首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
通过钢筋混凝土构件的动态试验,研究不同加载速率下的钢筋混凝土梁柱力学特性。考虑屈服强度、极限强度和刚度的动力效应,引入损伤因子,并考虑混凝土损伤对卸载刚度的影响,建立了钢筋混凝土构件率相关的三折线恢复力模型。利用有限元分析软件模拟钢筋混凝土构件的动态试验,对比模拟结果与试验结果得出:考虑应变率效应和混凝土损伤对卸载刚度的影响,能够更好地反映构件的动力特性。对一平面框架结构模型进行不同加载速率下的动态分析,研究加载速率对结构动力反应的影响,结果表明,随着加载速率的增大,结构模型各构件的强度和刚度增大,结构模型整体抗侧移刚度增强,水平位移减小。  相似文献   

2.
为探索非一致地震波动输入对大型钢筋混凝土框架结构地震响应的影响,基于OpenSees软件平台建立二维钢筋混凝土框架结构\|地基动力相互作用有限元模型。将El-Centro地震波按P波波形分别以0°、15°、30°和35°角入射该有限元模型进行计算,对比分析框架柱内力和楼层层间位移的地震响应。研究发现非一致地震波输入方法对于大型钢筋混凝土框架结构建筑动力响应影响明显,随着地震波入射角的增大,钢筋混凝土框架结构底层柱的轴力幅值减小,剪力幅值增大,而弯矩幅值变化较小,楼层层间位移幅值也随之增大。研究结果对于大型钢筋混凝土框架结构抗震设计具有参考意义。  相似文献   

3.
This paper presents a new type of structural bracing intended for seismic retrofitting use in framed structures. This special composite brace,termed glass-fiber-reinforced-polymer(GFRP)-tube-confined-concrete composite brace,is comprised of concrete confined by a GFRP tube and an inner steel core for energy dissipation.Together with a contribution from the GFRP-tube confined concrete,the composite brace shows a substantially increased stiffness to control story drift, which is often a preferred feature in seismic retrofitting.An analysis model is established and implemented in a general finite element analysis program-OpenSees,for simulating the load-displacement behavior of the composite brace.Using this model,a parametric study of the hysteretic behavior(energy dissipation,stiffness,ductility and strength)of the composite brace was conducted under static cyclic loading and it was found that the area ratio of steel core to concrete has the greatest influence among all the parameters considered.To demonstrate the application of the composite brace in seismic retrofitting, a three-story nonductile reinforced concrete(RC)frame structure was retrofitted with the composite braces.Pushover analysis and nonlinear time-history analyses of the retrofitted RC frame structure was performed by employing a suite of 20 strong ground motion earthquake records.The analysis results show that the composite braces can effectively reduce the peak seismic responses of the RC frame structure without significantly increasing the base shear demand.  相似文献   

4.
地震作用后钢筋混凝土框架结构恢复性模拟研究   总被引:1,自引:1,他引:0       下载免费PDF全文
陈竣  罗凡 《地震工程学报》2019,41(3):568-573
钢筋混凝土框架结构在地震冲击后,其刚体退化特性复杂,存在模拟时结果失真明显的问题。为此,在考虑刚度退化规律的基础上进行分析模拟,研究地震冲击下钢筋混凝土框架结构的恢复性。提取地震作用下钢筋混凝土框架结构滞回曲线,通过有限元分析获取不同的特征点,形成恢复力模型的骨架曲线;依据恢复力模型骨架曲线和刚度退化规律,构建滞回曲线,模拟地震作用后钢筋混凝土框架结构恢复过程。在模拟的钢筋混凝土框架结构恢复实验中,层间位移结果低于5 mm、层间绝对加速度和柱底抬升结果的误差均低于0.1 mm;模拟得到结构的弯矩缝隙都能够实现闭合,钢筋混凝土结构未出现屈服现象,说明模拟的结果较好。  相似文献   

5.
Damage to building structures due to underground blast‐induced ground motions is a primary concern in the corresponding determination of the safe inhabited building distance (IBD). Because of the high‐frequency nature of this category of ground motions and especially the presence of significant vertical component, the characteristics of structural response and damage differ from those under seismic type low‐frequency ground motions. This paper presents a numerical investigation aimed at evaluating reinforced concrete (RC) structure damage generated by underground blast‐induced ground excitation. In the numerical model, two damage indices are proposed to model reinforced concrete failure. A fracture indicator is defined to track the cracking status of concrete from micro‐ to macrolevel; the development of a plastic hinge due to reinforcement yielding is monitored by a plastic indicator; while the global damage of the entire structure is correlated to structural stiffness degradation represented by its natural frequency reduction. The proposed damage indices are calibrated by a shaking table test on a 1: 5‐scale frame model. They are then applied to analyse the structural damage to typical low‐ to high‐rise RC frames under blast‐induced ground motions. Results demonstrate a distinctive pattern of structural damage and it is shown that the conventional damage assessment methods adopted in seismic analysis are not applicable here. It is also found that the existing code regulation on allowable peak particle velocity of blast‐induced ground motions concerning major structural damage is very conservative for modern RC structures. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

6.
张家广  吴斌  梅洋 《地震学刊》2014,(5):637-642
提出了一种既有钢筋混凝土框架结构的抗震加固方法,该法采用防屈曲支撑提高框架结构体系的水平承载力和耗能能力,利用外包钢进一步提高柱子的抗弯和抗剪承载力。采用开源有限元程序OpenSees,分别建立空钢筋混凝土框架和防屈曲支撑加固钢筋混凝土框架的分析模型,对2榀钢筋混凝土框架的抗震性能进行模拟。防屈曲支撑采用了弹塑性桁架单元模型,加固框架柱混凝土考虑了外包钢的约束作用。将分析结果与拟静力试验结果进行比较,以检验分析模型的准确性,以及研究防屈曲支撑和外包钢对混凝土框架抗震性能的影响。分析结果表明,数值模拟与试验结果吻合较好,验证了基于OpenSees建立的数值模型的准确性;外包钢有效改善了框架柱的抗弯承载力和变形能力;防屈曲支撑显著提高了加固框架体系的水平刚度、水平承载力和耗能能力。  相似文献   

7.
This paper describes an analytical investigation on a reinforced concrete lateral load resisting structural system comprising a pin‐supported (base‐rocking) shear wall coupled with a moment frame on 1 or both sides of the wall. Yielding dampers are used to provide supplemental energy dissipation through the relative displacements at the vertical connections between the wall and the frames. The study extends a previous linear‐elastic model for pin‐supported wall‐frame structures by including the effects of the dampers. A closed‐form solution of the lateral load behavior of the structure is derived by approximating the discrete wall‐frame‐damper interactions with distributed (ie, continuous) properties. The validity of the model is verified by comparing the closed‐form results with computational models using OpenSees program. Then, a parametric analysis is conducted to investigate the effects of the wall, frame, and damper stiffness on the behavior of the structure. It is found that the damper stiffness significantly affects the distribution of shear forces and bending moments over the wall height. Finally, the performance‐based plastic design approach extended to the wall‐frame‐damper system is proposed. Case studies are carried out to design 2 damped pin‐supported wall‐frame structures using the proposed approach. Nonlinear dynamic time‐history analyses are conducted to verify the effectiveness of this method. Results indicate that the designed structures can achieve the performance level with the story drift ratios less than target values, and weak‐story failure mechanism is not observed. The approach can be used in engineering applications.  相似文献   

8.
基于OpenSees的CFRP加固RC短柱抗震性能数值模拟   总被引:3,自引:1,他引:2  
采用地震工程开源模拟软件OpenSees对CFRP加固RC短柱进行了静力Push over分析和低周往复加载分析,并与通用有限元软件ANSYS模拟结果进行对比研究.研究结果表明:利用CFRP进行加固,不仅阻止了RC短柱的脆性剪切破坏,而且使破坏模式转化为延性弯曲破坏,增强了结构延性,进而有效地提高其抗震性能;同ANSYS相比,OpenSees可以宏观的反映CFRP与混凝土共同作用的非线性力学特征,有效地对构件和结构进行加固后的承载力及抗震性能分析.  相似文献   

9.
This study assesses the seismic performance of a hybrid coupled wall (HCW) system with replaceable steel coupling beams (RSCBs) at four intensities of ground motion shaking. The performance of the HCW system is benchmarked against the traditional reinforced concrete coupled wall (RCW). Nonlinear numerical models are developed in OpenSees for a representative wall elevation in a prototype 11‐story building designed per modern Chinese codes. Performance is assessed via nonlinear dynamic analysis. The results indicate that both systems can adequately meet code defined objectives in terms of global and component behavior. Behavior of the two systems is consistent under service level earthquakes, whereas under more extreme events, the HCW system illustrates enhanced performance over the RCW system resulting in peak interstory drifts up to 31% lower in the HCW than the RCW. Larger drifts in the RCW are because of reduced coupling action induced by stiffness degradation of RC coupling beams, whereas the stable hysteretic responses and overstrength of RSCBs benefit post‐yield behavior of the HCW. Under extreme events, the maximum beam rotations of the RSCBs are up to 42% smaller than those of the RC coupling beams. Moderate to severe damage is expected in the RC coupling beams, whereas the RSCBs sustain damage to the slab above the beam and possible web buckling of shear links. The assessment illustrates the benefits of the HCW with RSCBs over the RCW system, because of easy replacement of the shear links as opposed to costly and time‐consuming repairs of RC coupling beams. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
The steel reinforced concrete (SRC) wall consists of structural steel embedded at the boundary elements of a reinforced concrete (RC) wall. The use of SRC walls has gained popularity in the construction of high‐rise buildings because of their superior performance over conventional RC walls. This paper presents a series of quasi‐static tests used to examine the behavior of SRC walls subjected to high axial force and lateral cyclic loading. The SRC wall specimens showed increased flexural strength and deformation capacity relative to their RC wall counterpart. The flexural strength of SRC walls was found to increase with increasing area ratio of embedded structural steel, while the section type of embedded steel did not affect the wall's strength. The SRC walls under high axial force ratio had an ultimate lateral drift ratio of approximately 1.4%. In addition, a multi‐layer shell element model was developed for the SRC walls and was implemented in the OpenSees program. The numerical model was validated through comparison with the test data. The model was able to predict the lateral stiffness, strength and deformation capacities of SRC walls with a reasonable level of accuracy. Finally, a number of issues for the design of SRC walls are discussed, along with a collection and analysis of the test data, including (1) evaluation of flexural strength, (2) calculation of effective flexural stiffness, and (3) inelastic deformation capacity of SRC walls. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
绝大多数针对极端作用下的结构连续倒塌分析,在分析过程中不能实时地根据构件的损伤状态对分析模型进行修改,也不能考虑连续倒塌过程中的各种碰撞问题。连续倒塌过程中发生的碰撞对结构响应预测有重大影响。本文依据钢筋混凝土框架结构发生梁-梁碰撞的机理,基于OpenSees平台建模,结合Matlab的混合编程计算碰撞力,通过添加碰撞时程力并对结构进行模型更新,合理地实现钢筋混凝土框架结构在强震作用下的连续倒塌过程中发生梁-梁碰撞的具体过程。将得到的结果和传统时程分析法的结果进行的对比表明,结合Matlab和OpenSees命令可以实时地计算碰撞力序列和对结构进行更新,梁-梁碰撞和构件的逐步失效使结构的水平位移和转角有一定的增大,竖向位移有一定减小。  相似文献   

12.
A three‐dimensional beam–truss model (BTM) for reinforced concrete (RC) walls that explicitly models flexure–shear interaction and accurately captures diagonal shear failures was presented in the first part of this two‐paper series. This paper extends the BTM to simulate RC slabs and coupled RC walls through slabs and beams. The inclination angle of the diagonal elements for coupled RC walls is determined, accounting for the geometry of the walls and the level of coupling. Two case studies validate the model: (1) a two‐bay slab–column specimen experimentally tested using cyclic static loading and (2) a five‐story coupled T‐wall–beam–slab specimen subjected to biaxial shake table excitation. The numerically computed lateral force–lateral displacement and strain contours are compared with the experimentally measured response and observed damage. The five‐story specimen is characterized by diagonal shear failure at the bottom story of the walls, which is captured by the BTM. The BTM of the five‐story specimen is used to study the effects of coupling on shear demand for lightly reinforced RC coupled walls. The effect of mesh refinement and bar fracture of non‐ductile transverse reinforcement is studied. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
This paper presents results from a numerical investigation into the seismic retrofit of a soft story frame using a novel gapped‐inclined brace (GIB) system. The GIB system consists of a pinned brace and a gap element that is added to the first story columns of the frame. The inclusion of GIB elements in addition to increasing the lateral capacity of columns at the first story increases the post‐yield stiffness ratio of the system and reduces the P‐delta effects on the columns, while not increasing the first story lateral resistance or stiffness. This allows for the isolating benefits of the soft story to protect the upper floors of the structure from damage while avoiding excessive deformations and reducing the propensity for collapse. A six‐story RC frame with masonry infills on all floors except for the first floor is studied. The dynamic response of the retrofitted building using the GIB system is investigated numerically and is compared with the response of the original un‐retrofitted building and the same building in which masonry infills are added to the first story to mitigate the soft story response. Results from the nonlinear time‐history analyses indicate that the GIB system could provide a reliable seismic retrofit mechanism for soft story buildings, which greatly reduces the likelihood of collapse by increasing the displacement capacity of the soft storey and by reducing P‐delta effects, while minimizing the overall damage and losses in the building by taking advantages of the isolation that is provided by the soft story to the rest of the structure located above. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
Widely used damage indices, such as ductility and drift ratios, do not account for the influences of the duration of strong shaking, the cumulative inelastic deformation or energy dissipation in structures. In addition, the formulation and application of most damage indices have until now been based primarily on flexural modes of failure. However, evidence from earthquakes suggests that shear failure or combined shear‐flexure behavior is responsible for a large proportion of failures. Empirical considerations have been made in this paper for evaluating structural damage of low‐rise RC walls under earthquake ground motions by means of a new energy‐based low‐cycle fatigue damage index. The proposed empirical damage index is based on the results of an experimental program that comprised six shake table tests of RC solid walls and walls with openings; results of six companion walls tested under QS‐cyclic loading were used for comparison purposes. Variables studied were the wall geometry, type of concrete, web shear steel ratio, type of web shear reinforcement, and testing method. The index correlates the stiffness degradation and the destructiveness of the earthquake in terms of the duration and intensity of the ground motions. The stiffness degradation model considers simultaneously the increment of damage associated to the low‐cycle fatigue, energy dissipation, and the cumulative cyclic parameters, such as displacement demand and hysteretic energy dissipated. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
为明晰中空暗缝RC剪力墙抗剪机理和滞回性能,进行1榀1∶3缩尺单层、单跨中空暗缝RC剪力墙板拟静力试验,得到了试件破坏模式、滞回曲线、骨架曲线、刚度退化、强度退化、延性和耗能能力。通过数值模拟分析了混凝土强度、中空暗缝厚度、缝间墙配筋率对剪力墙板水平抗剪承载力的影响。研究结果表明:试件滞回曲线呈捏缩状,耗能能力一般,但具有较好的剪切变形能力;试件最终呈中空暗缝剪碎、缝间墙两端形成弯曲塑性铰的破坏模式;随着混凝土强度的提高和中空暗缝厚度的减小,试件水平抗剪承载力呈增加趋势;缝间墙配筋率对试件水平抗剪承载力及损伤状态的影响较小。  相似文献   

16.
通过有限元软件OpenSees对采用了T型钢锚固型节点的一个两层三跨屈曲约束支撑混凝土框架进行了模拟,并与试验结果对比,来验证模拟结果的准确性。在此基础上,对试验框架的原屈曲约束支撑结构体系进行抗震性能分析。结果表明:有限元分析结果与试验结果吻合良好,OpenSees可以准确的模拟屈曲约束支撑混凝土框架的受力性能;屈曲约束支撑混凝土框架具有良好的耗能性与水平承载力;屈曲约束支撑框架体系具有较好的抗震性能;屈曲约束支撑能够增加结构体系的侧向刚度,有效控制结构变形。  相似文献   

17.
验证研究新型多层钢管混凝土柱-铰接钢梁-混凝土核心筒结构的震损和反应特点。制作9层1/40的缩尺模型进行振动台测试,调查结构的震损特点、动力特性和地震反应。结果表明:震损出现在楼板与钢管混凝土柱、核心筒以及钢梁连接处的楼板上,震损破坏为变形引起的连接构造破坏和结构性破坏;自振周期随震损增加而增大,动力放大效应减小,侧向变形和层间位移显著增大;结构平均最大层间位移角超过规范框架-核心筒结构不倒塌限值的4.08倍而未出现倒塌;外排架抗扭刚度小,结构扭转反应由核心筒主导;相对于超高层结构,多层结构的剪重比显著增大,未出现因倾覆力矩过大而导致核心筒破坏的情况,较大层间位移角与损伤破坏的相关性提高。  相似文献   

18.
本文用钢管混凝土柱作为结构底层耗能柱、用承重墙和隔震器控制结构底层倒塌破坏,从而提出了一种新的耗能-隔震柔性底层结构体系。通过本文12根钢管混凝土柱和文献[7]中7根钢管混凝土柱的低周疲劳实验,初步确定了钢管混凝土柱地震损伤模型的参数;通过两个钢管混凝土-钢筋混凝土三层框架模型和一个纯钢筋混凝土三层框架模型的拟动力实验,研究和比较了两类结构体系的地震损伤。  相似文献   

19.
本文通过一座三层的耗能-隔震柔性底层钢管混凝土结构模型和一座三层普通钢筋混凝上结构模型的振动台实验,着重研究了耗能-隔震柔性底层钢管混凝上结构的抗震性能和减震效果,并与普通的钢筋混凝土结构的实验进行了分析比较,研究了两种结构体系在地震作用下的耗能分布和地震累积损伤情况。实验结果表明,耗能-隔震柔性底层能够有效地吸收地震输入的大部分能量,防止和减小了上部结构的地震破坏.文中还讨论了耗能-隔震柔性底层结构中钢管混凝土柱与橡胶隔震器之间的轴力分配以及在水平变形下的稳定性问题.  相似文献   

20.
Two one‐way eccentric, two‐storey, one‐by‐one‐bay reinforced concrete (RC) structures are pseudodynamically tested under unidirectional ground motions. Theoretical considerations about the effect of torsional coupling on modal periods and shapes agree with modal results of the test structure, considering member stiffness is equal to the secant stiffness to yielding in skew‐symmetric bending. Modal periods of such an elastic structure are in fair agreement with effective periods inferred from the measured response at the beginning of a test of a thoroughly cracked structure and at the end of the test. A time‐varying stiffness matrix and a non‐proportional damping matrix fitted to the test results may be used to reproduce the measured response approximately by modal superposition and identify the role of the four time‐varying modes. Flexible side columns sustained very large drift demands simultaneously in the two transverse directions and suffered significant but not heavy, damage at lap‐splices. RC‐jacketing of the flexible side columns practically eliminated the static eccentricity between the floor centres of twist and mass as well as the torsional response. Inelastic time‐history analysis with point‐hinge member models, using as elastic stiffness the secant stiffness to yielding and neglecting post‐ultimate‐strength cyclic degradation of resistance in members with plain bars and poor detailing, predicted fairly well the response until the peak displacements and member deformations occurred. After that, it underestimated displacement peaks and the lengthening of the apparent period and missed the gradual drifting of the response towards a permanent offset. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏