1.
Moat wall pounding occurs when a base-isolated building displaces beyond the provided clearance and collides with the surrounding retaining wall, inducing very high floor accelerations and interstory drifts. Previous studies on moat wall pounding typically employ simplified models of the superstructure, with a uniaxial contact spring used to model the entire moat wall. Consequently, researchers have developed sophisticated contact models to estimate the normal-direction contact force that is generated during seismic pounding. This study examines how the choice in contact model affects the seismic response of a base-isolated building subjected to impact-inducing ground excitation. Five widely used state-of-the-art contact models are summarized and implemented into an experimentally-calibrated numerical model of a base-isolated moment frame. Results of nonlinear dynamic time history analyses are shown in detail for one ground motion, followed by a larger parametric study across 28 near-fault ground motions. This work shows that peak impact force and base acceleration are moderately sensitive to the choice in contact model, while upper floor accelerations and interstory drifts are practically not affected.  相似文献   

2.
Base isolated buildings subjected to extreme earthquakes can exceed their design displacements and impact against the surrounding moat wall. To better understand the consequences of impact on the superstructure, an impact element considering moat wall flexibility is proposed based on impact theory and observations during experimental simulations. It is demonstrated that numerical simulations using the proposed impact element can capture the dominant characteristics of the contact force observed in experiments of base isolated buildings impacting various moat wall configurations including concrete walls with soil backfill and rigid steel walls. The contact force is dependent on impact velocity, geometry, and material properties at the contact surface, and the global dynamic characteristic of the moat wall. Properties of the moat wall impact element are derived based on mechanics‐based models considering material properties and geometric measurements of the experimental setup. For this purpose, the moat wall is modeled as a flexural column with a concentrated nonlinear hinge at its base and soil backfill considered through a damped elastic foundation then generalized into a single degree of freedom system. The resulting impact element is shown to accurately capture both local deformation and the vibration aspects of impact observed in experiments and the effects of impact on superstructure response. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
Structural impact between adjacent buildings may induce local and, in some extreme cases, severe damage, especially in the case of seismically isolated buildings. This study parametrically investigates in the three‐dimensional domain the effect of pounding on the peak response of base‐isolated buildings, which are simulated as nonlinear three‐dimensional multi‐degree‐of‐freedom systems. Firstly, it is shown that considering unidirectional, instead of bidirectional, excitations may lead to underestimation of the base drift demands. Subsequently, the peak responses of seismically isolated buildings utilizing lead rubber bearings are studied while varying important parameters, such as the incidence angle of seismic excitations, the available seismic clearance, and mass eccentricities, under the action of bidirectional horizontal excitations. A large number of numerical simulations are performed using a specially developed software that implements an efficient approach to model impacts, taking into account arbitrary locations of contact points. It is found that the peak interstory drift ratio is significantly influenced by the directionality of the ground motion. Therefore, the seismic performance of structures should ideally be assessed examining the peak structural response while bidirectional ground motions are imposed at various incident angles. Furthermore, it is also observed that the interstory drift ratios increase while decreasing the available gap size, up to a certain value. Finally, the parametric analyses indicate that the effects of impact are more severe for structures with mass eccentricities, and in which case, the estimation of the critical incidence angle becomes more laborious. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
Seismic pounding of base‐isolated buildings has been mostly studied in the past assuming unidirectional excitation. Therefore, in this study, the effects of seismic pounding on the response of base‐isolated reinforced concrete buildings under bidirectional excitation are investigated. For this purpose, a three‐dimensional finite element model of a code‐compliant four‐story building is considered, where a newly developed contact element that accounts for friction and is capable of simulating pounding with retaining walls at the base, is used. Nonlinear behavior of the superstructure as well as the isolation system is considered. The performance of the building is evaluated separately for far‐fault non‐pulse‐like ground motions and near‐fault pulse‐like ground motions, which are weighted scaled to represent two levels of shaking viz. the design earthquake (DE) level and the risk‐targeted maximum considered earthquake (MCER) level. Nonlinear time‐history analyses are carried out considering lower bound as well as upper bound properties of isolators. The influence of separation distance between the building and the retaining walls at the base is also investigated. It is found that if pounding is avoided, the performance of the building is satisfactory in terms of limiting structural and nonstructural damage, under DE‐level motions and MCER‐level far‐fault motions, whereas unacceptably large demands are imposed by MCER‐level near‐fault motions. In the case of seismic pounding, MCER‐level near‐fault motions are found to be detrimental, where the effect of pounding is mostly concentrated at the first story. In addition, it is determined that considering unidirectional excitation instead of bidirectional excitation for MCER‐level near‐fault motions provides highly unconservative estimates of superstructure demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
Studies have shown the effectiveness of providing supplemental energy dissipation in base‐isolated structures to reduce displacements at the isolation level. A previous analytical study demonstrated the benefits of providing this energy dissipation at a specified gap larger than the design displacement. The gap before engagement allows the base isolation system to meet performance criteria in varying levels of ground excitation. Use of this ‘gap damper’ device eliminates undesirable effects often exhibited with large amounts of supplemental damping at lower intensity motions. Using results from an analytical study, the primary purpose of this research was to develop devices for practical implementation. Development of the devices demanded simplicity, feasibility, economy, and reliability to be an effective option in building design and construction. Multiple designs were proposed, and a final design was chosen based on selection criteria and finite element analyses. The device was designed and tested in Auburn University's Structural Research Lab. Experimental results were compared with theoretical models to verify behavior and make necessary adjustments for a shake table experiment. The design parameters were selected to accommodate re‐use of the device for the shake table test. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
Pounding between adjacent superstructures has been a major cause of highway bridge damage in the past several earthquakes. This paper presents an experimental and analytical study on pounding reduction of highway bridges subjected to earthquake ground motions by using magnetorheological (MR) dampers. An analytical model, which incorporates structural pounding and MR dampers, is developed. A series of shaking table tests on a 1:20 scaled base‐isolated bridge model are performed to investigate the effects of pounding between adjacent superstructures on the dynamics of the structures. Based on the test results, the parameters of the linear and the nonlinear viscoelastic impact models are identified. Performance of the semiactive system for reducing structural pounding is also investigated experimentally, in which the MR dampers are used in conjunction with the proposed control strategy, to verify the effectiveness of the MR dampers. Structural responses are also simulated by using the established analytical model and compared with the shaking table test results. The results show that pounding between adjacent superstructures of the highway bridge significantly increases the structural acceleration responses. For the base‐isolated bridge model considered here, the semiactive control system with MR dampers effectively precludes pounding. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
This paper investigates numerically the seismic response of six seismically base‐isolated (BI) 20‐story reinforced concrete buildings and compares their response to that of a fixed‐base (FB) building with a similar structural system above ground. Located in Berkeley, California, 2 km from the Hayward fault, the buildings are designed with a core wall that provides most of the lateral force resistance above ground. For the BI buildings, the following are investigated: two isolation systems (both implemented below a three‐story basement), isolation periods equal to 4, 5, and 6 s, and two levels of flexural strength of the wall. The first isolation system combines tension‐resistant friction pendulum bearings and nonlinear fluid viscous dampers (NFVDs); the second combines low‐friction tension‐resistant crosslinear bearings, lead‐rubber bearings, and NFVDs. The designs of all buildings satisfy ASCE 7‐10 requirements, except that one component of horizontal excitation, is used in the 2D nonlinear response history analysis. Analysis is performed for a set of ground motions scaled to the design earthquake and to the maximum considered earthquake (MCE). At both the design earthquake and the MCE, the FB building develops large inelastic deformations and shear forces in the wall and large floor accelerations. At the MCE, four of the BI buildings experience nominally elastic response of the wall, with floor accelerations and shear forces being 0.25 to 0.55 times those experienced by the FB building. The response of the FB and four of the BI buildings to four unscaled historical pulse‐like near‐fault ground motions is also studied. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
There is no consensus at the present time regarding an appropriate approach to model viscous damping in nonlinear time‐history analysis of base‐isolated buildings because of uncertainties associated with quantification of energy dissipation. Therefore, in this study, the effects of modeling viscous damping on the response of base‐isolated reinforced concrete buildings subjected to earthquake ground motions are investigated. The test results of a reduced‐scale three‐story building previously tested on a shaking table are compared with three‐dimensional finite element simulation results. The study is primarily focused on nonlinear direct‐integration time‐history analysis, where many different approaches of modeling viscous damping, developed within the framework of Rayleigh damping are considered. Nonlinear direct‐integration time‐history analysis results reveal that the damping ratio as well as the approach used to model damping has significant effects on the response, and quite importantly, a damping ratio of 1% is more appropriate in simulating the response than a damping ratio of 5%. It is shown that stiffness‐proportional damping, where the coefficient multiplying the stiffness matrix is calculated from the frequency of the base‐isolated building with the post‐elastic stiffness of the isolation system, provides reasonable estimates of the peak response indicators, in addition to being able to capture the frequency content of the response very well. Furthermore, nonlinear modal time‐history analyses using constant as well as frequency‐dependent modal damping are also performed for comparison purposes. It was found that for nonlinear modal time‐history analysis, frequency‐dependent damping, where zero damping is assigned to the frequencies below the fundamental frequency of the superstructure for a fixed‐base condition and 5% damping is assigned to all other frequencies, is more appropriate, than 5% constant damping. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
Recent studies have indicated uncertainty about the performance limit states of seismically isolated buildings in very large earthquakes, especially if the isolator displacement demands exceed the seismic gap and induce pounding. Previous research has shown the benefit of providing phased supplemental damping that does not affect the isolation system response in a design event. A phased passive control device, or gap damper, was designed, fabricated, and experimentally evaluated during shake table testing of a quarter scale base‐isolated three‐story steel frame building. Identical input motions were applied to system configurations without a gap damper and with a gap damper, to directly assess the influence of the gap damper on displacement and acceleration demands. The gap damper was observed to reduce displacement demands by up to 15% relative to the isolated system without the gap damper. Superstructure floor accelerations increased substantially because of damper activation, but were limited to a peak of about 1.18 g. The gap damper reduces displacement most effectively if the ground motion contains one or more of the following characteristics: the spectral displacement increases with increasing period near the effective period of the isolation system, the motion is dominated by a single large pulse rather than multiple cycles at a consistent intensity, and the motion has a dominant component aligned with a major axis of the structure. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
A mechanism of horizontal floor response spectra amplification in the vicinity of higher modes' frequencies is investigated. It is demonstrated, by means of a simple two‐degrees‐of‐freedom model, that in the case of unsymmetrical superstructure, such amplification may occur because of the coupling between vertical excitation and horizontal response of the non‐isolated modes. This phenomenon is further illustrated by the results of analyses of a model of a nuclear plant. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
This paper presents a regression model to predict the base displacement responses of biaxial base‐isolated buildings using independent component analysis. The model proposed utilizes multiple ground motion intensity measures from North American and Japanese earthquakes as inputs, and transforms them into an independent component space using independent component regression (ICR). Unlike other latent variable methods, such as principal component regression, ICR does not readily allow for dimensionality reduction of the components that do not contribute significantly to the explained variance of the original data set. Hence, a whitening‐step to transform the correlated variables into uncorrelated ones is introduced prior to performing ICR. Prediction results are presented and compared with the simulation results for two building models with increasing degree of complexity. The results show that the model based on ICR results in good estimates for the base displacement responses, and the standard errors remain relatively small and constant across a range of isolation periods. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
It is clear that base isolation is a sensible strategic design in attenuating the responses of a structural system induced by ground motions. The design of seismically isolated structures is mainly governed by the Uniform Building Code (UBC) published by the International Conference of Building Officials. The UBC code emphasizes a simple, statically equivalent design method that displacements of an isolated structure are concentrated at the isolation level. Therefore, the superstructure nearly moves as a rigid body and the design forces of elements above isolators are based on the behaviour of isolators at the design displacement. However, in the UBC code, the distribution of inertial (or lateral) forces over the height of the superstructure above isolation has been found to be too conservative for most isolated structures. In view of this, two simple and reasonable design formulae for the lateral force distribution on isolated structures have been proposed in this paper. Results obtained from a full‐scale isolated structure tested on the shaking table and numerical analyses of two additional examples verify the suitability of design formulae. It is illustrated that the proposed formulae can predict well the lateral force distribution on isolated structures during earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

13.
An approximate method for linear analysis of asymmetric‐plan, multistorey buildings is specialized for a single‐storey, base‐isolated structure. To find the mode shapes of the torsionally coupled system, the Rayleigh–Ritz procedure is applied using the torsionally uncoupled modes as Ritz vectors. This approach reduces to analysis of two single‐storey systems, each with vibration properties and eccentricities (labelled ‘effective eccentricities’) similar to corresponding properties of the isolation system or the fixed‐base structure. With certain assumptions, the vibration properties of the coupled system can be expressed explicitly in terms of these single‐storey system properties. Three different methods are developed: the first is a direct application of the Rayleigh–Ritz procedure; the second and third use simplifications for the effective eccentricities, assuming a relatively stiff superstructure. The accuracy of these proposed methods and the rigid structure method in determining responses are assessed for a range of system parameters including eccentricity and structure flexibility. For a subset of systems with equal isolation and structural eccentricities, two of the methods are exact and the third is sufficiently accurate; all three are preferred to the rigid structure method. For systems with zero isolation eccentricity, however, all approximate methods considered are inconsistent and should be applied with caution, only to systems with small structural eccentricities or stiff structures. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

14.
This paper reports on the investigation of novel fiber reinforced elastomeric isolator (FREI) bearings, which do not have thick end plates, and are used in an unbonded application. Owing to the stable lateral load‐displacement response exhibited by the unbonded FREI bearings, the proposed bearings are referred to as stable unbonded (SU)‐FREIs. A shake table test program was conducted on a two‐story test‐structure having well‐defined elastic response characteristics. Compared with the results for the corresponding fixed base (FB) structure, the peak response values, distribution of lateral response throughout the height of the structure, and response time histories of the tested base isolated (BI) structure indicate that significantly improved response can be achieved. This study clearly indicates that SU‐FREI bearings can provide an effective seismic isolation system. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
Base isolation has been established as the seismic design approach of choice when it comes to protecting nonstructural contents. However, while this protection technology has been widely shown to reduce seismic demands on attached oscillatory equipment and contents (EC), its effectiveness in controlling the response of freestanding EC that are prone to sliding has not been investigated. This study examines the seismic behavior of sliding EC inside base‐isolated buildings subjected to broadband ground motions. The effect of isolation system properties on the response of sliding EC with various friction coefficients is examined. Two widely used isolation models are considered: viscously damped linear elastic and bilinear. The study finds isolation to be generally effective in reducing seismic demands on sliding EC, but it also exposes certain situations where isolation in fact increases demands on EC, most notably for low friction coefficients and high earthquake intensities. Damping at the isolation level is effective in controlling the EC sliding displacements, although damping over about 20% is found to be superfluous. The study identifies a physically motivated dimensionless intensity measure and engineering demand parameter for sliding equipment in base‐isolated buildings subjected to broadband ground motions. Finally, the paper presents easy‐to‐use design fragility curves and an example that illustrates how to use them. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
A series of full‐scale shaking table tests are conducted using the E‐Defense shaking table facility on a base‐isolated four‐story RC hospital structure. A variety of furniture items, medical appliances, and service utilities are placed on the hospital specimen in as realistic a manner as possible. Four ground motions are adopted, including recorded near‐fault ground motions and synthesized long‐period, long‐duration ground motions. The test results show that the base‐isolated system performed very effectively against near‐fault ground motions due to significant reduction in the floor acceleration response, and operability and functionality of the hospital service is improved significantly as compared with the case observed for the corresponding base‐fixed system. Against the long‐period ground motion, however, the hospital service is difficult to maintain, primarily because of the significant motion of furniture items and medical appliances supported by casters. Resonance accentuated large displacements and velocities on the floors of the base‐isolated system, which causes such furniture items and medical appliances to slide, sometimes more than 3 m, resulting in occasional collision with other furnitures or against the surrounding partition walls. It is notable that a key to maintaining the function of the medical facilities is to securely lock the casters of furniture and medical appliances. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
Pounding between adjacent bridge structures with insufficient separation distance has been identified as one of the primary causes of damage in many major earthquakes. It takes place because the closing relative movement is larger than the structural gap provided between the structures. This relative structural response is controlled not only by the dynamic properties of the participating structures but also by the characteristics of the ground excitations. The consequence of the spatial variation of ground motions has been studied by researchers; however, most of these studies were performed numerically. The objective of the present research is to experimentally evaluate the influence of spatial variation of ground motions on the pounding behaviour of three adjacent bridge segments. The investigation is performed using three shake tables. The input spatially varying ground excitations are simulated based on the New Zealand design spectra for soft soil, shallow soil and strong rock using an empirical coherency loss function. Results confirm that the spatially nonniform ground motions increase the relative displacement of adjacent bridge girders and pounding forces. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
The classical response spectrum method continues to be the most popular approach for designing base‐isolated buildings, therefore avoiding computationally expensive nonlinear time‐history analyses. In this framework, a new method for the seismic analysis and design of building structures with base isolation system (BIS) is formulated and numerically validated, which enables one to overcome the main shortcomings of existing techniques based on the response spectrum method. The main advantages are the following: first, reduced computational effort with respect to an exact complex‐valued modal analysis, which is obtained through a transformation of coordinates in two stages, both involving real‐valued eigenproblems; second, effective representation of the damping, which is pursued by consistently defining different viscous damping ratios for the modes of vibration of the coupled BIS‐superstructure dynamic system; and third, ease of use, because a convenient reinterpretation of the combination coefficients leads to a novel damping‐adjusted combination rule, in which just a single response spectrum is required for the reference value of the viscous damping ratio. The proposed approach is specifically intended for design situations where (i) the dynamic behaviour of seismic isolators can be linearised and (ii) effects of nonproportional damping, as measured by modal coupling indexes, are negligible in the BIS‐superstructure assembly. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
A damage detection algorithm of structural health monitoring systems for base‐isolated buildings is proposed. The algorithm consists of the multiple‐input multiple‐output subspace identification method and the complex modal analysis. The algorithm is applicable to linear and non‐linear systems. The story stiffness and damping as damage indices of a shear structure are identified by the algorithm. The algorithm is further tuned for base‐isolated buildings considering their unique dynamic characteristics by simplifying the systems to single‐degree‐of‐freedom systems. The isolation layer and the superstructure of a base‐isolated building are treated as separate substructures as they are distinctly different in their dynamic properties. The effectiveness of the algorithm is evaluated through the numerical analysis and experiment. Finally, the algorithm is applied to the existing 7‐story base‐isolated building that is equipped with an Internet‐based monitoring system. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

20.
A versatile, simulation‐based framework for risk assessment and probabilistic sensitivity analysis of base‐isolated structures is discussed in this work. A probabilistic foundation is used to address the various sources of uncertainties, either excitation or structural, and to characterize seismic risk. This risk is given, in this stochastic setting, by some statistics of the system response over the adopted probability models and stochastic simulation is implemented for its evaluation. An efficient, sampling‐based approach is also introduced for establishing a probabilistic sensitivity analysis to identify the importance of each of the uncertain model parameters in affecting the overall risk. This framework facilitates use of complex models for the structural system and the excitation. The adopted structural model explicitly addresses nonlinear characteristics of the isolators and of any supplemental dampers, and the effect of seismic pounding of the base to the surrounding retaining walls. An efficient stochastic ground motion model is also discussed for characterizing future near‐fault ground motions and relating them to the seismic hazard for the structural site. An illustrative example is presented that emphasizes the results from the novel probabilistic sensitivity analysis and their dependence on seismic pounding occurrences and on addition of supplemental dampers. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   