首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
EPA's approach for developing, evaluating, and selecting ground water response actions at Superfund sites with contaminated ground water involves a series of key decisions to support necessary actions. These actions include the following:
Planning how the site will be managed
Determining data needs
Determining remedial action objectives
Developing alternatives
Selecting and implementing the remedy.
The key decisions should reflect a policy and decision-making approach developed within the framework of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA 1980) as amended by the Superfund Amendments and Reauthorization Act (SARA 1986) and program policies to implement these acts. This paper outlines a flexible, iterative process, described in detail in the Guidance on Remedial Actions for Contaminated Ground Water at Superfund Sites (U.S. EPA 1988), by which ground water remedies can be identified, evaluated, selected, and implemented at Superfund sites beginning with initial site investigation tasks and ending with evaluation of implemented actions. Proper consideration of the factors presented in this paper should result in an efficient, effective procedure for making remedial action decisions for contaminated ground water that ensures protection of human health and the environment.  相似文献   

2.
Contaminated groundwater in fractured bedrock can expose ecosystems to undesired levels of risk for extended periods due to prolonged back-diffusion from rock matrix to permeable fractures. Therefore, it is key to characterize the diffusive mass loading (intrusion) of contaminants into the rock matrix for successful management of contaminated bedrock sites. Even the most detailed site characterization techniques often fail to delineate contamination in rock matrix. This study presents a set of analytical solutions to estimate diffusive mass intrusion into matrix blocks, it is recovered by pumping and concentration rebound when pumping ceases. The analytical models were validated by comparing the results with (1) numerical model results using the same model parameters and (2) observed chloride mass recovery, rebound concentration, and concentration in pumped groundwater at a highly fractured bedrock site in Alberta, Canada. It is also demonstrated that the analytical solutions can be used to estimate the total mass stored in the fractured bedrock prior to any remediation thereby providing insights into site contamination history. The predictive results of the analytical models clearly show that successful remediation by pumping depends largely on diffusive intrusion period. The results of initial mass from the analytical model was used to successfully calibrate a three-dimensional discrete fracture network numerical model further highlighting the utility of the simple analytical solutions in supplementing the more detailed site numerical modeling. Overall, the study shows the utility of simple analytical methods to support long-term management of a contaminated fractured bedrock site including site investigations and complex numerical modeling.  相似文献   

3.
Strawberry Point, located on Hinchinbrook Island, Alaska, is the site of a Federal Aviation Administration air navigation facility that is contaminated with gasoline- and diesel-range hydrocarbons in soil and ground water. An air sparging system was installed to promote bioremediation in the zone of seasonal ground water fluctuation where the contaminant is concentrated. The sparge wells were placed in a homogeneous formation, consisting of fine-grain beach and eolian sands. The system was then evaluated to determine the ground water region of influence and optimum frequency of operation. Neutron probe borehole measurements of percentage; of fluid displacement during sparging at two wells revealed dynamic air distributions defined by an initial and relatively rapid expansion phase followed by a consolidation phase. Air distribution was stable within 12 hours after startup, reaching a peak air saturation of greater than 50 percent. The radius of peak expansion varied with time and depth, with measurable fluid displacement occurring beyond 12 feel from the sparge well near the water table. The percentage of air saturation stabilized within one hour following cutoff of the air flow, leaving pockets of entrapped air near the water table. When air injection was resumed, air saturation levels were found to be repeatable. The observations at this site indicated that the effective region of influence is relatively small and that frequent pulsing is needed to optimize oxygen distribution.  相似文献   

4.
Air sparging is a relatively new technique for the remediation of ground water contaminated with petroleum hydrocarbons. In this technique, air is injected below the water table, beneath the contaminated soil. Remediation occurs by a combination of contaminant partitioning into the vapor phase and enhanced biodegradation. The air is usually removed by vacuum extraction in the vadose zone.
The efficiency of remediation from air sparging is a function of the air flow pattern, although the distribution of the injected air is still poorly understood. Cross-borehole resistivity surveys were performed at a former service station in Florence, Oregon, to address this unknown. The resistivity measurements were made using six wells, one of which was the sparge well. Data were collected over a two-week period during and after several air injections, or sparge events. Resistivity images were calculated between wells using an algorithm that assumes axially symmetric structures. The movement of the injected air through time was defined by regions of large increases in resistivity, greater than 100 percent from the background. During early sparge times, air moved outward and upward from the injection point as it ascended to the unsaturated zone. At later sparge times, the air flow reached a somewhat stable cone-shaped pattern radiating out and up from the injection point. Two days after sparging was discontinued, a residue of entrained air remained in the saturated zone, as indicated by a zone of 60 to 80 percent water saturation.  相似文献   

5.
Vapor extraction (soil venting) has been demonstrated to be a successful and cost-effective remediation technology for removing VOCs from the vadose (unsaturated) zone. However, in many cases, seasonal water table fluctuations, drawdown associated with pump-and-treat remediation techniques, and spills involving dense, non-aqueous phase liquids (DNAPLS) create contaminated soil below the water table. Vapor extraction alone is not considered to be an optimal remediation technology to address this type of contamination.
An innovative approach to saturated zone remediation is the use of sparging (injection) wells to inject a hydrocarbon-free gaseous medium (typically air) into the saturated zone below the areas of contamination. The contaminants dissolved in the ground water and sorbed onto soil particles partition into the advective air phase, effectively simulating an in situ air-stripping system. The stripped contaminants are transported in the gas phase to the vadose zone, within the radius of influence of a vapor extraction and vapor treatment system.
In situ air sparging is a complex multifluid phase process, which has been applied successfully in Europe since the mid-1980s. To date, site-specific pilot tests have been used to design air-sparging systems. Research is currently underway to develop better engineering design methodologies for the process. Major design parameters to be considered include contaminant type, gas injection pressures and flow rates, site geology, bubble size, injection interval (areal and vertical) and the equipment specifications. Correct design and operation of this technology has been demonstrated to achieve ground water cleanup of VOC contamination to low part-per-billion levels.  相似文献   

6.
Analytical Model for Contaminant Mass Removal by Air Sparging   总被引:2,自引:0,他引:2  
An analytical model was developed lo predict the removal of volatile organic compounds (VOCs) from ground water by air sparging (AS). The model treats the air sparging zone as a completely mixed reactor subject to the removal of dissolved contaminants by volatilization, advection, and first-order decay Nonequilibrium desorption is approximated as a first-order mass transfer process. The model reproduces the tailing and rebound behavior often observed at AS sites, and would normally require the estimation of three site-specific parameters. Dimensional analysis demonstrates that predicted tailing can be interpreted in terms of kinetic desorption or diffusion of aqueous phase contaminants into discrete air channels. Related work is ongoing to test the model against field data.  相似文献   

7.
A large-scale air sparging/soil vapor extraction (AS/SVE) project constructed within coastal plain sediments in New Jersey has demonstrated substantial progress toward remediating ground water through removal of volatile organic compounds (VOCs). Potential concerns identified prior to project implementation regarding hydraulic mounding, reduction in hydraulic conductivity, development of air channels, and the absence of hydraulic containment were assessed and addressed through testing and operational features incorporated into the project. At the project site, AS/SVE has successfully reduced the presence of many VOCs to undetectable levels, while reducing the concentrations of the remaining VOCs by factors of two to 500. The physical agitation caused by air sparging, and incomplete transformation from sorbed and nonaqueous phases to the vapor phase, appears to temporarily increase VOC concentrations and/or mobility of dense nonaqueous phase liquids (DN APLs) within source areas at the project site, but this is addressed in terms of subsequent removal of VOCs by properly placed downgradient treatment lines and VOCs by properly placed downgradient treatment lines and DNAPL recovery wells. This case study identifies and evaluates project-specific features and provides empirical data for potential comparison to other candidates AS/SVE sites.  相似文献   

8.
Air sparging has proven to be an effective remediation technique for treating saturated soils and ground water contaminated by volatile organic compounds (VOCs). Since little is known about the system variables and mass transfer mechanisms important to air sparging, several researchers have recently performed laboratory investigations to study such issues. This paper presents the results of column experiments performed to investigate the behavior of dense nonaqueous phase liquids (DNAPFs). specifically trichloroethylene (TCE), during air sparging. The specific objectives of the study were (1) to compare the removal of dissolved TCE with the removal of dissolved light nonaqueous phase liquids (LNAPLs). such as benzene or toluene; (2) to determine the effect of injected air-flow rate on dissolved TCE removal; (3) to determine the effect of initial dissolved TCE concentration on removal efficiency; and (4) to determine the differences in removal between dissolved and pure-phase TCE. The test results showed that (1) the removal of dissolved TCE was similar to that of dissolved LNAPL: (2) increased air-injection rates led to increased TCE removal at lower ranges of air injection, but further increases at higher ranges of air injection did not increase the rate of removal, indicating a threshold removal rate had been reached; (3) increased initial concentration of dissolved TCE resulted in similar rates of removal: and (4) the removal of pure-phase TCE was difficult using a low air-injection rate, but higher air-injection rates led to easier removal.  相似文献   

9.
Analysis of the vapor in passive vapor samplers retrieved from a streambed in fractured rock terrain implied that volatile organic carbon (VOC) discharge from ground water to surface water substantially increased following installation of a contaminant recovery well using air rotary drilling. The air rotary technique forced air into the aquifer near the stream. The injection produced an upward hydraulic gradient that appears to have transported water and contaminants from deeper parts of the aquifer through fractures into shallow parts of the aquifer. Once in the shallow flow regime, the contamination was transported to the stream, where it discharged during the next several weeks following well installation. After the recovery well was activated and began continuously pumping contaminated ground water to a treatment facility, the VOC concentrations in the stream bottom passive vapor samplers decreased to below detectable concentrations, suggesting that the withdrawal had captured the contaminated ground water that previously had discharged to the stream.  相似文献   

10.
The New Jersey Department of Environmental Protection's Technical Regulations require the horizontal and vertical delineation of contamination. Monitor wells screened at increasingly deeper intervals are used to delineate vertical contamination. In New Jersey, the open interval in a bedrock well cannot exceed 7.6 m. Since contamination has been found at depths as great as 91.4 m in a production well in the study area, it would be prohibitively expensive to install monitor wells with 7.6 m open holes at ever-increasing depths until no contamination was found. Isolation of discrete zones in boreholes using pneumatic packers was implemented at a site in north central New Jersey. Ground water samples were collected from selected 6.1 m sections of boreholes drilled into fractured bedrock at three locations on the property and one offsite location. The ground water samples were analyzed in a field laboratory. The analytical results were used to determine the vertical extent of gasoline-related compounds dissolved in the ground water on the property and offsite. These compounds include benzene, ethylbenzene, methyl tertiary butyl ether, toluene, and xylenes. The four boreholes were converted into bedrock monitor wells. The intake interval for each of the wells was selected through evaluation of the vertical distribution of contaminants as determined from analytical results obtained from a field laboratory located onsite. Three wells are used for the recovery of contaminated ground water. The recovered water will be treated at the onsite air-stripping unit. The fourth well is used to chemically and hydraulically monitor the progress of the ground water recovery program.  相似文献   

11.
The Picillo Farm, EPA Superfund Site, in western Rhode Island was an unauthorized disposal site of hazardous organic chemicals. Predominantly organic contaminants have entered an aquifer comprised of layered glacial deposits and fractured bedrock and spread past the site boundaries with groundwater flow. Hydraulic conductivities in the glacial deposits range over two orders of magnitude and fractures and faults in the granitic bedrock further complicate the spreading of contaminants. Monitoring wells delineate two plumes that extend towards a fault-controlled valley with lakes and wetlands; one to the northwest and the other to the southwest. In this investigation we studied the electrical characteristics of both plumes.One dimensional Schlumberger depth soundings were conducted along several profile lines over the plumes and compared to those over non-contaminated sections of the site. With regard to the southwestern plume, high formation factors (ratio of bulk layer to pore water resistivity) between 12 and 45 were observed compared to values between 2.5 and 7.7 measured over the non-contaminated sections. Also, high values (> 5) of vertical electrical anisotropy (ratio of geoelectrically determined depth to high resistivity bedrock to drilled depth to bedrock) were measured over the contaminated part of the site. These values are extremely high compared to other non-contaminated sites (range: 2 to 3) in glacial stream channels of southern Rhode Island. Geoelectric measurements were affected by lateral effects. However, the consistency of high formation factors (11 to 35) and high vertical anisotropies (3 to 5) over the southwestern plume in comparison to low formation factors (3 to 8) and vertical anisotropies (1 to 1.5) over non-contaminated sites represents a marked difference between both sites. Overall, the Schlumberger depth soundings are less susceptible to near-surface lateral inhomogeneities than expected from other geoelectrical methods. Also, the disadvantage of a 1D interpretation was compensated by estimating resistivity and thickness ranges within the concept of non-uniqueness using the Dar Zarrouk parameters (Maillet, R., 1947. The fundamental equations of electrical prospecting. Geophysics, 12(4): 529–556.).The results over the northwestern plume, i.e. an area with higher contaminant concentration than the southwestern plume, were mixed and showed no consistent trends. Predominantly reducing conditions, as indicated by the presence of soluble ferric (FeII) iron hydroxides in ground water samples, increased the electrical conductivity. This is believed to have compensated the effect of high formation factors on the bulk saturated layer resistivity within the affected area.  相似文献   

12.
Air sparging has been used for several years as an in situ technique for removing volatile compounds from contaminated ground water, but few studies have been completed to quantify the extent of remediation. To gain knowledge of the air flow and water behavior around air injection wells, laboratory tests and model simulations were completed at three injection flow rates (62, 187, and 283 lpm) in a cylindrical reactor (diameter - 1.2 m, depth = 0.65 m). Measurements of the air flux distribution were made across the surface of the reactor at 24 monitoring locations, six radial positions equally spaced along two orthogonal transects. Simulations using a multiphase flow model called T2VOC were completed for a homogeneous, axisymmetric configuration. Input parameters were independently measured soil properties. In all the experiments, about 75 percent of the flow injected exited the water table within 30 cm of the sparge well. Predictions with T2VOC showed the same. The averages of four flux measurements at a particular distance from the sparge well compare satisfactorily with T2VOC predictions. Measured flux values at a given radius varied by more than a factor of two, but the averages were consistent between experiments and agreed well with T2VOC simulations. The T2VOC prediction of the radial extent of sparging coincided with the distance out to which air flow from the sparge well could not be detected in the reactor. The sparging pattern was relatively unaffected by the air injection rate over the range of conditions studied. Changes in the injection rate resulted in nearly proportional changes in flux rates.  相似文献   

13.
The basic physics of air flow through saturated porous media are reviewed and implications arc drawn for the practical application of air sparging. A conceptual model of the detailed behavior of an air sparging system is constructed using elements of multiphase flow theory and the results of recent experimental work. Implications of the conceptual model on air sparging topics are discussed. The meaning of radius of influence in the context of air sparging is found to be ambiguous. The hydrodynamic effects of air sparging such as mounding of ground water and flow impedance are explored. Limitations on rates of remediation and operational strategics for improving sparging effectiveness are examined.  相似文献   

14.
An Overview of In Situ Air Sparging   总被引:3,自引:0,他引:3  
In situ air sparging (IAS) is becoming a widely used technology for remediating sites contaminated by volatile organic materials such as petroleum hydrocarbons. Published data indicate that the injection of air into subsurface water saturated areas coupled with soil vapor extraction (SVE) can increase removal rates in comparison to SVE alone for cases where hydrocarbons are distributed within the water saturated zone. However, the technology is still in its infancy and has not been subject to adequate research, nor have adequate monitoring methods been employed or even developed. Consequently, most IAS applications are designed, operated, and monitored based upon the experience of the individual practitioner.
The use of in situ air sparging poses risks not generally associated with most practiced remedial technologies: air injection can enhance the undesirable off-site migration of vapors and ground water contamination plumes. Migration of previously immobile liquid hydrocarbons can also be induced. Thus, there is an added incentive to fully understand this technology prior to application.
This overview of the current state of the practice of air sparging is a review of available published literature, consultation with practitioners, a range of unpublished data reports, as well as theoretical considerations. Potential strengths and weaknesses of the technology are discussed and recommendations for future investigations are given.  相似文献   

15.
Accurate prediction of water and air Iran sport parameters in variably saturated soil is necessary for modeling of soil-vapor extraction (SVE) at soil sites contaminated with volatile organic chemicals (VOCs). An expression for predicting saturated water permeability (kl,s) in undisturbed soils from the soil total porosity and the field capacity soil-water content was developed by fitting a tortuous-tube fluid flow model to measured water permeability and gas diffusivity data. The new kl,s expression gave accurate predictions when tested against independent kl,s data. The kl,s expression was implemented in the Campbell relative water permeability model to yield a predictive model for water permeability in variably saturated, undisturbed soil. The water permeability model, together with recently developed predictive equations for gas permeability and gas diffusivity, was used in a two-dimensional numerical SVE model that also included non-equilibrium mass transfer of VOC from a separate phase (nonaqueous phase liquid [NAPL]) to the air phase. SVE: calculations showed that gas permeability is likely the most important factor controlling VOC migration and vapor extraction efficiency. Water permeability and gas diffusivity effects became significant at water contents near and above field capacity. The NAPL-air mass transfer coefficient also had large impacts on simulated vapor extraction efficiency. The calculations suggest that realistic SVE models need to include predictive expressions for both conveciive, diffusive. and phase-partitioning processes in natural, undisturbed soils.  相似文献   

16.
Air sparging was evaluated for remediation of tetrachloroethylene (PCE) present as dense nonaqueous phase liquid (DNAPL) in aquifers. A two-dimensional laboratory tank with a transparent front wall allowed for visual observation of DNAPL mobilization. A DNAPL zone 50 cm high was created, with a PCE pool accumulating on an aquitard. Detailed process control and analysis yielded accurate mass balances and insight into the mass-transfer limitations during air sparging. Initial PCE recovery rates were high, corresponding to fast removal of residual DNAPL within the zone influenced directly by air channels. The vadose zone DNAPL was removed within a few days, and the recovery in the extracted soil vapors decreased to low values. Increasing the sparge rate and pulsing the air injection led to improved mass recovery, as the pulsing induced water circulation and increased the DNAPL dissolution rate. Dissolved PCE concentrations both within and outside the zone of air channels were affected by the pulsing. Inside the sparge zone, aqueous concentrations decreased rapidly, matching the declining effluent PCE flux. Outside the sparge zone, PCE concentrations increased because highly contaminated water was pushed away from the air injection point. This overall circulation of water may lead to limited spreading of the contaminant, but accelerated the time-weighted average mass removal by 40% to 600%, depending on the aggressiveness of the pulsing. For field applications, pulsing with a daily or diurnal cycling time may increase the average mass removal rate, thus reducing the treatment time and saving in the order of 40% to 80% of the energy cost used to run the blowers. However, air sparging will always fail to remove DNAPL pools located below the sparge point because the air will rise upward from the top of a screen, unless very localized geological layers force the air to migrate horizontally. Unrecognized presence of DNAPL at chlorinated solvent sites residual and pools could potentially hamper success of air sparging cleanups, since the presence of small DNAPL pools, ganglia or droplets can greatly extend the treatment time.  相似文献   

17.
Cleanup standards for volatile organic compounds in thick vadose zones can be based on indirect risk (transport to ground water) when contamination is below depths of significant direct risk. At one Arizona Superfund site, a one-dimensional vadose zone transport model (VLE-ACH) was used to estimate the continued transport of VOCs from the vadose zone to ground water. VLEACH is a relatively simple and readily available model that proved useful for estimating indirect risk from VOCs in the vadose zone at this site. The estimates of total soil concentrations used as initial conditions for VLF.ACH incorporated a variety of data from the site. Soil gas concentrations were found to be more useful than soil matrix data for estimating total soil concentrations at this arid-zone site. A simple mixing cell model was used with the VLEACH-derived mass loading estimates from the vadose zone over time to estimate the resulting changes in ground water concentrations. For this site, the results of the linked VLEACH/mixing cell simulations indicate it is likely that the federal MCI. for TCE will be exceeded in underlying ground water if remedial action on I he vadose zone is not pursued.  相似文献   

18.
Boreholes drilled through contaminated zones in fractured rock create the potential for vertical movement of contaminated ground water between fractures. The usual assumption is that purging eliminates cross contamination; however, the results of a field study conducted in a trichloroethylene (TCE) plume in fractured sandstone with a mean matrix porosity of 13% demonstrates that matrix-diffusion effects can be strong and persistent. A deep borehole was drilled to 110 m below ground surface (mbgs) near a shallow bedrock well containing high TCE concentrations. The borehole was cored continuously to collect closely spaced samples of rock for analysis of TCE concentrations. Geophysical logging and flowmetering were conducted in the open borehole, and a removable multilevel monitoring system was installed to provide hydraulic-head and ground water samples from discrete fracture zones. The borehole was later reamed to complete a well screened from 89 to 100 mbgs; persistent TCE concentrations at this depth ranged from 2100 to 33,000 microg/L. Rock-core analyses, combined with the other types of borehole information, show that nearly all of this deep contamination was due to the lingering effects of the downward flow of dissolved TCE from shallower depths during the few days of open-hole conditions that existed prior to installation of the multilevel system. This study demonstrates that transfer of contaminant mass to the matrix by diffusion can cause severe cross contamination effects in sedimentary rocks, but these effects generally are not identified from information normally obtained in fractured-rock investigations, resulting in potential misinterpretation of site conditions.  相似文献   

19.
本文以实例介绍了用浅层反射波法杂找基岩地下水的地质效果,根据浅震勘察结果,在断层破碎带上布置钻孔,获得了满足需求的水质和水量。  相似文献   

20.
Oxygen probes developed to measure in situ oxygen concentrations in gaseous and aqueous environments were evaluated in laboratory tests and during long-term field evaluation trials at contaminated sites. The oxygen probes were shown to have a linear calibration and to be accurate compared to conventional dissolved oxygen electrodes and gas chromatography, both of which require labor-intensive sample collection and processing. The probes, once calibrated, required no maintenance or recalibration for up to a period of 7 years in low-oxygen environments, demonstrating long-term stability. Times to achieve 90% of the stabilized concentration ( t 90) after a step change in aqueous oxygen concentration were 100–120 min in laboratory experiments and up to 180 min in field experiments, which is adequate for monitoring subsurface changes. Field application data demonstrated that the oxygen probes could monitor oxygen concentrations in hydrocarbon-contaminated ground water to a depth of 20 m below the water table or in pyritic vadose zones over extended periods. During bioremediation field trials, oxygen monitoring enabled estimation of oxygen utilization rates by microorganisms and hydrocarbon biodegradation rates. Also, probes were able to monitor the development of ground water desaturation during air sparging trials, enabling the automated assessment of the distribution of injected air.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号