首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
新型SMA耗能器及结构地震反应控制试验研究   总被引:27,自引:4,他引:27  
利用NiTi合金丝的超弹性性能,本文提出了两种新型SMA被动耗能器,分别称之为拉伸型SMA耗能器和剪刀型SMA耗能器。通过对耗能器的构造设计,安装在耗能器中的NiTi丝始终处于受拉状态,避免了合金丝在结构振动过程中受压屈曲。文中阐述了拉伸型SMA耗能器和剪刀型SMA耗能器的构造及工作原理,并将其安装在模型结构上进行了地震模拟振动台试验,验证了新型SMA耗能器的减振效果。  相似文献   

2.
Control devices incorporated with shape memory alloy   总被引:2,自引:1,他引:1  
Shape Memory Alloy (SMA) is a type of material that offers some unique characteristics for use in devices for vibration control applications. Based on SMA's material properties, four types of control devices that incorporate NiTi SMA wires are introduced in this paper, which include three types of dampers (SMA damper, SMA-MR damper and SMA-friction damper) and one kind of isolation bearing (SMA-rubber bearing). Mechanical models of these devices and their experimental verifications are presented. To investigate the control performance of these devices, the SMA-MR damper and SMA-rubber bearing are applied to structures. The results show that the control devices could be effective in reducing the seismic response of structures.  相似文献   

3.
This paper investigates the seismic response control of a 20-story nonlinear benchmark building with a new recentering variable friction device (RVFD). The RVFD combines energy dissipation capabilities of a variable friction damper (VFD) with the recentering ability of shape memory alloy (SMA) wires. The VFD that is the first subcomponent of the hybrid device consists of a friction generation unit and piezoelectric actuators. The clamping force of the VFD can be adjusted according to the current level of ground motion by adjusting the voltage level of piezoelectric actuators. SMA wires that exhibit a unique hysteretic behavior and full shape recovery after experiencing large strains is the second subcomponent of the hybrid device. Numerical simulations of a seismically excited 20-story benchmark building are conducted to evaluate the performance of the hybrid device. A continuous hysteretic model is used to capture frictional behavior of the VFD and a neuro-fuzzy model is employed to describe highly nonlinear behavior of the SMA components of the hybrid device. A fuzzy logic controller is developed to adjust the voltage level of VFDs for favorable performance in an RVFD hybrid application. Results show that the RVFD modulated with a fuzzy logic control strategy can effectively reduce interstory drifts and permanent deformations without increasing acceleration response of the benchmark building for most cases. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
This paper presents an experimental and numerical study to investigate the hysteretic performance of a new type of isolator consisting of shape memory alloy springs and friction bearing called an SMA spring-friction bearing (SFB). The SFB is a sliding-type isolator with SMA devices used for the seismic protection of engineering structures. The principle of operation of the isolation bearing is introduced. In order to explore the possibility of applying SMA elements in passive seismic control devices, large diameter superelastic tension/compression NiTi SMA helical springs used in the SFB isolator were developed. Mechanical experiments of the SMA helical spring were carried out to understand its superelastic characteristics. After that, a series of quasi-static tests on a single SFB isolator prototype were conducted to measure its force-displacement relationships for different loading conditions and study the corresponding variation law of its mechanical performance. The experimental results demonstrate that the SFB exhibits full hysteretic curves, excellent energy dissipation capacity, and moderate recentering ability. Finally, a theoretical model capable of emulating the hysteretic behavior of the SMA-based isolator was then established and implemented in MATLAB software. The comparison of the numerical results with the experimental results shows the efficacy of the proposed model for simulating the response of the SFB.  相似文献   

5.
Given their excellent self‐centering and energy‐dissipating capabilities, superelastic shape memory alloys (SMAs) become an emerging structural material in the field of earthquake engineering. This paper presents experimental and numerical studies on a scaled self‐centering steel frame with novel SMA braces (SMAB), which utilize superelastic Ni–Ti wires. The braces were fabricated and cyclically characterized before their installation in a two‐story one‐bay steel frame. The equivalent viscous damping ratio and ‘post‐yield’ stiffness ratio of the tested braces are around 5% and 0.15, respectively. In particular, the frame was seismically designed with nearly all pin connections, including the pinned column bases. To assess the seismic performance of the SMA braced frame (SMABF), a series of shake table tests were conducted, in which the SMABF was subjected to ground motions with incremental seismic intensity levels. No repair or replacement of structural members was performed during the entire series of tests. Experimental results showed that the SMAB could withstand several strong earthquakes with very limited capacity degradation. Thanks to the self‐centering capacity and pin‐connection design, the steel frame was subjected to limited damage and zero residual deformation even if the peak interstory drift ratio exceeded 2%. Good agreement was found between the experimental results and numerical simulations. The current study validates the prospect of using SMAB as a standalone seismic‐resisting component in critical building structures when high seismic performance or earthquake resilience is desirable under moderate and strong earthquakes. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
This study proposes an innovative passive vibration mitigation device employing essentially nonlinear elastomeric springs as its most critical component. Essential nonlinearity denotes the absence (or near absence) of a linear component in the stiffness characteristics of these elastomeric springs. These devices were implemented and tested on a large‐scale nine‐story model building structure. The main focus of these devices is to mitigate structural response under impulse‐like and seismic loading when the structure remains elastic. During the design process of the device, numerical simulations, optimizations, and parametric studies of the structure‐device system were performed to obtain stiffness parameters for the devices so that they can maximize the apparent damping of the fundamental mode of the structure. Pyramidal elastomeric springs were employed to physically realize the optimized essentially nonlinear spring components. Component‐level finite element analyses and experiments were conducted to design the nonlinear springs. Finally, shake table tests using impulse‐like and seismic excitation with different loading levels were performed to experimentally evaluate the performance of the device. Experimental results demonstrate that the properly designed devices can mitigate structural vibration responses, including floor acceleration, displacement, and column strain in an effective, rapid, and robust fashion. Comparison between numerical and experimental results verified the computational model of the nonlinear system and provided a comprehensive verification for the proposed device. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
The mid‐story isolation design method is recently gaining popularity for the seismic protective design of buildings located in the areas of high population. In a mid‐story isolated building, the isolation system is incorporated into the mid‐story rather than the base of the building. In this paper, the dynamic characteristics and seismic responses of mid‐story isolated buildings are investigated using a simplified three‐lumped‐mass structural model for which equivalent linear properties are formulated. From the parametric study, it is found that the nominal frequencies of the superstructure and the substructure, respectively, above and below the isolation system have significant influences on the isolation frequency and equivalent damping ratio of a mid‐story isolated building. Moreover, the mass and stiffness of the substructure are of greater significance than the superstructure in affecting the dynamic characteristics of the isolated building. Besides, based on the response spectrum analysis, it is noted that the higher mode responses may contribute significantly to the story shear force of the substructure. Consequently, the equivalent lateral force procedure of design codes should carefully include the effects of higher modes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
The seismic design of multi‐story buildings asymmetric in plan yet regular in elevation and stiffened with ductile RC structural walls is addressed. A realistic modeling of the non‐linear ductile behavior of the RC walls is considered in combination with the characteristics of the dynamic torsional response of asymmetric buildings. Design criteria such as the determination of the system ductility, taking into account the location and ductility demand of the RC walls, the story‐drift demand at the softer (most displaced) edge of the building under the design earthquake, the allowable ductility (ultimate limit state) and the allowable story‐drift (performance goals) are discussed. The definition of an eccentricity of the earthquake‐equivalent lateral force is proposed and used to determine the effective displacement profile of the building yet not the strength distribution under the design earthquake. Furthermore, an appropriate procedure is proposed to calculate the fundamental frequency and the earthquake‐equivalent lateral force. A new deformation‐based seismic design method taking into account the characteristics of the dynamic torsional response, the ductility of the RC walls, the system ductility and the story‐drift at the softer (most displaced) edge of the building is presented and illustrated with an example of seismic design of a multi‐story asymmetric RC wall building. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

9.
The seismic response of a multi‐span continuous bridge isolated with novel superelastic‐friction base isolator (S‐FBI) is investigated under near‐field earthquakes. The isolation system consists of a flat steel‐Teflon sliding bearing and a superelastic NiTi shape memory alloy (SMA) device. The key design parameters of an S‐FBI system are the natural period of the isolated bridge, the yielding displacement of the SMA device, and the friction coefficient of the sliding bearings. The goal of this study is to obtain optimal values for each design parameter by performing sensitivity analysis of a bridge isolated by an S‐FBI system. First, a three‐span continuous bridge is modeled as two‐degrees‐of‐freedom with the S‐FBI system. A neuro‐fuzzy model is used to capture rate‐ and temperature‐dependent nonlinear behavior of the SMA device. Then, a set of nonlinear time history analyses of the isolated bridge is performed. The variation of the peak response quantities of interest is shown as a function of design parameters of the S‐FBI system and the optimal values for each parameter are evaluated. Next, in order to assess the effectiveness of the S‐FBI system, the response of the bridge isolated by the S‐FBI system is compared with the response of the non‐isolated bridge and the same bridge isolated by pure‐friction (P‐F) sliding isolation system. Finally, the influence of temperature variations on the performance of the S‐FBI system is evaluated. The results show that the optimum design of a bridge with the S‐FBI system can be achieved by a judicious specification of design parameters. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
This paper deals with the optimal design of yielding metallic dampers and friction dampers together as they both have similar design characteristics and parameters. Ample tests and analytical studies have confirmed the effectiveness of these energy dissipation devices for seismic response control and protection of building structures. Since these devices are strongly non‐linear with several parameters controlling their behaviour, their current design procedures are usually cumbersome and not optimal. In this paper, a methodology is presented to determine the optimal design parameters for the devices installed at different locations in a building for a desired performance objective. For a yielding metallic damper, the design parameters of interest are the device yield level, device stiffness, and brace stiffness. For a friction device, the parameters are the slip load level and brace stiffness. Since the devices and the structures installed with these devices behave in a highly non‐linearly manner, and thus must be evaluated by a step‐by‐step time history approach, the genetic algorithm is used to obtain the globally optimal solution. This optimal search approach allows an unusual flexibility in the choice of performance objectives. For demonstration purposes, several sets of numerical examples of optimal damper designs with different performance objectives are presented. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
SMA-橡胶支座的力学性能试验研究   总被引:8,自引:2,他引:6  
SMA-橡胶支座是一种由叠层橡胶垫和形状记忆合金(SMA)复合而成的新型隔震支座。阐明了SMA-橡胶支座的设计思路和工作机理,通过SMA-橡胶支座实物模型的伪动力试验,考察了支座的水平和竖向刚度、耗能能力和等效阻尼比,研究了位移幅值、加载频率、竖向荷载等参数对支座力学性能的影响。研究结果表明,SMA-橡胶支座工作性能稳定,耗能能力较强,是一种性能优良的新型隔震装置。  相似文献   

12.
The seismic performance of three‐ and six‐story buildings with fluidic self‐centering system is probabilistically assessed. The fluidic self‐centering systems consist of devices that are based on the technology of fluid viscous dampers but built in a way that pressurization of the devices results in preload that is explored to reduce or eliminate residual drift. The design of these buildings followed a procedure that parallels the design for structures with damping systems in ASCE 7 but modified to include the preload effect. Reference conventional buildings were also designed per ASCE 7 for comparison. These buildings were then analyzed to examine and compare their seismic collapse resistance and residual drift, where the residual drift limits of 0.2, 0.5, 1.0 and 2.0% of story height were selected as important thresholds. The study further calculated the mean annual frequency of collapse and corresponding exceedance probability over 50 years, and the mean annual frequency of exceeding the threshold residual story drift limits and the corresponding exceedance probability over 50 years. Variations in the design procedures by considering increased displacement capacity or damping or preload of the devices, different types of damping, increased ultimate strength of the self‐centering device–brace systems and increased frame strength were considered. It was found that increasing either the ultimate force capacity of the self‐centering device–brace system or the frame strength results in important improvements in the collapse resistance and in minimizing residual drift, whereas the variation of other design parameters has minor effects. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
A damper device based on shape memory alloy (SMA) wires is developed for structural control implementation. The design procedures of the SMA damper are presented. As a case study, eight such SMA dampers are installed in a frame structure to verify the effectiveness of the damper devices. Experimental results show that vibration decay of the SMA damper controlled frame is much faster than that of the uncontrolled frame. The finite‐element method is adopted to conduct the free and forced vibration analysis of the controlled and uncontrolled frame. The experimental and numerical results illustrate that the developed SMA dampers are very effective in reducing structural response and have great potential for use as efficient energy dissipation devices with the advantages of good control of force and no lifetime limits, etc. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

14.
The original structural design of this case study consisted of five basement floors and a 34‐story hotel tower in Kaohsiung, Taiwan. The construction started in 1993, and the erection of the entire steel frame and the pouring of concrete slabs up to the 26th floor were completed before 1996. However, construction of the original hotel was subsequently suspended for 10 years. Recently, this building has been retrofitted for residential purposes. Buckling restrained braces (BRBs) and eccentrically braced frames were incorporated into the seismic design of the new residential tower. This paper presents the seismic resisting structural system, seismic design criteria, full‐scale test results of one BRB member and the as‐built welded moment connections. Test results confirm that the two side web‐plate stiffening details can effectively improve the rotational capacity of welded moment connection. The paper also discusses the analytical models for simulating the experimental responses of the BRB members and the welded moment connections. Nonlinear response history analyses (NLRHA) indicate that the inelastic deformational demands of the original and the redesigned structures induced by the maximum considered earthquakes are less than those found in the seismic building codes or laboratory tests. This paper also proposes a ground motion scaling method considering multi‐mode effects for NLRHA of the example building. It is shown that the proposed scaling method worked well in reducing the scatter in estimated peak seismic demands. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
This paper examines the quasi-static cyclic behavior,lateral strength and equivalent damping capacities of a system of post-tensioned segmental bridge columns tied with large diameter martensitic Shape Memory Alloy(SMA) link-bars.Moment-curvature constitutive relationships are formulated and analysis tools are developed for the PT column,including a modified four-spring model prepared for the SMA bars.The suggested system is exemplified using a column with an aspect ratio of 7.5 and twelve 36.5 mm diameter NiTi martensitic SMA bars.A post-tensioning force of 40% to 60% of the tendon yield strength is applied in order to obtain a self re-centering system,considering the residual stress of the martensitic SMA bars.The cyclic response results show that the lateral strength remains consistently around 10% of the total vertical load and the equivalent viscous damping ratios reach 10%-12% of critical.When large diameter NiTi superelastic SMA bars are incorporated into the column system,the cyclic response varies substantially.The creep behavior of the superelastic SMA bar is accounted for since it affects the re-centering capability of the column.Two examples are presented to emphasize the modeling sensitivities for these special bars and quantify their cyclic behavior effects within the column assembly.  相似文献   

16.
This paper presents a statistical performance analysis of a semi‐active structural control system for suppressing the vibration response of building structures during strong seismic events. The proposed semi‐active mass damper device consists of a high‐frequency mass damper with large stiffness, and an actively controlled interaction element that connects the mass damper to the structure. Through actively modulating the operating states of the interaction elements according to pre‐specified control logic, vibrational energy in the structure is dissipated in the mass damper device and the vibration of the structure is thus suppressed. The control logic, categorized under active interaction control, is defined directly in physical space by minimizing the inter‐storey drift of the structure to the maximum extent. This semi‐active structural control approach has been shown to be effective in reducing the vibration response of building structures due to specific earthquake ground motions. To further evaluate the control performance, a Monte Carlo simulation of the seismic response of a three‐storey steel‐framed building model equipped with the proposed semi‐active mass damper device is performed based on a large ensemble of artificially generated earthquake ground motions. A procedure for generating code‐compatible artificial earthquake accelerograms is also briefly described. The results obtained clearly demonstrate the effectiveness of the proposed semi‐active mass damper device in controlling vibrations of building structures during large earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

17.
采用复合型铅粘弹性阻尼器对带转换层框肢剪力墙结构的某酒店进行了耗能减震设计,对耗能减震结构和钢支撑结构进行了对比分析,包括反应谱和局部非线性多遇地震作用和罕遇地震作用下的时程分析。结果表明,底部框架结构布置复合型铅粘弹性阻尼器后,在多遇和罕遇地震情况下层间位移能满足《建筑抗震设计规范》要求,并且采用耗能减震结构能优化整体结构,不会对转换层上部结构产生不利的影响,能更好地改善结构的抗震性能。  相似文献   

18.
An extensive experimental program of shaking table tests on reduced‐scale structural models was carried out within the activities of the MANSIDE project, for the development of new seismic isolation and energy dissipation devices based on shape memory alloys (SMAs). The aim of the experimental program was to compare the behaviour of structures endowed with innovative SMA‐based devices to the behaviour of conventional structures and of structures endowed with currently used passive control systems. This paper presents a comprehensive overview of the main results of the shaking table tests carried out on the models with and without special braces. Two different types of energy dissipating and re‐centring braces have been considered to enhance the seismic performances of the tested model. They are based on the hysteretic properties of steel elements and on the superelastic properties of SMAs, respectively. The addition of passive control braces in the reinforced concrete frame resulted in significant benefits on the overall seismic behaviour. The seismic intensity producing structural collapse was considerably raised, interstorey drifts and shear forces in columns were drastically reduced. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

19.
Nonstructural reinforced concrete flat walls architecturally designed as exterior/partition walls in concrete buildings were severely damaged by the 2011 earthquake off the Pacific coast of Tohoku. This damage was observed in the monolithic nonstructural flat walls of relatively old ductile concrete buildings. Although these flat walls might affect the overall seismic performance and behavior of a building, the nonstructural wall effects have not been clarified because of the complex interactions among the structural components. To understand these effects, this paper conducts an experimental and numerical investigation of the nonstructural wall effects, focusing on a typical residential building damaged by the 2011 earthquake. A single‐story, one‐bay moment‐resisting frame model of the building with a nonstructural flat wall was tested to clarify the fundamental behavior. The results reveal that the wall significantly contributed to the seismic performance of the overall frame until it failed in shear, subsequently losing structural effectiveness. Such experimental wall behavior could be simulated by the isoparametric element model. Moreover, the structural effects of the nonstructural flat walls on the global seismic performance and behavior of the investigated building were discussed through earthquake response analyses using ground motions recorded near the building site and pushover analyses. Consequently, the building damage could be simulated in an analytical case considering the nonstructural flat walls, showing larger inter‐story drifts in the lower stories due to softening of the walls. The analytical results also indicated that the softening of the nonstructural flat walls decreased the building ductility, as defined by ultimate inter‐story drifts. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

20.
A new passive seismic response control device has been developed, fabricated, and tested by the authors and shown to be capable of producing negative stiffness via a purely mechanical mechanism, thus representing a new generation of seismic protection devices. Although the concept of negative stiffness may appear to be a reversal on the desired relationship between the force and displacement in structures (the desired relationship being that the product of restoring force and displacement is nonnegative), when implemented in parallel with a structure having positive stiffness, the combined system appears to have substantially reduced stiffness while remaining stable. Thus, there is an ‘apparent weakening and softening’ of the structure that results in reduced forces and increased displacements (where the weakening and softening is of a non‐damaging nature in that it occurs in a seismic protection device rather than within the structural framing system). Any excessive displacement response can then be limited by incorporating a damping device in parallel with the negative stiffness device. The combination of negative stiffness and passive damping provides a large degree of control over the expected performance of the structure. In this paper, a numerical study is presented on the performance of a seismically isolated highway bridge model that is subjected to various strong earthquake ground motions. The Negative Stiffness Devices (NSDs) are described along with their hysteretic behavior as obtained from a series of cyclic tests wherein the tests were conducted using a modified design of the NSDs (modified for testing within the bridge model). Using the results from the cyclic tests, numerical simulations of the seismic response of the isolated bridge model were conducted for various configurations (with/without negative stiffness devices and/or viscous dampers). The results demonstrate that the addition of negative stiffness devices reduces the base shear substantially, while the deck displacement is limited to acceptable values. This assessment was conducted as part of a NEES (Network for Earthquake Engineering Simulation) project which included shaking table tests of a quarter‐scale highway bridge model. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号