首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 151 毫秒
1.
Aquifer parameter estimation from surface resistivity data   总被引:7,自引:0,他引:7  
This paper is devoted to the additional use, other than ground water exploration, of surface geoelectrical sounding data for aquifer hydraulic parameter estimation. In a mesoscopic framework, approximated analytical equations are developed separately for saline and for fresh water saturations. A few existing useful aquifer models, both for clean and shaley sandstones, are discussed in terms of their electrical and hydraulic effects, along with the linkage between the two. These equations are derived for insight and physical understanding of the phenomenon. In a macroscopic scale, a general aquifer model is proposed and analytical relations are derived for meaningful estimation, with a higher level of confidence, of hydraulic parameter from electrical parameters. The physical reasons for two different equations at the macroscopic level are explicitly explained to avoid confusion. Numerical examples from existing literature are reproduced to buttress our viewpoint.  相似文献   

2.
This paper presents a vertically averaged model for studying water and solute exchanges between a large river and its adjacent alluvial aquifer. The hydraulic model couples horizontal 2D Saint Venant equations for river flow and a 2D Dupuit equation for aquifer flow. The dynamic coupling between river and aquifer is provided by continuity of fluxes and water level elevation between the two domains. Equations are solved simultaneously by linking the two hydrological system matrices in a single global matrix in order to ensure the continuity conditions between river and aquifer and to accurately model two‐way coupling between these two domains. The model is applied to a large reach (about 36 km2) of the Garonne River (south‐western France) and its floodplain, including an instrumented site in a meander. Simulated hydraulic heads are compared with experimental measurements on the Garonne River and aquifer in the floodplain. Model verification includes comparisons for one point sampling date (27 piezometers, 30 March 2000) and for hydraulic heads variations measured continuously over 5 months (5 piezometers, 1 January to 1 June 2000). The model accurately reproduces the strong hydraulic connections between the Garonne River and its aquifer, which are confirmed by the simultaneous variation of the water level in the river and in piezometers located near the river bank. The simulations also confirmed that the model is able to reproduce groundwater flow dynamics during flood events. Given these results, the hydraulic model was coupled with a solute‐transport component, based on advection‐dispersion equations, to investigate the theoretical dynamics of a conservative tracer over 5 years throughout the 36 km2 reach studied. Meanders were shown to favour exchanges between river and aquifer, and although the tracer was diluted in the river, the contamination moved downstream from the injection plots and affected both river banks. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
《水文科学杂志》2013,58(4):868-882
Abstract

Non-Darcian flow in a finite fractured confined aquifer is studied. A stream bounds the aquifer at one side and an impervious stratum at the other. The aquifer consists of fractures capable of transmitting water rapidly, and porous blocks which mainly store water. Unsteady flow in the aquifer due to a sudden rise in the stream level is analysed by the double-porosity conceptual model. Governing equations for the flow in fractures and blocks are developed using the continuity equation. The fluid velocity in fractures is often too high for the linear Darcian flow so that the governing equation for fracture flow is modified by Forcheimer's equation, which incorporates a nonlinear term. Governing equations are coupled by an interaction term that controls the quasi-steady-state fracture—block interflow. Governing equations are solved numerically by the Crank-Nicolson implicit scheme. The numerical results are compared to the analytical results for the same problem which assumes Darcian flow in both fractures and blocks. Numerical and analytical solutions give the same results when the Reynolds number is less than 0.1. The effect of nonlinearity on the flow appears when the Reynolds number is greater than 0.1. The higher the rate of flow from the stream to the aquifer, the higher the degree of nonlinearity. The effect of aquifer parameters on the flow is also investigated. The proposed model and its numerical solution provide a useful application of nonlinear flow models to fractured aquifers. It is possible to extend the model to different types of aquifer, as well as boundary conditions at the stream side. Time-dependent flow rates in the analysis of recession hydrographs could also be evaluated by this model.  相似文献   

4.
Available expressions which describe the water-table fluctuation in a stream-aquifer system are based primarily on the assumption that the bed of the stream is as permeable as the aquifer it completely cuts through. Analytical expressions are developed, in terms of the head averaged over the depth of saturation, which take into account the semiperviousness of the streambed. The situations considered are finite and semi-infinite aquifer systems in which the water level in the semipervious stream is suddenly lowered below its initial elevation, and suddenly raised above its initial elevation, and maintained constant thereafter. As a by-product, solutions are also obtained for finite and semi-infinite aquifer systems in which the bed of the stream is as permeable as the aquifer.  相似文献   

5.
Abstract

A numerical technique is presented whereby aquifer hydraulic diffusivities (D) and macrodispersivities (α) are calculated by linear equations rewritten from flow and solute transport differential equations. The approach requires a GIS to calculate spatial and temporal hydraulic head (h) and solute concentration gradients. The model is tested in Portugal, in a semi-confined aquifer periodically monitored for h and chloride/sulphate concentrations. Average D (0.46 m2/s) and α (1975 m) compare favourably with literature results. The relationship between α and scale (L) is also investigated. In this context, two aquifer groups could be identified: the first group is heterogeneous at the “macroscopic” scale (solute travelled distances <1 km), but homogeneous at the “megascopic” scale. The overall scale dependency in this case is given by an equation of logarithmic type. The second group is heterogeneous at the macroscopic and megascopic scales, with a scale dependency of linear type.

Citation Pacheco, F.A.L., 2013. Hydraulic diffusivity and macrodispersivity calculations embedded in a geographic information system. Hydrological Sciences Journal, 58 (4), 930–944.  相似文献   

6.
7.
The study demonstrates spectral relationships in the time–frequency domain for one‐dimensional groundwater flow in aquifers bounded by fluctuating boundaries. By nature, the solutions of spectral equations are non‐linear complex functions. To determine hydraulic diffusivity in the governing equations, it is required that the data are collected from the spectra of water levels at the fluctuating boundaries and observation wells. Hydraulic diffusivity thus can be obtained by an iterative inverse approach. This paper presents an application in Pingtung County of Taiwan to determine the hydraulic diffusivity of a sandy aquifer under confined conditions. Spectral density function of water level obtained from tidal boundaries and observation wells are used to approximate hydraulic diffusivity, which yields an averaged value of 1·26 × 106 m2/h. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

8.
This study is focused on a passive treatment system known as the horizontal reactive treatment well (HRX Well®) installed parallel to groundwater flow, which operates on the principle of flow focusing that results from the hydraulic conductivity (K) ratio of the well and aquifer media. Passive flow and capture in the HRX Well are described by simplified equations adapted from Darcy's Law. A field pilot-scale study (PSS) and numerical simulations using a finite element method (FEM) were conducted to verify the HRX Well concept and test the validity of the HRX Well-simplified equations. The hydraulic performance results from both studies were observed to be within a close agreement to the simplified equations and their hydraulic capture width approximately five times greater than the well diameter (0.20 m). Key parameters affecting capture included the aquifer thickness, well diameter, and permeability ratio of the HRX Well treatment media and aquifer material. During pilot testing, the HRX Well captured 39% of flow while representing 0.5% of the test pit cross-sectional volume, indicating that the well captures a substantial amount of surrounding groundwater. While uncertainty in the aquifer and well properties (porosity, K, well losses), including the effects of boundary conditions, may have caused minor differences in the results, data from this study indicate that the simplified equations are valid for the conceptual design of a field study. A full-scale HRX Well was installed at Site SS003 at Vanderberg Air Force Base, California, in July/August 2018 based on outcomes from this study.  相似文献   

9.
The validity of a previously proposed but untested modification to equations for flow to a horizontal well is assessed using a specially developed finite-difference model. This modification extends confined flow equations to allow the head in the well and the saturated depth at the well to be estimated in unconfined conditions. The study is limited to the case of two-dimensional flow with no flow in the direction parallel to the line of the well. The results show that the modified equations for both a finite unconfined aquifer and, by inference, an infinite unconfined aquifer are adequately accurate for practical application.  相似文献   

10.
This work is the seventh in a series that introduces and employs the thermodynamically constrained averaging theory (TCAT) for modeling flow and transport in multiscale porous medium systems. This paper expands the previous analyses in the series by developing models at a scale where spatial variations within the system are not considered. Thus the time variation of variables averaged over the entire system is modeled in relation to fluxes at the boundary of the system. This implementation of TCAT makes use of conservation equations for mass, momentum, and energy as well as an entropy balance. Additionally, classical irreversible thermodynamics is assumed to hold at the microscale and is averaged to the megascale, or system scale. The fact that the local equilibrium assumption does not apply at the megascale points to the importance of obtaining closure relations that account for the large-scale manifestation of small-scale variations. Example applications built on this foundation are suggested to stimulate future work.  相似文献   

11.
A transient axisymmetric saturated-unsaturated numerical flow model was coupled with a particle tracking model to investigate the movement of contaminants when a shallow unconfined aquifer is pumped at a constant rate. The particle tracking model keeps track of locations and masses of solutes in the aquifer, and the time of capture by the well. At the end of each time-step the flow model solves the Richard's equation for the hydraulic head distribution from which elemental velocities are calculated. Solutes are then displaced for a period equivalent to the time-step using both the magnitude and direction of the elemental velocities. Numerical experiments were performed to investigate effluent concentrations in wells with screens of different length and in different positions relative to zones of stratified contamination. At early times of pumping the effluent concentrations were similar to the concentrations adjacent to the well screen, but at late times, the concentrations approached the vertically averaged concentration in the aquifer. Time to attain the vertically averaged concentration was determined by the well geometry, initial location of the contaminant plume in relation to the well screen, and hydraulic properties of the aquifer. The results are consistent with the hydraulics of flow to a pumping well and of particular importance, they demonstrate that short-term pump tests could give erroneous design concentrations for pump-and-treat systems. The model provides a means of quantifying arrival times and mixing ratios. It could therefore provide a useful means of designing production wells in aquifers with stratified contamination and more efficient recovery systems for aquifer remediation.  相似文献   

12.
13.
Optimized system to improve pumping rate stability during aquifer tests   总被引:1,自引:0,他引:1  
Aquifer hydraulic properties are commonly estimated using aquifer tests, which are based on an assumption of a uniform and constant pumping rate. Substantial uncertainties in the flow rate across the borehole-formation interface can be induced by dynamic head losses, caused by rapid changes in borehole water levels early in an aquifer test. A system is presented that substantially reduces these sources of uncertainty by explicitly accounting for dynamic head losses. The system which employs commonly available components (including a datalogger, pressure transducers, a variable-speed pump motor, a flow controller, and flowmeters), is inexpensive, highly mobile, and easily set up. It optimizes the flow rate at the borehole-formation interface, making it suitable for any type of aquifer test, including constant, step, or ramped withdrawal and injection, as well as sinusoidal. The system was demonstrated for both withdrawal and injection tests in three aquifers at the Savannah River Site. No modifications to the control system were required, although a small number of characteristics of the pumping and monitoring system were added to the operating program. The pumping system provided a statistically significant, constant flow rate with time. The range in pumping variability (95% confidence interval) was from +/- 2.58 x 10(-4) L/sec to +/- 9.07 x 10(-4) L/sec, across a wide range in field and aquifer conditions.  相似文献   

14.
Many problems in hydraulics and hydrology are described by linear, time dependent partial differential equations, linearity being, of course, an assumption based on necessity.Solutions to such equations have been obtained in the past based purely on deterministic consideration. The derivation of such a solution requires that the initial conditions, the boundary conditions, and the parameters contained within the equations be stipulated in exact terms. It is obvious that the solution so derived is a function of these specified, values.There are at least four ways in which randomness enters the problem. i) the random initial value problem; ii) the random boundary value problem; iii) the random forcing problem when the non-homogeneous part becomes random and iv) the random parameter problem.Such randomness is inherent in the environment surrounding the system, the environment being endowed with a large number of degrees of freedom.This paper considers the problem of groundwater flow in a phreatic aquifer fed by rainfall. The goveming equations are linear second order partial differential equations. Explicit form solutions to this randomly forced equation have been derived in well defined regular boundaries. The paper also provides a derivation of low order moment equations. It contains a discussion on the parameter estimation problem for stochastic partial differential equations.  相似文献   

15.
Chenaf D  Chapuis RP 《Ground water》2002,40(4):385-389
Starting from the equations of Theis and Cooper-Jacob, two new mathematical methods are proposed for interpreting the residual drawdown data for an infinite confined aquifer. Under Theis' assumptions and using the Cooper-Jacob approximation, the principal aquifer characteristics of transmissivity, pumping storativity, and recovery storativity are expressed without any correction or additional assumption. An actual case is used for illustration and confirms the validity of proposed equations and methods.  相似文献   

16.
The nonhorizontal‐model‐layer (NHML) grid system is more accurate than the horizontal‐model‐layer grid system to describe groundwater flow in an unconfined sloping aquifer on the basis of MODFLOW‐2000. However, the finite‐difference scheme of NHML was based on the Dupuit‐Forchheimer assumption that the streamlines were horizontal, which was acceptable for slope less than 0.10. In this study, we presented a new finite‐difference scheme of NHML based on the Boussinesq assumption and developed a new package SLOPE which was incorporated into MODFLOW‐2000 to become the MODFLOW‐SP model. The accuracy of MODFLOW‐SP was tested against solution of Mac Cormack (1969). The differences between the solutions of MODFLOW‐2000 and MODFLOW‐SP were nearly negligible when the slope was less than 0.27, and they were noticeable during the transient flow stage and vanished in steady state when the slope increased above 0.27. We established a model considering the vertical flow using COMSOL Multiphysics to test the robustness of constrains used in MODFLOW‐SP. The results showed that streamlines quickly became parallel with the aquifer base except in the narrow regions near the boundaries when the initial flow was not parallel to the aquifer base. MODFLOW‐SP can be used to predict the hydraulic head of an unconfined aquifer along the profile perpendicular to the aquifer base when the slope was smaller than 0.50. The errors associated with constrains used in MODFLOW‐SP were small but noticeable when the slope increased to 0.75, and became significant for the slope of 1.0.  相似文献   

17.
A mathematical optimal control method is developed to identify a hydraulic conductivity distribution in a density dependent flow field. Using a variational method, the adjoint partial differential equations are obtained for the density- dependent state equations used for the saline aquifer water flow. The adjoint equations are numerically solved in through a finite difference method. The developed method is applied to identify the hydraulic conductivity distribution through the numerical solution of an optimal control problem. To demonstrate the effectiveness of the optimal control method, three numerical experiments are conducted with artificial observation data. The results indicate that the developed method has the potential to accurately identify the hydraulic conductivity distribution in a saline water aquifer flow system.  相似文献   

18.
Smith AJ 《Ground water》2008,46(2):228-238
Published frequency-domain solutions of periodic flow in aquifers apply strictly to mathematically linear systems that arise when aquifer diffusivity is assumed constant in space and time. This assumption can be invalid in phreatic aquifers that experience spatiotemporal variation in the free surface position and consequent variation in saturated thickness. A weakly nonlinear approach to formulating and solving periodic flow problems in the frequency domain can be applied in situations where conventional linearized approximations break down. The weakly nonlinear equations provide robust approximations of the true nonlinear response and require much less computational effort and time to solve than the full nonlinear problem. Nondimensional rules of thumb are presented for choosing between linear, weakly nonlinear and nonlinear solution strategies.  相似文献   

19.
Sepúlveda N 《Ground water》2008,46(1):144-155
An analytical solution for three-dimensional (3D) flow in the storative semiconfining layers of a leaky aquifer fully penetrated by a production well is developed in this article to provide a method from which accurate hydraulic parameters in the semiconfining layers can be derived from aquifer test data. The analysis of synthetic aquifer test data with the 3D analytical solution in the semiconfining layers provided more accurate optimal hydraulic parameters than those derived using the available quasi-two-dimensional (2D) solution. Differences between the 3D and 2D flow solutions in the semiconfining layers become larger when a no flow boundary condition is imposed at either at the top of the upper semiconfining layer or at the bottom of the lower semiconfining layer or when the hydraulic conductivity ratio of the semiconfining layer to the aquifer is larger than 0.001. In addition, differences between the 3D and 2D flow solutions in the semiconfining layers are illustrated when the thickness ratio of the semiconfining layer to the aquifer is changed. Analysis of water level data from two hypothetical and one real aquifer test showed that the 3D solution in the semiconfining layers provides lower correlation coefficients among hydraulic parameters than the 2D solution.  相似文献   

20.
Geothermal activity may lead to convection currents in groundwater. Such currents considerably affect transport phenomena in the aquifer. In this study, the applicability of a seminumerical approach for the simulation of flow conditions in such an aquifer is presented. Flow field variables are expanded through truncated sets of eigenfunctions, which leads to a system of general first-order differential equations that can be solved by applying available subroutines. Criteria of flow field stability, parameters affecting flow conditions, and quantitative analysis of transport processes in the aquifer are studied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号