首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this study we evaluated the capability of a 213 nm laser ablation system coupled to a quadrupole-based ICP-MS in delivering accurate and precise U-Pb ages on zircons and monazites. Four zircon samples ( ca. 50 Ma to ca. 600 Ma) and four monazite samples ( ca. 30 Ma to ca. 1390 Ma) of known ages were analysed utilising laser ablation pits with diameters of 20 μm and 60 μm. Instrument mass bias and laser induced time-dependent elemental fractionation were corrected for by calibration against a matrix-matched reference material. Tera-Wasserburg plots of the calculated U-Pb data were employed to assess, and correct for, common Pb contributions. The results indicated that the LA-ICP-MS technique employed in this study allowed precise and accurate U-Pb isotope dating of zircon and monazite on sample areas 20 μm in diameter. At this spot size, the precisions achieved for single spot 206Pb/238U ages, were better than 5% (2s) for monazites and zircons with ages down to 30 Ma and 50 Ma, respectively. The precisions reported are comparable to those generally reported in SIMS and LA-MC-ICP-MS U-Pb isotope determinations.  相似文献   

2.
张德贤 《岩矿测试》2012,31(1):120-126
微区原位分析提供了固体物质的元素及同位素组成的空间分布信息,有利于解决不同的地质问题、环境问题和工业方面的问题。磁铁矿中微量元素地球化学组成有助于研究成矿时的物理化学条件和示踪新的矿床。本文建立了利用激光剥蚀-电感耦合等离子体质谱(LA-ICP-MS)分析磁铁矿中微量元素的方法,探讨了选择必要的分析元素,选择合适的内标、外标,选择恰当的束斑大小等方法。以LA-ICP-MS分析澳大利亚Ernest Henry IOCG矿床磁铁矿中微量元素的方法为例,采用NIST SRM 610作为外标,Fe作为内标较为合理;正常情况下采用32~60 μm的激光束,但对于个别样品中磁铁矿颗粒较小,可以考虑使用较小的激光束(24 μm或16 μm);为消除质谱干扰,Ti选择测量49Ti,Cu选择测量65Cu,Sn选择测量118Sn。  相似文献   

3.
激光剥蚀-电感耦合等离子体质谱(LA-ICP-MS)技术是目前最常用的锆石U-Pb同位素年龄测定方法之一。该方法能够对单颗粒锆石内部年龄差异实现快速、准确的原位微区分析。文章总结了近年来激光剥蚀系统、ICP-MS技术以及LA-ICP-MS锆石U-Pb定年方法、相关应用实例研究的进展和现状。系统评述了激光发生器,剥蚀池,剥蚀参数(激光波长、脉冲宽度、剥蚀气体、孔径大小)以及四极杆和扇形磁场质谱仪对锆石U-Pb年龄数据的精度和准确度的影响。详细介绍了基于锆石年龄标准样品、标准溶液及其他标样的外标定量校准方法,单个U/Pb比值计算方法,普通铅校正方法以及同位素年龄与微量元素同时测定的方法。目前LA-ICP-MS锆石U-Pb定年技术主要应用于碎屑锆石的沉积物源区示踪和岩浆事件的年代学约束研究。  相似文献   

4.
外标物质及内标元素的选择是激光剥蚀-电感耦合等离子体质谱(LA-ICP-MS)准确测定元素含量的关键因素之一。文章选用玻璃标准参考物质NIST 610、GSE-1G、BHVO-2G、BCR-2G、ATHO-G、KL2-G和T1-G作为外标,Si或Zr作为内标,对锆石M257中的Ti进行LA-ICP-MS微区原位测定。结果显示,选择Si或Zr作内标,采用BCR-2G、ATHO-G、KL2-G和T1-G作外标时,Ti含量测定值与参考值之间差异均较大,因此它们不适合作外标物质。采用BHVO-2G作外标和Si作内标,NIST 610作外标和Zr作内标,Ti含量测定值与参考值之间的差异均小于4%,因此BHVO-2G和NIST 610可有条件地作为外标物质。选择Si还是Zr作内标,GSE-1G作外标时,Ti含量的测定值与参考值之间的差异均小于3%,说明GSE-1G是较为合适的外标物质。选用GSE-1G作为外标,Si作内标,对5个标准锆石中的Ti含量进行了测定,结果显示,Ti元素在锆石91500中分布不均匀,而在锆石GJ-1、M257、PENGLAI和MUDTANK中分布均匀。在Ti元素分布均匀的GJ-1、M257、PENGLAI和MUDTANK等4个锆石中,由于Ti的含量均小于5μg/g,不适合作为锆石中Ti元素测定用的外标物质,但可作为测定时的质量监控样品。  相似文献   

5.
主编絮语     
罗立强 《岩矿测试》2011,30(2):I-II
第一行过渡金属元素及痕量贵金属元素高度富集在硫化物矿物中,常形成具有工业意义的矿床,使得硫化物具有重大的经济价值。对天然硫化物矿物中的这些痕量金属元素丰度及其分布的研究,在矿石成因学、经济地质学、环境地球化学等领域具有重要的应用价值。激光剥蚀-电感耦合等离子体质谱(LA-ICP-MS)微区分析技术是一种强大的痕量元素分析工具,非常适合直接分析硫化物矿物中痕量元素的浓度及其空间分布。由于硫化物的激光剥蚀特性与硅酸盐及氧化物不同,分析校准用的标准物质又极度缺乏,严重阻碍了这一技术在硫化物矿物微区分析中的应用。本文评述了硫化物简介、硫化物中痕量金属元素分析的意义、LA-ICP-MS微区分析技术在硫化物矿物痕量元素分析中的优势及近年来的应用进展、硫化物分析中的干扰与校准、包含铂族元素及金的硫化物标准物质的研制进展及合成硫化物标准物质最有应用前景的方法。  相似文献   

6.
第一行过渡金属元素及痕量贵金属元素高度富集在硫化物矿物中,常形成具有工业意义的矿床,使得硫化物具有重大的经济价值。对天然硫化物矿物中的这些痕量金属元素丰度及其分布的研究,在矿石成因学、经济地质学、环境地球化学等领域具有重要的应用价值。激光剥蚀-电感耦合等离子体质谱(LA-ICP-MS)微区分析技术是一种强大的痕量元素分析工具,非常适合直接分析硫化物矿物中痕量元素的浓度及其空间分布。由于硫化物的激光剥蚀特性与硅酸盐及氧化物不同,分析校准用的标准物质又极度缺乏,严重阻碍了这一技术在硫化物矿物微区分析中的应用。本文评述了硫化物简介、硫化物中痕量金属元素分析的意义、LA-ICP-MS微区分析技术在硫化物矿物痕量元素分析中的优势及近年来的应用进展、硫化物分析中的干扰与校准、包含铂族元素及金的硫化物标准物质的研制进展及合成硫化物标准物质最有应用前景的方法。  相似文献   

7.
罗涛  卿丽媛  刘金雨  张文  何焘  胡兆初 《岩矿测试》2023,42(5):996-1006
碳酸盐中微量元素信息可为探究古环境、古气候演化、壳幔相互作用以及成岩成矿等重要地质作用过程提供关键约束,其微量元素含量的准确测定一直备受学者关注。激光剥蚀电感耦合等离子体质谱(LA-ICP-MS)可提供碳酸盐矿物中微量元素含量的精细信息,而常规激光测试方法严重制约着碳酸盐矿物微量元素分析的空间分辨率和低含量元素的检测能力。相比于常规剥蚀池条件时的低频率分析,本研究通过采用气溶胶局部提取快速清洗剥蚀池结合高频率激光剥蚀的方式,快速提升激光微区分析瞬时信号强度,有效地提升峰形信号灵敏度(约13倍),碳酸盐激光微区元素检出限降低5~10倍。在此激光分析模式下,分别采用纳秒和飞秒激光剥蚀联用四极杆等离子体质谱仪(LA-Q-ICP-MS),以NIST610玻璃为外标,Ca为内标开展了较小激光剥蚀束斑(32μm)条件下碳酸盐矿物中微量元素(亲石元素、亲铁和亲硫元素)分析。结果表明,纳秒和飞秒激光分析碳酸盐矿物标样CGSP-A、CGSP-B、CGSP-C、CGSP-D和MACS-3获得的亲石元素(如Sc、Sr、Y、Ba、La、Ce、Pr、Nd、Sm、Eu、Gd、Tb、Dy、Ho、Er、Tm、Yb和Th等)测试值与推荐值在误差范围内一致;而亲铁和亲硫元素(如Ni、Cu、Zn、As、Cd、Sn、Sb和Pb)测试结果则存在较大偏差(大于20%),这可能与本研究选用的高频激光剥蚀和较小剥蚀束斑(32µm)造成显著的“Downhole”分馏效应有关。本研究通过研制新型激光剥蚀池,改变激光剥蚀方式,即采用气溶胶局部提取剥蚀池和高频率剥蚀方法可有效地提升碳酸盐矿物微量元素(如亲石元素)分析的空间分辨率和低含量元素检测能力,有利于促进碳酸盐矿物在地质环境等领域的广泛应用。  相似文献   

8.
锆石LA-ICP-MS原位微区U-Pb定年及微量元素的同时测定   总被引:7,自引:0,他引:7  
利用配有的 New Wave 213 nm 激光和 ThermoFisher X Series 2四极杆等离子体质谱,对年龄在158~1065 Ma之间的5个标准锆石进行了U-Pb同位素和微量元素的同时测定.测定结果显示,在激光频率为10 Hz,斑束直径为30μm 下,91500、GJ-1、TEMORA-1、Ple?ovice 和 Qinghu 标准锆石所获得的加权平均年龄分别为(1059±11) Ma (2σ, n=21),(604.4±4.7) Ma (2σ, n=25),(419.3±3.4) Ma (2σ, n=14),(338.7±2.4) Ma (2σ, n=23)和(158.9±1.7) Ma (2σ, n=18),年龄分析测定的单点相对偏差(2σ)均小于5.6%,加权平均年龄的相对偏差(2σ)均小于1.08%.5个标准锆石定年结果在误差范围内与前人报道的年龄值完全一致.在相同的测试条件下,以 NIST610为外标,对上述标准锆石的微量元素进行了同时测定, Ple?ovice 除了 Nb比文献给定的值偏高外,其余微量元素和91500微量元素的测定结果都落在文献报道的范围之内, GJ-1中的Pb、Th和U落在TIMS测定值的范围之内, TEMORA-1中的Th和U落在SHRIMP测定的值之内, Qinghu中的Th和U落在SIMS测定的值之内.从5个标准锆石的稀土元素球粒陨石标准化曲线可看出,所获得的稀土元素的相对含量也准确.  相似文献   

9.
Fifty-two trace elements in NIST SRM 614, 616 and MPI-DING BM90/21-G glass reference materials as well as in NIST SRM 612, USGS BCR2-G and other MPI-DING reference glasses (KL2-G, GOR132-G, GOR128-G, ATHO-G, Tl-G, StHs6/80-G and ML3B-G) were determined by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). Accurate ultra-low trace element abundances in the NIST SRM 614, 616 and BM90/21-G reference glasses down to lower ng g−1 levels were determined with relative standard deviations (RSD) of less than 10%. Limits of detection using He as carrier gas were up to two times lower than with Ar and were 0.004 to 0.12 μg g−1 for elements of lower mass numbers (amu < 85) and 0.002 to 0.06 μg g−1 for elements having amu < 85. The measured concentrations generally agree within 15% with previous studies except for B in NIST SRM 614 and 616, which appears to be heterogeneously distributed, and Co, Zn, Ga and Ag in NIST SRM 616 for which the existing data set is too small to evaluate the discrepancies. New values for As (0.593 μg g−1), Ag (0.361 μg g−1) and Cd (0.566 μg g−1) in NIST SRM 614 and new values for Na (94864 μg g−1) and As (0.276 μg g−1) in NIST SRM 616 are reported.  相似文献   

10.
To understand and/or avoid small-scale chemical heterogeneities within geological materials prepared as normal thin sections, in situ multiple trace element determination coupled with the simultaneous microscopic observation of the sample during analysis is preferable. We have examined fifty trace elements in thin (< 30 μm) layers of the NIST SRM 614 and 616 glass reference materials by LA-ICP-MS using different pit diameters and internal standard elements (Ca and Si). Compositional heterogeneities of Tl, Bi, As and Cd were found in NIST SRM 614 and 616 at the spatial resolution of ca. 10 0 μm. Except for these elements, the RSDs of six determinations for most elements were better than 10% in NIST SRM 614 when ablation diameters were < 50 μm. The measured concentrations for most elements in NIST SRM 614 and 616 agree with previous values in the literature at the 95% confidence level with the exception of W and Bi. New LA-ICP-MS data for K, As and Cd are also reported. The results support the view that the latest LA-ICP-MS is a powerful and flexible analytical technique for the determination of multiple ultra-trace element compositions in geological materials prepared as normal thin sections of the type that has been used for polarising optical microscopic observations since the end of the 19th century.  相似文献   

11.
Forty two major (Na, Mg, Ti and Mn) and trace elements covering the mass range from Li to U in three USGS basalt glass reference materials BCR‐2G, BHVO‐2G and BIR‐1G were determined using laser ablation‐inductively coupled plasma‐mass spectrometry. Calibration was performed using NIST SRM 610 in conjunction with internal standardisation using Ca. Determinations were also made on NIST SRM 612 and 614 as well as NIST SRM 610 as unknown samples, and included forty five major (Al and Na) and trace elements. Relative standard deviation (RSD) of determinations was below 10% for most elements in all the glasses under investigation. Consistent exceptions were Sn and Sb in BCR‐2G, BHVO‐2G and BIR‐1G. For BCR‐2G, BHVO‐2G and BIR‐1G, clear negative correlations on a logarithmic scale exist between RSD and concentration for elements lower than 1500 μg g‐1 with logarithmic correlation coefficients between ‐0.75 and ‐0.86. There is also a clear trend of increasing RSD with decreasing concentration from NIST SRM 610 through SRM 612 to SRM 614. These suggest that the difference in the scatter of apparent element concentrations is not due to chemical heterogeneity but reflects analytical uncertainty. It is concluded that all these glasses are, overall, homogeneous on a scale of 60 μm. Our first results on BHVO‐2G and BIR‐1G showed that they generally agreed with BHVO‐2/BHVO‐1 and BIR‐1 within 10% relative. Exceptions were Nb, Ta and Pb in BHVO‐2G, which were 14‐45% lower than reference values for BHVO‐2 and BHVO‐1. Be, Ni, Zn, Y, Zr, Nb, Sn, Sb, Gd, Tb, Er, Pb and U in BIR‐1G were also exceptions. However, of these elements, Be, Nb, Sn, Sb, Gd, Tb, Pb and U gave results that were consistent within an uncertainty of 2s between our data and BIR‐1 reference values. Results on NIST SRM 612 agreed well with published data, except for Mg and Sn. This was also true for elements with m/z 85 (Rb) in the case of NIST SRM 614. The good agreement between measured and reference values for Na and Mg in BCR‐2G, BHVO‐2G and BIR‐1G, and for Al and Na in NIST SRM 610, 612 and 614 up to concentrations of at least several weight percent (which were possible to analyse due to the dynamic range of 108) indicates the suitability of this technique for major, minor and trace element determinations.  相似文献   

12.
同位素地质年代学是探索地质体时空演化及地球动力学等问题的基础学科,应用最为广泛的当属含铀副矿物的U-Pb定年技术。榍石具有相对较低的U-Pb体系封闭温度,并广泛发育于岩浆岩、各类变质岩、热液成因岩石以及少量沉积岩中,是一种理想的中高温地质事件定年矿物。利用电感耦合等离子体质谱法(ICP-MS)测定榍石U-Pb年龄时,不可避免地要解决高普通铅以及元素分馏效应对测试的影响。本文对榍石LA-ICP-MS实验过程中的元素分馏行为进行研究,采用相同基体的标准样品与未知样品对比,发现了榍石不同颗粒之间元素分馏行为不一致的现象;同时采用不同的元素分馏校正方法,分别应用于锆石、独居石和榍石进行对比研究,认为分馏行为一致的副矿物定年可以采用"指数法"和"均值法"对数据进行校正,但是对于榍石这种分馏行为不一致的副矿物,定年时只有采用"截距法"对数据进行校正才可以获得正确的年龄。进而将此结论应用于秦岭造山带老牛山地区岩浆成因榍石样品,得到的结果与锆石年龄一致,表明"截距法"可以避免分馏行为不一致导致的校正不准确的问题。本研究成果为榍石LA-ICP-MS U-Pb定年方法的完善提供了一种思路。  相似文献   

13.
石笋样品的微量元素含量及Mg/Ca、Sr/Ca比值为高分辨的古气候重建提供重要指标。针对现有溶液分析技术易混合多个石笋微层、误差大的缺点,本文利用激光剥蚀电感耦合等离子体质谱技术(LA-ICP-MS)原位线扫描和点剥蚀方式对比分析了石笋生长轴方向的Mg/Ca和Sr/Ca空间分布趋势,研究表明二者均展现出显著的周期性变化特征,且周期性变化一致,其中40 μm束斑线扫描更具有稳定性强、分辨率高、快速简便的优点。通过探讨碳酸盐标准样品MASC-3与玻璃标准样品NIST 610、NIST 612、KL2G、ATHO-G的相对灵敏度系数关系和元素分馏行为,确定基体效应是造成相对灵敏度系数变化的主要原因。同时建立了以MASC-3、NIST 610和NIST 612多外标结合内标Ca归一定量分析石笋中45种元素方法,针对石笋碳酸盐样品,将主量元素Ca、Mg变形为碳酸盐形式,与其他元素加和归一,不仅改变了国内外研究中需要预先采用其他分析技术来测定内标元素含量的计算方法,而且有效地避免了C元素无法准确检测的问题,能够实现与Ca内标法校正结果的吻合。  相似文献   

14.
通过激光剥蚀电感耦合等离子体质谱(LA-ICP-MS)获得被测物相中痕量元素的丰度值是目前原位分析矿物物相的技术之一。黄铁矿作为斑岩铜矿中的重要矿物,其主量、微量元素的特征能为成矿过程提供重要信息。本文建立了应用LA-ICP-MS测定黄铁矿微区微量元素组成、电子探针(EMPA)测定主量元素的方法,并将该方法应用到白山堂斑岩铜矿区。LA-ICP-MS实验采用60 μm的激光束对分析样品进行斑点式剥蚀,以氦气作载气,重复频率5 Hz,激光能量约6 J/cm2;单点分析时间60 s,分析数据以Fe作内标,用MASS-1黄铁矿标样进行校正,多数元素分析精度好于10%。针对黄铁矿与毒砂光学性质相似,容易混淆的问题,可以利用二者物理性质的差异进行区分。测试结果显示:矿区黄铁矿的主量元素呈亏硫高铁的特征,指示其为热液成因;微量元素特征表明其形成深度为中部,属与火山作用有关的中低温热液型黄铁矿。此结论对白山堂铜矿的成因类型、成矿流体来源等提供了相应的证据,对矿区的勘查具有理论指导意义。  相似文献   

15.
激光剥蚀-等离子体质谱(LA-ICPMS)已成为地球化学、宇宙化学和环境研究领域元素和同位素原位分析最重要的技术之一。文章介绍了多种类型的质谱仪及其使用的激光器。用途最广的LA-ICPMS仪器之一是单接收器扇形磁场质谱仪,配有Nd:YAG激光剥蚀系统(激光波长分为193 nm和213 nm两种),MPI Mainz实验室使用的就是这套系统,文章对此作一详细介绍。文中阐述了数据优化技术及其多种校正过程;介绍LA-ICPMS在痕量元素和同位素分析领域的一些应用,包括参考物质的研制,Hawaiian玄武岩、Martian陨石、生物骨针和珊瑚虫中痕量元素分析及熔融包裹体和富钙-铝碳质球粒陨石中的铅和锶同位素测量。  相似文献   

16.
Microscopic melt inclusions found in magmatic minerals are undoubtedly one of the most important sources of information on the chemical composition of melts. This paper reports on the successful application of near-infrared (NIR) femtosecond laser ablation (LA) - inductively coupled plasma-mass spectrometry to in situ determination of incompatible trace elements (Li, Rb, Sr, Y, Zr, Nb, Cs, Ba, REE, Ta, Th, U) and ore metals (As, Mo, Pb) in individual melt inclusions hosted in quartz from the Mount Pinatubo dacites, Philippines. The determined elements cover a concentration range of five orders of magnitude. Femtosecond LA-ICP-MS analyses of twenty-eight individual melt inclusions demonstrate the efficiency of the microanalytical technique and suggests a spectacular homogeneity of the entrapped melt, at least with respect to the following incompatible trace elements: Rb, Sr, Nb, Cs, Ba, La, Ce, Pr, Nd, Pb, Th. The analytical precision (1s) for Na, Ca, Rb, Sr, Y, Nb, Ba and LREE ranged from 3 to 20%. Comparison of trace element concentrations in Mt. Pinatubo melt inclusions determined by femtosecond LA-ICP-MS with those of melt inclusions previously analysed by secondary ion mass spectrometry analysis (SIMS) and those of matrix glasses previously determined by nanosecond LA-ICP-MS showed an agreement typically within 30–40%. The homogeneity of trace element concentrations of the Mt. Pinatubo melt inclusions and the matrix glasses is consistent with the melt inclusion origin as homogeneous rhyolitic melt that was trapped in quartz phenocrysts at the final crystallisation stages of the host adakite (dacite) magma.  相似文献   

17.
近年来全岩电感耦合等离子体质谱(ICP-MS)和原位激光剥蚀电感耦合等离子体质谱(LA-ICP-MS)微量元素地球化学测试在地球科学领域的应用越来越广泛。霓长岩化是碳酸岩型稀土矿常见的蚀变类型,但其中的蚀变矿物微量元素特征与稀土矿化关系并不清楚。本文对川西牦牛坪矿床两期霓长岩化脉(无矿脉和含矿脉)中的霓辉石、钠铁闪石同时开展ICP-MS和LA-ICP-MS微量元素测试。结果表明:同期次的霓长岩化脉中,霓辉石、钠铁闪石全岩ΣREE含量远高于单矿物原位ΣREE含量,背散射图像显示霓辉石、钠铁闪石矿物中叠加了一些氟碳铈矿、重晶石微矿物。不同期次霓长岩化脉中霓辉石原位微量对比,含矿脉中的霓辉石具有更高的La/Nd值(0.19~0.23)、LREE/HREE值(6.58~7.79)、Ce/Nd值(0.95~1.11)、LaN/YbN值(2.07~2.33)。对比全岩微量组成,含矿脉中高含量的La、Ce、LREE、ΣREE,强烈的轻重稀土分异,可能代表了高稀土通量的霓长岩化流体。霓长岩化脉的出现以及脉体中霓辉石、钠铁闪石这些全岩微量、原位微量地球化学指标,可为碳酸岩型稀土矿床找矿勘查提供参考。  相似文献   

18.
朱碧  朱志勇  吕苗  杨涛 《岩矿测试》2017,36(1):14-21
LA-ICP-MS分析技术是获取矿物/岩石内部的元素和同位素成分变化的重要手段。在利用该技术对地质样品进行线/面扫描时,仪器输出的初始数据量远远大于点分析,数据的处理和计算是一个关键问题。本文以磷质结核样品为例,阐述了利用Iolite软件进行元素线扫描数据计算的主要过程,包括背景信号的扣除、标准物质信号的拟合、线分析数据的导出等。借助软件自带的分段导出功能,对不同时间和空间分辨率下采集数据得到的结果进行了比较。研究表明Iolite能有效处理线分析数据,分析结果与前人用传统化学全岩法测定得到的元素含量范围相当。对比不同空间分辨率下(10μm、50μm、100μm)获取的数据发现:相对于选用的束斑直径(40μm),在分辨率过小(10μm)或过大(100μm)的条件下获得的数据存在数据波动大以及细节不足等缺陷;而当分辨率(50μm)与选用的束斑直径接近时,数据质量得到最大优化。本研究展示了Iolite软件在处理线扫描数据方面具有很好的应用前景,通过分辨率的选取可实现数据的优化。  相似文献   

19.
激光剥蚀-电感耦合等离子体质谱(LA-ICP-MS)作为一项实用的技术被广泛应用于原位微区分析。在学者们更为关注的元素空间分布问题上,LA-ICP-MS线扫描较单点剥蚀具有更大的优势。线扫描过程中元素的空间分辨率是影响分析结果准确程度的因素之一。每个脉冲间的信号如果严重叠加会导致较低的空间分辨率。文章通过LA-ICP-MS的单脉冲剥蚀实验,研究了合成硅酸盐玻璃标准样品CGSG中不同元素的信号时间结构,及其对线扫描的空间分辨率的影响。结果表明,当激光束斑40 μm时,应用LA-ICP-MS进行线扫描测量空间分辨率能够满足线扫描技术分析的需求。  相似文献   

20.
本文对采自云南哀牢山构造带西侧、思茅陆块东缘二叠纪末的四个砂岩样品中的碎屑锆石进行了LA-ICP-MS U-Pb年龄和微量元素测试,所有样品的年龄谱都显示出250~290 Ma的显著特征峰, XD37、XD40还得到900~1000 Ma的主特征峰和400~600 Ma的次特征峰;另外两个样品XD41和XD50也具有400~600 Ma和900~1000 Ma的特征峰,但是锆石数量较少。绝大部分的碎屑锆石微量元素都指示其源岩来自岩浆弧/造山带构造环境。结合前人研究成果,我们认为这些砂岩沉积于一个靠近思茅陆块边缘的弧后盆地,该弧后盆地可能是哀牢山洋二叠纪自东向西俯冲消减而产生。  相似文献   