Dynamic characteristics and seismic behavior of prefabricated steel stairs in a full‐scale five‐story building shake table test program 下载免费PDF全文
Xiang Wang Rodrigo Astroza Tara C. Hutchinson Joel P. Conte José I. Restrepo 《地震工程与结构动力学》2015,44(14):2507-2527
This paper investigates the dynamic characteristics and seismic behavior of prefabricated steel stairs in a full‐scale five‐story building shake table test program. The test building was subjected to a suite of earthquake input motions and low‐amplitude white noise base excitations first, while the building was isolated at its base, and subsequently while it was fixed to the shake table platen. This paper presents the modal characteristics of the stairs identified using the data recorded from white noise base excitation tests as well as the physical and measured responses of the stairs from the earthquake tests. The observed damage to the stairs is categorized into three distinct damage states and is correlated with the interstory drift demands of the building. These shake table tests highlight the seismic vulnerability of modern designed stair systems and in particular identifies as a key research need the importance of improving the deformability of flight‐to‐building connections. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
2.
Xiang Wang Tara C. Hutchinson Rodrigo Astroza Joel P. Conte José I. Restrepo Matthew S. Hoehler Waldir Ribeiro 《地震工程与结构动力学》2017,46(3):391-407
This paper investigates the seismic performance of a functional traction elevator as part of a full‐scale five‐story building shake table test program. The test building was subjected to a suite of earthquake input motions of increasing intensity, first while the building was isolated at its base and subsequently while it was fixed to the shake table platen. In addition, low‐amplitude white noise base excitation tests were conducted while the elevator system was placed in three different configurations, namely, by varying the vertical location of its cabin and counterweight, to study the acceleration amplifications of the elevator components due to dynamic excitations. During the earthquake tests, detailed observation of the physical damage and operability of the elevator as well as its measured response are reported. Although the cabin and counterweight sustained large accelerations because of impact during these tests, the use of well‐restrained guide shoes demonstrated its effectiveness in preventing the cabin and counterweight from derailment during high‐intensity earthquake shaking. However, differential displacements induced by the building imposed undesirable distortion of the elevator components and their surrounding support structure, which caused damage and inoperability of the elevator doors. It is recommended that these aspects be explicitly considered in elevator seismic design. Copyright © 2016 John Wiley & Sons, Ltd. 相似文献
3.
Influence of the construction process and nonstructural components on the modal properties of a five‐story building 下载免费PDF全文
Rodrigo Astroza Hamed Ebrahimian Joel P. Conte José I. Restrepo Tara C. Hutchinson 《地震工程与结构动力学》2016,45(7):1063-1084
A full‐scale five‐story reinforced concrete building was built and tested on the NEES‐UCSD shake table during the period from May 2011 to May 2012. The purpose of this test program was to study the response of the structure and nonstructural components and systems (NCSs) and their dynamic interaction during seismic base excitation of different intensities. The building specimen was tested first under a base‐isolated condition and then under a fixed‐based condition. As the building was being erected, an accelerometer array was deployed on the specimen to study the evolution of its modal parameters during the construction process and placement of major NCSs. A sequence of dynamic tests, including daily ambient vibration, shock (free vibration) and forced vibration tests (low‐amplitude white noise and seismic base excitations), were performed on the building at different stages of construction. Different state‐of‐the‐art system identification methods, including three output‐only and two input‐output methods, were used to estimate the modal properties of the building. The obtained results allow to investigate in detail the effects of the construction process and NCSs on the dynamic parameters of this building system and to compare the modal properties obtained from different methods, as well as the performance of these methods. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
4.
5.
Christopher Trautner Tara Hutchinson Philipp Grosser Roberto Piccinin John Silva 《地震工程与结构动力学》2019,48(2):173-187
Previous research has demonstrated that uplifting-column or rocking building systems may exhibit improved seismic performance, including reductions in total base shear and decreased residual drift, when compared with systems rigidly connected to the foundation. These beneficial effects may be due to lengthened periods, activation of rocking modes, and energy dissipation of base fuse elements. In the current work, several configurations of a miniature steel building with different combinations of base connection and traditional superstructure fuse strength and stiffness were subjected to identical earthquake motions to evaluate differences in demands and performance. The uplifting base connections incorporate highly ductile concrete anchors with long stretch lengths, allowing robust connection performance and easy replacement of damaged connection elements following the seismic event, an advantage over previously tested systems. Testing and dynamic numerical analysis indicates that ductile anchor uplifting systems may reduce total base shear by over 20%, as well as reducing residual structural drift by more than 80%. 相似文献
6.
Jason McCormick Takuya Nagae Masahiro Ikenaga Peng‐Cheng Zhang Mika Katsuo Masayoshi Nakashima 《地震工程与结构动力学》2009,38(12):1401-1419
The friction developed between a steel base plate and a mortar base contributes shear resistance to the building system during a seismic event. In order to investigate the possible sliding behavior between the base plate and the mortar, a shake table study is undertaken using a large rigid mass supported by steel contact elements which rest on mortar surfaces connected to the shake table. Horizontal input accelerations are considered at various magnitudes and frequencies. The results provide a constant friction coefficient during sliding with an average value of approximately 0.78. A theoretical formulation of the friction behavior is also undertaken. The theoretical equations show that the sliding behavior is dependent on the ratio of the friction force to the input force. The addition of vertical accelerations to the system further complicates the sliding behavior as a result of the varying normal force. This results in a variable friction resistance which is a function of the amplitude, phase, and frequency of the horizontal and vertical input motions. In general, this study showed a consistent and reliable sliding behavior between steel and mortar. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
7.
This paper describes the identification of finite dimensional, linear, time‐invariant models of a 4‐story building in the state space representation using multiple data sets of earthquake response. The building, instrumented with 31 accelerometers, is located on the University of California, Irvine campus. Multiple data sets, recorded during the 2005 Yucaipa, 2005 San Clemente, 2008 Chino Hills and 2009 Inglewood earthquakes, are used for identification and validation. Considering the response of the building as the output and the ground motion as the input, the state space models that represent the underlying dynamics of the building in the discrete‐time domain corresponding to each data set are identified. The time‐domain Eigensystem Realization Algorithm with the Observer/Kalman filter identification procedure are adopted in this paper, and the modal parameters of the identified models are consistently determined by constructing stabilization diagrams. The four state space models identified demonstrate that the response of the building is amplitude dependent with the response frequency and damping, being dependent on the magnitude of ground excitation. The practical application of this finding is that the consistency of this building response to future earthquakes can be quickly assessed, within the range of ground excitations considered (0.005g–0.074g), for consistency with prior response—this assessment of consistent response is discussed and demonstrated with reference to the four earthquake events considered in this study. Inclusion of data sets relating to future earthquakes will enable the findings to be extended to a wider range of ground excitation magnitudes. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
8.
A method for parametric system identification of classically damped linear system in frequency domain is adopted and extended for non‐classically damped linear systems subjected up to six components of earthquake ground motions. This method is able to work in multi‐input/multi‐output (MIMO) case. The response of a two‐degree‐of‐freedom model with non‐classical damping, excited by one‐component earthquake ground motion, is simulated and used to verify the proposed system identification method in the single‐input/multi‐output case. Also, the records of a 10 storey real building during the Northridge earthquake is used to verify the proposed system identification method in the MIMO case. In this case, at first, a single‐input/multi‐output assumption is considered for the system and modal parameters are identified, then other components of earthquake ground motions are added, respectively, and the modal parameters are identified again. This procedure is repeated until all four components of earthquake ground motions which are measured at the base level of the building are included in the identification process. The results of identification of real building show that consideration of non‐classical damping and inclusion of the multi‐components effect of earthquake ground motions can improve the least‐squares match between the finite Fourier transforms of recorded and calculated acceleration responses. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
9.
Verification of system identification utilizing shaking table tests of a full‐scale 4‐story steel building 下载免费PDF全文
Yoshiki Ikeda 《地震工程与结构动力学》2016,45(4):543-562
This paper verifies the feasibility of the proposed system identification methods by utilizing shaking table tests of a full‐scale four‐story steel building at E‐Defense in Japan. The natural frequencies, damping ratios and modal shapes are evaluated by single‐input‐four‐output ARX models. These modal parameters are prepared to identify the mass, damping and stiffness matrices when the objective structure is modelled as a four degrees of freedom (4DOF) linear shear building in each horizontal direction. The nonlinearity in stiffness is expressed as a Bouc–Wen hysteretic system when it is modelled as a 4DOF nonlinear shear building. The identified hysteretic curves of all stories are compared to the corresponding experimental results. The simple damage detection is implemented using single‐input‐single‐output ARX models, which require only two measurements in each horizontal direction. The modal parameters are equivalent‐linearly evaluated by the recursive Least Squares Method with a forgetting factor. When the structure is damaged, its natural frequencies decrease, and the corresponding damping ratios increase. The fluctuation of the identified modal properties is the indirect information for damage detection of the structure. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
10.
钢结构与混凝土结构阻尼比不同,混凝土房屋与其顶上钢塔组成了非比例阻尼结构系统。本文用非经典振型分解法求解该类结构系统的线弹性地震响应,发现只用前几阶振型响应迭加的结果即可逼近直接积分法的精确度。 相似文献
11.
Damage assessment through structural identification of a three‐story large‐scale precast concrete structure 下载免费PDF全文
This paper investigates the damage assessment of a three‐story half‐scale precast concrete building resembling a parking garage through structural identification. The structure was tested under earthquake‐type loading on the NEES large high‐performance outdoor shake table at the University of California San Diego in 2008. The tests provide a unique opportunity to capture the dynamic performance of precast concrete structures built under realistic boundary conditions. The effective modal parameters of the structure at different damage states have been identified from white‐noise and scaled earthquake test data with the assumption that the structure responded in a quasi‐linear manner. Modal identification has been performed using the deterministic‐stochastic subspace identification method based on the measured input–output data. The changes in the identified modal parameters are correlated to the observed damage. In general, the natural frequencies decrease, and the damping ratios increase as the structure is exposed to larger base excitations, indicating loss of stiffness, development/propagation of cracks, and failure in joint connections. The analysis of the modal rotations and curvatures allowed the localization of shear and flexural damages respectively and the checking of the effectiveness of repair actions. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
12.
Post‐tensioned (PT) self‐centering moment frames were developed as an alternative to welded moment‐resisting frames (MRFs). Lateral deformation of a PT frame opens gaps between beams and columns. The use of a composite slab in welded MRFs limits the opening of gaps at the beam‐to‐column interfaces but cannot be adopted in PT self‐centering frames. In this study, a sliding slab is used to minimize restraints to the expansion of the PT frame. A composite slab is rigidly connected to the beams in a single bay of the PT frame. A sliding device is installed between the floor beams and the beams in other bays, wherever the slab is allowed to slide. Many shaking table tests were conducted on a reduced‐scale, two‐by‐two bay one‐story specimen, which comprised one PT frame and two gravitational frames (GFs). The PT frame and GFs were self‐centering throughout the tests, responding in phase with only minor differences in peak drifts that were caused by the expansion of the PT frame. When the specimen was excited by the 1999 Chi‐Chi earthquake with a peak ground acceleration of 1.87g, the maximum interstory drift was 7.2% and the maximum lateral force was 270 kN, equal to 2.2 times the yield force of the specimen. Buckling of the beam bottom flange was observed near the column face, and the initial post‐tensioning force in the columns and beams decreased by 50 and 22%, respectively. However, the specimen remained self‐centering and its residual drift was 0.01%. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
13.
This work presents a novel procedure for identifying the dynamic characteristics of a building and diagnosing whether the building has been damaged by earthquakes, using a back‐propagation neural network approach. The dynamic characteristics are directly evaluated from the weighting matrices of the neural network trained by observed acceleration responses and input base excitations. Whether the building is damaged under a large earthquake is assessed by comparing the modal parameters and responses for this large earthquake with those for a small earthquake that has not caused this building any damage. The feasibility of the approach is demonstrated through processing the dynamic responses of a five‐storey steel frame, subjected to different strengths of the Kobe earthquake, in shaking table tests. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
14.
工作状态下桥梁结构的模态参数识别是桥梁损伤识别的重要环节,考虑桥梁检测的实用性,桥梁检测一般应建立在环境激励的基础上,已有的环境激励下模态参数识别的方法对模态频率的识别的精度较高,而对位移模态的识别则误差较大。提出了一种利用移动质量块在不同位置时对桥梁的模态频率进行多次测量,用各次测得的频率值确定位移模态的新方法,使得位移模态识别的精度接近频率识别的精度,建立了该方法的初步模型,推导了频率与位移模态关系的理论公式,并通过数值模拟对该方法的有效性进行了说明。 相似文献
15.
Accurate prediction of the dynamic responses of a high-rise building subjected to dynamic loads such as earthquake and wind excitations requires the information of its structural dynamic properties such as modal parameters including natural frequencies and damping ratios. This paper presents the identification results of the modal parameters based on field vibration tests on a 600-m high skyscraper. A set of tests, including ambient vibration test (AVT) and free vibration test (FVT), were conducted on the skyscraper to identify its modal parameters. Firstly, this paper presents and discusses the modal parameters of the skyscraper assessed by several identification methods applied to the AVT measurements. These methods include the wavelet transform (WT) method, the stochastic subspace identification (SSI) method, and the random decrement technique (RDT). Secondly, an active mass damper (AMD) system with total mass 1000 tons equipped into the skyscraper was used to excite the building for estimation of the modal parameters by FVT. Thirdly, this paper presents observations on the structural dynamic behavior of the skyscraper with the operation of the AMD system during a typhoon event. The field measurement results show that the AMD system functioned efficiently for suppression of the wind-induced vibrations of the skyscraper during the typhoon. This paper aims to further understand the structural dynamic properties of super-tall buildings and provide useful information for structural design and vibration control of future skyscrapers. 相似文献
16.
Amplitude dependence of equivalent modal parameters in monitored buildings during earthquake swarms 下载免费PDF全文
Rosario Ceravolo Emiliano Matta Antonino Quattrone Luca Zanotti Fragonara 《地震工程与结构动力学》2017,46(14):2399-2417
This paper investigates the dynamic response of three sample buildings belonging to the Seismic Observatory for Structures, the Italian network for the permanent seismic monitoring of strategic structures, managed by the Italian Department of Civil Protection. The case studies cover different building types that could loosely represent the Italian building stock, with a special emphasis on cultural heritage and masonry structures. Observed under a low‐intensity seismic swarm comprising about 30 aftershocks after a main event, the three buildings are analysed through an input–output, model‐driven linear dynamic identification procedure, depicting the relation between the shaking level at the site and the variation of the equivalent structural modal parameters, while keeping into account the effects of soil–structure interaction. Finite element models will be used to investigate one of the case studies and to compare the law of variation of the structural modal parameters with respect to simplified models proposed by technical standards. Copyright © 2017 John Wiley & Sons, Ltd. 相似文献
17.
A series of large‐scale dynamic tests was conducted on a passively controlled five‐story steel building on the E‐Defense shaking table facility in Japan to accumulate knowledge of realistic seismic behavior of passively controlled structures. The specimen was tested by repeatedly inserting and replacing each of four damper types, that is, the buckling restrained braces, viscous dampers, oil dampers, and viscoelastic dampers. Finally, the bare steel moment frame was tested after removing all dampers. A variety of excitations was applied to the specimen, including white noise, various levels of seismic motion, and shaker excitation. System identification was implemented to extract dynamic properties of the specimen from the recorded floor acceleration data. Damping characteristics of the specimen were identified. In addition, simplified estimations of the supplemental damping ratios provided by added dampers were presented to provide insight into understanding the damping characteristics of the specimen. It is shown that damping ratios for the specimen equipped with velocity‐dependent dampers decreased obviously with the increasing order of modes, exhibiting frequency dependency. Damping ratios for the specimen equipped with oil and viscoelastic dampers remained constant regardless of vibration amplitudes, whereas those for the specimen equipped with viscous dampers increased obviously with an increase in vibration amplitudes because of the viscosity nonlinearity of the dampers. In very small‐amplitude vibrations, viscous and oil dampers provided much lower supplemental damping than the standard, whereas viscoelastic dampers could be very efficient. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
18.
Lydell Wiebe Constantin Christopoulos Robert Tremblay Martin Leclerc 《地震工程与结构动力学》2013,42(7):1069-1086
This paper presents the results of 56 large‐amplitude shake table tests of a 30% scale eight‐storey controlled rocking steel frame. No significant damage or residual deformations were observed after any of the tests. The frame had four possible configurations on the basis of combinations of two higher mode mitigation mechanisms. The first mitigation mechanism was formed by allowing the upper section of the frame to rock, so as to better control the mid‐height overturning moment. The second mitigation mechanism was formed by replacing the conventional first‐storey brace with a self‐centering energy dissipative (SCED) brace, so as to better control the base shear. The mechanisms had little effect during records where higher mode effects were not apparent, but they substantially reduced the shear and overturning moment envelopes, as well as the peak floor accelerations, during more demanding records. The reduction in storey shears led to similarly reduced brace force demands. Although the peak force demands in the columns were not reduced by as much as the frame overturning moments, using an upper rocking joint allowed the column demands to be estimated without the need to assume a lateral force distribution. The tests demonstrated that multiple force‐limiting mechanisms can be used to provide better control of peak seismic forces without excessive increases in drift demands, thus enabling more reliable capacity design. These results are expected to be widely applicable to structures where the peak seismic forces are significantly influenced by higher mode effects. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
19.
Taichiro Okazaki Masayoshi Nakashima Keiichiro Suita Tomohiro Matusmiya 《地震工程与结构动力学》2007,36(1):35-53
Interaction between the external wall cladding and the seismic load resisting frame was examined in a full‐scale cyclic loading test of a three‐storey steel building structure. The building specimen had Autoclaved Lightweight Concrete (ALC, also designated as Autoclaved Aerated Concrete) panels installed and anchored to the structural frame as external wall cladding, using a standard Japanese method developed following the 1995 Kobe earthquake. ALC panelling is among the most widely used material for claddings in Japan. In the test, the ALC panel cladding contributed little to the stiffness and strength of the overall structure, even under a very large storey drift of 0.04 rad. No visible damage was noted in the ALC panels other than minor cracks and spalling of the bottom of the panels in the first storey. Consequently, in a Japanese steel building with properly installed ALC panel cladding, the structural frame is likely to be little affected by its cladding, and the ALC panels are capable of accommodating the maximum storey drift generally considered in structural design without sustaining discernible damage. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
20.
Dynamic characteristics of a base isolated building from ambient vibration measurements and low level earthquake shaking 总被引:3,自引:0,他引:3
C. E. Ventura W. D. Liam Finn J. -F. Lord N. Fujita 《Soil Dynamics and Earthquake Engineering》2003,23(4):313-322
Ambient vibration tests were conducted on a base-isolated apartment building in Takamatsu, Japan, to determine the mode shapes and the associated natural frequencies and damping ratios at very low levels of excitation. The latest developments in signal analysis for modal decomposition are used to analyze the ambient response data. A finite element model of the building and isolators was calibrated and refined using the experimental results from the ambient vibration tests. This model was then used to simulate the recorded response of the building under excitation from a small earthquake. The finite element model, calibrated by ambient vibration data and the low level of earthquake shaking, provides the starting point for modelling the non-linear response of the building when subjected to strong shaking. 相似文献