共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A non‐parametric statistical method of tracking rapidly changing dynamical systems is introduced. The method implements the non‐linear wavelet thresholding estimator to estimate the evolutionary transfer function of the system. The consistency and optimality of the resulting estimate of our method on rapidly changing systems are stated, while no linear estimator can achieve the same optimality. Two examples of real data are studied using this non‐parametric method, including two vertical seismic array case studies and a series of seismic slope experiments. The analysis results are consistent with previous research for the vertical seismic array data. Moreover, our estimate is superior to those from previous research in the sense that our estimate is neither over‐smoothed nor under‐smoothed. The ana‐ lysis results are also consistent with the experimental observations for the seismic slope experimental data. Copyright © 2003 John Wiley & Sons, Ltd. 相似文献
3.
A structure's health or level of damage can be monitored by identifying changes in structural or modal parameters. This research directly identifies changes in structural stiffness due to modelling error or damage for a post‐tensioned pre‐cast reinforced concrete frame building with rocking beam column connections and added damping and stiffness (ADAS) elements. A structural health monitoring (SHM) method based on adaptive least mean squares (LMS) filtering theory is presented that identifies changes from a simple baseline model of the structure. This method is able to track changes in the stiffness matrix, identifying when the building is (1) rocking, (2) moving in a hybrid rocking–elastic regime, or (3) responding linearly. Results are compared for two different LMS‐based SHM methods using an L 2 error norm metric. In addition, two baseline models of the structure, one using tangential stiffness and the second a more accurate bi‐linear stiffness model, are employed. The impact of baseline model complexity is then delineated. The LMS‐based methods are able to track the non‐linearity of the system to within 15% using this metric, with the error due primarily to filter convergence rates as the structural response changes regimes while undergoing the El Centro ground motion record. The use of a bi‐linear baseline model for the SHM problem is shown to result in error metrics that are at least 50% lower than those for the tangential baseline model. Errors of 5–15% with this L 2 error norm are fairly stringent compared to the greater than 2 × changes in stiffness undergone by the structure, however, in practice the usefulness of the results is dependent on the resolution required by the user. The impact of sampling rate is shown to be negligible over the range of 200–1000Hz, along with the choice of LMS‐based SHM method. The choice of baseline model and its level of knowledge about the actual structure is seen to be the dominant factor in achieving good results. The methods presented require 2.8–14.0 Mcycles of computation and therefore could easily be implemented in real time. Copyright © 2005 John Wiley & Sons, Ltd. 相似文献
4.
The seismic response of single‐degree‐of‐freedom (SDOF) systems incorporating flag‐shaped hysteretic structural behaviour, with self‐centring capability, is investigated numerically. For a SDOF system with a given initial period and strength level, the flag‐shaped hysteretic behaviour is fully defined by a post‐yielding stiffness parameter and an energy‐dissipation parameter. A comprehensive parametric study was conducted to determine the influence of these parameters on SDOF structural response, in terms of displacement ductility, absolute acceleration and absorbed energy. This parametric study was conducted using an ensemble of 20 historical earthquake records corresponding to ordinary ground motions having a probability of exceedence of 10% in 50 years, in California. The responses of the flag‐shaped hysteretic SDOF systems are compared against the responses of similar bilinear elasto‐plastic hysteretic SDOF systems. In this study the elasto‐plastic hysteretic SDOF systems are assigned parameters representative of steel moment resisting frames (MRFs) with post‐Northridge welded beam‐to‐column connections. In turn, the flag‐shaped hysteretic SDOF systems are representative of steel MRFs with newly proposed post‐tensioned energy‐dissipating connections. Building structures with initial periods ranging from 0.1 to 2.0s and having various strength levels are considered. It is shown that a flag‐shaped hysteretic SDOF system of equal or lesser strength can always be found to match or better the response of an elasto‐plastic hysteretic SDOF system in terms of displacement ductility and without incurring any residual drift from the seismic event. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
5.
This paper addresses the problem of identification of the modal parameters for a structural system using measured non‐stationary response time histories only. A Bayesian time‐domain approach is presented which is based on an approximation of the probability distribution of the response to a non‐stationary stochastic excitation. It allows one to obtain not only the most probable values of the updated modal parameters and stochastic excitation parameters but also their associated uncertainties using only one set of response data. It is found that the updated probability distribution can be well approximated by a Gaussian distribution centred at the most probable values of the parameters. Examples using simulated data are presented to illustrate the proposed method. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
6.
The causal and physically realizable Biot hysteretic model proves to be the simplest linear model able to describe the nearly rate‐independent behaviour of engineering materials. In this paper, the performance of the Biot hysteretic model is analysed and compared with those of the ideal and causal hysteretic models. The Laguerre polynomial approximation (LPA) method, recently proposed for the time‐domain analysis of linear viscoelastic systems, is then summarized and applied to the prediction of the dynamic response of linear hysteretic systems to deterministic and random excitations. The parameters of the LPA model generally need to be computed through numerical integrals; however, when this model is used to approximate the Biot hysteretic model, closed‐form expressions can be found. Effective step‐by‐step procedures are also provided in the paper, which prove to be accurate also for high levels of damping. Finally, the method is applied to the dynamic analysis of a highway embankment excited by deterministic and random ground motions. The results show that in some cases the inaccuracy associated with the use of an equivalent viscous damping model is too large. Copyright © 2005 John Wiley & Sons, Ltd. 相似文献
7.
In many parts of the world, the repetition of medium–strong intensity earthquake ground motions at brief intervals of time has been observed. The new design philosophies for buildings in seismic areas are based on multi‐level design approaches, which take into account more than a single damageability limit state. According to these approaches, a sequence of seismic actions may produce important consequences on the structural safety. In this paper, the effects of repeated earthquake ground motions on the response of single‐degree‐of‐freedom systems (SDOF) with non‐linear behaviour are analysed. A comparison is performed with the effect of a single seismic event on the originally non‐damaged system for different hysteretic models in terms of pseudo‐acceleration response spectra, behaviour factor q and damage parameters. The elastic–perfect plastic system is the most vulnerable one under repeated earthquake ground motions and is characterized by a strong reduction of the q‐factor. A moment resisting steel frame is analysed as well, showing a reduction of the q‐factor under repeated earthquake ground motions even larger than that of an equivalent SDOF system. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
8.
The steady‐forced and earthquake responses of SDF systems with a non‐linear fluid viscous damper (FVD) are investigated. The energy dissipation capacity of the FVD is characterized by the supplemental damping ratio ζsd and its non‐linearity by a parameter designated α. It is found that the structural response is most effectively investigated in terms of ζsd and α because (1) these two parameters are dimensionless and independent, and (2) the structural response varies linearly with the excitation intensity. Damper non‐linearity has essentially no influence on the peak response of systems in the velocity‐sensitive spectral region, but differences up to 14% were observed in the other spectral regions. The structural deformation is reduced by up to 25% when ζsd= 5%; and by up to 60% when ζsd= 30%. Non‐linear FVDs are advantageous because they achieve essentially the same reduction in system responses but with a significantly reduced damper force. For practical applications, a procedure is presented to estimate the design values of structural deformation and forces for a system with non‐linear FVD directly from the design spectrum. It is demonstrated that the earthquake‐induced force in a non‐linear FVD can be estimated from the damper force in a corresponding system with linear FVD, its peak deformation, and peak relative velocity; however, the relative velocity should not be approximated by the pseudo‐velocity as this approximation introduces a large error in the damper force. Finally, a procedure is presented to determine the non‐linear damper properties necessary to limit the structural deformation to some design value or the structural capacity for a given design spectrum. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
9.
10.
Rakesh K. Goel 《地震工程与结构动力学》2005,34(7):825-846
This investigation is concerned with the seismic response of one‐story, one‐way asymmetric linear and non‐linear systems with non‐linear fluid viscous dampers. The seismic responses are computed for a suite of 20 ground motions developed for the SAC studies and the median values examined. Reviewed first is the behaviour of single‐degree‐of‐freedom systems to harmonic and earthquake loading. The presented results for harmonic loading are used to explain a few peculiar trends—such as reduction in deformation and increase in damper force of short‐period systems with increasing damper non‐linearity—for earthquake loading. Subsequently, the seismic responses of linear and non‐linear asymmetric‐plan systems with non‐linear dampers are compared with those having equivalent linear dampers. The presented results are used to investigate the effects of damper non‐linearity and its influence on the effects of plan asymmetry. Finally, the design implications of the presented results are discussed. Copyright © 2005 John Wiley & Sons, Ltd. 相似文献
11.
Buildings are continually subject to dynamic loads, such as wind load, seismic ground motion, and even the load from internal utility machines. The recent trend of constructing more flexible high‐rise buildings underscores the importance of including viscoelastic dampers in building designs. Viscoelastic dampers are used to control the dynamic response of a building. If the seismic design is based only on the linear response spectrum, considerable error may occur when calculating the seismic response of a building; rubber viscoelastic dampers show non‐linear hysteretic damping that is quite different from viscous damping. This study generated a non‐linear response spectrum using a non‐linear oscillator model to simulate a building with viscoelastic dampers installed. The parameters used in the non‐linear damper model were obtained experimentally from dynamic loading tests. The results show that viscoelastic dampers effectively reduce the seismic displacement response of a structure, but transmit more seismic force to the structure, which essentially increases its seismic acceleration response. Copyright © 2003 John Wiley & Sons, Ltd. 相似文献
12.
A predictor‐multicorrector implementation of a Time Discontinuous Galerkin method for non‐linear dynamic analysis is described. This implementation is intended to limit the high computational expense typically required by implicit Time Discontinuous Galerkin methods, without degrading their accuracy and stability properties. The algorithm is analysed with reference to conservative Duffing oscillators for which closed‐form solutions are available. Therefore, insight into the accuracy and stability properties of the predictor‐multicorrector algorithm for different approximations of non‐linear internal forces is gained, showing that the properties of the underlying scheme can be substantially retained. Finally, the results of representative numerical simulations relevant to Duffing oscillators and to a stiff spring pendulum discretized with finite elements illustrate the performance of the numerical scheme and confirm the analytical estimates. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
13.
Non‐linear structural identification problems have raised considerable research efforts since decades, in which the Bouc–Wen model is generally utilized to simulate non‐linear structural constitutive characteristic. Support vector regression (SVR), a promising data processing method, is studied for versatile‐typed structural identification. First, a model selection strategy is utilized to determine the unknown power parameter of the Bouc–Wen model. Meanwhile, optimum SVR parameters are selected automatically, instead of tuning manually. Consequently, the non‐linear structural equation is rewritten in linear form, and is solved by the SVR technique. A five‐floor versatile‐type structure is studied to show the effectiveness of the proposed method, in which both power parameter known and unknown cases are investigated. Copyright © 2007 John Wiley & Sons, Ltd. 相似文献
14.
A new formulation is proposed to model pounding between two adjacent structures, with natural periods T1 and T2 and damping ratios ζ1 and ζ2 under harmonic earthquake excitation, as non‐linear Hertzian impact between two single‐degree‐of‐freedom oscillators. For the case of rigid impacts, a special case of our analytical solution has been given by Davis (‘Pounding of buildings modelled by an impact oscillator’ Earthquake Engineering and Structural Dynamics, 1992; 21 :253–274) for an oscillator pounding on a stationary barrier. Our analytical predictions for rigid impacts agree qualitatively with our numerical simulations for non‐rigid impacts. When the difference in natural periods between the two oscillators increases, the impact velocity also increases drastically. The impact velocity spectrum is, however, relatively insensitive to the standoff distance. The maximum relative impact velocity of the coupled system can occur at an excitation period Tn* which is either between those of the two oscillators or less than both of them, depending on the ratios T1/T2 and ζ1/ζ2. Although the pounding force between two oscillators has been primarily modelled by the Hertz contact law, parametric studies show that the maximum relative impact velocity is not very sensitive to changes in the contact parameters. Copyright © 2001 John Wiley & Sons, Ltd. 相似文献
15.
A method for parametric system identification of classically damped linear system in frequency domain is adopted and extended for non‐classically damped linear systems subjected up to six components of earthquake ground motions. This method is able to work in multi‐input/multi‐output (MIMO) case. The response of a two‐degree‐of‐freedom model with non‐classical damping, excited by one‐component earthquake ground motion, is simulated and used to verify the proposed system identification method in the single‐input/multi‐output case. Also, the records of a 10 storey real building during the Northridge earthquake is used to verify the proposed system identification method in the MIMO case. In this case, at first, a single‐input/multi‐output assumption is considered for the system and modal parameters are identified, then other components of earthquake ground motions are added, respectively, and the modal parameters are identified again. This procedure is repeated until all four components of earthquake ground motions which are measured at the base level of the building are included in the identification process. The results of identification of real building show that consideration of non‐classical damping and inclusion of the multi‐components effect of earthquake ground motions can improve the least‐squares match between the finite Fourier transforms of recorded and calculated acceleration responses. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
16.
The non‐stationary cross‐correlation coefficients in the seismic analysis of MDOF structural systems
A method concerning the evaluation, in a very compact form, of the non‐stationary modal cross‐correlation coefficients of MDOF structural systems subjected to seismic excitations is presented. It is available both in the case when the excitation is considered as a white‐noise process and when it is considered as a filtered process. The evaluation of these coefficients is required when a transient seismic analysis is performed by the use of the modal response spectrum approach. This is necessary when the strong‐motion phase of the earthquake is significantly short with respect to the fundamental period of the structure. Copyright © 2003 John Wiley & Sons, Ltd. 相似文献
17.
To limit the response of structures during external disturbances such as strong winds or large seismic events, structural control systems can be used. In the structural engineering field, attention has been shifted from active control to semi‐active control systems. Unlike active control system devices, semi‐active devices are compact, have efficient power consumption characteristics and are less expensive. As a result, an environment of a large number of actuators and sensors will result, rendering a complex large‐scale dynamic system. Such a system is best controlled by a decentralized approach such as market‐based control (MBC). In MBC, the system is modelled as a market place of buyers and sellers that leads to an efficient allocation of control power. The resulting MBC solution is shown to be locally Pareto optimal. This novel control approach is applied to three linear structural systems ranging from a one‐storey structure to a 20‐storey structure, all controlled by semi‐active hydraulic dampers. It is shown that MBC is competitive in the reduction of structural responses during large seismic loadings as compared to the centralized control approach of the linear quadratic regulation controller. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
18.
19.
Influence of time‐varying frequency content in earthquake ground motions on seismic response of linear elastic systems 下载免费PDF全文
Earthquake ground motion records are nonstationary in both amplitude and frequency content. However, the latter nonstationarity is typically neglected mainly for the sake of mathematical simplicity. To study the stochastic effects of the time‐varying frequency content of earthquake ground motions on the seismic response of structural systems, a pair of closely related stochastic ground motion models is adopted here. The first model (referred to as ground motion model I) corresponds to a fully nonstationary stochastic earthquake ground motion model previously developed by the authors. The second model (referred to as ground motion model II) is nonstationary in amplitude only and is derived from the first model. Ground motion models I and II have the same mean‐square function and global frequency content but different features of time variation in the frequency content, in that no time variation of the frequency content exists in ground motion model II. New explicit closed‐form solutions are derived for the response of linear elastic SDOF and MDOF systems subjected to stochastic ground motion model II. New analytical solutions for the evolutionary cross‐correlation and cross‐PSD functions between the ground motion input and the structural response are also derived for linear systems subjected to ground motion model I. Comparative analytical results are presented to quantify the effects of the time‐varying frequency content of earthquake ground motions on the structural response of linear elastic systems. It is found that the time‐varying frequency content in the seismic input can have significant effects on the stochastic properties of system response. Copyright © 2016 John Wiley & Sons, Ltd. 相似文献
20.
The N2 method for simplified non‐linear seismic analysis has been extended in order to make it applicable to infilled reinforced concrete frames. Compared to the simple basic variant of the N2 method, two important differences apply. A multi‐linear idealization of the pushover curve, which takes into account the strength degradation which occurs after the infill fails, has to be made, and specific reduction factors, developed in a companion paper, have to be used for the determination of inelastic spectra. It is shown that the N2 method can also be used for the determination of approximate summarized IDA curves. The proposed method was applied to two test buildings. The results were compared with the results obtained by non‐linear dynamic analyses for three sets of ground motions, and a reasonable accuracy was demonstrated. A similar extension of the N2 method can be made to any structural system, provided that an appropriate specific R–µ–T relation is available. Copyright © 2004 John Wiley & Sons, Ltd. 相似文献