首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Civil engineering structures are often subjected to multidirectional actions such as earthquake ground motion, which lead to complex structural responses. The contributions from the latter multidirectional actions to the response are highly coupled, leading to a MIMO system identification problem. Compared with single‐input, multiple‐output (SIMO) system identification, MIMO problems are more computationally complex and error prone. In this paper, a new system identification strategy is proposed for civil engineering structures with multiple inputs that induce strong coupling in the response. The proposed solution comprises converting the MIMO problem into separate SIMO problems, decoupling the outputs by extracting the contribution from the respective input signals to the outputs. To this end, a QR factorization‐based decoupling method is employed, and its performance is examined. Three factors, which affect the accuracy of the decoupling result, including memory length, input correlation, and system damping, are investigated. Additionally, a system identification method that combines the autoregressive model with exogenous input (ARX) and the Eigensystem Realization Algorithm (ERA) is proposed. The associated extended modal amplitude coherence and modal phase collinearity are used to delineate the structural and noise modes in the fitted ARX model. The efficacy of the ARX‐ERA method is then demonstrated through identification of the modal properties of a highway overcrossing bridge. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
A procedure to estimate the seismic motion at the base of a building from measured acceleration response at two or more floors is presented. The proposed method is comprised of two steps. In the first step, the dynamic characteristics of the building are inferred by using an output‐only system identification procedure. In the second step, the motion of the base of the building is estimated by using the transfer function of a simplified building model consisting of a shear and flexural continuous beam together with dynamic properties obtained in the first step. The proposed method is validated first with an analytical model subjected to the 1940 El Centro ground motion and then with an instrumented building in California that experienced the 1994 Northridge earthquake, and the ground motions at the base of the building are available. It is shown that the proposed method is capable of providing very good estimates of the motion at the base. The use of the proposed method is finally illustrated on an instrumented building, where the sensor at the base of the building did not function during the 1994 Northridge earthquake. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
The Vincent Thomas Bridge in the Los Angeles metropolitan area, is a critical artery for commercial traffic flow in and out of the Los Angeles Harbor, and is at risk in the seismically active Southern California region, particularly because it straddles the Palos Verdes fault zone. A combination of linear and non‐linear system identification techniques is employed to obtain a complete reduced‐order, multi‐input–multi‐output (MIMO) dynamic model of the Vincent Thomas Bridge based on the dynamic response of the structure to the 1987 Whittier and 1994 Northridge earthquakes. Starting with the available acceleration measurements (which consists of 15 accelerometers on the bridge structure and 10 accelerometers at various locations on its base), an efficient least‐squares‐based time‐domain identification procedure is applied to the data set to develop a reduced‐order, equivalent linear, multi‐degree‐of‐freedom model. Although not the main focus of this study, the linear system identification method is also combined with a non‐parametric identification technique, to generate a reduced‐order non‐linear mathematical model suitable for use in subsequent studies to predict, with good fidelity, the total response of the bridge under arbitrary dynamic environments. Results of this study yield measurements of the equivalent linear modal properties (frequencies, mode shapes and non‐proportional damping) as well as quantitative measures of the extent and nature of non‐linear interaction forces arising from strong ground shaking. It is shown that, for the particular subset of observations used in the identification procedure, the apparent non‐linearities in the system restoring forces are quite significant, and they contribute substantially to the improved fidelity of the model. Also shown is the potential of the identification technique under discussion to detect slight changes in the structure's influence coefficients, which may be indicators of damage and degradation in the structure being monitored. Difficulties associated with accurately estimating damping for lightly damped long‐span structures from their earthquake response are discussed. The technical issues raised in this paper indicate the need for added spatial resolution in sensor instrumentation to obtain identified mathematical models of structural systems with the broadest range of validity. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

4.
This paper describes the identification of finite dimensional, linear, time‐invariant models of a 4‐story building in the state space representation using multiple data sets of earthquake response. The building, instrumented with 31 accelerometers, is located on the University of California, Irvine campus. Multiple data sets, recorded during the 2005 Yucaipa, 2005 San Clemente, 2008 Chino Hills and 2009 Inglewood earthquakes, are used for identification and validation. Considering the response of the building as the output and the ground motion as the input, the state space models that represent the underlying dynamics of the building in the discrete‐time domain corresponding to each data set are identified. The time‐domain Eigensystem Realization Algorithm with the Observer/Kalman filter identification procedure are adopted in this paper, and the modal parameters of the identified models are consistently determined by constructing stabilization diagrams. The four state space models identified demonstrate that the response of the building is amplitude dependent with the response frequency and damping, being dependent on the magnitude of ground excitation. The practical application of this finding is that the consistency of this building response to future earthquakes can be quickly assessed, within the range of ground excitations considered (0.005g–0.074g), for consistency with prior response—this assessment of consistent response is discussed and demonstrated with reference to the four earthquake events considered in this study. Inclusion of data sets relating to future earthquakes will enable the findings to be extended to a wider range of ground excitation magnitudes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
Seismic isolation devices and technology have been developed in the last two decades and the first seismic‐isolated bridge, Bai‐Ho Bridge, in Taiwan was completed in 1999. This bridge was equipped with a seismic monitoring system under the Taiwan Strong Motion Instrumentation Program (TSMIP). On 22 October 1999, a moderate earthquake took place and struck the bridge. The seismic monitoring sensors were normally triggered and produced an intact time history for the health monitoring of the bridge system. The data set provided valuable records about the seismic response of the isolation bridge structure. This paper uses this data to explore the vibration mechanism of Bai‐Ho Bridge. The analysis includes (1) the global dynamic behavior identification and (2) the local component mechanism of the bridge such as the LRB and boundary condition between the deck and the abutments. Both the EMD+HHT method and the non‐linear parametric model were used to identify the model of the bridge structure. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

6.
城市高架桥合理抗震体系选择与经济性对比   总被引:1,自引:0,他引:1  
探讨了基于两水准设防的城市高架桥的合理抗震设防标准与相应的结构性能目标.选取两座典型的城市高架桥结构,包括一座正线桥和一座匝道桥,分别采用延性抗震体系和减、隔震体系进行结构抗震设计.对比了不同结构抗震体系所对应的结构在各水准地震作用下具体抗震性能表现,结果表明减、隔震体系具有更优的抗震性能.在此基础上,进一步从经济性的...  相似文献   

7.
This paper addresses the issue of structural system identification using earthquake‐induced structural response. The proposed methodology is based on the subspace identification algorithm to perform identification of structural dynamic characteristics using input–output seismic response data. Incorporated with subspace identification algorithm, a scheme to remove spurious modes is also used to identify real system poles. The efficiency of the proposed method is shown by the analysis of all measurement data from all measurement directly. The recorded seismic response data of three structures (one 7‐story RC building, one midisolation building, and one isolated bridge), under Taiwan Strong Motion Instrumentation Program, are analyzed during the past 15 years. The results present the variation of the identified fundamental modal frequencies and damping ratios from all the recorded seismic events that these three structures had encountered during their service life. Seismic assessment of the structures from the identified system dynamic characteristics during the period of their service is discussed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
This paper presents the application of system identification (SI) to long‐span cable‐supported bridges using seismic records. The SI method is based on the System Realization using Information Matrix (SRIM) that utilizes correlations between base motions and bridge accelerations to identify coefficient matrices of a state‐space model. Numerical simulations using a benchmark cable‐stayed bridge demonstrate the advantages of this method in dealing with multiple‐input multiple‐output (MIMO) data from relatively short seismic records. Important issues related to the effects of sensor arrangement, measurement noise, input inclusion, and the types of input with respect to identification results are also investigated. The method is applied to identify modal parameters of the Yokohama Bay Bridge, Rainbow Bridge, and Tsurumi Fairway Bridge using the records from the 2004 Chuetsu‐Niigata earthquake. Comparison of modal parameters with the results of ambient vibration tests, forced vibration tests, and analytical models are presented together with discussions regarding the effects of earthquake excitation amplitude on global and local structural modes. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

9.
The paper presents a computationally efficient algorithm to integrate a probabilistic, non-Gaussian parameter estimation approach for nonlinear finite element models with the performance-based earthquake engineering (PBEE) framework for accurate performance evaluations of instrumented civil infrastructures. The algorithm first utilizes a minimum variance framework to fuse predictions from a numerical model of a civil infrastructure with its measured behavior during a past earthquake to update the parameters of the numerical model that is, then, used for performance prediction of the civil infrastructure during future earthquakes. A nonproduct quadrature rule, based on the conjugate unscented transformation, forms an enabling tool to drive the computationally efficient model prediction, model-data fusion, and performance evaluation. The algorithm is illustrated and validated on Meloland Road overpass, a heavily instrumented highway bridge in El Centro, CA, which experienced three moderate earthquake events in the past. The benefits of integrating measurement data into the PBEE framework are highlighted by comparing damage fragilities of and annual probabilities of damages to the bridge estimated using the presented algorithm with that estimated using the conventional PBEE approach.  相似文献   

10.
The performance of a building under wind and seismic loads depends on stiffness and mass distribution, and may be estimated using finite element codes. Experience has, however, shown that such finite element models often fail to predict accurately the fundamental natural frequencies. Usually the frequencies will be underestimated, that is the building will turn out to be stiffer than anticipated, meaning the design would usually be conservative. On the other hand, effects like torsional eccentricity and foundation compliance may not be correctly modelled, which could be less desirable. A full understanding of linear performance under lateral loads can be obtained through experimental evaluation of the vibration modes. Traditionally only a limited range of modal analysis procedures and software has been applied to civil applications and the ‘special case’ where no input forces can be measured has been the usual situation for large civil structures. Recent developments in system identification, which is the set of procedures to build mathematical models of the dynamic structural systems based on measured data, have added significantly to the potential of ambient vibration or ‘output only’ testing. The aim of the research reported here has been to apply and evaluate the procedures on typical buildings. The procedures are briefly explained and two experimental programmes are then described; a long‐term tremor monitoring exercise on a 280m office tower and an ambient vibration survey of a smaller office block. The different forms of response data are examined to study the performance of the analysis procedures and expose benefits and limitations in their use. There is a growing interest in output‐only modal analysis procedures in civil engineering. The experience reported in this paper has shown that quick and reliable estimation of mode shapes and frequencies can be obtained, even with small amounts of data. Judgement of modal participation and damping ratios requires more detailed study yet the results are at least as convincing as existing and relatively limited frequency domain methods. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

11.
A simple and effective procedure for conducting the free vibration test on highway bridges is presented. The impulsive force in each direction is generated by a loaded truck that either stops suddenly or falls down from a rigid block. The feasibility of the procedure is demonstrated in identification of the dynamic properties, i.e. the vibration frequencies, mode shapes, and damping ratios, of a three-span box-girder concrete bridge using the Ibrahim Time-Domain (ITD) technique. Up to 14 modes have been identified for the present case. For the purpose of verification, ambient vibration tests were also carried out, with the data processed by the random decrement (Randomdec) technique to yield the free vibration response, followed by the ITD technique. The dynamic properties identified from the two types of test correlate very well with each other, indicating the validity of each procedure described herein. Although many more modes can be identified from the free vibration test because of the higher quality of data produced, the easiness and general applicability of the ambient vibration test can still be appreciated. A comparison of the experimental results with those by the finite element method indicated a lesser degree of correlation, implying that the finite element model adopted in design requires further refinement, say, through a more realistic evaluation of the boundary conditions, geometric and material properties of the bridge. Copyright © 1999 John Wiley & Sons Ltd.  相似文献   

12.
This paper addresses the issue of system identification for linear structural systems using earthquake induced time histories of the structural response. The proposed methodology is based on the Eigensystem Realization Algorithm (ERA) and on the Observer/Kalman filter IDentification (OKID) approach to perform identification of structural systems using general input–output data via Markov parameters. The efficiency of the proposed technique is shown by numerical examples for the case of eight-storey building finite element models subjected to earthquake excitation and by the analysis of the data from the dynamic response of the Vincent-Thomas cable suspension bridge (Long Beach, CA) recorded during the Whittier and the Northridge earthquakes. The effects of noise in the measurements and of inadequate instrumentation are investigated. It is shown that the identified models show excellent agreement with the real systems in predicting the structural response time histories when subjected to earthquake-induced ground motion. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

13.
移动质量-简支梁系统的参数辨识   总被引:7,自引:1,他引:7  
给出了移动质量-简支梁系统的动力学方程,并用基于Hamilton原理的结构动响应算法对方程进行数值求解。然后介绍了一种新的从自由响应数据识别时变参数结构系统的伪模态参数的方法,并将该方法引入用于研究移动质量-简支梁系统的参数辩识问题。  相似文献   

14.
地震前兆台网的运行直接影响产出的观测数据质量。观测数据平均连续率和平均数据完整率可以反映地震前兆台网的运行质量。对中国地震背景场探测项目试行期间(2014年)及正式启动后2015年度的观测数据质量,从以上2个指标进行分析,并对比原有仪器运行质量,可知背景场项目试运行期间,各学科台网投入仪器运行稳定,观测数据符合相关要求,总体质量良好,观测仪器可以投入正式运行。  相似文献   

15.
A magnitude 4.3 earthquake occurred near Pacoima Dam on 13 January 2001. An accelerometer array that had been upgraded after the Northridge earthquake recorded the motion with 17 channels on the dam and the dam–foundation interface. Using this data, properties of the first two modes are found from a system identification study. Modal properties are also determined from a forced vibration experiment performed in 2002 and indicate a significantly stiffer system than is estimated from the 2001 earthquake records. The 2001 earthquake, although small, must have induced temporary nonlinearity. This has implications for structural health monitoring. The source of the nonlinear behaviour is believed to be loss of stiffness in the foundation rock. A finite element model of Pacoima Dam is constructed and calibrated to match modal properties determined from the system identification study. A dynamic simulation of the 2001 earthquake response produces computed motions that agree fairly well with the recorded ones. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

16.
随机子空间方法在桥塔模态参数识别中的应用   总被引:3,自引:0,他引:3  
基于环境振动的结构模态参数识别方法正逐渐成为国内外研究的一大热点。环境振动方法就是仅仅利用结构测试的输出信号进行结构的模态参数识别,随机子空间方法就是其中的一种。随机子空间法是近年来发展起来的一种线性系统辩识方法,可以有效地从环境激励的结构响应中获取模态参数。它属于时域的方法,该方法不需要进行FFT变换,它不仅可以识别结构的频率,而且可以识别结构的阻尼和振型。文章首先介绍了随机子空间的理论,然后用该方法对正在施工中的南京长江三桥的南塔进行模态参数识别,通过与其他方法的识别结果进行比较,证明随机子空间方法不失为一种有效的模态参数识别方法。  相似文献   

17.
介绍了宁夏地震局前兆数据应用现状及存在的问题,根据各用户的数据需求设计出在线共享服务的解决方案。并具体介绍了该系统的主要模块功能及作用。对今后省局台网数据共享具有参考意义。  相似文献   

18.
Tracking modal parameters and estimating the current structural state of a building from seismic response measurements, particularly during strong earthquake excitations, can provide useful information for building safety assessment and the adaptive control of a structure. Therefore, online or recursive identification techniques need to be developed and implemented for building seismic response monitoring. This paper develops and examines different methods to track modal parameters from building seismic response data. The methods include recursive data‐driven subspace identification (RSI‐DATA) using Givens rotation algorithm, and RSI‐DATA using Bona fide algorithm. The question on how well the results of RSI‐DATA reflect the real condition is investigated and verified with a bilinear SDOF simulation study. Time‐varying modal parameters of a four‐story reinforced concrete school building are identified based on a series of earthquake excitations, including several seismic events, large and small. Discussions on the different methods' ability to track the time‐varying modal parameters are presented. The variation of the identified building modal frequencies and damping ratios from a series of event‐by‐event seismic responses, particularly before and after retrofitting of the building is also discussed. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

19.
Nonlinear finite element (FE) modeling has been widely used to investigate the effects of seismic isolation on the response of bridges to earthquakes. However, most FE models of seismic isolated bridges (SIB) have used seismic isolator models calibrated from component test data, while the prediction accuracy of nonlinear FE models of SIB is rarely addressed by using data recorded from instrumented bridges. In this paper, the accuracy of a state‐of‐the‐art FE model is studied through nonlinear FE model updating (FEMU) of an existing instrumented SIB, the Marga‐Marga Bridge located in Viña del Mar, Chile. The seismic isolator models are updated in 2 phases: component‐wise and system‐wise FEMU. The isolator model parameters obtained from 23 isolator component tests show large scatter, and poor goodness of fit of the FE‐predicted bridge response to the 2010 Mw 8.8 Maule, Chile Earthquake is obtained when most of those parameter sets are used for the isolator elements of the bridge model. In contrast, good agreement is obtained between the FE‐predicted and measured bridge response when the isolator model parameters are calibrated using the bridge response data recorded during the mega‐earthquake. Nonlinear FEMU is conducted by solving single‐ and multiobjective optimization problems using high‐throughput cloud computing. The updated FE model is then used to reconstruct response quantities not recorded during the earthquake, gaining more insight into the effects of seismic isolation on the response of the bridge during the strong earthquake.  相似文献   

20.
A new method of stiffness‐damping simultaneous identification of building structures is proposed using limited earthquake records. It is shown that when horizontal accelerations are recorded at the floors just above and below a specific storey in a shear building model, the storey stiffness and the damping ratio can be identified uniquely. The viscous damping coefficient and the linear hysteretic damping ratio can also be identified simultaneously in a numerical model structure. The accuracy of the present identification method is investigated through the actual limited earthquake records in a base‐isolated building. It is further shown that an advanced identification technique for mechanical properties of a Maxwell‐type model can be developed by combining the present method with a perturbation technique. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏