum UHI intensity is 2.0°C. The UHI usually starts developing after sunset during both seasons. It could be attributed to the different nocturnal radiative cooling rate and to the different anthropogenic heat emission rate that are observed at the city center and at the suburb, as well as to meteorological conditions. The analysis reveals that during both seasons the daily maximum hourly (DMH) UHI intensity is positively correlated with solar radiation and with previous day’s maximum hourly UHI intensity and negatively correlated with wind speed. It is also negatively correlated with relative humidity during winter but positively correlated with it during summer. This difference could be attributed to the different mechanisms that mainly drive humidity levels (i.e., evaporation in winter and sea breeze (SB) in summer). Moreover, it is found that SB development triggers a delay in UHI formation in summer. The impact of atmospheric pollution on maximum UHI intensity is also examined. An increase in PM10 concentration is associated with an increase in maximum UHI intensity during winter and with a decrease during summer. The impact of PM10 on UHI is caused by the attenuation of the incoming and the outgoing radiation. Additionally, this study shows that the weekly cycle of the city activities induces a weekly variation in maximum UHI intensity levels. The weekly range of DMH UHI intensity is not very large, being more pronounced during winter (0.4°C). Moreover, a first attempt is made to predict the DMH UHI intensity by applying regression models, whose success is rather promising.  相似文献   

10.
The urban heat island of a city in an arid zone: the case of Eilat, Israel   总被引:1,自引:0,他引:1  
Summary This study presents the results of a preliminary research that was conducted in the city of Eilat, located in an extreme hot and arid zone on the northern coast of the Red Sea. The purpose was to analyse the characteristics of the local urban heat island (UHI). Diurnal pre-dawn and early-afternoon measurements were taken in winter and summer weather conditions on three separate occasions for two consecutive years. The results show the development of a moderate UHI located around the most intensive area of human activity; the city business centre and dense hotel belt. The UHI is more significant at midday during the summer period, while early morning inversions in winter have a weakening effect on the UHI intensity. It was found that the topography and wind regime have a dominant effect on the location and intensity of the UHI, while the sea has a very marginal effect. Due to the UHI influences on the spatial distribution of the heat stress in the city, it is suggested that further applied UHI research should be focused on the summer period.  相似文献   

11.
In this study, the urban heat island of Toronto was characterized and estimated in order to examine the impact of the selection of rural sites on the estimation of urban heat island (UHI) intensity (?T u-r). Three rural stations, King Smoke Tree (KST), Albion Hill, and Millgrove, were used for the analysis of UHI intensity for two urban stations, Toronto downtown (Toronto) and Toronto Pearson (Pearson) using data from 1970 to 2000. The UHI intensity was characterized as winter dominating and summer dominating, depending on the choice of the rural station. The analyses of annual and seasonal trends of ?T u-r suggested that urban heat island clearly appears in winter at both Toronto and Pearson. However, due to the mitigating effect on temperature from Lake Ontario, the estimated trend of UHI intensity was found to be less at Toronto compared to that at Pearson which has no direct lake effect. In terms of the impacts of the rural stations, for both KST and Millgrove, the trends in UHI intensity were found to be statistically significant and also were in good agreement with the estimates of UHI intensities reported for other large cities in the USA. Depending on the choice of the rural station, the estimated trend for the UHI intensity at Toronto ranges from 0.01°C/decade to 0.02°C/decade, and that at Pearson ranges from 0.03°C/decade to 0.035°C/decade during 1970–2000. From the analysis of the seasonal distribution of ?T u-r, the UHI intensity was found to be higher at Toronto in winter than that at Pearson for all three rural stations. This was likely accounted for by the lower amount of anthropogenic heat flux at Pearson. Considering the results from the statistical analysis with respect to the geographic and surface features for each rural station, KST was suggested to be a better choice to estimate UHI intensity at Toronto compared to the other rural stations. The analysis from the current study suggests that the selection of a unique urban–rural pair to estimate UHI intensity for a city like Toronto is a critical task, as it will be for any city, and it is imperative to consider some key features such as the physiography, surface characteristics of the urban and rural stations, the climatology such as the trends in annual and seasonal variation of UHI with respect to the physical characteristics of the stations, and also more importantly the objectives of a particular study in the context of UHI effect.  相似文献   

12.
This study analyses the atmospheric boundary layer over the Bilbao metropolitan area during summer (13–18 Jul 2009) and winter (20–29 Jan 2010) episodes using the Environment–High Resolution Limited Area Model (Enviro-HIRLAM) coupled with the building effect parameterisation (BEP). The main objectives of this study are: to evaluate the performance of the model to simulate the land–sea breezes over this complex terrain; to assess the simulations with the integration of an urban parameterisation in Enviro-HIRLAM and finally; and to analyse the urban–atmosphere interactions. Even if the hydrostraticity of the model is a limitation to simulate atmospheric flows over complex terrain, sensibility tests demonstrate that 2.4 km is the optimal horizontal resolution over Bilbao that allows at the same time: to obtain satisfactory reproducibility of the large-scale processes and to explore the urban effects at local scale. During the summer episode, a typical regime of diurnal sea breeze from the NW-N-NE direction and nocturnal valley breezes from the SE direction are observed over Bilbao. The urban heat island (UHI) phenomenon is developed in the city centre expanding to the suburbs from 22 to 10 local time (LT), covering an area of 130 km2. The maximum UHI intensity, 1 °C, is reached at the end of the night (5 LT), and it is advected 12 km towards the sea by the land breezes. The urban boundary layer (UBL) height amplitude varies from 100 (night time) to 1,360 m (at 14 LT). During the winter episode, the land breeze dominates the atmospheric diffusion during the day and night time. The maximum UHI intensity, 1.7 °C, is observed at 01 LT. It is spread and remained over the city covering an area of 160 km2, with a vertical extension of 33 m. The UBL reaches 780 m height at 16 LT the following day.  相似文献   

13.
Summary This paper examines the characteristics of the morning Urban Heat Island (UHI) in Athens basin, Greece. The study is performed by using and analyzing mesoscale and synoptic data covering the period 1990–2001. The UHI was estimated using the 0600 Local Time (LT) minimum temperature differences between rural and urban areas of the city. The analysis results in 7 UHI classes. A strong UHI was found for the 1/3 of days. The specific meteorological characteristics (surface and upper air, cooling rate) of each UHI class were revealed and examined. The spatial and temporal characteristics of the UHI were also identified. The UHI is largest on nights with clear skies and low relative humidity. In all seasons the UHI switches on rapidly in afternoon. During spring and summer, sea breeze commonly reduces and delays the UHI. Cases documenting the sensitivity and rapidity of changes of the UHI to changes in classes (cloud cover, wind) are also presented. The cooling rate is higher in the urban area under negative and lower under positive UHI conditions. Mesoscale and macroscale phenomena were examined during the different UHI classes through a weather type scheme. It was emerged that high UHI classes are associated with anticyclonic conditions or advection in the lower troposphere, while low UHI classes are associated with strong northeasterly winds. Anticyclonic conditions which frequently occur in spring and early summer, reduce or reverse the UHI to Urban Cooling Island.  相似文献   

14.
The statistical and dynamical characteristics of the urban heat island (UHI) intensity in Seoul are investigated for non-precipitation days and precipitation days using 4-year surface meteorological data with 1-h time intervals. Furthermore, the quantitative influence of synoptic pressure pattern on the UHI intensity is examined using a synoptic condition clustering method. The statistical analysis shows that the daily maximum UHI intensity in Seoul for non-precipitation days is strongest in autumn (4.8°C) and weakest in summer (3.5°C). The daily maximum UHI intensity is observed around midnight in all seasons except in winter when the maximum occurrence frequency is found around 08 LST. This implies that anthropogenic heating contributes to the UHI in the cold season. The occurrence frequency of the UHI intensity has a negatively skewed distribution for non-precipitation days but a positively skewed distribution for precipitation days. The amplitude of the heating/cooling rate and the difference in the heating/cooling rate between the urban and rural areas are smaller in all seasons for precipitation days than for non-precipitation days, resulting in weaker UHI intensities for precipitation days. The urban cool island occurs very often in the daytime, with an occurrence frequency being 77% of the total non-precipitation days in spring. The analysis of the impact of large-scale dynamical forcing shows that the daily maximum UHI intensity varies with synoptic pressure pattern, ranging from ?22% in spring to 28% in summer relative to the seasonal mean daily maximum UHI intensity. Comparison of the UHI intensity calculated using station-averaged temperatures to that based on the conventional two-station approach indicates that local effects on the UHI intensity are minimized by using multiple-station data. Accordingly, an estimation of the UHI intensity using station-averaged temperatures for both urban and rural areas is suggested.  相似文献   

15.
北京夏季强热岛分析及数值模拟研究   总被引:5,自引:1,他引:5  
李兴荣  胡非  舒文军 《气象》2007,33(6):25-31
应用北京地区20个常规地面气象站、2个自动气象站和中国科学院大气物理研究所325m气象铁塔的资料,对北京2003年7月热岛状况进行了统计分析,发现北京夏季夜间存在强热岛效应,夏季夜间存在强热岛效应的天数占到了1/3,强弱热岛天数合计占到了大约4/5。进一步分析7月1日强热岛特征及其气象影响因子,结果表明:夜间存在强热岛时,郊区所有测站的地面气温都要低于主城区地面气温,城市强热岛的高温中心在天安门和白家庄连线的主城区;白天日照充足的晴夜,日落后城区320m以下低层大气存在逆温和弱的风速,城区地面气温下降速率和幅度均远小于郊区,城市强热岛因此得以形成和维持。日出后至正午,北京北部郊区日照时间比城区长,郊区地面大气得到来自太阳辐射的能量多于城区,而太阳辐射的加热作用使城区低层大气逆温消失,大气稳定度减弱,并使郊区地面气温上升速率和幅度大于城区,最终导致夜间出现的强热岛减弱、消失。此外,应用MM5模式对强热岛进行了初步数值模拟研究,发现在MM5中考虑城市人为热和热储存,可以改善模式对热岛的数值模拟,表明城市人为热和热储存在夏季强热岛的形成中有重要作用。  相似文献   

16.
Summary ¶This study examines the spatial and quantitative influence of urban factors on the surface air temperature field of the medium-sized of Szeged, Hungary, using mobile measurements under different weather conditions in the periods of March 1999–February 2000 and April–October 2002. Efforts have been concentrated on the development of the urban heat island (UHI) in its peak development during the diurnal cycle. Tasks included: (1) determination of spatial distribution of mean maximum UHI intensity and some urban surface parameters (built-up and water surface ratios, sky view factor, building height) using the standard Kriging procedure, as well as (2) development of a statistical model in the so-called heating and non-heating seasons using the above mentioned parameters and their areal extensions. In both seasons the spatial distribution of the mean maximum UHI intensity fields had a concentric shape with some local irregularities. The intensity reaches more than 2.1°C (heating season) and 3.1°C (non-heating season) in the centre of the city. For both seasons statistical model equations were determined by means of stepwise multiple linear regression analysis. As the measured and calculated mean maximum UHI intensity patterns show, there is a clear connection between the spatial distribution of the urban thermal excess and the examined land-use parameters, so these parameters play an important role in the evolution of the strong UHI intensity field. From the above mentioned parameters the sky-view factor and the building height were the most determining factors which are in line with the urban surface energy balance. Therefore in the future, using our model it will be possible to predict mean maximum UHI intensity in other cities, which have land-use features similar to Szeged.Received September 26, 2002; revised February 25, 2003; accepted March 22, 2003 Published online July 30, 2003  相似文献   

17.
Temporal characteristics of the Beijing urban heat island   总被引:4,自引:0,他引:4  
Summary This paper describes the inter-annual trend, and the seasonal and hourly variation of the near surface urban heat island (UHI) in Beijing. The surface air temperature data (mean, maximum, and minimum) from one urban (downtown Beijing) and one rural (70 km from downtown Beijing) station were used for the period 1977 and 2000. It is found that the temperatures in both urban and rural stations show an increasing tendency. Specifically, minimum temperature shows the greatest tendency at the urban station whereas maximum temperature shows the greatest increase at the rural station. The UHI intensity obtained by calculating the difference in temperatures between the two stations identifies that the intensity is greatest and has the greatest increasing trend for minimum temperature, while the UHI intensity of maximum temperature shows a slow decrease over time. UHI intensity for minimum temperature has a strong positive correlation with the increase in the urban population and the expansion of the yearly construction area. Seasonal analyses showed the UHI intensity is strongest in winter. This seasonal UHI variation tends to be negatively correlated with the seasonal variation of relative humidity and vapor pressure. Hourly variation reveals that the strongest UHI intensity is observed in the late nighttime or evening, while the weakest is observed during the day.  相似文献   

18.
利用MODIS地表温度数据,计算城市热岛强度指数,分析近15年广州市城市热岛的时空分布特征及演变规律,并结合气象观测数据、社会统计数据定性分析其主要影响因素。结果表明:广州市城市热岛的空间分布受地形地貌影响明显,负热岛区主要分布于森林密集的北部山区,无热岛区主要分布于中部低山丘陵区域,热岛区主要分布于高度城市化的中南部平原区。关于城市热岛的日变化规律,白天热岛区、负热岛区面积均小于夜间,但白天热岛区强度、负热岛区强度大于夜间。关于城市热岛的季节变化规律,冬季热岛区面积最大,热岛强度最小,夏季热岛区面积最小,热岛强度最大;冬季负热岛区面积最小,负热岛强度最小,夏季负热岛区面积最大,负热岛强度最大。对于城市热岛的年际变化规律,近15年来广州市的热岛区、负热岛区占全市总面积的百分比呈上升趋势,无热岛区所占百分比呈下降趋势,人为热排放在城市中心区域的持续增长,加上区内建筑物密度大、植被覆盖度低,导致了热岛区的增加,而北部山区至中部丘陵山区的植被的持续好转,加上地理特征限制了该区域的城市化发展,导致了负热岛区的增加。   相似文献   

19.
利用1972-2011年阳泉市3个国家级气象站资料、2011年36个乡镇区域自动站气温资料,分析了阳泉市城市热岛效应的年际变化、季节变化、月变化和日变化特征。结果表明:阳泉市存在弱的城市热岛效应,1972-2011年平均热岛强度0.554 ℃。阳泉市城市热岛强度整体呈显著上升趋势,热岛强度的增加主要是由于夏季热岛强度的增强;热岛强度冬、秋季强,春、夏季弱;12月最强,5月最弱;热岛强度日变化表现为12时最小,从傍晚开始随降温逐渐增大,到早晨气温降到最低时最大,日出之后迅速减小;2008-2011年最强热岛强度出现在2010年1月14日08时,达7.9 ℃。阳泉在升温天气热岛强度变幅增大,易在早晨形成较强城市热岛,下午形成城市冷岛;降温天气热岛强度变幅减小;温度变化较小时则易维持弱的城市热岛。阳泉市主要城市发展因子与霾日数、气温呈显著正相关,在目前的经济发展水平条件下,阳泉市城市化发展可能使城市温度增高,城市绿地面积的增加可能对热岛效应有缓解作用。  相似文献   

20.
城市热岛效应的研究进展与展望   总被引:24,自引:1,他引:23  
寿亦萱  张大林 《气象学报》2012,70(3):338-353
随着世界各国城市化的进展,城市热岛效应已经成为一个跨学科领域的问题,受到包括大气环境、区域气候、水文和生态等多学科科学家的关注。在过去半个多世纪中,城市热岛问题的研究获得了相当丰富的研究成果,通过对这些成果的综合分析,归纳出城市热岛研究中采用的3类主要方法——观测(外场试验和遥感技术)、数值模拟以及实验室仿真法。系统地回顾了城市热岛效应的研究历史,重点对与城市热岛关系最密切的城市边界层、热岛环流与复杂地形的相互作用以及能量平衡研究所取得的成果进行了总结和评述。最后对城市热岛问题未来8个可能的研究方向进行了探讨,其中,包括沿海和复杂地形附近的城市热岛问题、城市群间热岛环流的相互作用、城市化与空气污染问题、城市热岛效应对平均降水的影响、城市化对雾和闪电的影响、城市天气预报的精细化、城市气候变化预测以及城市热岛效应减缓方案的制定,并对其发展前景进行了粗略的展望。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号