1.
Data are reported for rare earth elements (REE) in three geological glass reference materials (BIR-1G, BHVO-2G and BCR-2G) using a UV (266 nm) laser ablation ICP-MS system and the classical (HF-HClO4) acid decomposition method, followed by conventional nebulisation ICP-MS. External calibration of laser ablation analyses was performed using NIST SRM reference materials with internal standardisation using 29Si and 44Ca. Replicate analyses of reference basaltic glasses yielded an analytical precision of 1-5% (RSD) for all the elements by solution ICP-MS and 1-8% (RSD) by laser ablation ICP-MS. The relative differences between the REE concentrations measured by solution and laser ablation ICP-MS compared with the reference values were generally less than 11 % for most elements. The largest deviations occurred for La determined by solution ICP-MS in BIR-1G. The results of both solution and laser ablation ICP-MS agreed well, generally better than 7%, with the exception of La, Pr and Sm in BIR-1G. The measured REE laser ablation data for BIR-1G, BHVO-2G and BCR-2G agreed with the previously published data on these basaltic reference glasses, within a range of 0-10% for most elements. No significant influences were observed for the predicted spectral interferences on some REE isotopes in the analysis of basaltic glasses.  相似文献   

2.
New glass reference materials GSA-1G, GSC-1G, GSD-1G and GSE-1G have been characterised using a prototype solid state laser ablation system capable of producing wavelengths of 193 nm, 213 nm and 266 nm. This system allowed comparison of the effects of different laser wavelengths under nearly identical ablation and ICP operating conditions. The wavelengths 213 nm and 266 nm were also used at higher energy densities to evaluate the influence of energy density on quantitative analysis. In addition, the glass reference materials were analysed using commercially available 266 nm Nd:YAG and 193 nm ArF excimer lasers. Laser ablation analysis was carried out using both single spot and scanning mode ablation. Using laser ablation ICP-MS, concentrations of fifty-eight elements were determined with external calibration to the NIST SRM 610 glass reference material. Instead of applying the more common internal standardisation procedure, the total concentration of all element oxide concentrations was normalised to 100%. Major element concentrations were compared with those determined by electron microprobe. In addition to NIST SRM 610 for external calibration, USGS BCR-2G was used as a more closely matrix-matched reference material in order to compare the effect of matrix-matched and non matrix-matched calibration on quantitative analysis. The results show that the various laser wavelengths and energy densities applied produced similar results, with the exception of scanning mode ablation at 266 nm without matrix-matched calibration where deviations up to 60% from the average were found. However, results acquired using a scanning mode with a matrix-matched calibration agreed with results obtained by spot analysis. The increased abundance of large particles produced when using a scanning ablation mode with NIST SRM 610, is responsible for elemental fractionation effects caused by incomplete vaporisation of large particles in the ICP.  相似文献   

3.
《Applied Geochemistry》2004,19(3):289-322
The accurate recognition of tephra deposits is of great value to Earth scientists because they facilitate stratigraphic correlation. The most useful tephra deposits form from violent volcanic eruptions; they are isochronous and widespread. Most are dacitic and rhyolitic in composition, and can be difficult to identify unequivocally using major element chemistry alone. Distal tephras are typically thin and are prone to contamination and thus are awkward to analyse by bulk methods. Here, the authors review their previous work in the development of analytical techniques for the analysis of small volumes of glass separates from tephra deposits, both by solution nebulisation and by laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS), placing particular emphasis on the precision and accuracy of the various methods. In solution nebulisation ICP-MS, accurate data can be obtained from samples as small as 0.025 g. LA-ICP-MS methods are described for the analysis of small bulk samples and single glass shards as small as 40 μm in diameter. Accurate and reproducible analyses can be achieved by ICP-MS by both solution and laser ablation methods on homogeneous materials. Solution analyses are normally accurate to ±5% and have typical precisions (1 σ) of around ±4% for abundant trace elements (e.g. Zr, Rb) but this can deteriorate to about ±20% for rare elements in small samples (e.g. HREE in a 25 mg sample). Laser ablation methods are slightly less accurate (typically ±5–10%) and precision decreases from about ±3% at concentrations of a few hundred ppm, to about ±10% at 1 ppm and about ±30% at 0.05 ppm. An apparent lack of precision in the bulk analysis of small volumes of glass shards by LA-ICP-MS often represents within sample heterogeneity (and not analytical error), inter-shard variation becoming abundantly clear in some tephra deposits when individual glass shards are analysed. Single grain analysis on shards as small as 40 μm can provide an accurate analysis of the pure glass phase, which may not be achieved in solution or bulk sample LA-ICP-MS methods. Analyses affected by micro-phenocryst phases, such as feldspar or zircon can be easily removed following careful inspection of the data. Single shard LA-ICP-MS also allows any compositional variation within the parental magma to be defined.  相似文献   

4.
We report new data on the trace element concentrations of Mg, Cr, Mn, Co, Ni, Cu, Zn, Sr, Cd, Ba, La, Ce, Nd, Pb and U in USGS carbonate reference materials (MACS-1 and MACS-2) and compare solution ICP-MS and LA-ICP-MS trace element determinations on landfill calcites using calibration to different reference materials (MACS-1 and MACS-2 carbonate and NIST SRM 612 glass). Very good agreement (differences below 10% relative) was found between laser ablation and solution ICP-MS data for MACS-1 with higher concentrations of trace elements (values between 100 and 150 μg g−1), with the exception of Cu and Zn. Similarly good agreement was found for MACS-2 with lower trace element concentrations (units to tens of μg g−1), with the exception of Cr, Co and Zn. The MACS-1 reference material for calibration of LA-ICP-MS was found to be extremely useful for in situ determination of trace elements in real-world carbonate samples (landfill calcites), especially those present in calcite in higher concentrations (Mn, Sr, Ba; < 5% RSD). Less accurate determinations were generally obtained for trace elements present at low concentrations (∼ units of μg g−1). In addition, good agreement was observed between the instrument calibration to MACS and NIST SRM 612 glass for in situ measurements of trace elements in landfill calcites K-2, K-3 and K-4 (differences below 15% relative for most elements). Thus, the application of MACS carbonate reference materials is promising and points to the need for the development of new carbonate reference materials for laser ablation ICP-MS.  相似文献   

5.
LA‐ICP‐MS is one of the most promising techniques for in situ analysis of geological and environmental samples. However, there are some limitations with respect to measurement accuracy, in particular for volatile and siderophile/chalcophile elements, when using non‐matrix‐matched calibration. We therefore investigated matrix‐related effects with a new 200 nm femtosecond (fs) laser ablation system (NWRFemto200) using reference materials with different matrices and spot sizes from 10 to 55 μm. We also performed similar experiments with two nanosecond (ns) lasers, a 193 nm excimer (ESI NWR 193) and a 213 nm Nd:YAG (NWR UP‐213) laser. The ion intensity of the 200 nm fs laser ablation was much lower than that of the 213 nm Nd:YAG laser, because the ablation rate was a factor of about 30 lower. Our experiments did not show significant matrix dependency with the 200 nm fs laser. Therefore, a non‐matrix‐matched calibration for the multi‐element analysis of quite different matrices could be performed. This is demonstrated with analytical results from twenty‐two international synthetic silicate glass, geological glass, mineral, phosphate and carbonate reference materials. Calibration was performed with the certified NIST SRM 610 glass, exclusively. Within overall analytical uncertainties, the 200 nm fs LA‐ICP‐MS data agreed with available reference values.  相似文献   

6.
Laser ablation inductively coupled plasma mass spectrometry (LA‐ICP‐MS) is a high spatial resolution analytical method which has been applied to the analysis of silicic tephras. With current instrumentation, around 30 trace elements can be determined from single glass shards as small as ~ 40 µm, separated from tephra deposits. As a result of element fractionation during the ablation process using a 266 nm laser, a relatively complex calibration strategy is required. Nonetheless, such a strategy gives analyses which are accurate (typically within ±5%) and have an analytical precision which varies from ~ ±2% at 100 ppm, to ~ ±15% at 1 ppm. Detection limits for elements used in correlation and discrimination studies are well below 1 ppm. Examples of the application of trace element analysis by LA‐ICP‐MS in tephra studies are presented from the USA, New Zealand and the Mediterranean. Improvements in instrumental sensitivity in recent years have the potential to lower detection limits and improve analytical precision, thus allowing the analysis of smaller glass shards from more distal tephras. Laser systems operating at shorter wavelengths (e.g. 193 nm) are now more widely available, and produce a much more controllable ablation in glasses than 266 nm lasers. Crater sizes of <10 µm are easily achieved, and at 193 nm many of the elemental fractionation issues which mar longer wavelengths are overcome. By coupling a short wavelength laser to a modern ICP‐MS it should be possible to determine the trace element composition of glass shards as small as 20 µm and, providing sample preparation issues can be overcome, the determination of the more abundant trace elements in glass shards as small as 10 µm is within instrumental capabilities. This will make it possible to chemically fingerprint tephra deposits which are far from their sources, and will greatly extend the range over which geochemical correlation of tephras can be undertaken. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

7.
A new reference material, STDGL3, for the calibration of in situ analyses of sulfide minerals by LA-ICP-MS has been developed and characterised. It represents a lithium-borate-based glass containing a mixture of Zn- and Fe-sulfide concentrates doped with several chalcophile elements as well as Zr, Gd, Hf and Ta required for assessing common interferences on Ag, Au and Pt. STDGL3 has a wider range of elements and a better homogeneity compared with existing reference materials for LA-ICP-MS analysis of sulfides. Compositional variations for most elements are below 3% RSD, below 5% RSD for Ag, Au and Pt, and below 7% RSD for Se, when performing spot analyses with a 50 μm beam size. Its preparation recipe is reproducible allowing for multiple batches to be made. Use of STDGL3 significantly improves accuracy of sulfide mineral analysis by LA-ICP-MS when compared with use of other available reference materials. Performance of STDGL3 was evaluated using several different laser systems. No significant change was observed between 193 nm ArF excimer lasers with 5 and 20 ns pulse widths, but use of 213 and 248 nm lasers displays more systematic differences, especially when analysing galena. Correction coefficients are needed for some elements (Zn and Cd in particular) when analysing sulfide minerals using STDGL3 as a calibration reference material.  相似文献   

8.
The distinction between Ru in solid solution and Ru-bearing inclusions is essential for the predictive modeling of platinum-group element (PGE) geochemistry in applications such as the lithogeochemical exploration for magmatic sulfide deposits in komatiites. This study investigates the role of chromite in the fractionation of Ru in ultramafic melts by analyzing chromite grains from sulfide-undersaturated komatiites and a komatiitic basalt from the Yilgarn Craton in Western Australia. In situ analysis using laser ablation ICP-MS yields uniform Ru concentrations in chromites both within-grain and on a sample scale, with concentrations between 220 and 540 ppb. All other platinum-group elements are below the detection limit of the laser ablation ICP-MS analysis. Carius tube digestion isotope dilution ICP-MS analysis of chromite concentrates confirms the accuracy of the in-situ method. Time resolved laser ablation ICP-MS analyses have identified the presence of sub-micron Ir-bearing inclusions in some chromite grains from the komatiitic basalt. However, Ru-bearing inclusions have not been recognized in the analyzed chromites and this combined with the in situ data suggests that Ru exists in solid solution in the crystal lattice of chromite. These results show that chromite can control the fractionation and concentration of Ru in ultramafic systems.  相似文献   

9.
UV femtosecond laser ablation coupled to MC-ICP-MS provides a promising in situ tool to investigate elemental and isotope ratios by non-matrix-matched calibration. In this study, we investigate Fe isotope composition in siliceous matrices including biotite, hornblende, garnet, fayalite and forsterite (San Carlos Olivine), and an oceanic Fe–Mn crust using the iron reference material IRMM-014 for calibration. To test the accuracy of the laser ablation data, Fe isotope compositions were obtained independently by solution ICP-MS after chromatographic separation of Fe. Sample materials with low Cr content, i.e. biotite, hornblende, fayalite and the Fe–Mn crust, reveal δ56/54Fe and δ57/54Fe values that agree with those from solution ICP-MS data within the measured precision. For high Cr concentration (54Cr/54Fe >0.0001), i.e. in the garnet and forsterite sample, δ56/54Fe and δ57/54Fe values were derived from 57Fe/56Fe ratios as correction of the isobaric interference of 54Cr on 54Fe is unsatisfactory. This approach provides accurate results for both minerals. Moreover, the garnet crystal exhibits isotopic zonation with differences of 0.3‰ in δ56/54Fe showing that substantial heterogeneities exist in high-temperature metamorphic minerals. Multiple analyses of homogeneous sample materials reveal a repeatability of 0.1‰ (2 SD) for δ56/54Fe and 0.2‰ (2 SD) for δ57/54Fe, respectively. This study adds to the observations of Horn et al. (2006) who have shown that the determination of Fe isotope ratios in various matrices including iron alloys, iron oxides and hydroxides, iron sulfide and iron carbonates can be performed with high accuracy and precision at high spatial resolution using UV femtosecond laser ablation ICP-MS. These results demonstrate that femtosecond laser ablation ICP-MS is a largely matrix-independent method, which provides a substantial advantage over commonly employed nanosecond laser ablation systems.  相似文献   

10.
Recent developments from 2008 to 2009 in ICP-MS engineering, methods and applications are reviewed here. Of particular emphasis are advances in: (a) maximising sensitivity and reducing elemental/isotopic fractionation during laser ablation processing; (b) developing new analytical techniques to measure major, minor and trace element abundances without depending on matrix-matched calibrating materials, pre-determined internal standard concentrations and/or multiple analytical methods; (c) applying in situ and solution-based ICP-MS techniques to the analysis of forensic materials for criminal and/or nuclear investigations; and (d) improving precision and limits of detection of laser ablation multi-collector ICP-MS measurements of (ultra) trace elemental and isotopic abundances.  相似文献   

11.
激光剥蚀-电感耦合等离子体质谱(LA-ICP-MS)技术是目前最常用的锆石U-Pb同位素年龄测定方法之一。该方法能够对单颗粒锆石内部年龄差异实现快速、准确的原位微区分析。文章总结了近年来激光剥蚀系统、ICP-MS技术以及LA-ICP-MS锆石U-Pb定年方法、相关应用实例研究的进展和现状。系统评述了激光发生器,剥蚀池,剥蚀参数(激光波长、脉冲宽度、剥蚀气体、孔径大小)以及四极杆和扇形磁场质谱仪对锆石U-Pb年龄数据的精度和准确度的影响。详细介绍了基于锆石年龄标准样品、标准溶液及其他标样的外标定量校准方法,单个U/Pb比值计算方法,普通铅校正方法以及同位素年龄与微量元素同时测定的方法。目前LA-ICP-MS锆石U-Pb定年技术主要应用于碎屑锆石的沉积物源区示踪和岩浆事件的年代学约束研究。  相似文献   

12.
Laser ablation ICP-MS represents a promising new development for the acquisition of elemental and isotopic images from a variety of different materials. Compared to existing methods for imaging, it offers relatively rapid throughput, very wide dynamic range, a relatively clean mass spectrum, utility at a variety of scales (from μm to cm) and multi-element/isotopic capability. Although developing rapidly in the biological sciences, the method has not yet seen widespread application to geological materials. This contribution documents some preliminary experiments aimed at understanding the fundamental aspects of elemental and isotopic image acquisition using laser ablation ICP-MS. In particular, we note that ablation cell designs must be optimised to promote rapid system response, in contrast to the signal-smoothing that is often preferred for simple spot analyses. Furthermore, experimental parameters must be carefully evaluated on a system-by-system basis to avoid the blurring effects of re-sampling phenomena. With careful attention to these details, and development of appropriate data processing software, laser ablation ICP-MS imaging has much to offer workers in the Earth and environmental sciences.  相似文献   

13.
Direct analysis of geological reference materials was performed by LA-ICP-MS using two Nd:YAG laser systems operating at 266 nm and 1064 nm. The aim of this work was to compare UV and IR laser ablation and to assess the potential of the technique for the quantitative bulk analysis of rocks, sediments and soils. The laser sampling process was investigated and the analytical performance of both systems was compared. The influence of the laser operating conditions and the nature of the matrix on ICP-MS response factors calculated for major, minor and trace elements was evaluated. Under consistent laser settings, the response factors appeared to be matrix dependent. For a given matrix, the response factors were also significantly different for the two lasers. Normalisation with a single matrix element was effective only for matrices with similar mineralogy. When operating at 266 nm instead of 1064 nm, matrix effects could be reduced but not overcome. However, variations of the response factors between the different matrices appeared to be similar within distinct groups of elements, reflecting geochemical associations. When using multiple internal standards, matrix effects but also effects of the laser wavelength, could be fully compensated.  相似文献   

14.
激光剥蚀-等离子体质谱(LA-ICPMS)已成为地球化学、宇宙化学和环境研究领域元素和同位素原位分析最重要的技术之一。文章介绍了多种类型的质谱仪及其使用的激光器。用途最广的LA-ICPMS仪器之一是单接收器扇形磁场质谱仪,配有Nd:YAG激光剥蚀系统(激光波长分为193 nm和213 nm两种),MPI Mainz实验室使用的就是这套系统,文章对此作一详细介绍。文中阐述了数据优化技术及其多种校正过程;介绍LA-ICPMS在痕量元素和同位素分析领域的一些应用,包括参考物质的研制,Hawaiian玄武岩、Martian陨石、生物骨针和珊瑚虫中痕量元素分析及熔融包裹体和富钙-铝碳质球粒陨石中的铅和锶同位素测量。  相似文献   

15.
LA‐ICP‐MS is increasingly applied to obtain quantitative multi‐element data with minimal sample preparation, usually achieved by calibration using reference materials (RMs). However, some ubiquitous RMs, for example the NIST SRM 61× series glasses, suffer from reported value uncertainties for certain elements. Moreover, no long‐term data set of analyses conducted over a range of ablation and tuning conditions exists. Thus, there has been little rigorous examination of the extent to which offsets between measured and reported values are the result of error in these values rather than analytically induced fractionation. We present new software (‘LA‐MINE’), capable of extracting LA‐ICP‐MS data with no user input, and apply this to our system, yielding over 5 years of data (~ 5700 analyses of ten glass and carbonate RMs). We examine the relative importance of systematic analytical bias and possible error in reported values through a mass‐specific breakdown of fourteen of the most commonly determined elements. Furthermore, these data, obtained under a wide range of different ablation conditions, enable specific recommendations of how data quality may be improved, for example the role of diatomic gas, the effect of differential inter‐glass fractionation factors and choice of transport tubing material. Finally, these data demonstrate that the two‐volume Laurin ablation cell is characterised by no discernible spatial heterogeneity in measured trace element ratios.  相似文献   

16.
Seven ilmenite (FeTiO3) megacrysts derived from alnöite pipes (Island of Malaita, Solomon Islands) were characterised for their major and trace element compositions in relation to their potential use as secondary reference materials for in situ microanalysis. Abundances of thirteen trace elements obtained by laser ablation ICP‐MS analyses (using the NIST SRM 610 glass reference material) were compared with those determined by solution‐mode ICP‐MS measurements, and these indicated good agreement for most elements. The accuracy of the LA‐ICP‐MS protocol employed here was also assessed by repeated analysis of MPI‐DING international glass reference materials ML3B‐G and KL2‐G. Several of the Malaitan ilmenite megacrysts exhibited discrepancies between laser ablation and solution‐mode ICP‐MS analyses, primarily attributed to the presence of a titano‐magnetite exsolution phase (at the grain boundaries), which were incorporated solely in the solution‐mode runs. Element abundances obtained by LA‐ICP‐MS for three of the ilmenite megacrysts (CRN63E, CRN63H and CRN63K) investigated here had RSD (2s) values of < 20% and therefore can be considered as working values for reference purposes during routine LA‐ICP‐MS analyses of ilmenite.  相似文献   

17.
The determination of accurate Sr isotope ratios in calcium phosphate matrices by laser ablation multi-collector ICP-MS is demonstrated as possible even with low Sr concentration archaeological material. Multiple on-line interference correction routines for doubly-charged REE, Ca dimers and Rb with additional calibration against TIMS-characterised materials are required to achieve this. The calibration strategy proposed uses both inorganic and biogenic apatite matrices to monitor and correct for a 40Ca-31P-16O polyatomic present at levels of 0.3-1% of the non-oxide peak, which interferes on 87Sr causing inaccuracies of 0.03-0.4% in the 87Sr/86Sr isotope ratio. The possibility also exists for synthetic materials to be used in this calibration. After correction for interferences total combined uncertainties of 0.04-0.15% (2SD) are achieved for analyses of 13-24 μg of archaeological tooth enamel with Sr concentrations of ca. 100-500 ppm using MC-ICP-MS. In particular, for samples containing >300 ppm Sr, total uncertainties of ∼0.05% are possible utilising 7-12 ng Sr. Data quality is monitored by determination of 84Sr/86Sr ratios.When applied to an archaeological cattle tooth this approach shows Sr-isotope variations along the length of the tooth in agreement with independent TIMS data. The 40Ca-31P-16O polyatomic interference is the root cause of the bias at mass 87 during laser ablation ICP-MS analysis of inorganic and biogenic calcium phosphate (apatite) matrices. This results in inaccurate 87Sr/86Sr ratios even after correction of Ca dimers and doubly charged rare earth elements. This interference is essentially constant at specific ablation conditions and therefore the effect on 87Sr/86Sr data varies in proportion to changes in the Sr concentration of the ablated material. Complete elimination of this interference is unlikely through normal analytical mechanisms and therefore represents a limitation on the achievable accuracy of LA-(MC-)ICP-MS 87Sr/86Sr data without rigorous calibration to known reference materials.  相似文献   

18.
The analytical capabilities of laser ablation (LA)-ICP-MS in determining Li, Be and B at trace levels in geological samples have been tested on a series of glass reference materials and natural samples. The LA-ICP-MS instrument used consisted of a sector-field ICP-MS coupled with a laser ablation microprobe operating at either 266 or 213 nm wavelength. Reference glasses from NIST (SRM 612, 614 and 616) and MPI-DING (KL2-G, ML3B-G, StHs6/80-G, GOR128-G, GOR132-G, T1-G and ATHO-G) were selected to develop the analytical method and to assess the best instrumental configuration. A series of calcic amphiboles with different Li, Be and B concentrations were also analysed using both LA-ICP-MS and SIMS to test the applicability of the method to natural minerals. Results indicated that with a spot size of 40 μm the agreement between measured and reference values of Li, Be and B is generally better than 10% for NIST SRM 612 and 20% for NIST SRM 614. Average reproducibility at the 2s level was 10% for Li, 20% for Be and 15% for B. Limits of detection were approximately 100 ng g-1 for Be and B and 200 ng g-1 for Li. These results were confirmed by analyses carried out on natural amphiboles and compared well in terms of precision and accuracy with those commonly achieved by SIMS.  相似文献   

19.
Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to determine K, Sc, Ti, V, Cr, Mn, Co, Ni and Zn in geological samples. Because the isotopes of these elements and the internal standard element (Ca) often have interferences from molecular ions when determined using quadrupole or sector-field ICP-MS in low mass resolution mode, ion intensities were measured at a high mass resolution of 4000. We investigated dynamic element fractionation, type and abundance of molecular ions using different geological reference materials. Highly resolved mass spectra were especially important for accurate low-abundance measurements. As a result, maximum "critical" concentration limits for each isotope were obtained, where a mass resolution of 4000 was necessary for reliable LA-ICP-MS analysis. To test the LA-ICP-MS technique, different international reference material glasses and powdered rock reference materials were analysed. Rock powders were fused to glass beads using an Ir-strip heater. Nearly all concentration values for the reference materials agreed with the reference values at the 95% confidence level. To demonstrate routine LA-ICP-MS analysis at a mass resolution of 4000, trace element data for Hawaiian basalts are also presented.  相似文献   

20.
The direct analysis of nickel sulfide fire assay buttons by UV laser ablation ICP-MS was used to determine the platinum-group elements and gold in the following reference materials: UMT-1, WPR-1, WMG-1, GPt-4, GPt-6 and CHR-Bkg. The instrument was calibrated with buttons prepared using quartz doped with the appropriate standard solutions. Analytical precision (RSD) was generally better than 10%, although occasional higher RSDs may infer local heterogeneities within nickel sulfide buttons. Good or excellent agreement was observed between analysed and reference material values except Rh in UMT-1 and WMG-1, which suffered an interference from copper. Detection limits calculated as 10 s quantitation limits were Au (1.7 ng g−1), Pd (3.3 ng g−1), Pt (8.3 ng g−1), Os (1.3 ng g−1), Rh (1 ng g−1), Ru (5 ng g−1) and Ir (0.7 ng g−1).  相似文献   