首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An approximation approach of seismic analysis of two‐way asymmetric building systems under bi‐directional seismic ground motions is proposed. The procedures of uncoupled modal response history analysis (UMRHA) are extended to two‐way asymmetric buildings simultaneously excited by two horizontal components of ground motion. Constructing the relationships of two‐way base shears versus two‐way roof translations and base torque versus roof rotation in ADRS format for a two‐way asymmetric building, each modal pushover curve bifurcates into three curves in an inelastic state. A three‐degree‐of‐freedom (3DOF) modal stick is developed to simulate the modal pushover curve with the stated bifurcating characteristic. It requires the calculation of the synthetic earthquake and angle β. It is confirmed that the 3DOF modal stick is consistent with single‐degree‐of‐freedom modal stick in an elastic state. A two‐way asymmetric three‐story building was analyzed by UMRHA procedure incorporating the proposed 3DOF modal sticks. The analytical results are compared with those obtained from nonlinear response history analysis. It is shown that the 3DOF modal sticks are more rational and effective in dealing with the assessment of two‐way asymmetric building systems under two‐directional seismic ground motions. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

2.
An attempt has been made to explore the general trends in the seismic response of plan‐asymmetric structures without any restrictions imposed by a particular code. Systems with structural elements in both orthogonal directions under bi‐directional excitation were studied. Idealized single‐storey models with bi‐axial eccentricity were employed. The systems were torsionally stiff and, in the majority of cases, mass‐eccentric. The main findings are: in general, inelastic torsional response is qualitatively similar to elastic torsional response. Quantitatively, the torsional effect on the flexible side, expressed as an increase of displacements due to torsion, decreases slightly with increasing plastic deformation, unless the plastic deformations are small. The response on the stiff side generally strongly depends on the effect of several modes of vibration and on the influence of the ground motion in the transverse direction. These influences depend on the structural and ground motion characteristics in both directions. Reduction of displacements due to torsion, typical for elastic torsionally stiff structures, usually decreases with increasing plastic deformations. As an additional effect of large plastic deformations, a flattening of the displacement envelopes in the horizontal plane usually occurs, indicating that torsional effects in the inelastic range are generally smaller than in the elastic range. The dispersion of the results of inelastic torsional response analysis is generally larger than that of elastic analysis. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

3.
The elastic and inelastic seismic response of plan‐asymmetric regular multi‐storey steel‐frame buildings has been investigated under bi‐directional horizontal ground motions. Symmetric variants of these buildings were designed according to Eurocodes 3 and 8. Asymmetric buildings were created by assuming a mass eccentricity in each of the two principal directions. The torsional response in the elastic and inelastic range is qualitatively similar with the exception of the stiff edge in the strong direction of torsionally stiff buildings and the stiff edge in the weak direction of torsionally flexible buildings. The response is influenced by the intensity of ground motion, i.e. by the magnitude of plastic deformation. In the limiting case of very strong ground motion, the behaviour of initially torsionally stiff and initially torsionally flexible buildings may become qualitatively similar. A decrease in stiffness due to plastic deformations in one direction may substantially influence the behaviour in the orthogonal direction. The response strongly depends on the detailed characteristics of the ground motion. On average, torsional effects are reduced with increasing plastic deformations, unless the plastic deformations are small. Taking into account also the dispersion of results which is generally larger in the inelastic range than in the elastic one, it can be concluded that (a) the amplification of displacements determined by the elastic analysis can be used as a rough estimate also in the inelastic range and (b) any favourable torsional effect on the stiff side of torsionally stiff buildings, which may arise from elastic analysis, may disappear in the inelastic range. The conclusions are limited to fairly regular buildings and subject to further investigations. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

4.
A Markov method of analysis is presented for obtaining the seismic response of cable‐stayed bridges to non‐stationary random ground motion. A uniformly modulated non‐stationary model of the random ground motion is assumed which is specified by the evolutionary r.m.s. ground acceleration. Both vertical and horizontal components of the motion are considered to act simultaneously at the bridge supports. The analysis duly takes into account the angle of incidence of the earthquake, the spatial correlation of ground motion and the quasi‐static excitation. A cable‐stayed bridge is analysed under a set of parametric variations in order to study the non‐stationary response of the bridge. The results of the numerical study indicate that (i) frequency domain spectral analysis with peak r.m.s. acceleration as input could provide more r.m.s. response than the peak r.m.s. response obtained by the non‐stationary analysis; (ii) the longitudinal component of the ground motion significantly influences the vertical vibration of the bridge; and (iii) the angle of incidence of the earthquake has considerable influence on the deck response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

5.
地震安全性评价和高层建筑的地震动输入   总被引:3,自引:1,他引:3  
本文根据现行的中国地震烈度区划图中烈度的含义,指出在使用现行“建筑抗震设计规范”时存在的一些问题和与《中华人民共和国防震减灾法》的不协调之处。根据多年参加工程场地地震安全性评价的经验,总结了目前进行地震安全性评价过程中存在的一些问题。文中建议:针对高层建筑进行新的场地分类方法的研究;对高层建筑工程场地作地震安全性评价时,可根据高度的不同,适当简化安全性评价过程。  相似文献   

6.
The concept of intensity‐based assessment for risk‐based decision‐making is introduced. It is realized by means of the so‐called 3R method (response analysis, record selection and risk‐based decision‐making), which can be used to check the adequacy of design of a new building or of the strengthening of an existing building by performing conventional pushover analysis and dynamic analysis for only a few ground motions, which are termed characteristic ground motions. Because the objective of the method is not a precise assessment of the seismic risk, a simple decision model for risk acceptability can be introduced. The engineer can decide that the reliability of a no‐collapse requirement is sufficient when collapse is observed in the case of less than half of, for example, seven characteristic ground motions. From the theoretical point of view, it is shown that the accuracy of the method is acceptable if the non‐linear response history analyses are performed at a low percentile of limit‐state intensity, which is also proven by means of several examples of multi‐storey reinforced concrete frame buildings. The 3R method represents a compromise between the exclusive use of either pushover analysis or dynamic analysis and can be easily introduced into building codes provided that its applicability is further investigated (e.g. asymmetric structures and other performance objectives) and that the procedure for the selection of characteristic ground motions is automated and readily available to engineers (www.smartengineering.si).  相似文献   

7.
A procedure is presented to predict the storey where plastic drift dominates in two‐storey buildings under strong ground motion. The procedure utilizes the yield strength and the mass of each storey as well as the peak ground acceleration. The procedure is based on two different assumptions: (1) the seismic force distribution is of inverted triangular form and (2) the rigid‐plastic model represents the system. The first and the second assumptions, respectively, lead to lower and upper estimates of the base shear coefficient under which the drift of the first storey exceeds that of the second storey. The efficiency of the procedure is verified by dynamic response analyses using elasto‐plastic model. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
This paper describes the three‐dimensional nonlinear analysis of six 19‐storey steel moment‐frame buildings, designed per the 1997 Uniform Building Code, under strong ground motion records from near‐source earthquakes with magnitudes in the range of 6.7–7.3. Three of these buildings possess a reentrant corner irregularity, while the remaining three possess a torsional plan irregularity. The records create drift demands of the order of 0.05 and plastic rotation demands of the order of 4–5% of a radian in the buildings with reentrant corners. These values point to performance at or near ‘Collapse Prevention’. Twisting in the torsionally sensitive buildings causes the plastic rotations on the moment frame on one face of the building (4–5% of a radian) to be as high as twice of that on the opposite face (2–3% of a radian). The asymmetric yield pattern implies a lower redundancy in the lateral force‐resisting system as the failure of the heavily loaded frame could result in a total loss of resistance to torsion. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

9.
The time–frequency and the time‐scale analysis methods are used in this paper to identify the dynamic characteristics of non‐linear seismic response of structural systems with single degree of freedom (SDOF) and multiple degrees of freedom (MDOF). Based on the floor acceleration response time histories of bi‐linear SDOF and MDOF structures, the current study compares the results of system identification using the short‐time Fourier transform (STFT), continuous wavelet transform (CWT) and discrete wavelet transform (DWT) methods. The aim is to identify the frequency variations and the time at on‐set of yielding and unloading of a bi‐linear structural system during seismic response. The results demonstrate that the CWT method is better than the STFT method in both time and frequency resolutions, and that the DWT method is the best at detecting the time at on‐set of yielding and unloading. Combining the results of CWT and DWT methods therefore provides accurate information of both frequency variations and yielding time in non‐linear seismic response. To alleviate the problems associated with noise‐contaminated signals, e.g. seismic response data recorded on site, the study suggests that low‐pass filtering be carried out before applying the DWT method to decompose the signals into multiple levels of details. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

10.
Column shear‐axial failure is a complex response, which lends itself to physical experimentation. Reinforced concrete structures built prior to the mid‐1970s are particularly susceptible to such failure. Shear‐axial column failure has been examined and studied at the element level, but current rehabilitation practice equates such a column failure with structural collapse, neglecting the collapse resistance of the full structural system following column failure. This system‐level response can prevent a column failure from leading to progressive collapse of the entire structure. In this study, a hybrid simulation was conducted on a representative pre‐1970s reinforced concrete frame structure under severe seismic ground motion, in which three full‐scale reinforced concrete columns were tested at the University of Illinois at Urbana Champaign. The analytical portion of the model was represented in the computer program OpenSees. Failure occurred in multiple physical specimens as a result of the ground motion, and the hybrid nature of the test allowed for observation of the system‐level response of the tested columns and the remaining structural system. The behavior of the system accounting for multiple column shear‐axial failure is discussed and characterized. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
In this paper, the effectiveness of different design solutions for tuned mass dampers (TMD) applied to high‐rise cross‐laminated (X‐Lam) timber buildings as a means to reduce the seismic accelerations was investigated. A seven‐storey full‐scale structure previously tested on shaking table was used as a reference. The optimal design parameters of the TMDs, i.e. damping and frequency ratios, were determined by using a genetic algorithm on a simplified model of the reference structure, composed by seven masses each representing one storey. The optimal solutions for the TMDs were then applied to a detailed finite element model of the seven‐storey building, where the timber panels were modelled with shell elements and the steel connectors with linear spring. By comparing the numerical results of the building with and without multiple TMDs, the improvement in seismic response was assessed. Dynamic time‐history analyses were carried out for a set of seven natural records, selected in accordance with Eurocode 8, on the simplified model, and for Kobe earthquake ground motion on the detailed model. Results in terms of acceleration reduction for different TMD configurations show that the behaviour of the seven‐storey timber building can be significantly improved, especially at the upper storeys. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
This paper demonstrates the effectiveness of utilizing advanced ground motion intensity measures (IMs) to evaluate the seismic performance of a structure subject to near‐source ground motions. Ordinary records are, in addition, utilized to demonstrate the robustness of the advanced IM with respect to record selection and scaling. To perform nonlinear dynamic analyses (NDAs), ground motions need to be selected; as a result, choosing records that are not representative of the site hazard can alter the seismic performance of structures. The median collapse capacity (in terms of IM), for example, can be systematically dictated by including a few aggressive or benign pulse‐like records into the record set used for analyses. In this paper, the elastic‐based IM such as the pseudo‐spectral acceleration (Sa) or a vector of Sa and epsilon has been demonstrated to be deficient to assess the structural responses subject to pulse‐like motions. Using advanced IMs can be, however, more accurate in terms of probabilistic response prediction. Scaling earthquake records using advanced IMs (e.g. inelastic spectral displacement, Sdi, and IM 1I&2E; the latter is for the significant higher‐mode contribution structures) subject to ordinary and/or pulse‐like records is efficient, sufficient, and robust relative to record selection and scaling. As a result, detailed record selection is not necessary, and records with virtually any magnitude, distance, epsilon and pulse period can be selected for NDAs. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
This paper studies the effect of coherency loss and wave passage on the seismic torsional response of three‐dimensional, multi‐storey, multi‐span, symmetric, linear elastic buildings. A model calibrated against statistical analyses of ground motion records in Mexico City is used for the coherency function. The structural response is assessed in terms of shear forces in structural elements. Incoherence and wave passage effects are found to be significant only for columns in the ground level of stiff systems. The increase of column shears in the ground level is much higher for soft than for firm soil conditions. For the torsionally stiff systems considered, it is found that incoherent and phase‐delayed ground motions do not induce a significant rotational response of the structure. The use of a code eccentricity to account for torsion due to ground motion spatial variation is assessed. On firm soil, the use of a base shear along with an accidental eccentricity results in highly overestimated shear forces; however, for soft soil conditions, code formulations may result in underestimated shear forces. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

14.
This paper presents the effect of isolator and substructure properties as well as the frequency characteristics and intensity of the ground motion on the performance of seismic‐isolated bridges (SIBs) and examines some critical design clauses in the AASHTO Guide Specification for Seismic Isolation Design. For this purpose, a parametric study, involving more than 800 non‐linear time history analyses of simplified structural models representative of typical SIBs, is conducted. The results from the parametric study are then used to derive important design recommendations and conclusions that may be used by bridge engineers to arrive to a more sound and economical design of SIBs. It is found that the SIB response is a function of the peak ground acceleration to peak ground velocity ratio of the ground motion. Thus, the choice of the seismic ground motion according to the characteristics of the bridge site is crucial for a correct design of the SIB. It is also found that the characteristic strength of the isolator may be chosen based on the intensity and frequency characteristics of the ground motion. Furthermore, the isolator post‐elastic stiffness is found to have a notable effect on the response of SIBs. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

15.
In a companion paper, an overview and problem definition was presented for ground motion selection on the basis of the conditional spectrum (CS), to perform risk‐based assessments (which estimate the annual rate of exceeding a specified structural response amplitude) for a 20‐story reinforced concrete frame structure. Here, the methodology is repeated for intensity‐based assessments (which estimate structural response for ground motions with a specified intensity level) to determine the effect of conditioning period. Additionally, intensity‐based and risk‐based assessments are evaluated for two other possible target spectra, specifically the uniform hazard spectrum (UHS) and the conditional mean spectrum (CMS, without variability).It is demonstrated for the structure considered that the choice of conditioning period in the CS can substantially impact structural response estimates in an intensity‐based assessment. When used for intensity‐based assessments, the UHS typically results in equal or higher median estimates of structural response than the CS; the CMS results in similar median estimates of structural response compared with the CS but exhibits lower dispersion because of the omission of variability. The choice of target spectrum is then evaluated for risk‐based assessments, showing that the UHS results in overestimation of structural response hazard, whereas the CMS results in underestimation. Additional analyses are completed for other structures to confirm the generality of the conclusions here. These findings have potentially important implications both for the intensity‐based seismic assessments using the CS in future building codes and the risk‐based seismic assessments typically used in performance‐based earthquake engineering applications. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
The probability that an earthquake occurs when a train is running over a bridge in earthquake‐prone regions is much higher than before, for high‐speed railway lines are rapidly developed to connect major cities worldwide. This paper presents a finite element method‐based framework for dynamic analysis of coupled bridge–train systems under non‐uniform seismic ground motion, in which rail–wheel interactions and possible separations between wheels and rails are taken into consideration. The governing equations of motion of the coupled bridge–train system are established in an absolute coordinate system. Without considering the decomposition of seismic responses into pseudo‐static and inertia‐dynamic components, the equations of motion of the coupled system are formed in terms of displacement seismic ground motions. The mode superposition method is applied to the bridge structure to make the problem manageable while the Newmark‐β method with an iterative computation scheme is used to find the best solution for the problem concerned. Eight high‐speed trains running over a multi‐span steel truss‐arch bridge subject to earthquakes are taken as a case study. The results from the case study demonstrate that the spatial variation of seismic ground motion affects dynamic responses of the bridge–train system. The ignorance of pseudo‐static component when using acceleration seismic ground motions as input may underestimate seismic responses of the bridge–train system. The probability of separation between wheels and rails becomes higher with increasing train speed. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
This investigation deals with non‐linear seismic responses of free‐standing rectangular rigid bodies on horizontally and vertically accelerating rigid foundations. The responses are classified into two initial responses and four subsequent responses, accordingly the equations of motion governing the liftoff, slip and liftoff–slip interaction motions and boundary conditions corresponding to commencement and termination of the motions are defined. The time histories of responses presented herein show that the body is sensitive to small changes in the friction coefficient and slenderness, and to the wave properties and intensity of ground motions. Systematic trends are observed: the bodies on the low‐grip foundation avoid overturning while they are allowed to slip regardless of details of ground motions; the long period earthquakes tend to make the body overturn and slip largely. In contrast, the timing when liftoff and slip commences and terminates and their directions do not directly correspond with intensity of ground motions. Moreover, the vertical ground motion adds irregularities on the responses, since it excites or damps the responses. It is concluded that governing equations of motion and boundary conditions in view of discontinuous non‐linear systems are necessary to analyse actual motions of the rectangular rigid bodies subjected to horizontal and vertical ground motion. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

18.
The seismic response of single‐degree‐of‐freedom (SDOF) systems incorporating flag‐shaped hysteretic structural behaviour, with self‐centring capability, is investigated numerically. For a SDOF system with a given initial period and strength level, the flag‐shaped hysteretic behaviour is fully defined by a post‐yielding stiffness parameter and an energy‐dissipation parameter. A comprehensive parametric study was conducted to determine the influence of these parameters on SDOF structural response, in terms of displacement ductility, absolute acceleration and absorbed energy. This parametric study was conducted using an ensemble of 20 historical earthquake records corresponding to ordinary ground motions having a probability of exceedence of 10% in 50 years, in California. The responses of the flag‐shaped hysteretic SDOF systems are compared against the responses of similar bilinear elasto‐plastic hysteretic SDOF systems. In this study the elasto‐plastic hysteretic SDOF systems are assigned parameters representative of steel moment resisting frames (MRFs) with post‐Northridge welded beam‐to‐column connections. In turn, the flag‐shaped hysteretic SDOF systems are representative of steel MRFs with newly proposed post‐tensioned energy‐dissipating connections. Building structures with initial periods ranging from 0.1 to 2.0s and having various strength levels are considered. It is shown that a flag‐shaped hysteretic SDOF system of equal or lesser strength can always be found to match or better the response of an elasto‐plastic hysteretic SDOF system in terms of displacement ductility and without incurring any residual drift from the seismic event. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

19.
Near‐fault ground motions are characterized by long‐period horizontal pulses and high values of the ratio between the peak value of the vertical acceleration, PGAV, and the analogous value of the horizontal acceleration, PGAH, which can become critical for base‐isolated (BI) structures. The objective of the present work is to check the effectiveness of the base isolation of framed buildings when using High‐Damping‐Rubber Bearings (HDRBs), taking into consideration the combined effects of the horizontal and vertical components of near‐fault ground motions. To this end, a numerical investigation is carried out with reference to BI reinforced concrete buildings designed according to the European seismic code (Eurocode 8). The design of the test structures is carried out in a high‐risk region considering (besides the gravity loads) the horizontal seismic loads acting alone or in combination with the vertical ones and assuming different values of the ratio between the vertical and horizontal stiffnesses of the HDRBs. The nonlinear seismic analysis is performed using a step‐by‐step procedure based on a two‐parameter implicit integration scheme and an initial‐stress‐like iterative procedure. At each step of the analysis, plastic conditions are checked at the potential critical sections of the girders (i.e. end sections of the sub‐elements in which a girder is discretized) and columns (i.e. end sections), where a bilinear moment–curvature law is adopted; the effect of the axial load on the ultimate bending moment (M‐N interaction) of the columns is also taken into account. The response of an HDRB is simulated by a model with variable stiffness properties in the horizontal and vertical directions, depending on the axial force and lateral deformation, and linear viscous damping. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
The critical parameters that influence the nonlinear seismic response of asymmetric‐plan buildings are identified by evaluating the effects of different asymmetries that may characterize the structure of a building as well as exploring the influence of the ground motion features. First, the main findings reported in the literature on both the linear and nonlinear dynamic response of asymmetric‐plan buildings are presented. The common findings and the conflicting conclusions reached in different investigations are pointed out. Then, the results of comprehensive nonlinear dynamic analyses performed for evaluating the seismic response of systems characterized by different strength and stiffness configurations, representative of a large class of asymmetric‐plan buildings, are reported. Findings from the study indicate that the building response changes when moving from the linear to the nonlinear range, so that the seismic behavior of asymmetric‐plan buildings, apart from the source of asymmetry, can be always classified as irregular. Additionally, it was observed that as the seismic demands cause amplification of system nonlinearity with increasing earthquake intensity, the maximum displacement demand in the different resisting elements tends to be reached with the same deformed configuration of the system. The resultant of the seismic forces producing such a maximum demand is located at the center of resistance and corresponds to the collapse mechanism of the system that provides the maximum lateral strength in the exciting direction of the seismic action. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号