首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Abstract Drilling was carried out to penetrate the Nojima Fault where the surface rupture occurred associated with the 1995 Hyogo-ken Nanbu earthquake. Two 500 m boreholes were successfully drilled through the fault zone at a depth of 389.4 m. The drilling data show that the relative uplift of the south-east side of the Nojima Fault (south-west segment) was approximately 230 m. The Nojima branch fault, which branches from the Nojima Fault, is inferred to extend to the Asano Fault. From the structural contour map of basal unconformity of the Kobe Group, the vertical component of displacement of the Nojima branch–Asano Fault is estimated to be 260–310 m. Because the vertical component of displacement on the Nojima Fault of the north-east segment is a total of those of the Nojima Fault of the south-west segment and of the Nojima branch–Asano Fault, it is estimated to total to 490–540 m. From this, the average vertical component of the slip rate on the Nojima Fault is estimated to be 0.4–0.45 m/103 years for the past 1.2 million years.  相似文献   

2.
Abstract Seismometers were installed at three depths in the Disaster Prevention Research Institute, Kyoto University (DPRI) 1800 m borehole drilled into the Nojima Fault zone, southwest Japan. The waveforms recorded by these seismometers are rather simple compared with those recorded at the DPRI 800 m borehole or on the ground surface. These data should be well suited for detecting fault zone-trapped waves and estimating the fault zone structure and its temporal variation related to the healing process of the ruptured fault. Typical waveforms trapped in the fault zone were observed by a surface seismographic array across the Nojima Fault just after the 1995 Hyogo-ken Nanbu earthquake (Kobe earthquake). Among the wave data recorded in the DPRI 1800 m borehole, however, clear evidences of fault zone-trapped waves have not yet been found, and further studies are continuing. The present study outlines the observation system in the DPRI 1800 m borehole, which will make it easier to access and analyze the borehole data.  相似文献   

3.
Abstract In order to make geophysical and geological investigations of the Nojima Fault on Awaji Island, Japan, three boreholes measuring 1800 m, 800 m and 500 m deep were drilled into the fault zone. The fault is one of the seismic source faults of the 1995 Hyogo-ken Nanbu earthquake of M 7.2. A new multicomponent borehole instrument was installed at the bottom of the 800 m borehole and continuous observations of crustal strain and tilt have been made using this instrument since May 1996. A high-pressure water injection experiment within the 1800 m borehole was done in February and March 1997 to study the geophysical response, behavior, permeability, and other aspects of the fault zone. The injection site was located approximately 140 m horizontally and 800 m vertically from the instrument. Associated with the water injection, contraction of approximately 0.7 × 10−7 str (almost parallel to the fault) and tilt of approximately 1 × 10-7 rad in the sense of upheaval toward the injection site were observed. In addition to these controlled experiments, the strainmeter and tiltmeter also recorded daily variations. We interpret strain and tilt changes to be related to groundwater discharge and increased ultra-micro seismicity induced by the injected water.  相似文献   

4.
Abstract To better understand heat generation and transfer along earthquake faults, this paper presents preliminary zircon fission-track (FT) length data from the Nojima Fault, Awaji Island, Japan, which was activated during the 1995 Kobe earthquake (Hyogo-ken Nanbu earthquake). Samples were collected of Cretaceous granitic rocks from the Ogura 500 m borehole as well as at outcrops adjacent to the borehole site. The Nojima Fault plane was drilled at a depth of 389.4 m (borehole apparent depth). Fission-track lengths in zircons from localities > 60 m distance from the fault plane, as well as those from outcrops, are characterized by the mean values of ≈10–11 μm and unimodal distributions with positive skewness, which show no signs of an appreciable reduction in FT length. In contrast, those from nearby the fault at depths show significantly reduced mean track lengths of ≈6–8 μm and distributions having a peak around 6–7 μm with rather negative skewness. In conjunction with other geological constraints, these results are best interpreted by a recent thermal anomaly around the fault, which is attributable to heat transfer via focused fluids from the deep interior of the crust and/or heat dispersion via fluids associated with frictional heating by fault motion.  相似文献   

5.
Abstract A multi-offset hydrophone vertical seismic profiling (VSP) experiment was done in a 747 m deep borehole at Nojima Hirabayashi, Hyogo prefecture, Japan. The borehole was drilled to penetrate the Nojima Fault, which was active in the 1995 Hyogo-ken Nanbu earthquake. The purpose of the hydrophone VSP is to detect subsurface permeable fractures and permeable zones and, in the present case, to estimate the permeability of the Nojima Fault. The analysis was based on a model by which tube waves are generated when incident P-waves compress the permeable fractures (or permeable zones) intersecting the borehole and a fluid in the fracture is injected into the borehole. Permeable fractures (or permeable zones) are detected at the depths of tube wave generation, and fracture permeability is calculated from the amplitude ratio of tube wave to incident P-wave. Several generations of tube waves were detected from the VSP sections. Distinct tube waves were generated at depths of the fault zone that are characterized by altered and deformed granodiorite with a fault gouge, suggesting that permeable fractures and permeable zones exist in the fault zone. Tube wave analysis shows that the permeability of the fault gouge from 624 m to 625 m is estimated to be approximately 2 × 10−12 m2.  相似文献   

6.
Abstract Crack-filling clays and weathered cracks were observed in the Disaster Prevention Research Institute, Kyoto University (DPRI) 1800 m cores drilled from the Nojima Fault Zone, which was activated during the 1995 Hyogo-ken Nanbu earthquake (Kobe earthquake). The crack-filling clays consist mainly of unconsolidated fine-grained materials that fill opening cracks with no shear textures. Most of the cracks observed in the DPRI 1800 m cores are yellow-brown to brown in color due to weathering. Powder X-ray diffraction analyses show that the crack-filling clays are composed mainly of clay minerals and carbonates such as siderite and calcite. Given that the top of the borehole is approximately 45 m above sea level, most of the core is far below the stable groundwater table. Hence, it is suggested that the crack-filling clays and weathered cracks in the cores taken at depths of 1800 m were formed by the flow of surface water down to the deep fractured zone of the Nojima Fault Zone during seismic faulting.  相似文献   

7.
Abstract An 800 m borehole was drilled near the Nojima Fault, on which a strike–slip larger then 1 m occurred during the 1995 Hyogo-ken Nanbu earthquake ( M = 7.2). Crustal activity near the fault has been observed since May 1996 using a multicomponent instrument installed at the bottom of the borehole. Data of three components of strain, two components of tilt and temperature observed from May 1996 to December 1998 were analyzed. Long-term changes of strain and tilt show a north-east–south-west extension and southwards subsidence. As for the Earth tides and atmospheric effect, orientation of the principal axis of strain was mainly east-west and orientation of the maximum subsidence was mainly north-south. The observational data of strain had variations corresponding to a change in temperature at a depth of 800 m. The thermal expansion coefficient of the crust was calculated to be approximately 2.0 × 10−6/°K.  相似文献   

8.
Abstract The internal structures of the Nojima Fault, south-west Japan, are examined from mesoscopic observations of continuous core samples from the Hirabayashi Geological Survey of Japan (GSJ) drilling. The drilling penetrated the central part of the Nojima Fault, which ruptured during the 1995 Kobe earthquake (Hyogo-ken Nanbu earthquake) ( M 7.2). It intersected a 0.3 m-thick layer of fault gouge, which is presumed to constitute the fault core (defined as a narrow zone of extremely concentrated deformation) of the Nojima Fault Zone. The rocks obtained from the Hirabayashi GSJ drilling were divided into five types based on the intensities of deformation and alteration: host rock, weakly deformed and altered granodiorite, fault breccia, cataclasite, and fault gouge. Weakly deformed and altered granodiorite is distributed widely in the fault zone. Fault breccia appears mostly just above the fault core. Cataclasite is distributed mainly in a narrow (≈1 m wide) zone in between the fault core and a smaller gouge zone encountered lower down from the drilling. Fault gouge in the fault core is divided into three types based on their color and textures. From their cross-cutting relationships and vein development, the lowest fault gouge in the fault core is judged to be newer than the other two. The fault zone characterized by the deformation and alteration is assumed to be deeper than 426.2 m and its net thickness is > 46.5 m. The fault rocks in the hanging wall (above the fault core) are deformed and altered more intensely than those in the footwall (below the fault core). Furthermore, the intensities of deformation and alteration increase progressively towards the fault core in the hanging wall, but not in the footwall. The difference in the fault rock distribution between the hanging wall and the footwall might be related to the offset of the Nojima Fault and/or the asymmetrical ground motion during earthquakes.  相似文献   

9.
Abstract A water injection experiment was carried out by the scientific drilling program named the 'Nojima Fault Zone Probe' during the two periods 9–13 February and 16–25 March 1997. The pumping pressure at the surface was approximately 4 MPa. The total amount of injected water was 258 m3. The injection was made between depths of 1480 m and 1670 m in the Disaster Prevention Research Institute, Kyoto University (DPRI) 1800 m borehole drilled into the Nojima Fault zone. A seismic observation network was deployed to monitor seismic activity related to the water injections. Seismicity suddenly increased in the region not far from the injection hole 4 or 5 days after the beginning of each water injection. These earthquakes were likely to be induced by the water injections. Most of the earthquakes had magnitudes ranging from −2 to +1. Numerous earthquakes occurred during the first injection, but only one could be reliably located and it was approximately 2 km north of the injection site. Between the two injection periods, earthquakes concentrated in the region approximately 1 km northwest of the injection site. During and after the second injection experiment, earthquakes were located approximately 1.5 km west of the injection site. Those earthquakes were located approximately 3 km or 4 km from the injection point and between 2 km and 4 km in depth. Values of intrinsic permeability of 10−14–10−15 m2 were estimated from the time lapse of the induced seismic activity. The coefficient of friction in the area where the induced earthquakes occurred was estimated to be less than 0.3.  相似文献   

10.
Abstract Long-term monitoring of temperature distribution in an active fault zone was carried out using the optical fiber temperature-sensing technique. An optical fiber cable was installed in a borehole drilled into the Nojima Fault in Awaji Island, south-west Japan, and the temperature profile to a depth of 1460 m had been measured for 2.5 years (July 1997–January 2000). Although the obtained temperature records showed small temporal variations due to drifts of the measurement system all along the cable, local temperature anomalies were detected at two depths. One at around 80 m seems to correspond to a fracture zone and may be attributed to groundwater flow in the fracture zone. This anomaly had been stable throughout the monitoring period, whereas the other anomaly at around 500 m was a transient one. The water level in the borehole could be estimated from the diurnal temperature variations in the uppermost part of the borehole and may provide information on the hydrological characteristics of the fault zone, which is connected to the borehole through perforations on the casing pipe. Except for these minor variations, the temperature profile had been very stable for 2.5 years. The conductive heat flow calculated from this profile and the thermal conductivity measured on core samples increases with depth, probably resulting from errors in thermal conductivity due to sampling problems and/or from advective heat transfer by regional groundwater flow. Assuming that the middle part of the borehole (less fractured granite layer) is least affected by these factors, heat flow at this site is estimated to be approximately 70 mW/m2.  相似文献   

11.
Abstract Anisotropy of magnetic susceptibility (AMS) has been used to infer finite strain fabrics in plastically deformed rocks, but there are few studies of magnetic properties in fractured fault rocks. Changes in magnetic and fractal properties of fractured granites from the Disaster Prevention Research Institute, Kyoto University (DPRI) 500 m drilling core towards the Nojima Fault and of the well-foliated fault gouge are described. Fractal analysis of fractured granites shows that the fractal dimension ( D ) increases linearly toward the gouge zone of the fault. In weakly fractured granites ( D = 1.05–1.24), it was found that the degree of AMS correlates positively with the fractal dimension, suggesting a fracture-related magnetic fabric due to fracturing. In strongly fractured granites ( D = 1.25–1.50), weaker, nearly isotropic AMS is found, suggesting erasure by the fragmentation of the magnetic minerals. Within the fault gouge zone, an isotropic AMS fabric was found, as well as twofold increases in magnetic intensity and susceptibility. These changes reflect the production of new magnetite grains, subsequently confirmed by hysteresis studies, which suggests that fault gouge might be regarded as the source of the regional geomagnetic field contrast along active faults. Thus, AMS is clearly a potentially useful tool for inferring the fracturing texture of magnetic minerals in fractured rocks and detecting active faults from the high susceptibility contrast of fault gouge.  相似文献   

12.
Ryuji Ikeda 《Island Arc》2001,10(3-4):199-205
Abstract Three boreholes, 1001 m, 1313 m and 1838 m deep, were drilled by the National Research Institute for Earth Science and Disaster Prevention (NIED) in the vicinity of the epicenter of the 1995 Hyogo-ken Nanbu (Kobe) earthquake to investigate tectonic and material characteristics near and in active faults. Using these boreholes, an integrated study of the in situ stress, heat flow, and material properties of drill cores and crustal resistivity was conducted. In particular, the Nojima–Hirabayashi borehole was drilled to a depth of 1838 m and directly intersected the Nojima Fault, and three possible fault strands were detected at depths of 1140 m, 1313 m and 1800 m. Major results obtained from this study include the following: (i) shear stress around the fault zone is very small, and the orientation of the maximum horizontal compression is perpendicular to the surface trace of faults; (ii) from the results of a heat flow study, the lower cut-off depth of the aftershocks was estimated to be roughly 300°C; (iii) cores were classified into five types of fault rocks, and an asymmetric distribution pattern of these fault rocks in the fracture zones was identified; (iv) country rock is characterized by a very low permeability and high strength; and (v) resistivity structure can be explained by a model of a fault extending to greater depths but with low resistivity.  相似文献   

13.
Abstract Mineralogical and geochemical studies on the fault rocks from the Nojima–Hirabayashi borehole, south-west Japan, are performed to clarify the alteration and mass transfer in the Nojima Fault Zone at shallow depths. A complete sequence from the hornblende–biotite granodiorite protolith to the fault core can be observed without serious disorganization by surface weathering. The parts deeper than 426.2 m are in the fault zone where rocks have suffered fault-related deformation and alteration. Characteristic alteration minerals in the fault zone are smectite, zeolites (laumontite, stilbite), and carbonate minerals (calcite and siderite). It is inferred that laumontite veins formed at temperatures higher than approximately 100°C during the fault activity. A reverse component in the movement of the Nojima Fault influences the distribution of zeolites. Zeolite is the main sealing mineral in relatively deep parts, whereas carbonate is the main sealing mineral at shallower depths. Several shear zones are recognized in the fault zone. Intense alteration is localized in the gouge zones. Rock chemistry changes in a different manner between different shear zones in the fault zone. The main shear zone (MSZ), which corresponds to the core of the Nojima Fault, shows increased concentration of most elements except Si, Al, Na, and K. However, a lower shear zone (LSZ-2), which is characterized by intense alteration rather than cataclastic deformation, shows a decreased concentration of most elements including Ti and Zr. A simple volume change analysis based on Ti and Zr immobility, commonly used to examine the changes in fault rock chemistry, cannot account fully for the different behaviors of Ti and Zr among the two gouge zones.  相似文献   

14.
Abstract Self-potential variations were measured to estimate the magnitude of electrokinetic and hydrological parameters (zeta potential and permeability) of the Nojima Fault zone in Awaji, Japan. The study observed self-potential variations that seemed to be associated with water flow from the injection well to the fracture zone, which were induced by turning the injection on and off. Amplitudes of the variations were a few to 0.03 V across 320–450 m dipoles. These variations can be explained well with an electrokinetic model. The quantity k/ζ (permeability/zeta potential) is in the range 1.6 × 10−13− 5.4 × 10−13 m2/V. Permeability of the Nojima fault zone can be estimated as approximately 10−16–10−15 m2 on the assumption that the zeta potential is in the range –0.01 to –0.001 V.  相似文献   

15.
Abstract The 1995 Hyogo-ken Nanbu (Kobe) earthquake, M 7.2, occurred along the north-east–south-west trending Rokko–Awaji Fault system. Three boreholes of 1001 m, 1313 m and 1838 m deep were drilled in the vicinity of the epicenter of the earthquake. Each borehole is located at characteristic sites in relation to active faults and the aftershock distribution. In particular, the Nojima–Hirabayashi borehole [Hirabayashi National Research Institute for Earth Science and Disaster Prevention (NIED) drilling] in Awaji Island was drilled to a depth of 1838 m, approximately 320 m southeast from the surface rupture of the Nojima Fault, and it crosses fracture zones below a depth of 1140 m. In situ stress measurements by the hydraulic fracturing method were conducted in these boreholes within 1.5 years after the earthquake. Measurement results suggest the following: (i) Differential stress values are very small, approximately 10 MPa at a depth of 1000 m at each site; (ii) the orientation of maximum horizontal compression is almost the same in the boreholes, perpendicular to the surface trace of the faults, north-west–south-east; (iii) fault types estimated from the state of stress differ among these sites; and (iv) the differential stress value just beneath the fault fracture zone decreases abruptly to one-half of that above the fault zone in the Hirabayashi NIED drilling. These features support the idea that the shear stress along the Rokko–Awaji Fault system decreased to a low level just after the earthquake.  相似文献   

16.
Abstract Distinctive fault ruptures, the Nojima Fault and Ogura Fault, appeared along the northwestern coast of Awaji Island at the time of the 1995 Hyogo-ken Nanbu earthquake (Kobe earthquake). In order to delineate the shallow resistivity structures around the faults just after they formed, Very Low Frequency Magnetotelluric (VLF-MT) surveys were made at five sites along the Nojima Fault and at one site along the Ogura Fault. Fourteen transects were made at the one site on the Ogura Fault, and another transect covers the area between the two faults. Changes in apparent resistivity or phase, or both, commonly occur when crossing the surface location of one of the faults, except for the northern transects at OGR-0 on the Ogura Fault. Apparent resistivity values of less than 100 Ωm were observed for Tertiary and Quaternary sediments and values larger than 200 Ωm for granitic rocks. The resistivity structures are related to the morphological characteristics of the fault ruptures. Remarkably conductive zones (less than 10 Ωm in apparent resistivity and 30–40 m in width) were found where the surface displacement is distinct and prominent along a single fault plane. If remarkably conductive zones were formed at the time of the 1995 Hyogo-ken Nanbu earthquake, the results provide a good constraint on the dimensions of a conductive zone near the surface that was made by one earthquake. Alternatively, if characteristic resistivity structures existed prior to the earthquake, the conductive zone was probably formed by some tens of earthquakes in relatively modern times. In this case, this phenomenon is inferred to be a concentration of fracturing in a narrow zone and is associated with the formation of clay minerals, which enhance rock conductivity.  相似文献   

17.
The 1995 Kobe (Hyogo-ken Nanbu) earthquake, M = 7.2, ruptured the Nojima fault in southwest Japan. We have studied core samples taken from two scientific drillholes that crossed the fault zone SW of the epicentral region on Awaji Island. The shallower hole, drilled by the Geological Survey of Japan (GSJ), was started 75 m to the SE of the surface trace of the Nojima fault and crossed the fault at a depth of 624 m. A deeper hole, drilled by the National Research Institute for Earth Science and Disaster Prevention (NIED) was started 302 m to the SE of the fault and crossed fault strands below a depth of 1140 m. We have measured strength and matrix permeability of core samples taken from these two drillholes. We find a strong correlation between permeability and proximity to the fault zone shear axes. The half-width of the high permeability zone (approximately 15 to 25 m) is in good agreement with the fault zone width inferred from trapped seismic wave analysis and other evidence. The fault zone core or shear axis contains clays with permeabilities of approximately 0.1 to 1 microdarcy at 50 MPa effective confining pressure (10 to 30 microdarcy at in situ pressures). Within a few meters of the fault zone core, the rock is highly fractured but has sustained little net shear. Matrix permeability of this zone is approximately 30 to 60 microdarcy at 50 MPa effective confining pressure (300 to 1000 microdarcy at in situ pressures). Outside this damage zone, matrix permeability drops below 0.01 microdarcy. The clay-rich core material has the lowest strength with a coefficient of friction of approximately 0.55. Shear strength increases with distance from the shear axis. These permeability and strength observations reveal a simple fault zone structure with a relatively weak fine-grained core surrounded by a damage zone of fractured rock. In this case, the damage zone will act as a high-permeability conduit for vertical and horizontal flow in the plane of the fault. The fine-grained core region, however, will impede fluid flow across the fault.  相似文献   

18.
Abstract Characteristics of deformation and alteration of the 1140 m deep fracture zone of the Nojima Fault are described based on mesoscopic (to the naked eye) and microscopic (by both optical and scanning electron microscopes) observations of the Hirabayashi National Research Institute for Earth Science and Disaster Prevention (NIED) drill core. Three types of fault rocks; that is, fault breccia, fault gouge and cataclasite, appear in the central part of the fault zone and two types of weakly deformed and/or altered rocks; that is, weakly deformed and altered granodiorite and altered granodiorite, are located in the outside of the central part of the fault zone (damaged zone). Cataclasite appears occasionally in the damaged zone. Six distinct, thin foliated fault gouge zones, which dip to the south-east, appear clearly in the very central part of the fracture zone. Slickenlines plunging to the north-east are observed on the surface of the newest gouge. Based on the observations of XZ thin sections, these slickenlines and the newest gouge have the same kinematics as the 1995 Hyogo-ken Nanbu earthquake (Kobe earthquake), which was dextral-reverse slip. Scanning electron microscopy observations of the freeze-dried fault gouge show that a large amount of void space is maintained locally, which might play an important role as a path for fluid migration and the existence of either heterogeneity of pore fluid pressure or strain localization.  相似文献   

19.
Abstract This paper describes the results of petrographical and meso- to microstructural observations of brittle fault rocks in cores obtained by drilling through the Nojima Fault at a drilling depth of 389.52 m. The zonation of deformation and alteration in the central zone of the fault is clearly seen in cores of granite from the hanging wall, in the following order: (i) host rock, which is characterized by some intragranular microcracks and in situ alteration of mafic minerals and feldspars; (ii) weakly deformed and altered rocks, which are characterized by transgranular cracks and the dissolution of mafic minerals, and by the precipitation of zeolites and iron hydroxide materials; (iii) random fabric fault breccia, which is characterized by fragmentation, by anastomosing networks of transgranular cracks, and by the precipitation of zeolites and iron hydroxide materials; and (iv) fault gouge, which is characterized by the precipitation of smectite and localized cataclastic flow. This zonation implies that the fault has been weakened gradually by fluid-related fracturing over time. In the footwall, a gouge layer measuring only 15 mm thick is present just below the surface of the Nojima Fault. These observations are the basis for a model of fluid behavior along the Nojima Fault. The model invokes the percolation of meteoric fluids through cracks in the hanging wall fault zone during interseismic periods, resulting in chemical reactions in the fault gouge layer to form smectite. The low permeability clay-rich gouge layer sealed the footwall. The fault gouge was brecciated during coseismic or postseismic periods, breaking the seal and allowing fluids to readily flow into the footwall, thus causing a slight alteration. Chemical reactions between fluids and the fault breccia and gouge generated new fault gouge, which resealed the footwall, resulting in a low fluid condition in the footwall during interseismic periods.  相似文献   

20.
Stresses at sites close to the Nojima Fault measured from core samples   总被引:2,自引:0,他引:2  
Abstract The Nojima Fault in Awaji, Hyogo prefecture, Japan, was ruptured during the 1995 Hyogo-ken Nanbu earthquake ( M JMA = 7.2). Toshima is located close to the fault segment, in which a large dislocation has been observed on the Earth's surface. Ikuha is near the southern end of the buried fault that extends from the surface rupture. Stresses are measured on core samples taken at depths of 310 m, 312 m and 415 m at Toshima and a depth of 351 m at Ikuha. The measured stresses show that both sites are in the field of a strike–slip regime, but compression dominates at Toshima. Defining the relative shear stress as the maximum shear stress divided by the normal stress on the maximum shear plane, the relative shear stress ranges from 0.42 to 0.54 at Toshima and is approximately 0.32 at Ikuha. While the value at Ikuha is moderate, those at Toshima are comparably large to those in areas close to the inferred fault of the 1984 Nagano-ken Seibu earthquake. Value amounts greater than 0.4 suggest that there are areas of large relative shear stress along faults, thus having the potential to generate earthquakes. Provided that the cores are correctly oriented, the largest horizontal stresses at shallow depths are in the direction from N113°E to N139°E at Toshima and N74°E at Ikuha, indicating that the fault does not orient optimally for the stress field at both sites. The slip is known to be predominant in the right-lateral strike–slip component. Although this slip may appear contradictory to the stress field at Toshima, the slip direction is found to be parallel to the measured stresses resolved on the fault plane for the first approximation. The ratio of shear stress to normal stress on the fault plane is roughly estimated to be greater than zero and smaller than 0.3 near Toshima.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号