首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new direct performance‐based design method utilizing design tools called performance‐spectra (P‐Spectra) for low‐rise to medium‐rise frame structures incorporating supplemental damping devices is presented. P‐Spectra are graphic tools that relate the responses of nonlinear SDOF systems with supplemental dampers to various damping parameters and dynamic system properties that structural designers can control. These tools integrate multiple response quantities that are important to the performance of a structure into a single compact graphical format to facilitate direct comparison of different potential solutions that satisfy a set of predetermined performance objectives under various levels of seismic hazard. An SDOF to MDOF transformation procedure that defines the required supplemental damping properties for the MDOF structure to achieve the response defined by the target SDOF system is also presented for hysteretic, linear viscous and viscoelastic damping devices. Using nonlinear time‐history analyses of idealized shear structures, the accuracy of the transformation procedure is verified. A seismic performance upgrade design example is presented to demonstrate the usefulness of the proposed method for achieving design performance goals using supplemental damping devices. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
This paper evaluates the hysteretic behavior of an innovative compressed elastomer structural damper and its applicability to seismic‐resistant design of steel moment‐resisting frames (MRFs). The damper is constructed by precompressing a high‐damping elastomeric material into steel tubes. This innovative construction results in viscous‐like damping under small strains and friction‐like damping under large strains. A rate‐dependent hysteretic model for the compressed elastomer damper, formed from a parallel combination of a modified Bouc–Wen model and a non‐linear dashpot is presented. The model is calibrated using test data obtained under sinusoidal loading at different amplitudes and frequencies. This model is incorporated in the OpenSees [17] computer program for use in seismic response analyses of steel MRF buildings with compressed elastomer dampers. A simplified design procedure was used to design seven different systems of steel MRFs combined with compressed elastomer dampers in which the properties of the MRFs and dampers were varied. The combined systems are designed to achieve performance, which is similar to or better than the performance of conventional steel MRFs designed according to current seismic codes. Based on the results of nonlinear seismic response analyses, under both the design basis earthquake and the maximum considered earthquake, target properties for a new generation of compressed elastomer dampers are defined. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
Supplemental viscous damping devices are generally envisioned to be connected in parallel to the inelastic parent structure or hysteretic damping devices. This gives rise to higher base shear, and often greater ductility demand of the hysteretic system. The series connection of the viscous and hysteretic system (the inelastic structure or a damper) is an alternative approach. In this paper, comparisons between the series and parallel connections of the hysteretic system and viscous dampers are done through response spectra analyses of single degree of freedom structures. Ductility demand of the hysteretic system and the total base shear are chosen as the response quantities. For the series model, a semi‐implicit solution scheme for classical Maxwell model is modified to include the inelasticity of the time‐independent hysteretic spring. It is observed that the series connection of the 2 dampers gives lower base shear than does the parallel connection. For long‐period and low‐damping structures, the ductility demand of the hysteretic system in series connection is higher than that in parallel connection. Increasing the viscous damping in series connection reduces the ductility demand substantially, lower than that obtained in parallel connection. Practical methods for implementing the series and parallel connections, in line with roof isolation, are also suggested.  相似文献   

4.
Equivalent viscous damping for steel concentrically braced frame structures   总被引:1,自引:1,他引:0  
The direct displacement based seismic design procedure utilises equivalent viscous damping expressions to represent the effect of energy dissipation of a structural system. Various expressions for the equivalent viscous damping of different structural systems are available in the literature, but the structural systems examined in the past have not included concentrically braced frame structures. Thus, this study describes the development of an equivalent viscous damping equation for concentrically braced frame structures based on the hysteretic response of 15 different single storey models. Initially, equivalent viscous damping is calculated based on the area based approach and then corrected for the earthquake excitation. An iterative procedure is adopted to calibrate the equivalent viscous damping expression to the results of inelastic time history analyses using a number of spectrum-compatible real accelerograms. From the results of this research, a new damping expression is developed as a function of the ductility and the non dimensional slenderness ratio.  相似文献   

5.
A new passive seismic response control device has been developed, fabricated, and tested by the authors and shown to be capable of producing negative stiffness via a purely mechanical mechanism, thus representing a new generation of seismic protection devices. Although the concept of negative stiffness may appear to be a reversal on the desired relationship between the force and displacement in structures (the desired relationship being that the product of restoring force and displacement is nonnegative), when implemented in parallel with a structure having positive stiffness, the combined system appears to have substantially reduced stiffness while remaining stable. Thus, there is an ‘apparent weakening and softening’ of the structure that results in reduced forces and increased displacements (where the weakening and softening is of a non‐damaging nature in that it occurs in a seismic protection device rather than within the structural framing system). Any excessive displacement response can then be limited by incorporating a damping device in parallel with the negative stiffness device. The combination of negative stiffness and passive damping provides a large degree of control over the expected performance of the structure. In this paper, a numerical study is presented on the performance of a seismically isolated highway bridge model that is subjected to various strong earthquake ground motions. The Negative Stiffness Devices (NSDs) are described along with their hysteretic behavior as obtained from a series of cyclic tests wherein the tests were conducted using a modified design of the NSDs (modified for testing within the bridge model). Using the results from the cyclic tests, numerical simulations of the seismic response of the isolated bridge model were conducted for various configurations (with/without negative stiffness devices and/or viscous dampers). The results demonstrate that the addition of negative stiffness devices reduces the base shear substantially, while the deck displacement is limited to acceptable values. This assessment was conducted as part of a NEES (Network for Earthquake Engineering Simulation) project which included shaking table tests of a quarter‐scale highway bridge model. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
By advancing the technologies regarding seismic control of structures and development of earthquake resistance systems in the past decades application of different types of earthquake energy dissipation system has incredibly increased. Viscous damper device as a famous and the simplest earthquake energy dissipation system is implemented in many new structures and numerous number of researches have been done on the performance of viscous dampers in structures subjected to earthquake. The experience of recent severe earthquakes indicates that sometimes the earthquake energy dissipation devices are damaged during earthquakes and there is no function for structural control system. So, damage of earthquake energy dissipation systems such as viscous damper device must be considered during design of earthquake resistance structures.This paper demonstrates the development of three-dimensional elasto-plastic viscous damper element consisting of elastic damper in the middle part and two plastic hinges at both ends of the element which are compatible with the constitutive model to reinforce concrete structures and are capable to detect failure and damage in viscous damper device connections during earthquake excitation. The finite element model consists of reinforced concrete frame element and viscous damper element is developed and special finite element algorithm using Newmark׳s direct step-by-step integration is developed for inelastic dynamic analysis of structure with supplementary elasto-plastic viscous damper element. So based on all the developed components an especial finite computer program has been codified for “Nonlinear Analysis of Reinforced Concrete Buildings with Earthquake Energy Dissipation System”. The evaluation of seismic response of structure and damage detection in structural members and damper device was carried out by 3D modeling, of 3 story reinforced concrete frame building under earthquake multi-support excitation.  相似文献   

7.
The purpose of this research is to use data from experiments to formulate a mathematical model that will predict the non-linear response of a single-storey steel frame to an earthquake input. The process used in this formulation is system identification. The form of the model is a second-order non-linear differential equation with linear viscous damping and Ramberg—Osgood type hysteresis. The damping coefficient and the three parameters in the hysteretic model are to be established. An integral weighted mean squared error function is used to evaluate the [goodness of fit] between the model's response and the structure's response when both are subjected to the same excitation. The function includes errors in displacement and acceleration and is integrated from zero to a time T, which may be the full duration of the recorded response or only a portion of it. The parameters are adjusted using a modified Gauss-Newton method until the error function is minimized. The computer program incorporating these steps in the system identification process is verified with simulated data. Results given in the paper show that in every case the program converges in few iterations to the assigned set of parameters.  相似文献   

8.
惯容器是一种新型的振动控制装置,该装置可以将螺杆的轴向运动转换为黏滞材料和旋转质量的高速旋转运动,使阻尼器的阻尼效应和质量效应得到放大。基于惯容器原理以及电涡流原理,提出一种新型的拉索式旋转电涡流阻尼器,为结构被动控制提供了新的设计思路。为研究这种新型惯容系统的减振机理,对安装拉索式旋转电涡流阻尼器单层框架的力学模型进行了探讨。推导出了配置惯容系统单质点体系的动力表达式,并基于此表达式探讨在频域内该惯容系统关键参数对单质点体系位移、速度和加速度响应的影响。结果表明:这种拉索式旋转电涡流阻尼器可以起到放大质量的效果,惯容系统可以有效地减少单质点体系的位移、速度和加速度响应幅值。  相似文献   

9.
Nonlinear viscous dampers are supplemental devices widely used for enhancing the performance of structural systems exposed to seismic hazard. A rigorous evaluation of the effect of these damping devices on the seismic performance of a structural system should be based on a probabilistic approach and take into account the evolutionary characteristics of the earthquake input and of the corresponding system response. In this paper, an approximate analytical technique is proposed for studying the nonstationary stochastic response characteristics of hysteretic single degree of freedom systems equipped with viscous dampers subjected to a fully nonstationary random process representing the seismic input. In this regard, a stochastic averaging/linearization technique is utilized to cast the original nonlinear stochastic differential equation of motion into a simple first‐order nonlinear ordinary differential equation for the nonstationary system response variance. In comparison with standard linearization schemes, the herein proposed technique has the significant advantage that it allows to handle realistic seismic excitations with time‐varying frequency content. Further, it allows deriving a formula for determining the nonlinear system response evolutionary power spectrum. By this way, ‘moving resonance’ effects, related to both the evolutionary seismic excitation and the nonlinear system behavior, can be observed and quantified. Several applications involving various system and input properties are included. Furthermore, various response parameters of interest for the seismic performance assessment are considered as well. Comparisons with pertinent Monte Carlo simulations demonstrate the reliability of the proposed technique. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
Investigated are earthquake responses of one‐way symmetric‐plan, one‐storey systems with non‐linear fluid viscous dampers (FVDs) attached in series to a linear brace (i.e. Chevron or inverted V‐shape braces).Thus, the non‐linear damper is viscous when the brace is considered rigid or viscoelastic (VE) when the brace is flexible. The energy dissipation capacity of a non‐linear FVD is characterized by an amplitude‐dependent damping ratio for an energy‐equivalent linear FVD, which is determined assuming the damper undergoes harmonic motion. Although this formulation is shown to be advantageous for single‐degree‐of‐freedom (SDF) systems, it is difficult to extend its application to multi‐degree‐of‐freedom (MDF) systems for two reasons: (1) the assumption that dampers undergo harmonic motion in parameterizing the non‐linear damper is not valid for its earthquake‐induced motion of an MDF system; and (2) ensuring simultaneous convergence of all unknown amplitudes of dampers is difficult in an iterative solution of the non‐linear system. To date, these limitations have precluded the parametric study of the dynamics of MDF systems with non‐linear viscous or VE dampers. However, they are overcome in this investigation using concepts of modal analysis because the system is weakly non‐linear due to supplemental damping. It is found that structural response is only weakly affected by damper non‐linearity and is increased by a small amount due to bracing flexibility. Thus, the effectiveness of supplemental damping in reducing structural responses and its dependence on the planwise distribution of non‐linear VE dampers were found to be similar to that of linear FVDs documented elsewhere. As expected, non‐linear viscous and VE dampers achieve essentially the same reduction in response but with much smaller damper force compared to linear dampers. Finally, the findings in this investigation indicate that the earthquake response of the asymmetric systems with non‐linear viscous or VE dampers can be estimated with sufficient accuracy for design applications by analysing the same asymmetric systems with all non‐linear dampers replaced by energy‐equivalent linear viscous dampers. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
The causal and physically realizable Biot hysteretic model proves to be the simplest linear model able to describe the nearly rate‐independent behaviour of engineering materials. In this paper, the performance of the Biot hysteretic model is analysed and compared with those of the ideal and causal hysteretic models. The Laguerre polynomial approximation (LPA) method, recently proposed for the time‐domain analysis of linear viscoelastic systems, is then summarized and applied to the prediction of the dynamic response of linear hysteretic systems to deterministic and random excitations. The parameters of the LPA model generally need to be computed through numerical integrals; however, when this model is used to approximate the Biot hysteretic model, closed‐form expressions can be found. Effective step‐by‐step procedures are also provided in the paper, which prove to be accurate also for high levels of damping. Finally, the method is applied to the dynamic analysis of a highway embankment excited by deterministic and random ground motions. The results show that in some cases the inaccuracy associated with the use of an equivalent viscous damping model is too large. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

12.
This paper investigates the effects of supplemental viscous damping on the seismic response of one‐storey, asymmetric‐plan systems responding in the inelastic range of behaviour. It was found that addition of the supplemental damping reduces not only deformation demand but also ductility and hysteretic energy dissipation demands on lateral load resisting elements during earthquake loading. However, the level of reduction strongly depends on the plan‐wise distribution of supplemental damping. Nearly optimal reduction in demands on the outermost flexible‐side element, an element generally considered to be the most critical element, was realized when damping was distributed unevenly in the system plan such that the damping eccentricity was equal in magnitude but opposite in algebraic sign to the structural eccentricity of the system. These results are similar to those noted previously for linear elastic systems, indicating that supplemental damping is also effective for systems expected to respond in the inelastic range. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

13.
Damping formulation for nonlinear 1D site response analyses   总被引:2,自引:0,他引:2  
Measurements and observations of ground shaking during large earthquakes have demonstrated the predominant role of site effects in the response of infrastructure during a seismic event. Despite significant efforts to model the hysteretic response and nonlinearity of soils due to medium and large ground motions, the most widely accepted nonlinear site response methods are not able to represent simultaneously the changes of stiffness and energy dissipation (damping) observed in both laboratory tests and during earthquake events. This paper presents two new soil damping formulations implemented in nonlinear one-dimensional site response analysis for small and large strains. The first formulation introduces an approach to construct a frequency-independent viscous damping matrix which reduces the over-damping at high frequencies, and therefore, the filtering at those frequencies. The second formulation introduces a reduction factor that modifies the extended Masing loading/unloading strain–stress relationship to match measured modulus reduction and damping curves simultaneously over a wide range of shear strains. A set of examples are introduced to illustrate the effect of using the two proposed formulations, separately and simultaneously, in nonlinear site response analyses.  相似文献   

14.
Optimum isolation damping for minimum acceleration response of base-isolated structures subjected to stationary random excitation is investigated. Three linear models are considered to account for the energy dissipation mechanism of the isolation system: a Kelvin element, a linear hysteretic element and a standard solid linear element, commonly used viscoelastic models for isolation systems comprising natural rubber bearings and viscous dampers. The criterion selected for optimality is the minimization of the mean-square floor acceleration response. The effects of the frequency content of the excitation and superstructure properties on the optimum damping and on the mean-square acceleration response are addressed. The study basically shows that the attainable reduction in the floor acceleration largely depends on the energy dissipation mechanism assumed for the isolation system as well as on the frequency content of the ground acceleration process. Special care should be taken in accurately modelling the mechanical behaviour of the energy dissipation devices.  相似文献   

15.
A new method of stiffness‐damping simultaneous identification of building structures is proposed using limited earthquake records. It is shown that when horizontal accelerations are recorded at the floors just above and below a specific storey in a shear building model, the storey stiffness and the damping ratio can be identified uniquely. The viscous damping coefficient and the linear hysteretic damping ratio can also be identified simultaneously in a numerical model structure. The accuracy of the present identification method is investigated through the actual limited earthquake records in a base‐isolated building. It is further shown that an advanced identification technique for mechanical properties of a Maxwell‐type model can be developed by combining the present method with a perturbation technique. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

16.
The unloading parameters of hysteretic models for RC members are given in terms of their shear-span-to-depth ratio and the viscous damping used to model other energy dissipation sources. They reflect the energy dissipation in full post-yield load cycles in 534 tests of rectangular or circular members. Pre-yield hysteretic energy dissipation—ignored if the model is elastic till yielding—amounts in the tests to a mean viscous damping around 8.5% and can be considered in nonlinear response-history analysis through a new model which combines constant elastic stiffness in virgin loading with hysteretic energy dissipation both before and after yielding. Models with linear behavior till yielding and hysteretic energy dissipation only after it come closer to the results of the new model if viscous damping is 5%.  相似文献   

17.
Viscous and other damping devices are often used as elements of seismic isolation systems. Despite the widespread application of nonlinear viscous systems particularly in Japan (with fewer applications in the USA and Taiwan), the application of viscous damping devices in isolation systems in the USA progressed intentionally toward the use of supplementary linear viscous devices due to the advantages offered by these devices. This paper presents experimental results on the behavior of seismically isolated structures with low damping elastomeric (LDE) and single friction pendulum (SFP) bearings with and without linear and nonlinear viscous dampers. The isolation systems are tested within a six‐story structure configured as moment frame and then again as braced frame. Emphasis is placed both on the acquisition of data related to the structural system (drifts, story shear forces, and isolator displacements) and on non‐structural systems (floor accelerations, floor spectral accelerations, and floor velocities). Moreover, the accuracy of analytical prediction of response is investigated based on the results of a total of 227 experiments, using 14 historic ground motions of far‐fault and near‐fault characteristics, on flexible moment frame and stiff braced frame structures isolated with LDE or SFP bearings and linear or nonlinear viscous dampers. It is concluded that when damping is needed to reduce displacement demands in the isolation system, linear viscous damping results in the least detrimental effect on the isolated structure. Moreover, the study concludes that the analytical prediction of peak floor accelerations and floor response spectra may contain errors that need to be considered when designing secondary systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
This paper proposes a method for the seismic retrofitting of existing frames by adding hysteretic energy dissipating devices (EDDs). The procedure is based on the energy balance of the structure, and it is used to determine the lateral strength, the lateral stiffness and the energy dissipation capacity of the EDDs needed in each story to achieve prescribed target performance levels for a given earthquake hazard. The performance levels are governed by the maximum lateral displacement. The earthquake hazard is characterized in terms of input energy and several seismological parameters, and further takes into account the proximity of the earthquake to the source. The proposed method deals with the effect of the EDDs explicitly in terms of hysteretic energy, bypassing equivalent viscous damping approximations, and directly quantifies the cumulative damage induced in the EDDs. The validity of the method is assessed numerically through nonlinear dynamic response analyses with near-fault and far-field ground motions, as well as experimentally through dynamic shaking table tests.  相似文献   

19.
The insertion of fluid viscous dampers in building structures is an innovative technology that can improve significantly the seismic response. These devices could be very useful also in the retrofit of existing buildings. The effect of this typology of damping system is usually identified with an equivalent supplemental damping ratio, which depends on the maximum displacement of the structure, so that iterative procedures are required. In this paper, a simplified direct assessment method for nonlinear structures equipped with nonlinear fluid viscous dampers is proposed. The method proposed in this study is composed by two steps. The first one yields the direct estimate of the supplemental damping ratio provided by nonlinear viscous dampers in presence of a linear elastic structural response. The second step extends the procedure to structures with nonlinear behavior. Both graphical and analytical approaches have been developed. The proposed method has then been verified through several applications and comparisons with nonlinear dynamic analyses. Moreover, an investigation has been performed with regard to the influence of the relations that define the damping reduction factor and the hysteretic damping. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
In order to account for the non‐linear behavior of structures via non‐linear static procedure, the capacity spectrum method has been adopted by ATC‐40 for evaluation and retrofit of reinforced concrete buildings. For elastic‐perfectly‐plastic SDOF systems, the accuracy of the capacity spectrum method depends only on the acceleration response spectrum chosen to form the demand spectrum and the adopted model for calculating the equivalent viscous damping ratios. According to this method, the pseudo‐acceleration response spectrum (PSa) is used to create the demand diagram. It is found that the ATC‐40 procedure, using its Type A hysteretic model, may be inaccurate especially for systems with damping ratios greater than 10% and periods longer than 0.15sec. In order to improve the accuracy of the capacity spectrum method, this study proposes to use the real absolute acceleration response spectrum (S0.a) instead of the PSa to establish the demand diagram. The step‐by‐step procedure of the improved method and examples are implemented in this paper to illustrate the calculations of earthquake‐induced deformations. In addition, three selected models of equivalent viscous damping are also compared in this paper to assess the accuracy of the model used in the ATC‐40 procedure. Results show that the WJE damping model may be used by the capacity spectrum method to reasonably predict the inelastic displacements when the ductility demand (μ) of the structures is less than 4, whereas the damping model proposed by Kowalsky can be implemented when μ>4.0. Alternatively, the damping model proposed by Kowalsky may be used to calculate the equivalent viscous damping for the entire range of ductility. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号