首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The corner gusset plates in a steel braced frame can be subjected to forces not only from the brace but also from the effects of the frame actions. In this study, several finite element models are constructed to analyze the gusset‐to‐beam and gusset‐to‐column interface forces. It is found that the frame actions affect the gusset interface force distributions significantly. A simplified strut model to represent the gusset plate is adopted to evaluate the frame action forces. In addition, the generalized uniform force method is adopted as it provides more freedom for designers to configure the gusset plate shapes than using the uniform force method. In this paper, a performance‐based design method is proposed. The gusset interface force demands take into account the combined effect of the brace maximum axial force capacity and the peak beam shear possibly developed in the frame. The specimen design and key results of a series of full‐scale three‐story buckling‐restrained braced frame (BRBF) hybrid tests are discussed. The gusset interface cracks observed at inter‐story drift greater than 0.03 radians can be well predicted by using the proposed design method. The BRBF tests and analyses confirm that the proposed design method is reasonable. The effectiveness of varying the width of gusset edge stiffeners in reducing the gusset tip stress concentrations is also investigated. This paper concludes with recommendations for the seismic design of BRBF corner gusset plates. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
This paper is Part II of a two‐part paper describing a full‐scale 3‐story 3‐bay concrete‐filled tube (CFT)/buckling‐restrained braced frame (BRBF) specimen tested using psuedo‐dynamic testing procedures. The first paper described the specimen design, experiment, and simulation, whereas this paper focuses on the experimental responses of BRBs and BRB‐to‐gusset connections. This paper first evaluates the design of the gusset connections and the effects of the added edge stiffeners in improving the seismic performance of gusset connections. Test results suggest that an effective length factor of 2.0 should be considered for the design of the gusset plate without edge stiffeners. Tests also confirm that the cumulative plastic deformation (CPD) capacity of the BRBs adopted in the CFT/BRBF was lower than that found in typical component tests. The tests performed suggest that the reduction in the BRB CPD capacities observed in this full‐scale frame specimen could be due to the significant rotational demands imposed on the BRB‐to‐gusset joints. A simple method of computing such rotational demands from the frame inter‐story drift response demand is proposed. This paper also discusses other key experimental responses of the BRBs, such as effective stiffness, energy dissipation, and ductility demands. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
The design of a three‐story buckling‐restrained braced frame (BRBF) with a single‐diagonal sandwiched BRB and corner gusset was evaluated in cyclic tests of a one‐story, one‐bay BRBF subassembly and dynamic analyses of the frame subjected to earthquakes. The test focused on evaluating (1) the seismic performance of a sandwiched BRB installed in a frame, (2) the effects of free‐edge stiffeners and dual gusset configurations on the corner gusset behavior, (3) the frame and brace action forces in the corner gusset, and (4) the failure mode of the BRBF under the maximum considerable earthquake level. The subassembly frame performed well up to a drift of 2.5% with a maximum axial strain of 1.7% in the BRB. Without free‐edge stiffeners, the single corner gusset plate buckled at a significantly lower strength than that predicted by the specificationof American Institute of Steel Construction (2005). The buckling could be eliminated by using dual corner gusset plates similar in size to the single gusset plate. At low drifts, the frame action force on the corner gusset was of the same magnitude as the brace force. At high drifts, however, the frame action force significantly increased and caused weld fractures at column‐to‐gusset edges. Nonlinear time history analyses were performed on the three‐story BRBF to obtain seismic demands under both design and maximum considerable levels of earthquake loading. The analytical results confirmed that the BRB and corner gusset plate achieved peak drift under cyclic loading test. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
A two‐story buckling‐restrained brace (BRB) frame was tested under bidirectional in‐plane and out‐of‐plane loading to evaluate the BRB stability and gusset plate design. The test comprised pseudo‐dynamic loadings using the 1999 Chi‐Chi earthquake scaled to the 50%, 10%, and 2% probability of exceedance in 50 years and a cyclic regime of increasing amplitudes of up to 3.0% story drift ratio (SDR). The specimen had a unique configuration where the beams were connected to the columns through shear tabs welded to the column flanges and bolted to the beam webs. Stable hysteretic behavior with only minor cracking at the gusset‐to‐column welds was observed under the pseudo‐dynamic tests, with maximum in‐plane and out‐of‐plane SDRs of 2.24% and 1.47% respectively. Stable behavior continued into the cyclic test where fracture of the gusset‐to‐column welds occurred in the first cycle to simultaneous bidirectional SDR of 3.0%. The observed BRB stability is consistent with a methodology developed for BRB frames under simultaneous in‐plane and out‐of‐plane drifts. The specimen behavior was studied using a finite element model. It was shown that gusset plates are subjected to a combination of BRB force and frame action demands, with the latter increasing the gusset‐to‐beam and gusset‐to‐column interface demands by an average of 69% and 83% respectively. Consistent with the test results, failure at the gusset‐to‐column interfaces is computed when frame action demands are included, thus confirming that not considering frame action demands may results in unconservative gusset plate designs. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
The implementation of buckling‐restrained braces (BRBs) for new reinforced concrete frame (RCF) constructions is limited. This study investigates the seismic forces and stability in the BRBs and gussets of a 2‐story full‐scale RCF specimen by using Abaqus models and a newly proposed stability evaluation method. The hybrid and cyclic loading test results are accurately predicted by the Abaqus analyses. Existing methods for computing the gusset interface forces for steel buildings from both the brace and the frame actions are compared with the Abaqus results. The applicability of these methods for the BRB‐RCF design is critically evaluated. It is confirmed that the Parallel‐2 method is suitable for estimating the BRB force demand imposed on the corner gusset and the generalized uniform force method is good for the corner gusset at the base. In addition, existing stability evaluation methods for BRBs and gussets are applied to investigate the out‐of‐plane (OOP) buckling of the first‐story BRB observed at the end of tests. The proposed stability model incorporates the BRB restrainer's flexural effects and 4 rotational springs in assessing the BRB's buckling. This model confirms that the BRB and the gusset's OOP buckling limit states could be coupled and must be evaluated together. By incorporating the flexural effects of the steel casing and the infilled grout, the proposed model satisfactorily predicts the OOP buckling of the first‐story BRB and gussets. These research results can be used for the implementation of BRBs in new RC frame constructions.  相似文献   

6.
A gusset plate is subjected to forces induced from a buckling‐restrained brace (BRB) and frame action. In this study, a performance‐based design method of the gusset connections incorporating a BRB and frame actions is investigated. The force demands resulting from the BRB axial force are computed from the generalized uniform force method. The force demands induced from the frame action effects primarily result from beam shear. A conservative method, which considers the beam axial force effect and the thereafter reduced beam flexural capacity possibly developed at the gusset tips, is adopted in estimating the maximum beam shear. An improved equivalent strut model is used to represent the gusset plate subjected to the frame action effect. The total force demands of the gusset connection are combined from the BRB force and the frame actions. For design purposes, the stress distributions on the gusset interfaces are linearized. The maximum von Mises stress combining the normal and shear stresses is considered as the demand for the gusset plate design. In order to verify the effectiveness of the proposed design method, experiments on a two‐story full‐scale buckling‐restrained braced frame (BRBF) were performed. The chevron and single diagonal brace configurations were arranged in the second and the first stories, respectively. Two different corner gusset connection configurations including one single corner gusset and one coupled corner gusset connection, where two braces in adjacent stories joined at the same beam‐to‐column joint, were tested. The BRBF specimen was subjected to cyclically increasing lateral displacements with a maximum frame drift of 0.04 rad. The maximum story drifts reached 0.035 and 0.061 rad. in the first and the second stories, respectively. At the end of the tests, no fractures were observed on any of the gusset interfaces. Along the gusset interfaces, the normal and shear stress distributions computed from the proposed design procedures and the FEM analysis correlated well with the experimental results. This paper concludes with the procedure and recommendations for the performance‐based design of gusset connections. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
A series of hybrid and cyclic loading tests were conducted on a three‐story single‐bay full‐scale buckling‐restrained braced frame (BRBF) at the Taiwan National Center for Research on Earthquake Engineering in 2010. Six buckling‐restrained braces (BRBs) including two thin BRBs and four end‐slotted BRBs, all using welded end connection details, were installed in the frame specimen. The BRBF was designed to sustain a design basis earthquake in Los Angeles. In the first hybrid test, the maximum inter‐story drift reached nearly 0.030 rad in the second story and one of the thin BRBs in the first story locally bulged and fractured subsequently before the test ended. After replacing the BRBs in the first story with a new pair, a second hybrid test with the same but reversed direction ground motion was applied. The maximum inter‐story drifts reached more than 0.030 rad and some cracks were found on the gusset welds in the second story. The frame responses were satisfactorily predicted by both OpenSees and PISA3D analytical models. The cyclic loading test with triangular lateral force distribution was conducted right after the second hybrid test. The maximum inter‐story drift reached 0.032, 0.031, and 0.008 rad for the first to the third story, respectively. This paper then presents the findings on the local bulging failure of the steel casing by using cyclic test results of two thin BRB specimens. It is found that the steel casing bulging resistance can be computed from an equivalent beam model constructed from the steel core plate width and restraining concrete thickness. This paper concludes with the recommendations on the seismic design of thin BRB steel casings against local bulging failure. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
This paper proposes a novel implementation of buckling‐restrained braces (BRB) in new reinforced concrete (RC) frame construction. Seismic design and analysis methods for using a proposed steel cast‐in anchor bracket (CAB) to transfer normal and shear forces between the BRB and RC members are investigated. A full‐scale two‐story RC frame with BRBs (BRB‐RCF) is tested using hybrid and cyclic loading test procedures. The BRBs were arranged in a zigzag configuration and designed to resist 70% of the story shear. The gusset design incorporates the BRB axial and RCF actions, while the beam and column members comply with ACI 318‐14 seismic design provisions. Test results confirm that the BRBs enhanced the RCF stiffness, strength, and ductility. The hysteresis energy dissipation ratios in the four hybrid tests range from 60% to 94% in the two stories, indicating that BRBs can effectively dissipate seismic input energy. When the inter‐story drift ratio for both stories reached 3.5% in the cyclic loading test, the overall lateral force versus deformation response was still very stable. No failure of the proposed steel CABs and RC discontinuity regions was observed. This study demonstrates that the proposed design and construction methods for the CABs are effective and practical for real applications. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
A welded end‐slot buckling‐restrained brace (WES‐BRB) has been developed at the Taiwan National Center for Research on Earthquake Engineering (NCREE). A steel frame equipped with a WES‐BRB can offer a cost‐effective solution to meet interstory drift and earthquake‐resistant design requirements for seismic steel buildings. According to the WES‐BRB and connection design procedure proposed by NCREE, there are seven key elements of a buckling‐restrained braced frame (BRBF) design that require design checking. In order to assist an engineer with the design of the WES‐BRB members and connections, an innovative cloud service named Brace on Demand has been constructed at NCREE. In this study, using 581 BRBF design examples, the effectiveness of the proposed design procedures to meet all design checks is demonstrated. It is found that the most critical limit states for an initial design are joint region buckling, gusset plate buckling, and gusset‐to‐beam and gusset‐to‐column interface strength. Accordingly, the causes of improper designs and associated strategies for improving the initial designs are discussed in this paper. Recommendations on initial selections including the BRB joint size and gusset plate thickness are given. The paper provides the detailed road map for engineers to develop the spreadsheet for BRB and connection designs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
The seismic performance tests of a full‐scale five‐story passively controlled steel building were conducted on the E‐Defense shaking table in Japan in March 2009. Before the tests, a blind prediction contest was held to allow researchers and practitioners from all over the world to construct analytical models and predict the dynamic responses of the steel frame specimen equipped with buckling‐restrained braces (BRBs) or viscous dampers (VDs). This paper presents the details of two refined prediction models made and results obtained before the tests. When the proposed analytical modeling techniques are adopted as in the two refined prediction models, the overall prediction accuracy is about 90%. Sensitivity studies conducted after the tests are also presented in this paper. The effects of varying each modeling feature on the response simulation accuracy have been investigated. The analytical results suggest that considering concrete full‐composite actions for beam members could improve prediction accuracy by about 20% against using the simplified bare steel beam model. Adopting refined BRB stiffness computed from incorporating finite‐element gusset stiffness only improves the overall prediction accuracy by 0.9%. Considering the BRB dynamic loading test results for analytical BRB strength reduces the error by 1.9%. For the VD frame, incorporating the brace and VD stiffness could improve the overall prediction accuracy by about 15%. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
Braced frames are one of the most economical and efficient seismic resisting systems yet few full‐scale tests exist. A recent research project, funded by the National Science Foundation (NSF), seeks to fill this gap by developing high‐resolution data of improved seismic resisting braced frame systems. As part of this study, three full‐scale, two‐story concentrically braced frames in the multi‐story X‐braced configuration were tested. The experiments examined all levels of system performance, up to and including fracture of multiple braces in the frame. Although the past research suggests very limited ductility of SCBFs with HSS rectangular tubes for braces recent one‐story tests with improved gusset plate designs suggest otherwise. The frame designs used AISC SCBF standards and two of these frames designs also employed new concepts developed for gusset plate connection design. Two specimens employed HSS rectangular tubes for bracing, and the third specimen had wide flange braces. Two specimens had rectangular gusset plates and the third had tapered gusset plates. The HSS tubes achieved multiple cycles at maximum story drift ratios greater than 2% before brace fracture with the improved connection design methods. Frames with wide flange braces achieved multiple cycles at maximum story drift greater than 2.5% before brace fracture. Inelastic deformation was distributed between the two stories with the multi‐story X‐brace configuration and top story loading. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
Given their excellent self‐centering and energy‐dissipating capabilities, superelastic shape memory alloys (SMAs) become an emerging structural material in the field of earthquake engineering. This paper presents experimental and numerical studies on a scaled self‐centering steel frame with novel SMA braces (SMAB), which utilize superelastic Ni–Ti wires. The braces were fabricated and cyclically characterized before their installation in a two‐story one‐bay steel frame. The equivalent viscous damping ratio and ‘post‐yield’ stiffness ratio of the tested braces are around 5% and 0.15, respectively. In particular, the frame was seismically designed with nearly all pin connections, including the pinned column bases. To assess the seismic performance of the SMA braced frame (SMABF), a series of shake table tests were conducted, in which the SMABF was subjected to ground motions with incremental seismic intensity levels. No repair or replacement of structural members was performed during the entire series of tests. Experimental results showed that the SMAB could withstand several strong earthquakes with very limited capacity degradation. Thanks to the self‐centering capacity and pin‐connection design, the steel frame was subjected to limited damage and zero residual deformation even if the peak interstory drift ratio exceeded 2%. Good agreement was found between the experimental results and numerical simulations. The current study validates the prospect of using SMAB as a standalone seismic‐resisting component in critical building structures when high seismic performance or earthquake resilience is desirable under moderate and strong earthquakes. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
This paper investigates the implications of designing for uniform hazard versus uniform risk for light‐frame wood residential construction subjected to earthquakes in the United States. Using simple structural models of one‐story residences with typical lateral force‐resisting systems (shear walls) found in buildings in western, eastern and central regions of the United States as illustrations, the seismic demands are determined using nonlinear dynamic time‐history analyses, whereas the collapse capacities are determined using incremental dynamic analyses. The probabilities of collapse, conditioned on the occurrence of the maximum considered earthquakes and design earthquakes stipulated in ASCE Standard 7‐05, and the collapse margins of these typical residential structures are compared for typical construction practices in different regions in the United States. The calculated collapse inter‐story drifts are compared with the limits stipulated in FEMA 356/ASCE Standard 41‐06 and observed in the recent experimental testing. The results of this study provide insights into residential building risk assessment and the relation between building seismic performance implied by the current earthquake‐resistant design and construction practices and performance levels in performance‐based engineering of light‐frame wood construction being considered by the SEI/ASCE committee on reliability‐based design of wood structures. Further code developments are necessary to achieve the goal of uniform risk in earthquake‐resistant residential construction. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Collapse resistance of high‐rise buildings has become a research focus because of the frequent occurrence of strong earthquakes and terrorist attacks in recent years. Research development has demonstrated that numerical simulation is becoming one of the most powerful tools for collapse analysis in addition to the conventional laboratory model tests and post‐earthquake investigations. In this paper, a finite element method based numerical model encompassing fiber‐beam element model, multilayer shell model, and elemental deactivation technique is proposed to predict the collapse process of high‐rise buildings subjected to extreme earthquake. The potential collapse processes are simulated for a simple 10‐story RC frame and two existing RC high‐rise buildings of 18‐story and 20‐story frame–core tube systems. The influences of different failure criteria used are discussed in some detail. The analysis results indicate that the proposed numerical model is capable of simulating the collapse process of existing high‐rise buildings by identifying potentially weak components of the structure that may induce collapse. The study outcome will be beneficial to aid further development of optimal design philosophy. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
The design and detailing of gusset plate connections greatly influence the seismic performance of a special concentrically braced frame (SCBF). Recently, a balanced design approach has been proposed in order to develop significant inelastic deformation from multiple yield mechanisms and to delay the failure of connections of SCBF system. Although extensive studies have been conducted on the corner gusset plate connections of SCBFs, research on the detailing of mid‐span beam gusset plates is rather limited. This study aims at investigating the required free length for the detailing of the mid‐span gusset plates with different brace slenderness ratios. A nonlinear finite element analysis has been conducted for a braced frame with 4 different values of linear clearance in the mid‐span gusset plates and 2 values of brace slenderness ratios. In all simulation models, the corner gusset plates have been designed using balanced design approach and detailed using an elliptical clearance of 8 times the gusset plate thickness. An experimental study has also been conducted on 2 gusset plate sub‐assemblages having similar brace slenderness ratio but with 2 different values of linear clearance in the middle gusset plates. The lateral drift capacity corresponding to the brace fracture and the level of damage are found to be dependent on the detailing of the gusset plates. Based on the results of numerical and experimental studies, the required free length has been recommended for the detailing of middle gusset plates of SCBFs of different brace slenderness ratios.  相似文献   

16.
An analytical and experimental study has been conducted to evaluate the seismic performance of a three‐story suspended zipper steel frame. The frame was concentrically braced and had zipper struts to transfer the unbalanced forces induced on the beams due to the buckling of the lower‐story braces. The experimental study was conducted with the hybrid test technique, in which only the bottom‐story braces of the three‐story frame were physically tested, while the behavior of the rest of the frame was modeled using a general structural analysis software. The paper discusses issues pertinent to the calibration of the computer model for the analytical substructure as well as for the entire frame, including the selection of an appropriate damping matrix, and the modeling of the buckling behavior of the braces and bracing connections. The analytical model of the entire frame was validated with the hybrid tests and was able to accurately capture the material and geometric nonlinearities that developed when the braces yielded and buckled. This study has demonstrated the usefulness of hybrid testing in improving analytical models and modeling assumptions and providing information that cannot be obtained from an analytical study alone. The results have shown that the suspended zipper frame can distribute the brace nonlinearity over the first two stories as intended in the design and will not have catastrophic failure under the design‐level earthquakes considered in this study, despite the significant inelastic deformations. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
This paper presents shake‐table tests conducted on a two‐fifths‐scale reinforced concrete frame representing a conventional construction design under current building code provisions in the Mediterranean area. The structure was subjected to a sequence of dynamic tests including free vibrations and four seismic simulations in which a historical ground motion record was scaled to levels of increasing intensity until collapse. Each seismic simulation was associated with a different level of seismic hazard, representing very frequent, frequent, rare and very rare earthquakes. The structure remained basically undamaged and within the inter‐story drift limits of the ‘immediate occupancy’ performance level for the very frequent and frequent earthquakes. For the rare earthquake, the specimen sustained significant damage with chord rotations of up to 28% of its ultimate capacity and approached the upper bound limit of inter‐story drift associated with ‘life safety’. The specimen collapsed at the beginning of the ‘very rare’ seismic simulation. Besides summarizing the experimental program, this paper evaluates the damage quantitatively at the global and local levels in terms of chord rotation and other damage indexes, together with the energy dissipation demands for each level of seismic hazard. Further, the ratios of column‐to‐beam moment capacity recommended by Eurocode 8 and ACI‐318 to guarantee the formation of a strong column‐weak beam mechanism are examined. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
This study presents a seismic fragility analysis of low‐rise masonry in‐filled (MI) reinforced concrete (RC) buildings using a proposed coefficient‐based spectral acceleration method. The coefficient‐based method, without requiring any complicated finite element analysis, is a simplified procedure for assessing the spectral acceleration demand (or capacity) of buildings subjected to earthquakes. This paper begins with a calibration of the proposed coefficient‐based method for low‐rise MI RC buildings using published experimental results obtained from shaking table tests. Spectral acceleration‐based fragility curves for low‐rise MI RC buildings under various inter‐story drift limits are then constructed using the calibrated coefficient‐based method. A comparison of the experimental and estimated results indicates that the simplified coefficient‐based method can provide good approximations of the spectral accelerations at peak loads of low‐rise MI RC buildings, if a proper set of drift‐related factors and initial fundamental periods of structures are used. Moreover, the fragility curves constructed using the coefficient‐based method can provide a satisfactory vulnerability evaluation for low‐rise MI RC buildings under a given performance level. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
Dynamic finite element analyses of a four‐story steel building frame modeled as a fine mesh of solid elements are performed using E‐Simulator, which is a parallel finite element analysis software package for precisely simulating collapse behaviors of civil and building structures. E‐Simulator is under development at the National Research Institute for Earth Science and Disaster Prevention (NIED), Japan. A full‐scale shake‐table test for a four‐story frame was conducted using E‐Defense at NIED, which is the largest shaking table in the world. A mesh of the entire structure of a four‐story frame with approximately 19 million degrees of freedom is constructed using solid elements. The density of the mesh is determined by referring to the results of elastic–plastic buckling analyses of a column of the frame using meshes of different densities. Therefore, the analysis model of the frame is well verified. Seismic response analyses under 60, 100, and 115% excitations of the JR Takatori record of the 1995 Hyogoken‐Nanbu earthquake are performed. Note that the simulation does not reproduce the collapse under the 100% excitation of the Takatori record in the E‐Defense test. Therefore, simulations for the 115% case are also performed. The results obtained by E‐Simulator are compared with those obtained by the E‐Defense full‐scale test in order to validate the results obtained by E‐Simulator. The shear forces and interstory drift angles of the first story obtained by the simulation and the test are in good agreement. Both the response of the entire frame and the local deformation as a result of elastic–plastic buckling are simulated simultaneously using E‐Simulator. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
This paper presents the seismic behaviour of a concentrically braced frame system with self‐centring capability, in which a special type of bracing element termed reusable hysteretic damping brace (RHDB) is used. The RHDB is a passive energy dissipation device with its core energy‐dissipating component made of superelastic Nitinol wires. Compared with conventional bracing in steel structures, RHDB has a few prominent performance characteristics: damage free under frequent and design basis earthquakes in earthquake prone areas; minimal residual drifts due to the self‐centring capability of RHDB frame; and ability to survive several strong earthquakes without the need for repair or replacement. This paper also includes a brief discussion of the RHDB's mechanical configuration and analytical model for RHDB. The seismic performance study of RHDB frame was carried out through a non‐linear time history analysis of 3‐storey and 6‐storey RHDB frame buildings subjected to two suites of 20 earthquake ground motions. The analysis results were compared with buckling‐restrained brace (BRB) frames. This study shows that RHDB frame has a potential to outperform BRB frames by eliminating the residual drift problem. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   