首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 29 毫秒
1.
A 1:5 scale five‐story RC building model having the irregularities of a soft/weak story and torsion at the ground story was subjected to a series of earthquake simulation tests. The test results reveal the following: The eccentricity varied from zero to infinity with the values of base shear and torque bounded by some limits. As the intensity of table excitations increased, representing earthquakes with return periods from 50 to 2500 years in Korea, the range of eccentricities at the peak values in the time histories of drift and base shear decreased from approximately ±30% to within ±10% of the transverse dimension of the model. The inertial torque was resisted by both longitudinal and transverse frames, in proportion to their instantaneous rigidity. Yielding of the longitudinal frames under severe table excitations caused a substantial loss in their instantaneous torsional resistance and thereby transferred most of the large torque to the transverse frames, resulting in a significantly degraded torsional stiffness with an enlarged torsional deformation despite almost zero eccentricity. From these observations, it is clear that the eccentricity in itself cannot represent the critical torsional behaviors. To overcome this problem, the demand in torque shall be determined in a direct relationship with the base or story shear, given as an ellipse constructed with the maximum points in its principal axes located by the two adjacent torsion‐dominant modal spectral values. This approach provides a simple but transparent design tool by enabling comparison between demand and supply in shear force–torque diagrams. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
The seismic design of multi‐story buildings asymmetric in plan yet regular in elevation and stiffened with ductile RC structural walls is addressed. A realistic modeling of the non‐linear ductile behavior of the RC walls is considered in combination with the characteristics of the dynamic torsional response of asymmetric buildings. Design criteria such as the determination of the system ductility, taking into account the location and ductility demand of the RC walls, the story‐drift demand at the softer (most displaced) edge of the building under the design earthquake, the allowable ductility (ultimate limit state) and the allowable story‐drift (performance goals) are discussed. The definition of an eccentricity of the earthquake‐equivalent lateral force is proposed and used to determine the effective displacement profile of the building yet not the strength distribution under the design earthquake. Furthermore, an appropriate procedure is proposed to calculate the fundamental frequency and the earthquake‐equivalent lateral force. A new deformation‐based seismic design method taking into account the characteristics of the dynamic torsional response, the ductility of the RC walls, the system ductility and the story‐drift at the softer (most displaced) edge of the building is presented and illustrated with an example of seismic design of a multi‐story asymmetric RC wall building. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

3.
In order to mitigate the effect of torsion during earthquakes, most seismic codes of the world provide design guidelines for strength distribution based on the traditional perception that element stiffness and strength are independent parameters. Recent studies have pointed out that for an important class of widely used structural elements such as reinforced concrete flexural walls, stiffness is a strength‐dependent parameter. This implies that the lateral stiffness distribution in a wall‐type system cannot be defined prior to the assignment of elements' strength. Consequently, stiffness eccentricity cannot be computed readily and the current codified torsional provisions cannot be implemented in a straightforward manner. In this study, an alternate guideline for strength distribution among lateral force resisting elements is presented. To develop such a guideline, certain issues related to the dynamic behaviour of asymmetric wall‐type systems during a damaging earthquake were examined. It is shown that both stiffness and strength eccentricity are important parameters affecting the seismic response of asymmetric wall‐type systems. In particular, results indicate that torsional effects can be minimized by using a strength distribution that results in the location of the centre of strength CV and the centre of rigidity CR on the opposite sides of the centre of mass CM. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

4.
Based on an asymmetric multistorey frame building model, this paper investigates the influence of a building's higher vibration modes on its inelastic torsional response and evaluates the adequacy of the provisions of current seismic building codes and the modal analysis procedure in accounting for increased ductility demand in frames situated at or near the stiff edge of such buildings. It is concluded that the influence of higher vibration modes on the response of the upper-storey columns of stiff-edge frames increases significantly with the building's fundamental uncoupled lateral period and the magnitude of the stiffness eccentricity. The application of the equivalent static torsional provisions of certain building codes may lead to non-conservative estimates of the peak ductility demand, particularly for structures with large stiffness eccentricity. In these cases, the critical elements are vulnerable to excessive additional ductility demand and, hence, may be subject to significantly more severe structural damage than in corresponding symmetric buildings. It is found that regularly asymmetric buildings excited well into the inelastic range may not be conservatively designed using linear elastic modal analysis theory. Particular caution is required when applying this method to the design of stiff-edge frame elements in highly asymmetric structures.  相似文献   

5.
The dynamic equations of motion of asymmetric offshore platforms under three different environmental conditions:seismic action,wave action and their combination are established in this paper. In establishing these motion equations,three typical eccentricity types including mass eccentricity,rigidity eccentricity and their combination were considered,as are eccentricities that occur un-idirectionally and bi-directionally. The effects of the eccentricity type,the dynamic characteristics and the environmental conditions on the torsional coupling response of platforms are investigated and compared. An effort has also been made to analyze the inffluence of accidental eccentricity on asymmetric platforms with different eccentricity in two horizontally orthogonal directions. The results are given in terms of non-dimensional parameters,accounting for the uncoupled torsional to lateral frequency ratio. Numerical results reveal that the eccentricity type has a great inffluence on the torsionally coupled response under different environmental conditions. Therefore,it is necessary to consider the combination of earthquake and wave action in the seismic response analysis of some offshore platforms.  相似文献   

6.
Static torsional provisions in most seismic codes require that the lateral force at each floor level be applied at some distance from the reference centre at that floor. However, codes do not specify how to determine the locations of these centres. As a result, several different definitions of the reference centres are being used to implement the code analysis. This investigation examined how the results using various reference centres differ and which of these centres would lead to results that are in agreement with those of dynamic analysis. For this purpose three different buildings ranging form torsionally stiff to torsionally flexible were analysed. It was shown that for the class of buildings studied in this investigation that although the locations of the reference centres were quite different, the results were very similar and nearly independent of the reference centre. Comparison of results calculated from static code equivalent lateral force procedures and results from dynamic response spectrum analyses showed that the static code procedures led to design forces very close (flexible wall) or slightly conservative (stiff wall) when compared to the dynamic analysis for the torsionally stiff building. However, the static code procedures significantly underestimated the design forces of the stiff walls and significantly overestimated the design forces of the flexible walls for the torsionally flexible buildings. © 1998 John Wiley & Sons, Ltd.  相似文献   

7.
The paper deals with the topic of analyses performed according to modern code provisions, in particular Eurocode 8 (EC8) rules. Non linear static and non linear dynamic analyses of a plan irregular multi-storey r/c frame building designed according to Eurocode 2 (EC2) and EC8 provisions are carried out.The extension of the N2 method to torsionally flexible structures, as applied in previous papers, does not consider the accidental eccentricity, which is prescribed by EC8 also in the case of non linear static analysis. In this paper, three methods combining the accidental eccentricity prescribed by EC8 to the procedure which extends the N2 method to torsionally flexible structures are proposed and discussed. Each of them provides four modal response spectrum analyses (one for each model, corresponding to each position of centre of mass) and eight non linear static analyses (two signs for four models). NLSA(meth. n.2) seems to be the more reliable method of the three proposed, because it better fits absolute displacements obtained by non linear dynamic analysis.In the paper it is also observed that the value of the behaviour factor assigned by EC8 to torsionally flexible systems seems too conservative.  相似文献   

8.
9.
The differences between the increase in building response due to accidental eccentricity predicted by code-specified static and dynamic analyses are studied for symmetric and unsymmetric single and multistorey buildings. The increase in response computed from static analysis of the building is obtained by applying the equivalent static forces at distance ea, equal to the storey accidental eccentricity, from the centre of mass at each floor. Alternatively, this increase in response is computed by dynamic analysis of the building with the centre of mass of each floor shifted through a distance ea from its nominal position. A parametric study is performed on single-storey systems in order to evaluate the differences in response predicted by both analysis procedures. It is shown that these results are essentially the same as the ones obtained for a special class of multistorey systems. Upper and lower bounds for the differences in response computed from static and dynamic analyses are obtained for general multistorey systems. These differences in response depend primarily on the ratio of the fundamental torsional and lateral frequencies of the building. They are larger for small values of the frequency ratio and decrease to zero as the frequency ratio becomes large. Further, these discrepancies are in many cases of the same order as the code-intended increase in response due to accidental eccentricity. This implies that the code-specified static and dynamic analyses to account for accidental torsion should be modified to be mutually consistent.  相似文献   

10.
不对称大底板多塔楼隔震结构的地震响应分析   总被引:1,自引:0,他引:1  
党育  杜永峰 《地震学刊》2012,(4):452-458
针对不对称大底板多塔楼隔震结构体系,通过建立地震响应的动力分析简化模型,推导出不对称大底板多塔楼隔震结构体系地震作用下的运动方程。对一实际的不对称大底板多塔楼隔震结构进行地震响应仿真分析,探讨塔楼质量偏心率和塔楼质量比对结构周期比、位移比和层剪力比的影响。结果显示,不对称大底板多塔楼隔震结构扭转角主要由隔震层产生;与不隔震结构相比,不对称大底板多塔楼隔震体系的扭转角减小,可取得较好的减震效果;塔楼与底板的位置分布和质量分布会影响体系的扭转效应和减震效果,应尽量使塔楼的质心与底板质心重合,塔楼质量分布均匀,以减小结构的扭转效应,提高减震效果。  相似文献   

11.
This paper presents the results of an analytical study of the strength distribution of lateral load resisting elements in torsionally unbalanced systems designed based on codified torsional provisions. It is shown that the element strength can be expressed conveniently as the element strength of a similar but torsionally balanced system multiplied by a strength factor. This strength factor depends on three system parameters, namely, the location of the element relative to the centre of rigidity, and the torsional stiffness and eccentricity of the structure. In addition, it depends on the design coefficients of the code specified design eccentricity expressions. The influence of each of these factors on the element strength distribution is discussed. A new set of values for the design coefficients is proposed. By means of examples, it is shown that the proposed torsional provision is an improvement over those suggested in the National Building Code of Canada and the New Zealand code.  相似文献   

12.
A new floor connecting system developed for low‐damage seismic‐resistant building structures is described herein. The system, termed Inertial Force‐Limiting Floor Anchorage System (IFAS), is intended to limit the lateral forces in buildings during an earthquake. This objective is accomplished by providing limited‐strength deformable connections between the floor system and the primary elements of the lateral force‐resisting system. The connections transform the seismic demands from inertial forces into relative displacements between the floors and lateral force‐resisting system. This paper presents the IFAS performance in a shake‐table testing program that provides a direct comparison with an equivalent conventional rigidly anchored‐floor structure. The test structure is a half‐scale, 4‐story reinforced concrete flat‐plate shear wall structure. Precast hybrid rocking walls and special precast columns were used for test repeatability in a 22‐input strong ground‐motion sequence. The structure was purposely designed with an eccentric wall layout to examine the performance of the system in coupled translational‐torsional response. The test results indicated a seismic demand reduction in the lateral force‐resisting system of the IFAS structure relative to the conventional structure, including reduced shear wall base rotation, shear wall and column inter‐story drift, and, in some cases, floor accelerations. These results indicate the potential for the IFAS to minimize damage to the primary structural and non‐structural components during earthquakes.  相似文献   

13.
Lateral–torsional coupling in asymmetric‐plan buildings leads to correlated translations and rotations of the building plan, which generate uneven distributions of deformation demand among resisting planes. The deformation demand of a resisting plane depends on the relative magnitude of the plan translation and rotation and on the correlation between the two signals. Thus, small rotations highly correlated with building translation may lead to significantly different deformations of the resisting planes at the building edges. Consequently, the use of supplemental dampers is intended not only to reduce the magnitude of the plan translation and rotation, but also the correlation between these motions. For the sake of simplicity, linear viscous dampers are used in this investigation, which properly located in plan lead to a minimum response of the geometric center, thus achieving the same mean‐square value of the displacements at the building edges. Mathematically, this condition may be understood as creating zero correlation between the translations and rotation at the geometric center of the plan, which represents an uncoupling in the mean‐square sense. Results show that the optimal damper location depends on the static eccentricity and frequency ratio of the bare structure, the total amount of supplemental damping considered, and the frequency content of the excitation. Through a final 6‐story model example, the torsional balance concept is demonstrated to work on multistory buildings subjected to bidirectional ground motions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Factors α and β used in equivalent static analysis to account for natural and accidental torsion are evaluated with consideration of soil–structure interaction. The combined torsional effects of structural asymmetry and foundation rotation are examined with reference to a single monosymmetric structure placed on a rigid foundation that is embedded into an elastic half‐space, under to the action of non‐vertically incident SH waves. Dynamic and accidental eccentricities are developed such that when used together with the code‐specified base shear, the resulting static displacement at the flexible edge of the building is identical to that computed from dynamic analysis. It is shown that these eccentricities do not have a unique definition because they depend on both the selection of the design base shear and the criterion used for separation of the torsional effects of foundation rotation from those of structural asymmetry. Selected numerical results are presented in terms of dimensionless parameters for their general application, using a set of appropriate earthquake motions for ensuring generality of conclusions. The practical significance of this information for code‐designed buildings is elucidated. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

15.
The period of vibration is a fundamental parameter in the force‐based design of structures as this parameter defines the spectral acceleration and thus the base shear force to which the building should be designed. This paper takes a critical look at the way in which seismic design codes around the world have allowed the designer to estimate the period of vibration for use in both linear static and dynamic analysis. Based on this review, some preliminary suggestions are made for updating the clauses related to the estimation of the periods of vibration in Eurocode 8. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
This study aims to determine the influence of torsional coupling on the inelastic response of a series of models representing typical structural configurations in real buildings. The lake bed (SCT) east-west component of the 1985 Mexico City earthquake was employed in the analysis, and is representative of a severe ground motion known to have induced large inelastic structural deformations in a high proportion of those buildings having asymmetrical distributions of stiffness and/or strength. Material non-linearity in lateral load-resisting elements has been defined using a hysteretic Ramberg-Osgood model. Structural eccentricities have been introduced into the building models by (i) asymmetrical distributions of stiffness and/or strength, (ii) asymmetrical configuration of lateral load-resisting elements, or (iii) varying post-elastic material behaviour in the resisting elements. The dynamic inelastic response of these models has been obtained by a numerical integration of the relevant equations of motion, expressed in a non-dimensional incremental form.

In the elastic range, the results correlate well with those of previous studies. In the inelastic range, it is concluded that the peak ductility demand of the worst-affected element increases with the ground excitation level across the range of building periods considered, and that the influence of torsional coupling on the key response parameters is model dependent. Most significantly, the strength eccentricity relative to the centre of mass has been shown to influence the peak edge displacement response more than conventionally employed stiffness eccentricity.  相似文献   


17.
The inelastic seismic torsional response of simple structures is examined by means of shear‐beam type models as well as with plastic hinge idealization of one‐story buildings. Using mean values of ductility factors, obtained for groups of ten earthquake motions, as the basic index of post‐elastic response, the following topics are examined with the shear‐beam type model: mass eccentric versus stiffness eccentric systems, effects of different types of motions and effects of double eccentricities. Subsequently, comparisons are made with results obtained using a more realistic, plastic hinge type model of single‐story reinforced concrete frame buildings designed according to a modern Code. The consequences of designing for different levels of accidental eccentricity are also examined for the aforementioned frame buildings. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

18.
An analytical study of the seismic response of typical base isolated structures mounted on rubber bearings is presented. Isolated buildings are liable to have closely spaced lower modes of vibration with small eccentricity between centres of mass and rigidity. The isolated structure is modelled as a rigid deck with lumped masses supported on axially inextensible elastomeric rubber bearings. This simplified system has three degrees of freedom (dof), two translations and one rotation in the horizontal plane. The Green's functions for the displacement response of the 3 dof system are derived for both undamped and damped cases with small and large eccentricities. The small eccentricity case is taken from a specific isolated building, while the large eccentricity case arises from the 5 per cent accidental eccentricity which is required by various seismic codes. An interaction equation for normalized displacements is established for an idealized flat velocity spectrum or hyperbolic acceleration spectrum. An isolated building on rubber bearings would have its fundamental period fall into this range of a design spectrum. Numerical results for the specific building subjected to the El Centro earthquake of 1940 are presented. Both the time history and the response spectrum modal superposition analysis were performed. In the response spectrum analysis, the Complete Quadratic Combination (CQC) showed superiority over the Square Root of the Sum of Squares (SRSS) in estimating maximum responses. It is concluded that the effect of torsional coupling on the transient response of base isolated structures is insignificant, due to the combined effect of the time lag between the maximum translational and torsional responses and the influence of damping in the isolation system which for elastomeric bearings can be as high as 8 to 10 per cent.  相似文献   

19.
Seismic Design of Symmetric Structures for Accidental Torsion   总被引:5,自引:0,他引:5  
The paper presents an analytical estimation of the dynamic effects, caused by the shifting of the centre of mass with accidental eccentricity in symmetric structures. The approximate analytical solution proves, that even under small accidental eccentricities the symmetric structures exhibit “irregular behaviour” and the accidental torsional effects cannot be described properly by static application of torsional moments. The prescribed application rule by Eurocode 8 for multimodal analysis underestimates the accidental torsional effects up to 21% for 5% eccentricity for the structures considered in the paper. An expression for the correction of member responses is derived. It is proved by numerical simulations of the dynamic response of three-dimensional models of symmetric structures, that the proposed correction coefficient gives accurate results in cases of single-storey and multi-storey structures. It gives a convenient way for the design practice to estimate accurately the accidental torsional effects on planar and 3-D models of symmetric structures. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

20.
Seismic building codes include design provisions to account for the torsional effects arising in torsionally unbalanced (asymmetric) buildings. These provisions are based on two alternative analytical procedures for determining the design load for the individual resisting structural elements. A previous study has shown that the linear elastic modal analysis procedure may not lead to conservative designs, even for multistorey buildings with regular asymmetry, when such structures are excited well into the inelastic range of response. The equivalent static force procedure as recommended by codes may also be deficient in accounting for additional ductility demand in the critical stiff-edge elements. This paper addresses the non-conservatism of existing static torsional provisions and examines aspects of element strength distribution and its influence on inelastic torsional effects. A recommendation is made for improving the effectiveness of the code-type static force procedure for torsionally unbalanced multistorey frame buildings with regular asymmetry, leading to a design approach which estimates conservatively the peak ductility demand of edge elements on both sides of the building. The modified approach also retains the simplicity of existing code provisions and results in acceptable levels of additional lateral design strength. It has recently been adopted by the new Australian earthquake code, which is due to be implemented early in 1993.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号