首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Many reinforced‐concrete frames collapse via a soft‐story mechanism during severe earthquakes. Such collapses are mainly attributed to concentrated deformation in a soft story. Deformation control is thus important in preventing collapse. The frame pin‐supported wall structure is a type of rocking structure that releases constraints at the bottom of the wall. Previous research has obtained good results for the deformation control of this type of structure. However, the interior forces and strength demands of the pin‐supported wall have not been systematically explored. In this paper, a distributed parameter model is developed to investigate the strength demand of the wall in a frame pin‐supported wall structure. In the model, the pin‐supported wall is simplified as a bending beam and the frame is simplified as a shear beam. The two beams are joined by distributed shear connectors, so that the shear force can be transferred at any location on the interface. The model can be solved using differential equations based on equilibrium and compatibility. The accuracy of the model is verified using SAP2000 (Computers and Structures Inc., Berkeley, CA, USA). Displacement distribution of the structure and distributions of the moment and shear force within the pin‐supported wall are obtained for two typical external force profiles. It is found that the pin‐supported wall can effectively reduce the drift concentration factor. Distributions of the displacement, moment, and shear force are closely correlated with the relative stiffness of the wall and frame. Finally, recommendations on the stiffness and strength of a pin‐supported wall are made. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
Gaps between beam‐to‐column interfaces in a post‐tensioned (PT) self‐centering frame with more than one column are constrained by columns, which causes beam compression force different from the applied PT force. This study proposes an analytical method for evaluating column bending stiffness and beam compression force by modeling column deformation according to gap‐openings at all stories. The predicted compression forces in the beams are validated by a cyclic analysis of a three‐story PT frame and by cyclic tests of a full‐scale, two‐bay by first‐story PT frame, which represents a substructure of the three‐story PT frame. The proposed method shows that compared with the strand tensile force, the beam compression force is increased at the 1st story but is decreased at the 2nd and 3rd stories due to column deformation compatibility. The PT frame tests show that the proposed method reasonably predicts beam compression force and strand force and that the beam compression force is 2 and 60% larger than the strand force with respect to a minor restraint and a pin‐supported boundary condition, respectively, at the tops of the columns. Therefore, the earlier method using a pin‐supported boundary condition at upper story columns represents an upper bound of the effect and is shown to be overly conservative for cases where a structure responds primarily in its first mode. The proposed method allows for more accurate prediction of the column restraint effects for structures that respond in a pre‐determined mode shape which is more typical of low and mid‐rise structures. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
This paper describes an analytical investigation on a reinforced concrete lateral load resisting structural system comprising a pin‐supported (base‐rocking) shear wall coupled with a moment frame on 1 or both sides of the wall. Yielding dampers are used to provide supplemental energy dissipation through the relative displacements at the vertical connections between the wall and the frames. The study extends a previous linear‐elastic model for pin‐supported wall‐frame structures by including the effects of the dampers. A closed‐form solution of the lateral load behavior of the structure is derived by approximating the discrete wall‐frame‐damper interactions with distributed (ie, continuous) properties. The validity of the model is verified by comparing the closed‐form results with computational models using OpenSees program. Then, a parametric analysis is conducted to investigate the effects of the wall, frame, and damper stiffness on the behavior of the structure. It is found that the damper stiffness significantly affects the distribution of shear forces and bending moments over the wall height. Finally, the performance‐based plastic design approach extended to the wall‐frame‐damper system is proposed. Case studies are carried out to design 2 damped pin‐supported wall‐frame structures using the proposed approach. Nonlinear dynamic time‐history analyses are conducted to verify the effectiveness of this method. Results indicate that the designed structures can achieve the performance level with the story drift ratios less than target values, and weak‐story failure mechanism is not observed. The approach can be used in engineering applications.  相似文献   

4.
Frame pin‐supported wall structure is a kind of rocking structure, which releases constraints at the bottom of the wall. The wall is affiliated to the frame and can rotate around the hinge. Previous studies have investigated seismic performance (such as deformation pattern and plastic hinge distribution) of frame pin‐supported wall structure. Strength demand of this system was investigated through static pushover analysis. However, dynamic characteristics, especially higher mode effects, remain to be quantified. As demonstrated in several researches, higher mode effects have non‐negligible effects on seismic response. For this purpose, a distributed model for analyzing higher mode effects in frame pin‐supported wall structure was proposed, where the pin‐supported wall and the frame were simplified as a bending beam and a shear beam, respectively. The model was solved by differential equations derived from equilibrium and compatibility. Displacement and inner force distribution of frame pin‐supported wall structure in higher modes were quantified according to the model. Influence of critical parameters, such as wall stiffness and structure period, was assessed on higher mode effects. It was demonstrated that response in higher modes cannot be neglected in the design of frame pin‐supported wall structure. Capacity design based on the fundamental mode is not conservative, especially in the wall. Furthermore, pin‐supported walls tend to force the frame to vibrate in the rocking mode and suppress higher mode effects in the frame. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
This paper presents results from a numerical investigation into the seismic retrofit of a soft story frame using a novel gapped‐inclined brace (GIB) system. The GIB system consists of a pinned brace and a gap element that is added to the first story columns of the frame. The inclusion of GIB elements in addition to increasing the lateral capacity of columns at the first story increases the post‐yield stiffness ratio of the system and reduces the P‐delta effects on the columns, while not increasing the first story lateral resistance or stiffness. This allows for the isolating benefits of the soft story to protect the upper floors of the structure from damage while avoiding excessive deformations and reducing the propensity for collapse. A six‐story RC frame with masonry infills on all floors except for the first floor is studied. The dynamic response of the retrofitted building using the GIB system is investigated numerically and is compared with the response of the original un‐retrofitted building and the same building in which masonry infills are added to the first story to mitigate the soft story response. Results from the nonlinear time‐history analyses indicate that the GIB system could provide a reliable seismic retrofit mechanism for soft story buildings, which greatly reduces the likelihood of collapse by increasing the displacement capacity of the soft storey and by reducing P‐delta effects, while minimizing the overall damage and losses in the building by taking advantages of the isolation that is provided by the soft story to the rest of the structure located above. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
Given their excellent self‐centering and energy‐dissipating capabilities, superelastic shape memory alloys (SMAs) become an emerging structural material in the field of earthquake engineering. This paper presents experimental and numerical studies on a scaled self‐centering steel frame with novel SMA braces (SMAB), which utilize superelastic Ni–Ti wires. The braces were fabricated and cyclically characterized before their installation in a two‐story one‐bay steel frame. The equivalent viscous damping ratio and ‘post‐yield’ stiffness ratio of the tested braces are around 5% and 0.15, respectively. In particular, the frame was seismically designed with nearly all pin connections, including the pinned column bases. To assess the seismic performance of the SMA braced frame (SMABF), a series of shake table tests were conducted, in which the SMABF was subjected to ground motions with incremental seismic intensity levels. No repair or replacement of structural members was performed during the entire series of tests. Experimental results showed that the SMAB could withstand several strong earthquakes with very limited capacity degradation. Thanks to the self‐centering capacity and pin‐connection design, the steel frame was subjected to limited damage and zero residual deformation even if the peak interstory drift ratio exceeded 2%. Good agreement was found between the experimental results and numerical simulations. The current study validates the prospect of using SMAB as a standalone seismic‐resisting component in critical building structures when high seismic performance or earthquake resilience is desirable under moderate and strong earthquakes. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

7.
A summary of the development of a new coupled shear‐bending model for analysis of stacked wood shear walls and multi‐story wood‐frame buildings is presented in this paper. The model focuses on dynamic response of light‐frame wood structures under seismic excitation. The formulation is intended to provide a more versatile option than present pure shear models in that the new model is capable of accurately capturing the overall lateral response of each story diaphragm and separates the inter‐story shear deformation and the deformation associated with rotation of the diaphragm due to rod elongation, which is an analogue to the bending deformation in an Euler–Bernoulli beam model. Modeling the coupling of bending and shear deformation is shown to provide more accurate representation of stacked shear wall system behavior than a pure shear model, particularly for the upper stories in the assembly. The formulation is coupled with the newly developed evolutionary parameter hysteretic model for wood shear walls. Existing data from a shake table test of an isolated three‐story wood shear wall were used to verify the accuracy of the model prediction. The numerical results agreed very well with shake table test measurements. The influence of a continuous rod hold‐down system on the dynamic behavior of the three‐story stacked wood shear wall was also successfully simulated. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
This paper describes a new seismic protection system for timber platform frame buildings, either for new construction or retrofit. The system consists in connecting the timber frame to a steel structure that includes hysteretic energy dissipators designed to absorb most of the seismic input energy thus protecting the timber frame and the other steel members; alternatively, the system might use other types of dissipative devices. The steel structure consists of four steel stacks (located at each of the four façades) and steel collectors embracing each slab; the stacks and the collectors are connected, at each floor level, through the energy dissipators. The steel structure is self‐supporting, that is, the timber frame is not affected by horizontal actions and can be designed without accounting for any seismic provision; in turn, the steel members do not participate in the main load‐carrying system. The timber‐steel interface is designed to avoid any stress concentration in the transfer of horizontal forces and to guarantee that the yielding of the dissipators occurs prior to any timber failure. The energy dissipation capacity of the suggested system is discussed, and an application example on a six‐story timber building is presented; this case corresponds to highly demanding conditions because of the relatively large building height and weight, the high local seismicity, and the soft soil condition. This research belongs to a wider project aiming to promote the structural use of timber by improving the seismic capacity of wooden buildings; this research includes experiments and advanced numerical simulation. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
Near‐fault ground motions with forward directivity are characterized by a large pulse. This pulse‐like motion may cause a highly non‐uniform distribution of story ductility demands for code‐compliant frame structures, with maximum demands that may considerably exceed the level of code expectations. Strengthening techniques for multi‐story frame structures are explored with the objective of reducing maximum drift demands. One option is to modify the code‐based SRSS distribution of story shear strength over the height by strengthening of the lower stories of the frame. The modified distribution reduces the maximum story ductility demand, particularly for weak and flexible structures. However, this strengthening technique is less effective for stiff structures, and is almost ineffective in cases in which the maximum demand occurs in the upper stories, i.e. strong and flexible structures. As an alternative, the benefits of strengthening frames with elastic and inelastic walls are evaluated. The effects of adding walls that are either fixed or hinged at the base are investigated. It is demonstrated that strengthening with hinged walls is very effective in reducing drift demands for structures with a wide range of periods and at various performance levels. Wall inelastic behavior only slightly reduces the benefits of strengthening with hinged walls.Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

10.
针对既有的C类框架学校建筑提高一度抗震设防的加固目标,从地震作用计算、结构抗震验算和抗震构造措施等方面详细分析了其中的加固难点,指出了应用传统抗震加固方法的一些不足之处,探讨了应用消能减震技术进行结构提高一度抗震设防加固的可行性;并以某C类框架学校建筑加固工程为实例,从减震控制效果分析、弹塑性变形验算、消能部件影响评价、抗震构造措施核查4个方面论证了消能减震加固方法的有效性和可操作性。结果表明,消能减震技术在C类框架学校建筑抗震加固中具有一定的应用优势,不但能有效控制结构的地震响应,而且依据减震效果可以适当降低结构的抗震构造要求。因此,只要通过合理的消能减震加固设计,再辅以额外的局部加强处理,完全可以实现C类框架学校建筑提高一度抗震设防的加固目标需求。  相似文献   

11.
This paper proposes a novel implementation of buckling‐restrained braces (BRB) in new reinforced concrete (RC) frame construction. Seismic design and analysis methods for using a proposed steel cast‐in anchor bracket (CAB) to transfer normal and shear forces between the BRB and RC members are investigated. A full‐scale two‐story RC frame with BRBs (BRB‐RCF) is tested using hybrid and cyclic loading test procedures. The BRBs were arranged in a zigzag configuration and designed to resist 70% of the story shear. The gusset design incorporates the BRB axial and RCF actions, while the beam and column members comply with ACI 318‐14 seismic design provisions. Test results confirm that the BRBs enhanced the RCF stiffness, strength, and ductility. The hysteresis energy dissipation ratios in the four hybrid tests range from 60% to 94% in the two stories, indicating that BRBs can effectively dissipate seismic input energy. When the inter‐story drift ratio for both stories reached 3.5% in the cyclic loading test, the overall lateral force versus deformation response was still very stable. No failure of the proposed steel CABs and RC discontinuity regions was observed. This study demonstrates that the proposed design and construction methods for the CABs are effective and practical for real applications. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
Centralized semi‐active control is a technique for controlling the whole structure using one main computer. Centralized control systems introduce better control for relatively short to medium high structures where the response of any story cannot be separated from the adjacent ones. In this paper, two centralized control approaches are proposed for controlling the seismic response of post‐tensioned (PT) steel frames. The first approach, the stiffness control approach, aims to alter the stiffness of the PT frame so that it avoids large dynamic amplifications due to earthquake excitations. The second approach, deformation regulation control approach, aims at redistributing the demand/strength ratio in order to provide a more uniform distribution of deformations over the height of the structure. The two control approaches were assessed through simulations of the earthquake response of semi‐actively and passively controlled six‐story post‐tensioned steel frames. The results showed that the stiffness control approach is efficient in reducing the frame deformations and internal forces. The deformation regulation control approach was found to be efficient in reducing the frame displacements and generating a more uniform distribution of the inter‐story drifts. These results indicate that centralized semi‐active control can be used to improve the seismic performance of post‐tensioned steel frames. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
Two‐story, three‐bay reinforced concrete (RC) frames with and without internal steel frame (ISF) retrofits were tested using continuous pseudo dynamic test method. The ISFs were installed to the middle bay of the RC frame. Test results indicated that ISF retrofit was beneficial in resisting deformation demands without significant damage under simulated ground motions. The ISF shifted the failure mode of the system from a brittle to a ductile mode. The test results were compared with the results of the nonlinear time history analysis. The analysis results were capable of tracing the overall behavior of global response parameters; however, estimations of local demand parameters were less accurate. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
Dynamic finite element analyses of a four‐story steel building frame modeled as a fine mesh of solid elements are performed using E‐Simulator, which is a parallel finite element analysis software package for precisely simulating collapse behaviors of civil and building structures. E‐Simulator is under development at the National Research Institute for Earth Science and Disaster Prevention (NIED), Japan. A full‐scale shake‐table test for a four‐story frame was conducted using E‐Defense at NIED, which is the largest shaking table in the world. A mesh of the entire structure of a four‐story frame with approximately 19 million degrees of freedom is constructed using solid elements. The density of the mesh is determined by referring to the results of elastic–plastic buckling analyses of a column of the frame using meshes of different densities. Therefore, the analysis model of the frame is well verified. Seismic response analyses under 60, 100, and 115% excitations of the JR Takatori record of the 1995 Hyogoken‐Nanbu earthquake are performed. Note that the simulation does not reproduce the collapse under the 100% excitation of the Takatori record in the E‐Defense test. Therefore, simulations for the 115% case are also performed. The results obtained by E‐Simulator are compared with those obtained by the E‐Defense full‐scale test in order to validate the results obtained by E‐Simulator. The shear forces and interstory drift angles of the first story obtained by the simulation and the test are in good agreement. Both the response of the entire frame and the local deformation as a result of elastic–plastic buckling are simulated simultaneously using E‐Simulator. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
Improving seismic performance is one of the critical objectives in earthquake engineering. With the development of economy and society, reparability and fast resilience of a structure are becoming increasingly important. Reinforced concrete (RC) frame structure is prone to soft story mechanism. As a result, deformation and damage are so concentrated that reparability is severely hampered. Rocking wall provides an available approach for deformation control in RC frame by introducing a continuous component along the height. Previous researches mostly focus on seismic responses of rocking wall frame structures, while damage mode and reparability have not been investigated in detail. In this study, a novel infilled rocking wall frame (IRWF) structure is proposed. A half‐scaled IRWF model was designed according to Chinese seismic design code. The model was subjected to cyclic pushover testing up to structure drift ratio of 1/50 (amplitude 1/50), and its reparability was evaluated thereafter. Retrofit was implemented by wrapping steel plates and installing friction dampers. The retrofitted model was further loaded up to amplitude 1/30. The IRWF model showed excellent reparability and satisfactory seismic performance on deformation control, damage mode, hysteresis behavior, and beam‐to‐column joint rotation. After retrofitting, capacity of the model was improved by 11% with limited crack distribution. The model did not degrade until amplitude 1/30, due to shear failure in frame beams. The retrofit procedure was proved effective, and reparability of the IRWF model was demonstrated. Seismic resilience tends to be achieved in the proposed system.  相似文献   

16.
This paper is Part II of a two‐part paper describing a full‐scale 3‐story 3‐bay concrete‐filled tube (CFT)/buckling‐restrained braced frame (BRBF) specimen tested using psuedo‐dynamic testing procedures. The first paper described the specimen design, experiment, and simulation, whereas this paper focuses on the experimental responses of BRBs and BRB‐to‐gusset connections. This paper first evaluates the design of the gusset connections and the effects of the added edge stiffeners in improving the seismic performance of gusset connections. Test results suggest that an effective length factor of 2.0 should be considered for the design of the gusset plate without edge stiffeners. Tests also confirm that the cumulative plastic deformation (CPD) capacity of the BRBs adopted in the CFT/BRBF was lower than that found in typical component tests. The tests performed suggest that the reduction in the BRB CPD capacities observed in this full‐scale frame specimen could be due to the significant rotational demands imposed on the BRB‐to‐gusset joints. A simple method of computing such rotational demands from the frame inter‐story drift response demand is proposed. This paper also discusses other key experimental responses of the BRBs, such as effective stiffness, energy dissipation, and ductility demands. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
Collapse resistance of high‐rise buildings has become a research focus because of the frequent occurrence of strong earthquakes and terrorist attacks in recent years. Research development has demonstrated that numerical simulation is becoming one of the most powerful tools for collapse analysis in addition to the conventional laboratory model tests and post‐earthquake investigations. In this paper, a finite element method based numerical model encompassing fiber‐beam element model, multilayer shell model, and elemental deactivation technique is proposed to predict the collapse process of high‐rise buildings subjected to extreme earthquake. The potential collapse processes are simulated for a simple 10‐story RC frame and two existing RC high‐rise buildings of 18‐story and 20‐story frame–core tube systems. The influences of different failure criteria used are discussed in some detail. The analysis results indicate that the proposed numerical model is capable of simulating the collapse process of existing high‐rise buildings by identifying potentially weak components of the structure that may induce collapse. The study outcome will be beneficial to aid further development of optimal design philosophy. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
A new isolation interface is proposed in this study to retrofit existing buildings with inadequate soft stories as well as new structures to be constructed with soft first story intended for architectural or functional purposes. The seismic interface is an assembly of bearings set in parallel on the top of the first story columns: the multiple‐slider bearings and rubber bearings. The multiple‐slider bearing is a simple sliding device consisting of one horizontal and two inclined plane sliding surfaces based on polytetrafluoroethylene and highly polished stainless steel interface at both ends set in series. A numerical example of a five‐story reinforced concrete shear frame with soft first story is considered and analyzed to demonstrate the efficiency of the proposed isolation system in reducing the ductility demand and damage in the structure while maintaining the superstructure above the bearings to behave nearly in the elastic range with controlled bearing displacement. Comparative study with the conventional system as well as various isolation systems such as rubber bearing interface and resilient sliding isolation is carried out. Moreover, an optimum design procedure for the multiple‐slider bearing is proposed through the trade‐off between the maximum bearing displacement and the first story ductility demand ratio. The results of extensive numerical analysis verify the effectiveness of the multiple‐slider bearing in minimizing the damage from earthquake and protecting the soft first story from excessively large ductility demand. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
A new type of energy‐dissipated structural system for existing buildings with story‐increased frames is presented and investigated in this paper. In this system the sliding‐friction layer between the lowest increased floor of the outer frame structure and the roof of the original building is applied, and energy‐dissipated dampers are used for the connections between the columns of the outer frame and each floor of the original building. A shaking table test is performed on the model of the system and the simplified structural model of this system is given. The theory of the non‐classical damping approach is introduced to the calculation analyses and compared with test results. The results show that friction and energy‐dissipated devices are very effective in reducing the seismic response and dissipating the input energy of the model structure. Finally, the design scheme and dynamic time‐history analyses of an existing engineering project are investigated to illustrate the application and advantages of the given method. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

20.
Post‐tensioned (PT) self‐centering moment‐resisting frames (MRFs) have recently been developed as an alternative to welded moment frames. The first generation of these systems incorporated yielding energy dissipation mechanisms, whereas more recently, PT self‐centering friction damped (SCFR) moment‐resistant connections have been proposed and experimentally validated. Although all of these systems exhibited good stiffness, strength and ductility properties and stable dissipation of energy under cyclic loading, questions concerning their ultimate response still remained and a complete design methodology to allow engineers to conceive structures using these systems was also needed. In this paper, the mechanics of SCFR frames are first described and a comprehensive design procedure that accounts for the frame behavior and the nonlinear dynamics of self‐centering frames is then elaborated. A strategy for the response of these systems at ultimate deformation stages is then proposed and detailing requirements on the beams in order to achieve this response are outlined. The proposed procedure aims to achieve designs where the interstory drifts for SCFR frames are similar to those of special steel welded moment‐resisting frames (WMRFs). Furthermore, this procedure is adapted from current seismic design practices and can be extended to any other PT self‐centering steel frame system. A six‐story building incorporating WMRFs was designed and a similar building incorporating SCFR frames were re‐designed by the proposed seismic design procedure. Time‐history analyses showed that the maximum interstory drifts and maximum floor accelerations of the SCFR frame were similar to those of the WMRF but that almost zero residual drifts were observed for the SCFR frame. The results obtained from the analyses confirmed the validity of the proposed seismic design procedure, since the peak drift values were similar to those prescribed by the seismic design codes and the SCFR frames achieved the intended performance level under both design and maximum considerable levels of seismic loading. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号