1.
Seismic performance attributes of multi‐story passive and semi‐active tuned mass damper (PTMD and SATMD) building systems are investigated for 12‐story moment resisting frames modeled as ‘10+2’ stories and ‘8+4’ stories. Segmented upper portion of the stories are isolated as a tuned mass, and a passive viscous damper or semi‐active resetable device is adopted as energy dissipation strategy. The semi‐active approach uses feedback control to alter or manipulate the reaction forces, effectively re‐tuning the system depending on the structural response. Optimum tuned mass damper control parameters and appropriate matching SATMD configurations are adopted from a companion study on a simplified two‐degree‐of‐freedom system. Statistical performance metrics are presented for 30 probabilistically scaled earthquake records from the SAC project. Time history analyses are used to compute response reduction factors across a wide range of seismic hazard intensities. Results show that large SATMD systems can effectively manage seismic response for multi‐degree‐of freedom systems across a broad range of ground motions in comparison to passive solutions. Specific results include the identification of differences in the mechanisms by which SATMD and PTMD systems remove energy, based on the differences in the devices used. Additionally, variability is seen to be tighter for the SATMD systems across the suites of ground motions used, indicating a more robust control system. While the overall efficacy of the concept is shown the major issues, such as isolation layer displacement, are discussed in detail not available in simplified spectral analyses, providing further insight into the dynamics of these issues for these systems. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
A tuned mass damper (TMD) system consists of an added mass with properly functioning spring and damping elements for providing frequency‐dependent damping in a primary structure. The advantage of a friction‐type TMD, that is, a nonlinear TMD, is its energy dissipation via a friction mechanism. In contrast, the disadvantages of a passive friction TMD (PF‐TMD) are its fixed and predetermined slip load and loss of tuning and energy dissipation capabilities when it is in a stick state. A semi‐active friction TMD (SAF‐TMD) is used to overcome these disadvantages. The SAF‐TMD can adjust its slip force in response to structure motion. To verify its feasibility, a prototype SAF‐TMD was fabricated and tested dynamically using a shaking table test. A nonsticking friction control law was used to keep the SAF‐TMD activated and in a slip state in earthquakes at varying intensities. The shaking table test results demonstrated that: (i) the experimental results are consistent with the theoretical results; (ii) the SAF‐TMD is more effective than the PF‐TMD given a similar peak TMD stroke; and (iii) the SAF‐TMD can also prevent a residual TMD stroke in a PF‐TMD system. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
This research investigates the development of a semi‐active piezoelectric friction damper for controlling the seismic response of large‐scale structures. The proposed device is made of Duplex steel and leads to high friction capacity, which can be developed either in passive or semi‐active modes. For the later, piezoelectric actuators react against a stiff clamping system and apply a variable normal force on the multiple contact surfaces. To validate the design, a prototype, which contact surfaces were made of stainless steel and brake pad material, was built and tested in both friction modes. Moreover, an analytical model of the damper was developed to estimate the performance of the piezoelectric actuators within the clamping system. Experimental results showed that the proposed device achieves a force range factor of 1.9. These experimental results also compare well with those obtained from the analytical model of the damper. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
It is impractical to install sensors on every floor of a tall building to measure the full state vector because of the large number of degrees of freedom. This makes it necessary to introduce reduced‐order control. A kind of system reduction scheme (dynamic condensation method) is proposed in this paper. This method is iterative and Guyan condensation is looked upon as an initial approximation of the iteration. Since the reduced‐order system is updated repeatedly until a desired one is obtained, the accuracy of the reduced‐order system resulting from the proposed method is much higher than that obtained from the Guyan condensation method. Another advantage of the method is that the reduced‐order system is defined in the subspace of the original physical space, which makes the state vectors have physical meaning. An eigenvalue shifting technique is applied to accelerate the convergence of iteration and to make the reduced system retain all the dynamic characteristics of the full system within a given frequency range. Two schemes to establish the reduced‐order system by using the proposed method are also presented and discussed in this paper. The results for a tall building with active tuned mass damper show that the proposed method is efficient for the reduced‐order modelling and the accuracy is very close to exact only after two iterations. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

5.
A magneto‐rheological (MR) damper is a semi‐active device where the damper force capacity is controlled by varying the input current into the damper. In this paper, the dynamics of MR dampers associated with variable current input is studied. Electromagnetic theory is used to model the dynamics of an MR damper including the eddy current effect and the nonlinear hysteretic behavior of damper material magnetization. A nonlinear differential equation that relates the input current to the damper with a constant equivalent current is proposed. The nonlinear differential equation is combined with the Maxwell Nonlinear Slider (MNS) model to create the variable current MNS model to predict the damper force under variable input current and random damper displacement loading. The model is evaluated by comparing the predicted response of a large‐scale MR damper to the measured damper response from experiments. The experiments include a real‐time hybrid simulation of a 3‐story building structure with a large‐scale MR damper subjected to the design earthquake. The exceptional agreement observed between the predicted and experimental results illustrate the robustness and the accuracy of the variable current MNS model. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A continuously variable semi‐active damper is used in a tuned mass damper (TMD) to reduce the level of vibration of a single‐degree‐of‐freedom system subjected to harmonic base excitations. The ground hook dampers as have been used in the auto‐industry are being studied here. Using these dampers a new class of tuned mass dampers, named as ground hook tuned mass dampers (GHTMD) is being introduced. In order to generalize the design properties of the GHTMDs, they are defined in terms of non‐dimensional parameters. The optimum design parameters of GHTMDs for lightly damped systems are obtained based on the minimization of the steady‐state displacement response of the main mass. These parameters are computed for different mass ratios and main system damping ratios. Frequency responses of the resulting systems are compared to that of equivalent TMDs using passive dampers. In addition, other characteristics of this system as compared to the passive TMDs are discussed. A design guide to obtain the optimum parameters of GHTMD using the developed diagrams in this paper based on non‐dimensional values is presented. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

7.
8.
Optimal displacement feedback control law is derived for a vibration control of a single‐degree‐of‐freedom structure with an active tuned mass damper (ATMD). Analytical expressions of the linear quadratic regulator (LQR) feedback gains for the ATMD are derived by solving the Ricatti equation straightforwardly. Based on these solutions, it is found that if the stiffness of the tuned mass damper (TMD) is calibrated to satisfy a certain condition, the control law is simplified to be composed of the feedback gains only for the displacement of the structure and the velocity of the auxiliary mass stroke, which is referred to as ‘optimal displacement feedback control’. The mean‐square responses of the structure as well as the auxiliary mass against Gaussian white noise excitations are evaluated by solving the Lyapunov equation analytically based on the stochastic optimal control theory. Using these analytical solutions, the optimal damping parameter for the auxiliary mass is also derived. Finally, the optimal displacement feedback control law is presented. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

9.
The authors developed a semi‐active hydraulic damper (SHD) and installed it in an actual building in 1998. This was the first application of a semi‐active structural control system that can control a building's response in a large earthquake by continuously changing the device's damping coefficient. A forced vibration test was carried out by an exciter with a maximum force of 100 kN to investigate the building's vibration characteristics and to determine the system's performance. As a result, the primary resonance frequency and the damping ratio of a building that the SHDs were not jointed to, decreased as the exciting force increased due to the influence of non‐linear members such as PC curtain walls. The equivalent damping ratio was estimated by approximating the resonance curves using the steady‐state response of the SDOF bilinear hysteretic system. After the eight SHDs were jointed to the building, the system's performance was identified by a response control test for steady‐state vibration. The elements that composed the semi‐active damper system demonstrated the specified performance and the whole system operated well. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

10.
Floor isolation system (FIS) achieving very small floor accelerations has been used to ensure human comfortability or protect important equipments in buildings. Tuned mass damper (TMD) with large mass ratios has been demonstrated to be robust with respect to the changes in structural properties. This paper presents the concept of a TMD floor vibration control system, which takes advantages of both the FIS and TMD. Such a system is called ‘TMD floor system’ herein. The TMD floor system (TMDFS) in which building floors serve as TMDs can achieve large mass ratio without additional masses. Furthermore, multiple TMD floors installed in a building can control multimode vibrations. Then, an optimal design process, where the objective function is set as the maximum magnitude of the frequency response functions of inter‐storey drifts, is proposed to determine the TMD floor parameters. Additionally, the multimode approach is applied to determine the optimal locations of TMD floors if not all of the floors in a building can serve as TMDs. In addition to the numerical simulations, a scaled model shaking table experiment is also conducted. Both the numerical and experimental results show that the absolute accelerations of the TMD floors are smaller than those of the main structural storeys, which indicates the TMDFS maintains the merit of FIS while greatly reducing seismic responses of main structures. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
A semi‐active multi‐step predictive control (SAMPC) system with magnetorheological (MR) dampers is developed to reduce the seismic responses of structures. This system can predict the next multi‐step responses of structure according to the current state and has a function of self‐compensation for time delay that occurred in real application. To study the performance of the proposed control algorithm for addressing time delay and reducing the seismic responses, a numerical example of an 11‐story structure with MR dampers is presented. Comparison with the uncontrolled structure indicates that both the peak and the norm values of structural responses are all clearly reduced when the predictive length l?10 and the delayed time step d?20 are selected, and the SAMPC strategy can guarantee the stability of the controlled structure and reduce the effects of time delay on controlled responses to a certain extent. A performance comparison is also made between the SAMPC strategy and the passive‐off and passive‐on methods; results indicate that this SAMPC system is more effective than the two passive methods in reducing structural responses subjected to earthquakes. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
This paper proposes bi‐directional coupled tuned mass dampers (BiCTMDs) for the seismic response control of two‐way asymmetric‐plan buildings subjected to bi‐directional ground motions. The proposed BiCTMD was developed from the three‐degree‐of‐freedom modal system, which represents the vibration mode of a two‐way asymmetric‐plan building. The performance of the proposed BiCTMD for the seismic response control of elastic two‐way asymmetric‐plan buildings was verified by investigating the reductions of the amplitudes of the associated frequency response functions. In addition, the investigation showed that the proposed BiCTMD is effective in reducing the seismic damage of inelastic asymmetric‐plan buildings. Therefore, the BiCTMD is an effective approach for the seismic response control of both elastic and inelastic two‐way asymmetric‐plan buildings. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
Although the design and applications of linear tuned mass damper (TMD) systems are well developed, nonlinear TMD systems are still in the developing stage. Energy dissipation via friction mechanisms is an effective means for mitigating the vibration of seismic structures. A friction‐type TMD, i.e. a nonlinear TMD, has the advantages of energy dissipation via a friction mechanism without requiring additional damping devices. However, a passive‐friction TMD (PF‐TMD) has such disadvantages as a fixed and pre‐determined slip load and may lose its tuning and energy dissipation abilities when it is in the stick state. A novel semi‐active‐friction TMD (SAF‐TMD) is used to overcome these disadvantages. The proposed SAF‐TMD has the following features. (1) The frictional force of the SAF‐TMD can be regulated in accordance with system responses. (2) The frictional force can be amplified via a braking mechanism. (3) A large TMD stroke can be utilized to enhance control performance. A non‐sticking friction control law, which can keep the SAF‐TMD activated throughout an earthquake with an arbitrary intensity, was applied. The performance of the PF‐TMD and SAF‐TMD systems in protecting seismic structures was investigated numerically. The results demonstrate that the SAF‐TMD performs better than the PF‐TMD and can prevent a residual stroke that may occur in a PF‐TMD system. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
以一座矮塔斜拉桥为研究对象,分析碰撞调谐质量阻尼器对于该结构的抑震效果。首先介绍了新型碰撞调谐质量阻尼器(Pounding Tuned Mass Damper,PTMD)的减震机理及基于接触单元的非线性碰撞力模型;之后,通过ANSYS软件中的APDL语言实现了PTMD减震系统的时域分析方法,并通过三条实际地震记录验证了PTMD的抑震效果。数值分析结果表明:(1)传统调谐质量阻尼器(tuned mass damper,TMD)及新型PTMD对于矮塔斜拉桥的位移、加速度及塔身弯矩响应均有较好的抑制效果;(2)PTMD相比传统TMD多了一种碰撞耗能模式,其减震效果略高于传统TMD。  相似文献   

15.
基于我国现行的风荷载规范,建立了在风荷载作用下结构-主动调谐质量阻尼器(ATMD)系统的动力方程。定义ATMD最优参数准则为:结构-ATMD系统的位移或加速度响应方差的最小化。ATMD有效性的评价准则为:设置ATMD结构的最小化位移或加速度响应方差与未设置ATMD结构的位移或加速度响应方差之比(分别称为位移和加速度减振系数)。根据上述准则,在频域内数值研究了结构自振频率、标准化加速度反馈增益系数、质量比对ATMD系统的最优参数(包括最优频率比和阻尼比)、有效性和冲程的影响。此外,为了比较的目的,论文同时考虑了结构TMD风致振动控制的情况。  相似文献   

16.
SATMD与消能减震相结合的混合控制研究   总被引:1,自引:0,他引:1  
根据模糊控制理论及抗震结构混合控制理论,利用自行设计的模糊控制器对波动调谐质量阻尼器(PTMD)子结构进行调谐控制以实现半自动化,同时在主结构上进行粘弹性阻尼器的优化设置,从而实现结构体系的多模态优化混合控制,最后提出半主动调谐质量阻尼器(SATMD)与消能减震相结合的混合控制实用设计方法。本文对推动结构混合控制理论的发展具有重要意义。  相似文献   

17.
A semi‐active fuzzy control strategy for seismic response reduction using a magnetorheological (MR) damper is presented. When a control method based on fuzzy set theory for a structure with a MR damper is used for vibration reduction of a structure, it has an inherent robustness, and easiness to treat the uncertainties of input data from the ground motion and structural vibration sensors, and the ability to handle the non‐linear behavior of the structure because there is no longer the need for an exact mathematical model of the structure. For a clipped‐optimal control algorithm, the command voltage of a MR damper is set at either zero or the maximum level. However, a semi‐active fuzzy control system has benefit to produce the required voltage to be input to the damper so that a desirable damper force can be produced and thus decrease the control force to reduce the structural response. Moreover, the proposed control strategy is fail‐safe in that the bounded‐input, bounded‐output stability of the controlled structure is guaranteed. The results of the numerical simulations show that the proposed semi‐active control system consisting of a fuzzy controller and a MR damper can be beneficial in reducing seismic responses of structures. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

18.
为了改良被动式调谐质量阻尼器(TMD)对建筑结构的减震效果,本文提出了一种新型的可实时调节频率和电涡流阻尼的半主动调谐质量阻尼器(SATMD)。由Hilbert-Huang变换(HHT)识别出结构的瞬时频率,通过基于HHT的控制算法实时调节SATMD的质量进行频率的调谐;通过基于线性二次型高斯(LQG)的控制算法实时调整磁导间距来调节电涡流阻尼系数。为了验证SATMD对建筑结构的减震效果,以一单自由度结构模型为例进行地震响应模拟,同时采用一经优化设计的被动TMD作为对比,并考虑由于主结构的累积损伤等引起自身频率下降而造成被动TMD的去谐效应。以主结构的加速度和位移时程峰值、整体均方根值及TMD的耗能性能作为评价指标,对比了SATMD在主结构发生损伤前后对被动TMD的改良效果。数值模拟结果表明,在主结构发生损伤前后,SATMD均比经优化设计的被动TMD有更好的减震效果及耗能能力。  相似文献   

19.
Vibration mitigation using smart, reliable and cost‐effective mechanisms that requires small activation power is the primary objective of this paper. A semi‐active controller‐based neural network for base‐isolation structure equipped with a magnetorheological (MR) damper is presented and evaluated. An inverse neural network model (INV‐MR) is constructed to replicate the inverse dynamics of the MR damper. Next, linear quadratic Gaussian (LQG) controller is designed to produce the optimal control force. Thereafter, the LQG controller and the INV‐MR models are linked to control the structure. The coupled LQG and INV‐MR system was used to train a semi‐active neuro‐controller, designated as SA‐NC, which produces the necessary control voltage that actuates the MR damper. To evaluate the proposed method, the SA‐NC is compared to passive lead–rubber bearing isolation systems (LRBs). Results revealed that the SA‐NC was quite effective in seismic response reduction for wide range of motions from moderate to severe seismic events compared to the passive systems. In addition, the semi‐active MR damper enjoys many desirable features, such as its inherent stability, practicality and small power requirements. The effectiveness of the SA‐NC is illustrated and verified using simulated response of a six‐degree‐of‐freedom model of a base‐isolated building excited by several historical earthquake records. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

20.
In this paper, the effectiveness of different design solutions for tuned mass dampers (TMD) applied to high‐rise cross‐laminated (X‐Lam) timber buildings as a means to reduce the seismic accelerations was investigated. A seven‐storey full‐scale structure previously tested on shaking table was used as a reference. The optimal design parameters of the TMDs, i.e. damping and frequency ratios, were determined by using a genetic algorithm on a simplified model of the reference structure, composed by seven masses each representing one storey. The optimal solutions for the TMDs were then applied to a detailed finite element model of the seven‐storey building, where the timber panels were modelled with shell elements and the steel connectors with linear spring. By comparing the numerical results of the building with and without multiple TMDs, the improvement in seismic response was assessed. Dynamic time‐history analyses were carried out for a set of seven natural records, selected in accordance with Eurocode 8, on the simplified model, and for Kobe earthquake ground motion on the detailed model. Results in terms of acceleration reduction for different TMD configurations show that the behaviour of the seven‐storey timber building can be significantly improved, especially at the upper storeys. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   