首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Large-eddy simulations were conducted to investigate the mechanism of pollutant removal from a three-dimensional street canyon. Five block configurations with aspect ratios (building height to length) of 1, 2, 4, 8 and $\infty $ were used to create an urban-like array. A pollutant was released from a ground-level line source at the centre of the target canyon floor. For smaller aspect ratios, the relative contribution of the turbulent mass flux to net mass flux at the roof level, which was spatially averaged along the roof-level ventilation area, was closer to unity, indicating that turbulent motions mainly affected pollutant removal from the top of the canyon. As aspect ratio increased, the relative contribution became smaller, owing to strong upwind motions. However, the relative contribution again reached near unity for the infinite aspect ratio (i.e. a two-dimensional street canyon) because of lowered lateral flow convergence. At least 75 % of total emissions from the three-dimensional street canyon were attributable to turbulent motions. Pollutant removal by turbulent motions was related to the coherent structures of low-momentum fluid above the canyons. Though the coherent structure size of the low-momentum fluid differed, the positions of low-momentum fluid largely corresponded to instantaneous high concentrations of pollutant above the target canyon, irrespective of canyon geometry.  相似文献   

2.
3.
Flow resistance, ventilation, and pollutant removal for idealized two-dimensional (2D) street canyons of different building-height to street-width (aspect) ratios $AR$ are examined using the friction factor $f$ , air exchange rate (ACH), and pollutant exchange rate (PCH), respectively, calculated by large-eddy simulation (LES). The flows are basically classified into three characteristic regimes, namely isolated roughness, wake interference, and skimming flow, as functions of the aspect ratios. The LES results are validated by various experimental and numerical datasets available in the literature. The friction factor increases with decreasing aspect ratio and reaches a peak at $AR = 0.1$ in the isolated roughness regime and decreases thereafter. As with the friction factor, the ACH increases with decreasing aspect ratio in the wake interference and skimming flow regimes, signifying the improved aged air removal for a wider street canyon. The PCH exhibits a behaviour different from its ACH counterpart in the range of aspect ratios tested. Pollutants are most effectively removed from the street canyon with $AR = 0.5$ . However, a minimum of PCH is found nearby at $AR = 0.3$ , at which the pollutant removal is sharply weakened. Besides, the ACH and PCH are partitioned into the mean and turbulent components to compare their relative contributions. In line with our earlier Reynolds-averaged Navier–Stokes calculations (Liu et al., Atmos Environ 45:4763–4769, 2011), the current LES shows that the turbulent components contribute more to both ACH and PCH, consistently demonstrating the importance of atmospheric turbulence in the ventilation and pollutant removal for urban areas.  相似文献   

4.
Large-eddy simulations are conducted to investigate the effects of the incoming turbulent structure of the flow on pollutant removal from an ideal canyon. The target canyon is a two-dimensional street canyon with an aspect ratio of 1.0 (building height to street width). Three turbulent flows upwind of the street canyon are generated by using different block configurations, and a tracer gas is released as a ground-level line source at the centre of the canyon floor. Mean velocity profiles for the three flows are similar, except near the roof. However, the root-mean-square values of the velocity fluctuations and the Reynolds shear stress increase with the friction velocity of the incoming turbulent flow. The spatially-averaged concentration within the canyon decreases with increasing friction velocity. Coherent structures of low-momentum fluid, generated above the upwind block configurations, contribute to pollutant removal, and the amount of pollutant removal is directly related to the size of the coherent structure.  相似文献   

5.
Boundary-Layer Meteorology - This study expands the study conducted by Zhang et al. (Boundary-Layer Meteorol, 2022, Vol. 183, 97–123) to elucidate turbulent structures within an ideal...  相似文献   

6.
A large-eddy simulation (LES) model, using the one-equation subgrid-scale (SGS) parametrization, was developed to study the flow and pollutant transport in and above urban street canyons. Three identical two-dimensional (2D) street canyons of unity aspect ratio, each consisting of a ground-level area source of constant pollutant concentration, are evenly aligned in a cross-flow in the streamwise direction x. The flow falls into the skimming flow regime. A larger computational domain is adopted to accurately resolve the turbulence above roof level and its influence on the flow characteristics in the street canyons. The LES calculated statistics of wind and pollutant transports agree well with other field, laboratory and modelling results available in the literature. The maximum wind velocity standard deviations σ i in the streamwise (σ u ), spanwise (σ v ) and vertical (σ w ) directions are located near the roof-level windward corners. Moreover, a second σ w peak is found at z ≈ 1.5h (h is the building height) over the street canyons. Normalizing σ i by the local friction velocity u *, it is found that σ u /u * ≈ 1.8, σ v /u * ≈ 1.3 and σ w /u * ≈ 1.25 exhibiting rather uniform values in the urban roughness sublayer. Quadrant analysis of the vertical momentum flux u′′w′′ shows that, while the inward and outward interactions are small, the sweeps and ejections dominate the momentum transport over the street canyons. In the x direction, the two-point correlations of velocity R v,x and R w,x drop to zero at a separation larger than h but R u,x (= 0.2) persists even at a separation of half the domain size. Partitioning the convective transfer coefficient Ω T of pollutant into its removal and re-entry components, an increasing pollutant re-entrainment from 26.3 to 43.3% in the x direction is revealed, suggesting the impact of background pollutant on the air quality in street canyons.  相似文献   

7.
Boundary-Layer Meteorology - Spectral proper orthogonal decomposition (SPOD) is applied as a post-processing technique to elucidate the relationship between turbulent motion and pollutant removal...  相似文献   

8.
吕萍  袁九毅  张文煜 《高原气象》2004,23(4):534-539
利用数值模拟方法研究了微尺度街道峡谷范围内街谷几何结构及街道两侧建筑物高度对称性对街谷内流场及机动车排放污染物扩散规律的影响。结果表明:当街道峡谷高宽比>2.1时,街谷内的流场结构由一个完整的垂直涡旋变为上下两个反向运动的强弱不同的垂直涡旋。各类型街谷内污染物扩散水平从强到弱依次为迎风面建筑物高度大于背风面建筑物高度的街道峡谷,迎风面建筑物高度小于背风面建筑物高度的街道峡谷;平行型街道峡谷。  相似文献   

9.
Boundary-Layer Meteorology - Techniques for improving the removal of pollution from urban canyons are crucial for air quality control in cities. The removal mainly occurs at the building roof...  相似文献   

10.
Our study employed large-eddy simulation (LES) based on a one-equation subgrid-scale model to investigate the flow field and pollutant dispersion characteristics inside urban street canyons. Unstable thermal stratification was produced by heating the ground of the street canyon. Using the Boussinesq approximation, thermal buoyancy forces were taken into account in both the Navier–Stokes equations and the transport equation for subgrid-scale turbulent kinetic energy (TKE). The LESs were validated against experimental data obtained in wind-tunnel studies before the model was applied to study the detailed turbulence, temperature, and pollutant dispersion characteristics in the street canyon of aspect ratio 1. The effects of different Richardson numbers (Ri) were investigated. The ground heating significantly enhanced mean flow, turbulence, and pollutant flux inside the street canyon, but weakened the shear at the roof level. The mean flow was observed to be no longer isolated from the free stream and fresh air could be entrained into the street canyon at the roof-level leeward corner. Weighed against higher temperature, the ground heating facilitated pollutant removal from the street canyon.  相似文献   

11.
Boundary-Layer Meteorology - Coherent flow structures and pollutant dispersion in a spanwise-long street canyon are investigated using a parallelized large-eddy-simulation model. Low- and...  相似文献   

12.
A large-eddy simulation (LES) with a one-equation subgrid-scale (SGS) model was developed to investigate the flow field and pollutant dispersion inside street canyons of high aspect ratio (AR). A 1/7th power-law wall model was implemented near rigid walls to mitigate the demanding near-wall resolution requirements in LES. This LES model had been extensively validated against experimental results for street canyons of AR = 1 and 2 before it was applied to the cases of AR = 3 and 5. A ground-level passive pollutant line source, located in the middle of the street, was used to simulate vehicular emissions. Three and five vertically aligned primary recirculations were developed in the street canyons of AR 3 and 5, respectively. The ground-level mean wind speed was less than 0.5% of the free stream value, which makes it difficult for the pollutant to be transported upward for removal. High pollutant concentration and variance were found near the buildings where the air flow is upwards. It was found that the velocity fluctuation, pollutant concentration and variance were all closely related to the interactions between the primary recirculations and/or the free surface layer. Several quantities, which are non-linear functions of AR, were introduced to quantify the air quality in street canyons of different configurations.  相似文献   

13.
An observational campaign was conducted in the street canyon of Zhujiang Road in Nanjing city in 2007.Hourly mean concentrations of PM10 were measured at street and roof levels.The Operational Street Pollution Model(OSPM)street canyon dispersion model was used to calculate the street concentrations and the results were compared with the measurements.The results show that there is good agreement between measured and predicted concentrations.The correlation coecient R2 values(R2 is a measure of the correlation of the predicted and measured time series of concentrations)are 0.5319,0.8044,and 0.6630 for the scatter plots of PM10 corresponding to light wind speed conditions,higher wind speed conditions,and all wind speed conditions,respectively.PM10 concentrations tend to be smaller for the higher wind speed cases and decrease rapidly with increasing wind speed.The presentations of measured and modelled concentration dependence on wind direction show fairly good agreement.PM10 concentrations measured on the windward side are relatively smaller,compared with the corresponding results for the leeward side.This study demonstrates that it is possible to use the OSPM to model PM10 dispersion rules for an urban street canyon.  相似文献   

14.
A validated large-eddy simulation model was employed to study the effect of the aspect ratio and ground heating on the flow and pollutant dispersion in urban street canyons. Three ground-heating intensities (neutral, weak and strong) were imposed in street canyons of aspect ratio 1, 2, and 0.5. The detailed patterns of flow, turbulence, temperature and pollutant transport were analyzed and compared. Significant changes of flow and scalar patterns were caused by ground heating in the street canyon of aspect ratio 2 and 0.5, while only the street canyon of aspect ratio 0.5 showed a change in flow regime (from wake interference flow to skimming flow). The street canyon of aspect ratio 1 does not show any significant change in the flow field. Ground heating generated strong mixing of heat and pollutant; the normalized temperature inside street canyons was approximately spatially uniform and somewhat insensitive to the aspect ratio and heating intensity. This study helps elucidate the combined effects of urban geometry and thermal stratification on the urban canyon flow and pollutant dispersion.  相似文献   

15.
We experimentally investigate the effect of a typical building covering: the gable roof, on the flow and air exchange in urban canyons. In general, the morphology of the urban canopy is very varied and complex, depending on a large number of factors, such as building arrangement, or the morphology of the terrain. Therefore we focus on a simple, prototypal shape, the two-dimensional canyon, with the aim of elucidating some fundamental phenomena driving the street-canyon ventilation. Experiments are performed in a water channel, over an array of identical prismatic obstacles representing an idealized urban canopy. The aspect ratio, i.e. canyon-width to building-height ratio, ranges from 1 to 6. Gable roof buildings with 1:1 pitch are compared with flat roofed buildings. Velocity is measured using a particle-image-velocimetry technique with flow dynamics discussed in terms of mean flow and second- and third-order statistical moments of the velocity. The ventilation is interpreted by means of a simple well-mixed box model and the outflow rate and mean residence time are computed. Results show that gable roofs tend to delay the transition from the skimming-flow to the wake-interference regime and promote the development of a deeper and more turbulent roughness layer. The presence of a gable roof significantly increases the momentum flux, especially for high packing density. The air exchange is improved compared to the flat roof buildings, and the beneficial effect is more significant for narrow canyons. Accordingly, for unit aspect ratio gable roofs reduce the mean residence time by a factor of 0.37 compared to flat roofs, whereas the decrease is only by a factor of 0.9 at the largest aspect ratio. Data analysis indicates that, for flat roof buildings, the mean residence time increases by 30% when the aspect ratio is decreased from 6 to 2, whereas this parameter is only weakly dependent on aspect ratio in the case of gable roofs.  相似文献   

16.
城市街道峡谷汽车尾气污染的数值模拟   总被引:4,自引:3,他引:4  
李磊  张镭  胡非 《高原气象》2004,23(1):97-102
建立了一个简单的三维街道峡谷空气污染模式,并用实测资料进行了验证。利用建立的模式设计了7种试验方案,对街道峡谷内的污染状况进行了模拟。以CO为模拟对象的数值试验结果表明,街道峡谷上空的风速风向条件是决定街道峡谷内的污染状况的重要因素。峡谷上空风向与街道轴线的夹角越大、风速越小,则街道地面CO浓度越高。以现有的兰州典型车流量和排放因子,兰州街道地面CO浓度容易超标;若不控制车流量,到2008年,即使兰州上路汽车排放达标,但街道地面CO浓度仍然容易超标。  相似文献   

17.
18.
An analytical model has been developed for the flow along a street canyon (of height H and width W), generated by an external wind blowing at any angle relative to the axis of the street. Initially, we consider the special case of a wind blowing parallel to the street. The interior of the street is decomposed into three regions, and the flow within each region is assumed to depend only on the external wind and the distance to the closest solid boundary. This decomposition leads to two different flow regimes: one for narrow streets (H/W > 1/2) and one for wide streets (H/W < 1/2). The theoretical model agrees well with results obtained from numerical simulations using a Reynolds-Averaged Navier–Stokes model. We then generalize the model to the case of arbitrary wind direction. Numerical solutions show that the streamlines of the mean flow in the street have a spiral form, and for most angles of incidence, the mass flux along the street scales on the component of the external wind resolved parallel to the street. We use this result to generalize the model derived for wind blowing parallel to the street, and the results from this model agree well with the numerical simulations. The model that has been developed can be evaluated rapidly using only very modest computing power, so it is suitable for use as an operational tool.  相似文献   

19.
This study constitutes a further step in the analysis of the performances of a street network model to simulate atmospheric pollutant dispersion in urban areas. The model, named SIRANE, is based on the decomposition of the urban atmosphere into two sub-domains: the urban boundary layer, whose dynamics is assumed to be well established, and the urban canopy, represented as a series of interconnected boxes. Parametric laws govern the mass exchanges between the boxes under the assumption that the pollutant dispersion within the canopy can be fully simulated by modelling three main bulk transfer phenomena: channelling along street axes, transfers at street intersections, and vertical exchange between street canyons and the overlying atmosphere. Here, we aim to evaluate the reliability of the parametrizations adopted to simulate these phenomena, by focusing on their possible dependence on the external wind direction. To this end, we test the model against concentration measurements within an idealized urban district whose geometrical layout closely matches the street network represented in SIRANE. The analysis is performed for an urban array with a fixed geometry and a varying wind incidence angle. The results show that the model provides generally good results with the reference parametrizations adopted in SIRANE and that its performances are quite robust for a wide range of the model parameters. This proves the reliability of the street network approach in simulating pollutant dispersion in densely built city districts. The results also show that the model performances may be improved by considering a dependence of the wind fluctuations at street intersections and of the vertical exchange velocity on the direction of the incident wind. This opens the way for further investigations to clarify the dependence of these parameters on wind direction and street aspect ratios.  相似文献   

20.
Dispersion of particles, as evidenced by changes in their number distributions (PNDs) and concentrations (PNCs), in urban street canyons, is still not well understood. This study compares measurements by a fast-response particle spectrometer (DMS500) of the PNDs and the PNCs (5–1000 nm, sampled at 1 Hz) at street and rooftop levels in a Cambridge UK street canyon, and examines mixing, physical and chemical conversion processes, and the competing influences of traffic volume and rooftop wind speed on the PNDs and the PNCs in various size ranges. PNCs at street level were ≈6.5 times higher than at rooftop. Street-level PNCs followed the traffic volume and decreased with increasing wind speed, showing a larger influence of wind speed on 30–300 nm particles than on 5–30 nm particles. Conversely, rooftop PNCs in the 5–30 nm size range increased with wind speed, whereas those for particles between 30 and 300 nm did not vary with wind speed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号