首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 890 毫秒
1.
With focusing of gamma rays in the nuclear-line energy regime starting to establish itself as a feasible and very promising approach for high-sensitivity γ-ray (line) studies of individual sources, optimizing the focal plane instrumentation for γ-ray lens telescopes is a prime concern. Germanium detectors offer the best energy resolution available at ∼2 keV FWHM at 1 MeV and thus constitute the detector of choice for a spectroscopy mission in the MeV energy range. Using a Compton detector focal plane has three advantages over monolithic detectors: additional knowledge about (Compton) events enhances background rejection capabilities, the inherently finely pixellated detector naturally allows the selection of events according to the focal spot size and position, and Compton detectors are inherently sensitive to γ-ray polarization. We use the extensive simulation and analysis package assembled for the ACT vision mission study to explore achievable sensitivities for different Ge Compton focal plane configurations as a first step towards determining an optimum configuration.CBW thanks the Townes Fellowship at UCB and NASA Grant NNG05WC28G for Support.  相似文献   

2.
On 1 June 2005, the prototype Nuclear Compton Telescope (NCT) flew on a high altitude balloon from Fort Sumner, New Mexico. NCT is a balloon-borne soft γ-ray (0.2–10 MeV) telescope for studying astrophysical sources of nuclear line emission and γ-ray polarization. Our program is designed to develop and test technologies and analysis techniques crucial for the Advanced Compton Telescope; however, our detector design and configuration is also well matched to the focal plane requirements for focusing Laue lenses. The NCT prototype utilizes two, 3D imaging germanium detectors (GeDs) in a novel, ultra-compact design optimized for nuclear line emission in the 0.5–2 MeV range. Our prototype flight provides a critical test of the novel detector technologies, analysis techniques, and background rejection procedures developed for high resolution Compton telescopes.  相似文献   

3.
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and γ-ray detection. However, a considerable amount of charge loss in these detectors results in a reduced energy resolution. We have achieved a significant improvement in the spectral properties by forming the Schottky junction on the Te side of the CdTe wafer. With the further reduction of leakage current by an adoption of guard ring structure, we have demonstrated a CdTe pixel detector with high energy resolution and full charge collection capabilty. The detector has a pixel size of a few mm and a thickness of 0.5 $-$ 1 mm. We apply this high resolution detector to a new silicon and CdTe Compton Camera which features high angular resolution. We also describe a concept of the stack detector which consists of many thin CdTe layers and provides sufficient efficiency for hard X-rays and gamma-rays up to several hundred keV maintaining good energy resolution. A narrow-FOV Compton telescope can be realized by installing a Si/CdTe Compton Camera inside the deep well of an active shield. This configuration is very suitable as focal plane detector for future focusing gamma-ray missions.  相似文献   

4.
MAX is a proposed Laue lens gamma-ray telescope taking advantage of Bragg diffraction in crystals to concentrate incident photons onto a distant detector. The Laue lens and the detector are carried by two separate satellites flying in formation. Significant effort is being devoted to studying different types of crystals that may be suitable for focusing gamma rays in two 100 keV wide energy bands centered on two lines which constitute the prime astrophysical interest of the MAX mission: the 511 keV positron annihilation line, and the broadened 847 keV line from the decay of 56Co copiously produced in Type Ia supernovae. However, to optimize the performance of MAX, it is also necessary to optimize the detector used to collect the source photons concentrated by the lens. We address this need by applying proven Monte Carlo and event reconstruction packages to predict the performance of MAX for three different Ge detector concepts: a standard coaxial detector, a stack of segmented detectors, and a Compton camera consisting of a stack of strip detectors. Each of these exhibits distinct advantages and disadvantages regarding fundamental instrumental characteristics such as detection efficiency or background rejection, which ultimately determine achievable sensitivities. We conclude that the Compton camera is the most promising detector for MAX in particular, and for Laue lens gamma-ray telecopes in general.  相似文献   

5.
X-ray polarimetry can be an important tool for investigating various physical processes as well as their geometries at the celestial X-ray sources. However, X-ray polarimetry has not progressed much compared to the spectroscopy, timing and imaging mainly due to the extremely photon-hungry nature of X-ray polarimetry leading to severely limited sensitivity of X-ray polarimeters. The great improvement in sensitivity in spectroscopy and imaging was possible due to focusing X-ray optics which is effective only at the soft X-ray energy range. Similar improvement in sensitivity of polarisation measurement at soft X-ray range is expected in near future with the advent of GEM based photoelectric polarimeters. However, at energies >10 keV, even spectroscopic and imaging sensitivities of X-ray detector are limited due to lack of focusing optics. Thus hard X-ray polarimetry so far has been largely unexplored area. On the other hand, typically the polarisation degree is expected to increase at higher energies as the radiation from non-thermal processes is dominant fraction. So polarisation measurement in hard X-ray can yield significant insights into such processes. With the recent availability of hard X-ray optics (e.g. with upcoming NuSTAR, Astro-H missions) which can focus X-rays from 5 KeV to 80 KeV, sensitivity of X-ray detectors in hard X-ray range is expected to improve significantly. In this context we explore feasibility of a focal plane hard X-ray polarimeter based on Compton scattering having a thin plastic scatterer surrounded by cylindrical array scintillator detectors. We have carried out detailed Geant4 simulation to estimate the modulation factor for 100 % polarized beam as well as polarimetric efficiency of this configuration. We have also validated these results with a semi-analytical approach. Here we present the initial results of polarisation sensitivities of such focal plane Compton polarimeter coupled with the reflection efficiency of present era hard X-ray optics.  相似文献   

6.
The degree of linear polarization in solar flares has not yet been precisely determined despite multiple attempts to measure it with different missions. The high energy range, in particular, has very rarely been explored, due to its greater instrumental difficulties. We approached the subject using the Reuven Ramaty High Energy Spectroscopic Imager (RHESSI) satellite to study six X-class and 1 M-class flares in the energy range between 100 and 350 keV. Using RHESSI as a polarimeter requires the application of strict cuts to the event list in order to extract those photons that are Compton scattered between two detectors. Our measurements show polarization values between 2 and 54%, with errors ranging from 10 to 26% in 1σ level. In view of the large uncertainties in both the magnitude and direction of the polarization vector, the results can only reject source models with extreme properties.  相似文献   

7.
We investigate the effects of inverse Compton scattering by electrons and positrons in the unshocked winds of rotationally-powered binary pulsars. This process can scatter low energy target photons to produce gamma rays with energies from MeV to TeV. The binary radio pulsars PSR B1259−63 and PSR J0045−73 are both in close eccentric orbits around bright main sequence stars which provide a huge density of low energy target photons. The inverse Compton scattering process transfers momentum from the pulsar wind to the scattered photons, and therefore provides a drag which tends to decelerate the pulsar wind. We present detailed calculations of the dynamics of a pulsar wind which is undergoing inverse Compton scattering, showing that the deceleration of the wind of PSR B1259−63 due to ‘inverse Compton drag' is small, but that this process may confine the wind of PSR J0045−73 before it attains pressure balance with the outflow of its companion star. We calculate the spectra and light curves of the resulting inverse Compton emission from PSR B1259−63 and show that if the size of the pulsar wind nebula is comparable to the binary separation, then the γ-ray emission from the unshocked wind may be detectable by atmospheric Cherenkov detectors or by the new generation of satellite-borne γ-ray detectors such as INTEGRAL and GLAST. This mechanism may therefore provide a direct probe of the freely-expanding regions of pulsar winds, previously thought to be invisible.  相似文献   

8.
Comptonγ射线望远镜COMPTEL/CGRO工作于0.75-30MeV能区,本文应用直接解调方法分析CGRO#1观测的COMPTEL数据,准确定出Crabγ射线源的位置,在10-30MeV能区,分辨开最大似然法所不能完全分辨的Crabγ射线源和类星体PKS0528+134,得出优于传统成像方法所得的成像结果.应用直接成像方法处理γ射线脉冲星Geminga分位相数据,发现Geminga在10-30MeV能区仍存在辐射,辐射集中在Geminga第一个峰的位相区域.结果表明,应用直接解调方法对Compton望远镜数据作成像分析是完全可行的  相似文献   

9.
For conventional radiation detectors fabricated from compound semi-conductors, the wide disparity between the transport properties of the electron and holes, means that detector performances are limited by the carrier with the poorest mobility-lifetime product (μτ). Finite drift lengths introduce an energy dependent depth term into the charge collection process, which effectively limit maximum detection volume to tens of mm3 – entirely unsuitable for the detection of gamma-rays. The recent introduction of the coplanar-grid charge-sensing techniques has overcome this problem by essentially discarding the carrier with the poorest transport properties, thus permitting high spectral resolution and high detection efficiency. For example, energy resolutions of 2% full-width half-maximum at 662 keV have been demonstrated with coplanar-grid CdZnTe detectors of volumes up to 2 cm3. Further improvements in detector performance and yield are being pursued through refinements in electrode design and material quality. Because coplanar-grid CdZnTe detectors can operate at room temperature, they are ideally suited for applications requiring portability, small size, or low power consumption such as planetary space missions. Other potential applications include well logging, medical diagnostics, and gamma-ray astronomy. We discuss the feasibility and design of a solid state gamma-ray detector based on CdZnTe and compare its performance to a large volume Ge detector. As will be shown, a significant improvement can be made if T1Br is used as the detection medium.  相似文献   

10.
X-ray transition radiation can be used to measure the Lorentz factor of relativistic particles. At energies approaching γ=E/mc2=105, transition radiation detectors can be optimized by using thick (5–10 mil) foils with large (5–10 mm) spacings. This implies X-ray energies 100 keV and the use of scintillators as the X-ray detectors. Compton scattering of the X-rays out of the particle beam then becomes an important effect. We discuss the design of very high energy detectors, the use of metal radiator foils rather than the standard plastic foils, inorganic scintillators for detecting Compton scattered transition radiation, and the application to the ACCESS cosmic ray experiment.  相似文献   

11.
The search for γ-ray bursts of low intensity has been undertaken mostly from balloon-borne detectors with wide aperture. The effect of multiple Compton scattering in the atmosphere greatly increases the probability of seeing small bursts, and should be taken into account when deducing the lnN-lnS curve. Detailed calculations have been carried out for different assumed spectra in the extreme case of a completely unscreened flat horizontal detector.  相似文献   

12.
McConnell  Mark L.  Ryan  James M.  Smith  David M.  Lin  Robert P.  Emslie  A. Gordon 《Solar physics》2002,210(1-2):125-142
Although designed primarily as a hard X-ray imager and spectrometer, the Ramaty High-Energy Solar Spectroscopic Imager (RHESSI) is also capable of measuring the polarization of hard X-rays (20–100 keV) from solar flares. This capability arises from the inclusion of a small unobstructed Be scattering element that is strategically located within the cryostat that houses the array of nine germanium detectors. The Ge detectors are segmented, with both a front and rear active volume. Low-energy photons (below about 100 keV) can reach a rear segment of a Ge detector only indirectly, by scattering. Low-energy photons from the Sun have a direct path to the Be and have a high probability of Compton scattering into a rear segment of a Ge detector. The azimuthal distribution of these scattered photons carries with it a signature of the linear polarization of the incident flux. Sensitivity estimates, based on Monte Carlo simulations and in-flight background measurements, indicate that a 20–100 keV polarization sensitivity of less than a few percent can be achieved for X-class flares.  相似文献   

13.
Spectroscopic observation of solar flares in the hard X-ray energy range, particularly the 20 ∼ 100 keV region, is an invaluable tool for investigating the flare mechanism. This paper describes the design and performance of a balloon-borne hard X-ray spectrometer using CdTe detectors developed for solar flare observation. The instrument is a small balloon payload (gondola weight 70 kg) with sixteen 10×10×0.5 mm CdTe detectors, designed for a 1-day flight at 41 km altitude. It observes in an energy range of 20−120 keV and has an energy resolution of 3 keV at 60 keV. The second flight on 24 May 2002 succeeded in observing a class M1.1 flare.  相似文献   

14.
We present the first results from the low-energy detector payload of the solar X-ray spectrometer (SOXS) mission, which was launched onboard the GSAT-2 Indian spacecraft on May 08, 2003 by the GSLV-D2 rocket to study solar flares. The SOXS low-energy detector (SLD) payload was designed, developed, and fabricated by the Physical Research Laboratory (PRL) in collaboration with the Space Application Centre (SAC), Ahmedabad and the Indian Space Research Organization (ISRO) Satellite Centre (ISAC), Bangalore. The SLD payload employs state-of-the-art, solid-state detectors, viz., Si PIN and Cadmium-Zinc-Telluride (CZT) devices that operate at near room temperature (−20 °C). The energy ranges of the Si PIN and CZT detectors are 4 – 25 and 4 – 56 keV, respectively. The Si PIN provides sub-keV energy resolution, while the CZT provides ~1.7 keV energy resolution throughout the energy range. The high sensitivity and sub-keV energy resolution of the Si PIN detector allows measuring the intensity, peak energy, and the equivalent width of the Fe-line complex at approximately 6.7 keV, as a function of time in all ten M-class flares studied in this investigation. The peak energy (E p) of the Fe-line feature varies between 6.4 and 6.7 keV with increase in temperature from 9 to 58 MK. We found that the equivalent width (w) of the Fe-line feature increases exponentially with temperature up to 30 MK and then increases very slowly up to 40 MK. It remains between 3.5 and 4 keV in the temperature range of 30 – 45 MK. We compare our measurements of w with calculations made earlier by various investigators and propose that these measurements may improve theoretical models. We interpret the variation of both E p and w with temperature as being to the changes in the ionization and recombination conditions in the plasma during the flare, and as a consequence, the contribution from different ionic emission lines also varies.  相似文献   

15.
The polarisation of astrophysical source emission in the energy range from a few tens of keV up to the MeV region is an almost unexplored field of high-energy astrophysics. Till date, polarimetry in astrophysics–in the energy domain from hard X-rays up to soft γ-rays–has not been pursued due to the difficulties involved in obtaining sufficient sensitivity. Indeed for those few instruments that are capable of performing this type of measurement (e.g. the COMPTEL instrument on the Compton Gamma-ray Observatory and the IBIS instrument on INTEGRAL), polarimetry itself plays a secondary role in the mission objectives, as the efficiencies (0.5% and 10% maximum, respectively) and polarimetric Q factors (0.1 and 0.3, respectively) are relatively limited. In order to perform efficient polarimetric measurements for hard X-ray and soft gamma-ray sources, with an instrument of relatively robust and simple design, a CdTe based telescope (CIPHER: Coded Imager and Polarimeter for High Energy Radiation) is under study. This instrument is based on a thick (10 mm) CdTe position-sensitive spectrometer comprising four modules of 32 × 32 individual pixels, each with a surface area of 2 × 2 mm2 (about 160 cm2 total detection area). The polarimetric performance and design optimisation of the CIPHER detection surface have been studied by use of a Monte Carlo code. This detector, due to its intrinsic geometry, can allow efficient polarimetric measurements to be made between 100 keV and 1 MeV. In order to predict the polarimetric performance and to optimise the design and concept of the CIPHER detection plane, a Monte Carlo code based on GEANT4 library modules was developed to simulate the detector behaviour under a polarised photon flux. The Compton double event efficiency, as well bi-dimensional double event distribution maps and the corresponding polarimetric modulation factor will be presented and discussed. Modulation Q factors better than 0.50 and double event total efficiencies greater than 10% were calculated in the energy range between 100 keV and 1 MeV. Herein we will present and discuss the general problems that affect polarimetric measurements in space, such as the inclination of the source with respect to the telescope optical axis and background radiation. Q factor calculations for several beam inclinations as well as for background together with simulated astronomical sources will be presented and discussed.  相似文献   

16.
Propagation of UHE protons through CMB radiation leaves the imprint on energy spectrum in the form of Greisen–Zatsepin–Kuzmin (GZK) cutoff, bump (pile-up protons) and dip. The dip is a feature in energy range 1×1018–4×1019 eV, caused by electron-positron pair production on CMB photons. Calculated for power-law generation spectrum with index γ g =2.7, the shape of the dip is confirmed with high accuracy by data of Akeno—AGASA, HiRes, Yakutsk and Fly’s Eye detectors. The predicted shape of the dip is robust: it is valid for the rectilinear and diffusive propagation, for different discretenesses in the source distribution, for local source overdensity and deficit etc. This property of the dip allows us to use it for energy calibration of the detectors. The energy shift λ for each detector is determined by minimum χ 2 in comparison of observed and calculated dip. After this energy calibration the absolute fluxes, measured by AGASA, HiRes and Yakutsk detectors remarkably coincide in energy region 1×1018–1×1020 eV. Below the characteristic energy E c ≈1×1018 eV the spectrum of the dip flattens for both diffusive and rectilinear propagation, and more steep galactic spectrum becomes dominant at E<E c . The energy of transition E tr<E c approximately coincides with the position of the second knee E 2kn , observed in the cosmic ray spectrum. The dip-induced transition from galactic to extragalactic cosmic rays at the second knee is compared with traditional model of transition at ankle, the feature observed at energy ∼1×1019 eV.   相似文献   

17.
X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard X-ray polarimetry is more rewarding because the sources are expected to be intrinsically highly polarized at higher energies. With the successful implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive Compton polarimeters as focal plane detectors. Such a configuration is likely to provide sensitive polarization measurements in hard X-rays with a broad energy band. We are developing a focal plane hard X-ray Compton polarimeter consisting of a plastic scintillator as active scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and 100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons scattered by the plastic scatterer are collected by a cylindrical array of 16 CsI(Tl) scintillators (5 mm × 5 mm × 150 mm) which are read by Si Photomultiplier (SiPM). Use of the new generation SiPMs ensures the compactness of the instrument which is essential for the design of focal plane detectors. The expected sensitivity of such polarimetric configuration and complete characterization of the plastic scatterer, specially at lower energies have been discussed in [11, 13]. In this paper, we characterize the CsI(Tl) absorbers coupled to SiPM. We also present the experimental results from the fully assembled configuration of the Compton polarimeter.  相似文献   

18.
Astrosat is the first Indian satellite mission dedicated for astronomical studies. It is planned for launch during 2014 and will have five instruments for multi-wavelength observations from optical to hard X-rays. Cadmium Zing Telluride Imager (CZTI) is one of the five instruments aiming for simultaneous X-ray spectroscopy and imaging in the energy range of 10 keV to 100 keV (along with all sky photometric capability unto 250 keV). It is based on pixilated CZT detector array with total geometric area of 1024 cm2. It will have two-dimensional coded mask for medium resolution X-ray imaging. The CZT detector plane will be realized using CZT detector modules having integrated readout electronics. Each CZT detector module consists of 4 cm × 4 cm CZT with thickness of 5 mm which is further pixilated into 16 × 16 array of pixels. Thus each pixel has size of 2.5 mm × 2.5 mm and thickness of 5 mm. Such pixilated detector plane can in principle be used for hard X-ray polarization measurements based on the principle of Compton scattering by measuring azimuthal distribution of simultaneous events in two adjacent pixels. We have carried out detailed Geant4 simulations for estimating polarimetric capabilities of CZTI detector plane. The results indicate that events in the energy range of 100 keV to 250 keV, where the 5 mm thick CZT detector has significant detection efficiency, can be used for polarimetric studies. Our simulation results indicate the minimum detectable polarization (MDP) at the level of ~ 10% can be achieved for bright Crab like X-ray sources with exposure time of ~500 ks. We also carried out preliminary experiments to verify the results from our simulations. Here we present detailed method and results of our simulations as well as preliminary results from the experimental verification of polarimetric capabilities of CZT detector modules used in Astrosat CZTI.  相似文献   

19.
We present a study of 10 microflares observed in 4–30 keV by SOXS mission simultaneously with Hα observations made at NAOJ, Japan during the interval between February and August 2004. The X-ray and Hα light curves showed that the lifetime of microflares varies between 4 and 25 min. We found that the X-ray emission in all microflares under study in the dynamic energy range of 4–30 keV can be fitted by thermal plus non-thermal components. The thermal spectrum appeared to start from almost 4 keV, low level discriminator (LLD) of both Si and CZT detectors, however it ends below 8 keV. We also observed the Fe line complex features at 6.7 keV in some microflares and attempted to fit this line by isothermal temperature assumption. The temperature of isothermal plasma of microflares varies in the range between 8.6 and 10.1 MK while emission measure between 0.5 and 2x1049 cm-3. Non-thermal (NT) emission appeared in the energy range 7–15 keV with exponent -6.8 ≤γ-4.8. Our study of microflares that had occurred on 25 February 2004 showed that sometimes a given active region produces recurrent microflare activity of a similar nature. We concluded from X-ray and simultaneous Hα observations that the microflares are perhaps the result of the interaction of low lying loops. It appears that the electrons that accelerated during reconnection heat the ambient coronal plasma as well as interact with material while moving down along the loops and thereby produce Hα bright kernels.  相似文献   

20.
We present the first results from the ‘Low Energy Detector’ pay-load of ‘Solar X-ray Spectrometer (SOXS)’ mission, which was launched onboard GSAT-2 Indian spacecraft on 08 May 2003 by GSLV-D2 rocket to study the solar flares. The SOXS Low Energy Detector (SLD) payload was designed, developed and fabricated by Physical Research Laboratory (PRL) in collaboration with Space Application Centre (SAC), Ahmedabad and ISRO Satellite Centre (ISAC), Bangalore of the Indian Space Research Organization (ISRO). The SLD payload employs the state-of-the-art solid state detectors viz., Si PIN and Cadmium-Zinc-Telluride (CZT) devices that operate at near room temperature (-20°C). The dynamic energy range of Si PIN and CZT detectors are 4–25 keV and 4–56 keV respectively. The Si PIN provides sub-keV energy resolution while CZT reveals ∼1.7keV energy resolution throughout the dynamic range. The high sensitivity and sub-keV energy resolution of Si PIN detector allows the measuring of the intensity, peak energy and equivalent width of the Fe-line complex at approximately 6.7 keV as a function of time in all 8 M-class flares studied in this investigation. The peak energy (E p) of Fe-line feature varies between 6.4 and 6.8 keV with increase in temperature from 9 to 34 MK. We found that the equivalent width (ω) of Fe-line feature increases exponentially with temperature up to 20 MK but later it increases very slowly up to 28 MK and then it remains uniform around 1.55 keV up to 34 MK. We compare our measurements ofw with calculations made earlier by various investigators and propose that these measurements may improve theoretical models. We interpret the variation of both Epand ω with temperature as the changes in the ionization and recombination conditions in the plasma during the flare interval and as a consequence the contribution from different ionic emission lines also varies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号