首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A versatile, simulation‐based framework for risk assessment and probabilistic sensitivity analysis of base‐isolated structures is discussed in this work. A probabilistic foundation is used to address the various sources of uncertainties, either excitation or structural, and to characterize seismic risk. This risk is given, in this stochastic setting, by some statistics of the system response over the adopted probability models and stochastic simulation is implemented for its evaluation. An efficient, sampling‐based approach is also introduced for establishing a probabilistic sensitivity analysis to identify the importance of each of the uncertain model parameters in affecting the overall risk. This framework facilitates use of complex models for the structural system and the excitation. The adopted structural model explicitly addresses nonlinear characteristics of the isolators and of any supplemental dampers, and the effect of seismic pounding of the base to the surrounding retaining walls. An efficient stochastic ground motion model is also discussed for characterizing future near‐fault ground motions and relating them to the seismic hazard for the structural site. An illustrative example is presented that emphasizes the results from the novel probabilistic sensitivity analysis and their dependence on seismic pounding occurrences and on addition of supplemental dampers. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
Buildings are continually subject to dynamic loads, such as wind load, seismic ground motion, and even the load from internal utility machines. The recent trend of constructing more flexible high‐rise buildings underscores the importance of including viscoelastic dampers in building designs. Viscoelastic dampers are used to control the dynamic response of a building. If the seismic design is based only on the linear response spectrum, considerable error may occur when calculating the seismic response of a building; rubber viscoelastic dampers show non‐linear hysteretic damping that is quite different from viscous damping. This study generated a non‐linear response spectrum using a non‐linear oscillator model to simulate a building with viscoelastic dampers installed. The parameters used in the non‐linear damper model were obtained experimentally from dynamic loading tests. The results show that viscoelastic dampers effectively reduce the seismic displacement response of a structure, but transmit more seismic force to the structure, which essentially increases its seismic acceleration response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
The present study deals with the non‐linear stochastic dynamic analysis of a soil–structure interacting system. The ultimate objective is to determine the risk of damage to the system due to liquefaction under a wide range of earthquake intensities. A Monte Carlo simulation approach is followed in conjunction with advanced finite element procedures. The stochastic spatial variability of soil properties and the randomness of the seismic excitation are taken into account in order to estimate the statistics of the response, measured in terms of uniform foundation settlement and tilting. Specifically, soil properties are modelled as non‐Gaussian random fields and seismic excitations as non‐stationary random processes. The probabilistic characteristics of the stochastic field modelling soil properties are established from in situ tests. The risk of damage to the soil–structure system due to liquefaction is assessed by establishing fragility curves, which are of paramount importance for risk assessment and management studies of such systems. Fragility curves express the probability of exceeding various thresholds in the response. The relative effect of the variability of various soil parameters on the variability of the response is also examined. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

4.
To address challenges in stochastic seismic analysis of nonlinear structures, this paper further develops a recently proposed Gaussian mixture–based equivalent linearization method (GM‐ELM). The GM‐ELM uses a Gaussian mixture distribution model to approximate the probabilistic distribution of a nonlinear system response. Using properties of the Gaussian mixture model, GM‐ELM can decompose the non‐Gaussian response of a nonlinear system into multiple Gaussian responses of linear single–degree of freedom oscillators. With the set of the equivalent linear systems identified by GM‐ELM, response statistics as crossing rate and first‐passage probability can be computed conveniently using theories of linear random vibration analysis. However, the original version of GM‐ELM may lead to an inaccurate estimate because of the heuristic parameters of the linear system introduced to supplement insufficient information. To overcome this limitation and define unique equivalent linear systems, this paper proposes a further developed version of GM‐ELM, which uses a mixture of bivariate Gaussian densities instead of univariate models. Moreover, to facilitate the use of elastic response spectra for estimating the mean peak responses of a nonlinear structure, a new response spectrum combination rule is proposed for GM‐ELM. Two numerical examples of hysteretic structural systems are presented in this paper to illustrate the application of the bivariate GM‐ELM to nonlinear stochastic seismic analysis. The analysis results obtained by the bivariate GM‐ELM are compared with those obtained by the univariate GM‐ELM, the conventional equivalent linearization method, the tail equivalent linearization method, and Monte Carlo simulation. The supporting source code and data are available for download at https://github.com/yisangri/GitHub‐bGM‐ELM‐code.git  相似文献   

5.
The dynamic response of bridge piers with aseismic devices to earthquake excitation is evaluated by the stochastic equivalent linearization technique. The seismic acceleration is schematized through a Gaussian stationary random process. The pier is considered linear elastic, the span is idealized as a rigid mass, the restoring force of the device is represented through a non-linear differential model. The study of the complex modes of the linearized system gives an interpretation of the mechanical behaviour, leads to a formally elementary solution and highlights some phenomena which are typical of the hysteretic systems, particularly of those marked by weak hardening. Even though the solution is limited to the stationary field, it brings out several noteworthy considerations about the effective non stationary behaviour of the structure. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

6.
The tuned mass damper inerter (TMDI) couples the classical tuned mass damper (TMD) with an inerter, a mechanical device whose generated force is proportional to the relative acceleration between its terminals, thus providing beneficial mass‐amplification effects. This paper deals with a dynamic layout in which the TMDI is installed below the isolation floor of base‐isolated structures in order to enhance the earthquake resilience and reduce the displacement demand. Unlike most of the literature studies that assumed a linearized behavior of the isolators, the aim of this paper is to investigate the effectiveness of the TMDI while accounting for the nonlinearity of the isolators. Two nonlinear constitutive behaviors are considered, a Coulomb friction model and a Bouc‐Wen hysteretic model, representative of friction pendulum and of lead‐rubber‐bearing isolators, respectively. Optimal design is based on the stochastic dynamic analysis of the system, by modeling the base acceleration as a Kanai‐Tajimi filtered stationary random process and resorting to the stochastic linearization technique to handle the nonlinear terms. Different tuning criteria based on displacement, acceleration, and energy‐based performance indices are defined, and their implications in a design process are discussed. It is proven that the improved robustness of the TMDI reduces its performance sensitivity to the tuning frequency and to the earthquake frequency content, which are well‐known shortcomings of TMD‐like systems. This important feature makes the TMDI particularly suitable for nonlinear base‐isolated structures that are affected by unavoidable uncertainties in the isolators' properties and that may experience changes of isolators effective stiffness depending on the excitation level.  相似文献   

7.
Earthquake ground motion records are nonstationary in both amplitude and frequency content. However, the latter nonstationarity is typically neglected mainly for the sake of mathematical simplicity. To study the stochastic effects of the time‐varying frequency content of earthquake ground motions on the seismic response of structural systems, a pair of closely related stochastic ground motion models is adopted here. The first model (referred to as ground motion model I) corresponds to a fully nonstationary stochastic earthquake ground motion model previously developed by the authors. The second model (referred to as ground motion model II) is nonstationary in amplitude only and is derived from the first model. Ground motion models I and II have the same mean‐square function and global frequency content but different features of time variation in the frequency content, in that no time variation of the frequency content exists in ground motion model II. New explicit closed‐form solutions are derived for the response of linear elastic SDOF and MDOF systems subjected to stochastic ground motion model II. New analytical solutions for the evolutionary cross‐correlation and cross‐PSD functions between the ground motion input and the structural response are also derived for linear systems subjected to ground motion model I. Comparative analytical results are presented to quantify the effects of the time‐varying frequency content of earthquake ground motions on the structural response of linear elastic systems. It is found that the time‐varying frequency content in the seismic input can have significant effects on the stochastic properties of system response. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
基础隔震结构的耗能分析   总被引:5,自引:0,他引:5  
采用Bouc-wen模型,利用状态空间迭代法,对基础隔震结构进行了多质点的弹塑性时程分析,并根据此结果,利用能量方程,求得隔震结构的各项能量,绘制了各能量项时程曲线。以一实际工程为例,求得隔震结构的各项耗能情况,说明了基础隔震结构以减少地震输入和隔震层滞回耗能来减小对上部结构的损坏。  相似文献   

9.
Analysis of civil structures at the scale of life‐cycle requires stochastic modeling of degradation. Phenomena causing structures to degrade are typically categorized as aging and point‐in‐time overloads. Earthquake effects are the members of the latter category this study deals with in the framework of performance‐based earthquake engineering (PBEE). The focus is structural seismic reliability, which requires modeling of the stochastic process describing damage progression, because of subsequent events, over time. The presented study explicitly addresses this issue via a Markov‐chain‐based approach, which is able to account for the change in seismic response of damaged structures (i.e. state‐dependent seismic fragility) as well as uncertainty in occurrence and intensity of earthquakes (i.e. seismic hazard). The state‐dependent vulnerability issue arises when the seismic hysteretic response is evolutionary and/or when the damage measure employed is such that the degradation increment probabilistically depends on the conditions of the structure at the time of the shock. The framework set up takes advantage also of the hypotheses of classical probabilistic seismic hazard analysis, allowing to separate the modeling of the process of occurrence of seismic shocks and the effect they produce on the structure. It is also discussed how the reliability assessment, which is in closed‐form, may be virtually extended to describe a generic age‐ and state‐dependent degradation process (e.g. including aging and/or when aftershock risk is of interest). Illustrative applications show the options to calibrate the model and its potential in the context of PBEE. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
In this paper, seismic analysis of plane RC frame structures with High Damping Rubber Bearings (HDRBs) base-isolation systems is performed in the non linear range. For RC members, a modified version of hysteretic Park model is used. For HDRB isolators, a new hysteretic model is presented, which is able to accurately predict the mechanical response in the large strain range. The dynamic equilibrium equations are solved making use, at each time step, of a block iterative Newton–Raphson scheme: the frame is divided into superelements (beams and columns) with master nodes at the extremities and internal local nodes for the computation of relations between end moments and relative rotations at superelement extremities. The effectiveness of HDRB base-isolation systems to reduce inelastic deformations in the RC superstructures is investigated through some numerical examples. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

11.
To verify the importance of the non‐stationary frequency characteristic of seismic ground motion, a joint time–frequency analysis technique of time signals, called chirplet‐based signal approximation, is developed to extract the non‐stationary frequency information from the recorded data. The chirplet‐based signal approximation is clear in concept, similar to Fourier Transform in mathematical expressions but with different base functions. Case studies show that the chirplet‐based signal approximation can represent the joint time–frequency variation of seismic ground motion quite well. Both the random models of uniform modulating process and evolutionary process are employed to generate artificial seismic waves. The joint time–frequency modulating function in the random model of evolutionary process is determined by chirplet‐based signal approximation. Finally, non‐linear response analysis of a SODF system and a frame structure is performed based on the generated artificial seismic waves. The results show that the non‐stationary frequency characteristic of seismic ground motion can significantly change the non‐linear response characteristics of structures, particularly when a structure goes into collapse phase under seismic action. It is concluded that non‐stationary frequency characteristic of seismic ground motion should be considered for the assessment of seismic capacity of structures. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

12.
Comparative study of the inelastic response of base isolated buildings   总被引:1,自引:0,他引:1  
This article presents a numeric comparative study of the inelastic structural response of base isolated buildings. The comparative study includes the following isolation systems: laminated rubber bearings, New Zealand one, pure friction and the frictional pendulum ones. The study is based on obtaining non‐linear response spectra for various design parameters using six earthquake records. Usually the base isolation of a new building seeks to maintain the structure in the linear elastic range. The response of old weak buildings or the response of new ones subjected to extreme earthquakes may not be, necessarily, in the aforementioned ideal elastic range. Consequently, it is important to characterize the response of isolated buildings responding inelastically. A conclusion from this research is that the isolators affect significantly the structural response of weak systems. Rubber isolators seem slightly less sensitive to plastification that may occur in the structure compared to friction isolators. Ductility demands in the structure are affected significantly by friction and neoprene protected systems, in particular sliding ones where larger demands are obtained. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

13.
The response of multi‐storey structures can be controlled under earthquake actions by installing seismic isolators at various storey levels. By vertically distributing isolation devices at various elevations, the designer is provided with numerous options to appropriately adjust the seismic performance of a building. However, introducing seismic isolators at various storey levels is not a straightforward task, as it may lead to favourable or unfavourable structural behaviour depending on a large number of factors. As a consequence, a rather chaotic decision space of seismic isolation configurations arises, within which a favourable solution needs to be located. The search for favourable isolators' configurations is formulated in this work as a single‐objective optimization task. The aim of the optimization process is to minimize the maximum floor acceleration of the building under consideration, while constraints are specified to control the maximum interstorey drift, the maximum base displacement and the total seismic isolation cost. A genetic algorithm is implemented to perform this optimization task, which selectively introduces seismic isolators at various elevations, in order to identify the optimal configuration for the isolators satisfying the pre‐specified constraints. This way, optimized earthquake response of multi‐storey buildings can be obtained. The effectiveness of the proposed optimization procedure in the design of a seismically isolated structure is demonstrated in a numerical study using time‐history analyses of a typical six‐storey building. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
In this study, a series of shaking table tests are carried out on scaled models of two seismically isolated highway bridges to investigate the effect of rocking motion and vertical acceleration on seismic performance of resilient sliding isolators. In addition, performance of RSI is compared with system having solely natural rubber bearings. Test results show that variation of normal force on sliders due to rocking effect and vertical acceleration makes no significant difference in response of RSI systems. In addition, analytical response of prototype isolated bridge and the model used in experiments is obtained analytically by using non‐linear model for isolation systems. It is observed that for seismically isolated bridges, dynamic response of full‐scale complex structures can be predicted with acceptable accuracy by experiments using a simple model of the structure. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

15.
Because a conventional isolation system with constant isolation frequency is usually a long‐period dynamic system, its seismic response is likely to be amplified in earthquakes with strong long‐period wave components, such as near‐fault ground motions. Seismic isolators with variable mechanical properties may provide a promising solution to alleviate this problem. To this end, in this work sliding isolators with variable curvature (SIVC) were studied experimentally. An SIVC isolator is similar to a friction pendulum system (FPS) isolator, except that its sliding surface has variable curvature rather being spherical. As a result, the SIVC's isolation stiffness that is proportional to the curvature becomes a function of the isolator displacement. By appropriately designing the geometry of the sliding surface, the SIVC is able to possess favorable hysteretic behavior. In order to prove the applicability of the SIVC concept, several prototype SIVC isolators, whose sliding surfaces are defined by a sixth‐order polynomial function, were fabricated and tested in this study. A cyclic element test on the prototype SIVC isolators and a shaking table test on an SIVC isolated steel frame were all conducted. The results of both tests have verified that the prototype SIVC isolators do indeed have the hysteretic property of variable stiffness as prescribed by the derived formulas in this study. Moreover, it is also demonstrated that the proposed SIVC is able to effectively reduce the isolator drift in a near‐fault earthquake with strong long‐period components, as compared with that of an FPS system with the same friction coefficient. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
This article presents a physical model for frictional pendulum isolators (FPS) that is ready to be implemented in most commercial software. The model is capable of accounting for effects such as large deformations, sticking, and uplift and impact by sensing the normal loads in the isolators through a gap element. Sticking has been incorporated into the model by extending the Park–Wen hysteretic model to the case of large deformations. The proposed model has been tested against a theoretically ‘exact’ formulation leading to essentially identical results. To facilitate its use, the physical FPS model has been cast into a typical non‐linear structural element format, i.e. with deformation as input and restoring force as output. Examples of a building and a bridge have been chosen to show the potential of the element and to provide further insight into the earthquake response of structures with FPS isolators; in particular, in aspects such as the orientation in placement of the isolator, sticking, P? Δ, and other large deformation effects. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

17.
Bridge seismic isolation strategy is based on the reduction of shear forces transmitted from the superstructure to the piers by two means: shifting natural period and earthquake input energy reduction by dissipation concentrated in protection devices. In this paper, a stochastic analysis of a simple isolated bridge model for different bridge and device parameters is conducted to assess the efficiency of this seismic protection strategy. To achieve this aim, a simple nonlinear softening constitutive law is adopted to model a wide range of isolation devices, characterized by only three essential mechanical parameters. As a consequence of the random nature of seismic motion, a probabilistic analysis is carried out and the time modulated Kanai-Tajimi stochastic process is adopted to represent the seismic action. The response covariance in the state space is obtained by solving the Lyapunov equation for a stochastic linearized system. After a sensitivity analysis, the failure probability referred to extreme displacement and the mean value of dissipated energy are assessed by using the introduced stochastic indices of seismic bridge protection efficiency. A parametric analysis for protective devices with different mechanical parameters is developed for a proper selection of parameters of isolation devices under different situations.  相似文献   

18.
A wavelet‐based stochastic formulation has been presented in this paper for the seismic analysis of a base‐isolated structural system which is modelled as a two‐degree‐of‐freedom (2‐DOF) system. The ground motion has been modelled as a non‐stationary process (both in amplitude and frequency) by using modified Littlewood–Paley basis wavelets. The proposed formulation is based on replacing the non‐linear system by an equivalent linear system with time‐dependent damping properties. The expressions of the instantaneous damping and the power spectral density function (PSDF) of the superstructure response have been obtained in terms of the functionals of input wavelet coefficients. The proposed formulation has been validated by simulating a ground motion process. The effect of the frequency non‐stationarity on the non‐linear response has also been studied in detail, and it has been clearly shown how ignoring the frequency non‐stationarity in the ground motion leads to inaccurate non‐linear response calculations. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

19.
This paper carries out a parametrical study of the pounding phenomenon associated with the seismic response of multi‐span simply supported bridges with base isolation devices. In particular, the analyses focus on the causal relationship between pounding and the properties of a spatially varying earthquake ground motion. In order to include the effect of the torsional component of pounding forces on the seismic response of the whole structure, a three‐dimensional (3D) finite element model has been defined and 3D non‐linear time‐history analyses have been performed. A parametrical study on the size of the gaps between adjacent bridge decks has highlighted that the pounding effects are amplified when the spatially varying ground motion time histories at each support are considered. Because of a spatially varying input, the pounding forces can assume values 3–4 times larger than those derived by a conventional seismic analysis with uniform input or with spatial input but considering ground motion wave passage effect only. The numerical results show that in order to achieve an acceptably safe structural performance during seismic events, a correct design of the isolation devices should take into account the relative displacements calculated by means of a non‐linear time‐history analysis with multi‐support excitation. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

20.
Nonlinear viscous dampers are supplemental devices widely used for enhancing the performance of structural systems exposed to seismic hazard. A rigorous evaluation of the effect of these damping devices on the seismic performance of a structural system should be based on a probabilistic approach and take into account the evolutionary characteristics of the earthquake input and of the corresponding system response. In this paper, an approximate analytical technique is proposed for studying the nonstationary stochastic response characteristics of hysteretic single degree of freedom systems equipped with viscous dampers subjected to a fully nonstationary random process representing the seismic input. In this regard, a stochastic averaging/linearization technique is utilized to cast the original nonlinear stochastic differential equation of motion into a simple first‐order nonlinear ordinary differential equation for the nonstationary system response variance. In comparison with standard linearization schemes, the herein proposed technique has the significant advantage that it allows to handle realistic seismic excitations with time‐varying frequency content. Further, it allows deriving a formula for determining the nonlinear system response evolutionary power spectrum. By this way, ‘moving resonance’ effects, related to both the evolutionary seismic excitation and the nonlinear system behavior, can be observed and quantified. Several applications involving various system and input properties are included. Furthermore, various response parameters of interest for the seismic performance assessment are considered as well. Comparisons with pertinent Monte Carlo simulations demonstrate the reliability of the proposed technique. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏