首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Streambed hydraulic conductivity is one of the main factors controlling variability in surface water‐groundwater interactions, but only few studies aim at quantifying its spatial and temporal variability in different stream morphologies. Streambed horizontal hydraulic conductivities (Kh) were therefore determined from in‐stream slug tests, vertical hydraulic conductivities (Kv) were calculated with in‐stream permeameter tests and hydraulic heads were measured to obtain vertical head gradients at eight transects, each comprising five test locations, in a groundwater‐dominated stream. Seasonal small‐scale measurements were taken in December 2011 and August 2012, both in a straight stream channel with homogeneous elevation and downstream of a channel meander with heterogeneous elevation. All streambed attributes showed large spatial variability. Kh values were the highest at the depositional inner bend of the stream, whereas high Kv values were observed at the erosional outer bend and near the middle of the channel. Calculated Kv values were related to the thickness of the organic streambed sediment layer and also showed higher temporal variability than Kh because of sedimentation and scouring processes affecting the upper layers of the streambed. Test locations at the channel bend showed a more heterogeneous distribution of streambed properties than test locations in the straight channel, whereas within the channel bend, higher spatial variability in streambed attributes was observed across the stream than along the stream channel. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
Accurate estimation of streambed vertical hydraulic conductivity (Kv) is of great importance in the analysis of water quantity exchange and solute transfer between a stream and its sediments. The paper analyzed the inaccuracy of hydraulic conductivity values of sediments derived from grain-size distribution (Kg), which were determined from eight empirical grain-size methods to represent streambed Kv. In this study, the values of Kv for a streambed were derived using falling-head standpipe permeameter tests conducted at eight study sites in the Elkhorn River, Nebraska, and the tested streambed columns were then collected for grain-size analysis by sieving. These empirical methods were used to calculate the Kg values of the streambed from grain-size distribution data of sediments. Unlike many other studies, this study verifies Kg from grain-size distribution with Kv from permeameter tests on the basis of the same samples of streambed sediments. The Kg values derived from the eight empirical methods were larger than the Kv from permeameter tests; there are five methods that give Kg values of about 3–6 times larger than these Kv. The Kg values from the Kozeny formula followed by the Hazen formula give the largest overestimation error if they are used to represent the Kv of the streambed. The USBR and Shepherd formulas generated Kg values close to Kv, but these Kg values are still larger in general than the Kv values. Moreover, the new values of coefficient C for the empirical formulas were revised so that they can be used to calculate the approximate Kv of a streambed. Among the eight methods, the ratios of the original C values to the average new C range from 1.3 to 5.9. It can be hypothesized that smaller C values must be used in the estimation of Kv for general soil samples if these empirical formulas are used to calculate Kv.  相似文献   

3.
Streambed horizontal hydraulic conductivity (Kh) has a substantial role in controlling exchanges between stream water and groundwater. We propose a new approach for determining Kh of the shallow streambed sediments. Undisturbed sediment samples were collected using tubes that were horizontally driven into streambeds. The sediment columns were analysed using a permeameter test (PT) on site. This new test approach minimizes uncertainties due to vertical flow in the vicinity of test tube and stream stage fluctuations in the computation of the Kh values. Ninety‐eight PTs using the new approach were conducted at eight sites in four tributaries of the Platte River, east‐central Nebraska, USA. The Kh values were compared with the nondirectional hydraulic conductivity values (Kg) determined from 12 empirical grain‐size analysis methods. The grain‐size analysis methods used the same sediment samples as Kh tests. Only two methods, the Terzaghi and Shepherd methods, yielded Kg values close to the Kh values. Although the Sauerbrei method produced a value relatively closer to Kh than other nine grain‐size analysis methods, the values from this method were not as reliable as the methods of Terzaghi and Shepherd due to the inconsistent fluctuation of the average estimates at each of the test sites. The Zunker, Zamarin, Hazen, Beyer, and Kozeny methods overestimated Kh, while the Slichter, US Bureau of Reclamation (USBR), Harleman, and Alyamani and Sen methods underestimated Kh. Any of these specific grain‐size methods might yield good estimates of streambed Kh at some sites, but give poor estimates at other sites, indicating that the relationship between Kg and Kh is significantly site dependent in our study. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
Streambed hydraulic conductivity (K) and vertical K (K v) are key controls on groundwater and surface water exchange and biogeochemical fluxes through the hyporheic zone, but drivers of transient hydraulic properties in different fluvial environments are poorly understood. This study combines hydrogeology, geophysics, and sedimentology to reveal mechanisms of K and K v transience in the upper 0.5 m of a sandy streambed during low discharge. Hydraulic tests (44 slug tests, 130 falling-head permeameter tests) and 130 grain-size analyses were repeated three times over 8 weeks on a 1,200 m2 grid spanning: (a) a channel with continuously flowing water and mobile bed load; (b) an adjacent mid-channel bar that was stationary and infrequently submerged. Aerial photographs and ground-penetrating radar show scour and complete reworking of fluvial sediments in the channel. Bar sediments below the water table remained immobile, but infrequent flows of moderate discharge reworked the uppermost few centimetres of the bar top. Despite differences in sediment mobility and stream flow characteristics across environments, K and K v exhibited order-of-magnitude differences in spatial heterogeneity and temporal variability in both the channel and bar. Mean K and K v values in the channel were comparatively stable over time. In the immobile bar, mean K declined 20% and K v declined 26% after increased discharge temporarily inundated the bar. Grain-size distributions were steady across both environments over time, but repeat geophysical surveys of the bar show a decrease in electrical conductivity, likely from porosity reduction. These findings suggest that sediment dynamics and stream flow characteristics in different streambed environments are important drivers of K transience during low discharge conditions. Specifically, pore clogging can be an important mechanism of transience over short durations (weeks to months) in immobile sediments subject to infrequent flows and minor reworking.  相似文献   

5.
We present transient streaming potential data collected during falling‐head permeameter tests performed on samples of two sands with different physical and chemical properties. The objective of the work is to estimate hydraulic conductivity (K) and the electrokinetic coupling coefficient (Cl) of the sand samples. A semi‐empirical model based on the falling‐head permeameter flow model and electrokinetic coupling is used to analyze the streaming potential data and to estimate K and Cl. The values of K estimated from head data are used to validate the streaming potential method. Estimates of K from streaming potential data closely match those obtained from the associated head data, with less than 10% deviation. The electrokinetic coupling coefficient was estimated from streaming potential vs. (1) time and (2) head data for both sands. The results indicate that, within limits of experimental error, the values of Cl estimated by the two methods are essentially the same. The results of this work demonstrate that a temporal record of the streaming potential response in falling‐head permeameter tests can be used to estimate both K and Cl. They further indicate the potential for using transient streaming potential data as a proxy for hydraulic head in hydrogeology applications.  相似文献   

6.
The constant‐head permeameter test (CHPT) is widely used in sandy samples as a standard method in the laboratory to investigate hydraulic conductivity (K). However, it neither can be used to consistently determine directional hydraulic conductivity (DHC) nor guarantee the comparability of measured K values of samples with different sizes. Therefore, this paper proposes an integrated laboratory method, called modified CHPT (MCHPT), for the efficient determination and verification of consistent DHC values in fine‐to‐medium sandy sediments, based on a new methodological framework. A precise and standardized procedure for preparing the experimental setup of MCHPT was conducted, based on the integrated experimental setup of CHPT and tracer tests. Moreover, a formula was yielded for the time‐optimized sample saturation control. In comparison with grain size‐based methods, the validity of consistent Kh and Kv values determined by MCHPT was convincing.  相似文献   

7.
River confluences and their associated tributaries are key morphodynamic nodes that play important roles in controlling hydraulic geometry and hyporheic water exchange in fluvial networks. However, the existing knowledge regarding hyporheic water exchange associated with river confluence morphology is relatively scarce. On January 14 and 15, 2016, the general hydraulic and morphological characteristics of the confluent meander bend (CMB) between the Juehe River and the Haohe River in the southern region of Xi'an City, Shaanxi Province, China, were investigated. The patterns and magnitudes of vertical hyporheic water exchange (VHWE) were estimated based on a one‐dimensional heat steady‐state model, whereas the sediment vertical hydraulic conductivity (Kv) was calculated via in situ permeameter tests. The results demonstrated that 6 hydrodynamic zones and their extensions were observed at the CMB during the test period. These zones were likely controlled by the obtuse junction angle and low momentum flux ratio, influencing the sediment grain size distribution of the CMB. The VHWE patterns at the test site during the test period mostly showed upwelling flow dominated by regional groundwater discharging into the river. The occurrence of longitudinal downwelling and upwelling patterns along the meander bend at the CMB was likely subjected to the comprehensive influences of the local sinuosity of the meander bend and regional groundwater discharge and finally formed regional and local flow paths. Additionally, in dominated upwelling areas, the change in VHWE magnitudes was nearly consistent with that in Kv values, and higher values of both variables generally occurred in erosional zones near the thalweg paths of the CMB, which were mostly made up of sand and gravel. This was potentially caused by the erosional and depositional processes subjected to confluence morphology. Furthermore, lower Kv values observed in downwelling areas at the CMB were attributed to sediment clogging caused by local downwelling flow. The confluence morphology and sediment Kv are thus likely the driving factors that cause local variations in the VHWE of fluvial systems.  相似文献   

8.
The vertical hydraulic conductivity (Kv) of a stream or lake sediment is often determined in the field using standpipe tests. Calculation of Kv is based on the assumption that the hydraulic head in the pipe is equal to that of the stream or lake stage. In this work, a modified equation for Kv is developed for the standpipe test which is applicable when this assumption is not valid. The equation involves not only the hydraulic head at different times but also the difference in the hydraulic head (a) between the groundwater level and river stage. The effects of certain factors on Kv, such as the ratio of the hydraulic head at different times (h1/h2), the difference a, and the initial water table height (h0), are also discussed. The results show that when h1/h2 is constant, the relative error (Er) in Kv increases with the ratio a/h2. Furthermore, if a/h2 < 0.05, then for any value of h1/h2, Er is less than 5% using the modified equation. Also, if a/h2 is large, hydraulic head readings with larger h1/h2 ratios must be used to avoid large Er values. The results of a field test also indicate that the error in Kv decreases as the value of h0 increases. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
This study investigated the influence of the regional flow on the streambed vertical hydraulic conductivity (Kv) within the hyporheic zone in three stream reaches of the Weihe River in July 2016. The streambed Kv with two connected depths was investigated at each test reach. Based on the sediment characteristics, the three test reaches could be divided into three categories: a sandy streambed without continuous silt and clay layer, a sandy streambed with continuous silt and clay layer, and a silt–clay streambed. The results demonstrate that the streambed Kv mainly decreases with the depth at the sandy streambed (without continuous silt and clay layer) and increases with the depth at the other two test reaches. At the sandy streambed (with continuous silt and clay layer) where streambed Kv mainly decreases with the depth, the regional upward flux can suspend fine particles and enhance the pore spacing, resulting in the elevated Kv in the upper sediment layers. At another sandy streambed, the continuous silt and clay layer is the main factor that influences the vertical distribution of fine particles and streambed Kv. An increase in streambed Kv with the depth at the silt/clay streambed is attributed to the regional downward movement of water within the sediments that may lead to more fine particles deposited in the pores in the upper sediment layers. The streambed Kv is very close to the bank in the sandy streambed without continuous silt and clay layer and the channel centre in the other two test reaches. Differences in grain size distribution of the sediments at each test reach exercise a strong controlling influence on the streambed Kv. This study promotes the understanding of dynamics influencing the interactions between groundwater and surface water and provides guidelines to scientific water resources management for rivers.  相似文献   

10.
Anisotropy and heterogeneity of hydraulic conductivity (K) are suspected of greatly affecting rates and patterns of ground‐water seepage in peats. A new laboratory method, termed here the modified cube method, was used to measure horizontal and vertical hydraulic conductivity (Kh and Kv) of 400 samples of bog peat. The new method avoids many of the problems associated with existing field and laboratory methods, and is shown to give relatively precise measurements of K. In the majority of samples tested, Kh was much greater than Kv, indicating that the bog peat was strongly anisotropic. Log10Kh, log10Kv, and log10 (Kh/Kv) were found to vary significantly with depth, although none of the relationships was simple. We comment on the scale dependency of our measurements. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

11.
It has long been understood that streambed hydraulic conductivity plays an important role in surface-subsurface solute exchange. Using a portable falling head permeameter in situ, we estimated the horizontal hydraulic conductivity, K, of the near-surface streambed sediments at a total of 85 locations encompassing two depth intervals: 7.5–10 and 10–12.5 cm. The measurements were conducted in an 80 m reach of Indian Creek, a small urban stream in Philadelphia, PA, USA. We found that the ln K data within each sediment layer were Gaussian, but the combined data set was not. The results indicated that while the mean hydraulic conductivity decreased with depth, horizontal heterogeneity (e.g. the variance) increased with depth. This strong contrast between layers suggests that they should be treated as separated entities in modeling studies. Variogram analyses across the stream suggested symmetry with respect to the thalweg in the upper layer and fractality in the lower layer. The variograms along the streams suggested that the K data are random.  相似文献   

12.
Xunhong Chen 《水文研究》2011,25(2):278-287
Characterization of streambed hydraulic conductivity from the channel surface to a great depth below the channel surface can provide needed information for the determination of stream‐aquifer hydrologic connectedness, and it is also important to river restoration. However, knowledge on the streambed hydraulic conductivity for sediments 1 m below the channel surface is scarce. This study describes a method that was used to determine the distribution patterns of streambed hydraulic conductivity for sediments from channel surface to a depth of 15 m below. The method includes Geoprobe's direct‐push techniques and Permeameter tests. Direct‐push techniques were used to generate the electrical conductivity (EC) logs and to collect sequences of continuous sediment cores from river channels, as well as from the alluvial aquifer connected to the river. Permeameter tests on these sediment cores give the profiles of vertical hydraulic conductivity (Kv) of the channel sediments and the aquifer materials. This method was applied to produce Kv profiles for a streambed and an alluvial aquifer in the Platte River Valley of Nebraska, USA. Comparison and statistical analysis of the Kv profiles from the river channel and from the proximate alluvial aquifer indicates a special pattern of Kv in the channel sediments. This depth‐dependent pattern of Kv distribution for the channel sediments is considered to be produced by hyporheic processes. This Kv‐distribution pattern implied that the effect of hyporheic processes on streambed hydraulic conductivity can reach the sediments about 9 m below the channel surface. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
The vertical hydraulic conductivity (Kv), elastic (Sske), and inelastic (Sskv) skeletal specific storage of aquitards are three of the most critical parameters in land subsidence investigations. Two new analytic methods are proposed to estimate the three parameters. The first analytic method is based on a new concept of delay time ratio for estimating Kv and Sske of an aquitard subject to long‐term stable, cyclic hydraulic head changes at boundaries. The second analytic method estimates the Sskv of the aquitard subject to linearly declining hydraulic heads at boundaries. Both methods are based on analytical solutions for flow within the aquitard, and they are jointly employed to obtain the three parameter estimates. This joint analytic method is applied to estimate the Kv, Sske, and Sskv of a 34.54‐m thick aquitard for which the deformation progress has been recorded by an extensometer located in Shanghai, China. The estimated results are then calibrated by PEST (Doherty 2005), a parameter estimation code coupled with a one‐dimensional aquitard‐drainage model. The Kv and Sske estimated by the joint analytic method are quite close to those estimated via inverse modeling and performed much better in simulating elastic deformation than the estimates obtained from the stress‐strain diagram method of Ye and Xue (2005). The newly proposed joint analytic method is an effective tool that provides reasonable initial values for calibrating land subsidence models.  相似文献   

14.
Significant efforts have been expended for improved characterization of hydraulic conductivity (K) and specific storage (Ss) to better understand groundwater flow and contaminant transport processes. Conventional methods including grain size analyses (GSA), permeameter, slug, and pumping tests have been utilized extensively, while Direct Push-based Hydraulic Profiling Tool (HPT) surveys have been developed to obtain high-resolution K estimates. Moreover, inverse modeling approaches based on geology-based zonations, and highly parameterized Hydraulic Tomography (HT) have also been advanced to map spatial variations of K and Ss between and beyond boreholes. While different methods are available, it is unclear which one yields K estimates that are most useful for high resolution predictions of groundwater flow. Therefore, the main objective of this study is to evaluate various K estimates at a highly heterogeneous field site obtained with three categories of characterization techniques including: (1) conventional methods (GSA, permeameter, and slug tests); (2) HPT surveys; and (3) inverse modeling based on geology-based zonations and highly parameterized approaches. The performance of each approach is first qualitatively analyzed by comparing K estimates to site geology. Then, steady-state and transient groundwater flow models are employed to quantitatively assess various K estimates by simulating pumping tests not used for parameter estimation. Results reveal that inverse modeling approaches yield the best drawdown predictions under both steady and transient conditions. In contrast, conventional methods and HPT surveys yield biased predictions. Based on our research, it appears that inverse modeling and data fusion are necessary steps in predicting accurate groundwater flow behavior.  相似文献   

15.
Over the past several decades, different groundwater modeling approaches of various complexities and data use have been developed. A recently developed approach for mapping hydraulic conductivity (K) and specific storage (Ss) heterogeneity is hydraulic tomography, the performance of which has not been compared to other more “traditional” methods that have been utilized over the past several decades. In this study, we compare seven methods of modeling heterogeneity which are (1) kriging, (2) effective parameter models, (3) transition probability/Markov Chain geostatistics models, (4) geological models, (5) stochastic inverse models conditioned to local K data, (6) hydraulic tomography, and (7) hydraulic tomography conditioned to local K data using data collected in five boreholes at a field site on the University of Waterloo (UW) campus, in Waterloo, Ontario, Canada. The performance of each heterogeneity model is first assessed during model calibration. In particular, the correspondence between simulated and observed drawdowns is assessed using the mean absolute error norm, (L1), mean square error norm (L2), and correlation coefficient (R) as well as through scatterplots. We also assess the various models on their ability to predict drawdown data not used in the calibration effort from nine pumping tests. Results reveal that hydraulic tomography is best able to reproduce these tests in terms of the smallest discrepancy and highest correlation between simulated and observed drawdowns. However, conditioning of hydraulic tomography results with permeameter K data caused a slight deterioration in accuracy of drawdown predictions which suggests that data integration may need to be conducted carefully.  相似文献   

16.
Glacial aquifers are an important source of groundwater in the United States and require accurate characterization to make informed management decisions. One parameter that is crucial for understanding the movement of groundwater is hydraulic conductivity, K. Nuclear magnetic resonance (NMR) logging measures the NMR response associated with the water in geological materials. By utilizing an external magnetic field to manipulate the nuclear spins associated with 1H, the time-varying decay of the nuclear magnetization is measured. This logging method could provide an effective way to estimate K at submeter vertical resolution, but the models that relate NMR measurements to K require calibration. At two field sites in a glacial aquifer in central Wisconsin, we collected a total of four NMR logs and obtained measurements of K in their immediate vicinity with a direct-push permeameter (DPP). Using a bootstrap algorithm to calibrate the Schlumberger-Doll Research (SDR) NMR-K model, we estimated K to within a factor of 5 of the DPP measurements. The lowest levels of accuracy occurred in the lower-K (K < 10−4 m/s) intervals. We also evaluated the applicability of prior SDR model calibrations. We found the NMR calibration parameters varied with K, suggesting the SDR model does not incorporate all the properties of the pore space that control K. Thus, the expected range of K in an aquifer may need to be considered during calibration of NMR-K models. This study is the first step toward establishing NMR logging as an effective method for estimating K in glacial aquifers.  相似文献   

17.
The characterization of heterogeneity in hydraulic conductivity (K) is a major challenge for subsurface remediation projects. There are a number of field studies that compare the K estimates obtained using various techniques, but to our knowledge, no field‐based studies exists that compare the performance of estimated K heterogeneity fields or the associated characterization costs. In this paper, we compare the costs of characterizing the three‐dimensional K heterogeneity and its uncertainty estimates of a glaciofluvial aquifer‐aquitard sequence at a 15 m × 15 m × 18 m field site situated on the University of Waterloo campus. We compare geostatistical analysis of high resolution permeameter K data obtained from repacked core samples in five boreholes and hydraulic tomography analysis of four pumping tests consisting of up to 41 monitoring points per test. Aside from the comparison of costs, we also assess the performance of each method by predicting several pumping tests. Our analysis reveals that hydraulic tomography is somewhat more costly than the geostatistical analysis of high resolution permeameter K data due to the higher capital costs associated with the method. However, the equipment may be reused at other sites; hence these costs may be recovered over the life of the equipment. More significantly, hydraulic tomography is able to capture the most important features of the aquifer‐aquitard sequence leading to more accurate predictions of independent pumping tests. This suggests that more robust remediation systems may be designed if site characterization is performed with hydraulic tomography.  相似文献   

18.
The saturated hydraulic conductivity, Ks, is a soil property that has a key role in the partitioning of rainfall into surface runoff and infiltration. The commonly used instruments and methods for in situ measurements of Ks have frequently provided conflicting results. Comparison of Ks estimates obtained by three classical devices—namely, the double ring infiltrometer (DRI), the Guelph version of the constant‐head well permeameter (GUELPH‐CHP) and the CSIRO version of the tension permeameter (CSIRO‐TP) is presented. A distinguishing feature in this study is the use of steady deep flow rates, obtained from controlled rainfall–runoff experiments, as benchmark values of Ks at local and field‐plot scales, thereby enabling an assessment of these methods in reliably reproducing repeatable values and in their capability of determining plot‐scale variation of Ks. We find that the DRI grossly overestimates Ks, the GUELPH‐CHP gives conflicting estimates of Ks with substantial overestimation in laboratory experiments and underestimation at the plot scale, whereas the CSIRO‐TP yields average Ks values with significant errors of 24% in the plot scale experiment and 66% in laboratory experiments. Although the DRI would likely yield a better estimate of the nature of variability than the GUELPH‐CHP and CSIRO‐TP, a separate calibration may be warranted to correct for the overestimation of Ks values. The reasons for such discrepancies within and between the measurement methods are not yet fully understood and serve as motivation for future work to better characterize the uncertainty associated with individual measurements of Ks using these methods and the characterization of field scale variability from multiple local measurements.  相似文献   

19.
Denitrification is studied in sediments from two areas of the River Butrón which represent different situations with respect to their degree of pollution. Denitrification is analysed by means of the following parameters: maximum denitrification rate (Vmax), Michaelis constant (Km), denitrification rate (v), denitrification constant (kd) and number of denitrifiers. In all the samples analysed denitrification follows a kinetic type Michaelis-Menten with respect to nitrate. Vmax, Km and number of denitrifiers are clearly superior in the polluted area when compared to the cleaner area, indicating an advantage given that denitrification suggests an alternative pathway for breaking down organic matter with low levels of dissolved oxygen. By comparison between Km and natural nitrate concentration values we find that v follows a first order kinetic depending directly on the nitrate concentration. v also presents higher values in the area of the river where the entry of sewage is taking place than in the cleaner area. However, this difference does not have a kinetic origin but rather is given by different nitrate concentrations in their sediments. This is due to the fact that the two areas present similar efficiencies in the elimination of nitrate, which is deduced from the similar values of kd.  相似文献   

20.
This article presents the results of a field investigation of saturated hydraulic conductivity Ksat and bulk density (ρbd) in an Atlantic blanket bog in the southwest of Ireland. Starting at a peatland stream and moving along an uphill transect toward the peatland interior, ρbd and Ksat were examined at regular intervals. Saturated horizontal hydraulic conductivity (Khsat) and vertical (Kvsat) was estimated at two depths: 10–20 and 30–40 cm below the peat surface, whereas ρbd was estimated for the full profile. We consider two separate zones, one a riparian zone extending 10 m from the stream and a second zone in the bog interior. We found that the Ksat was higher (~10–5 m s–1) in the bog interior than that in the riparian zone (~10–6 m s–1), whereas the converse applied to bulk density, with lowest density (~0.055 g cm–3) at the interior and highest (~0.11 g cm–3) at the riparian zone. In general, we found Khsat to be approximately twice the Kvsat. These results support the idea that the lower Ksat at the margins control the hydrology of blanket peatlands. It is therefore important that the spatial variation of these two key properties be accommodated in hydrological models if the correct rainfall runoff characteristics are to be correctly modelled. Stream flow analysis over 3 years at the peatland catchment outlet showed that the stream runoff was composed of 8% base flow and 92% flood flow, suggesting that this blanket peatland is a source rather than a sink for floodwaters. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号