State-of-the-art analytical techniques are capable of detecting contamination In the part per billion (ppb) range or lower. At these levels, a truly representative ground water sample Is essential to precisely evaluate ground water quality. The design specifications of a ground water monitoring system are critical in ensuring the collection of representative samples, particularly throughout the long-term monitoring period.
The potential interfaces from commonly used synthetic well casings require a thorough assessment of site, hydrogeology and the geochemical properties of ground water. Once designed, the monitoring system must be installed following guidelines that ensure adequate seals to prevent contaminant migration during the installation process or at some time in the future. Additionally, maintaining the system so the wells are in hydraulic connection with the monitored zone as well as periodically Inspecting the physical integrity of the system can prolong the usefulness of the wells for ground water quality. When ground water quality data become suspect due to potential interferences from existing monitoring wells, an appropriate abandonment technique must be employed to adequately remove or destroy the well while completely sealing the borehole.
The results of an inspection of a monitoring system comprised of six 4-inch diameter PVC monitoring wells at a hazardous well facility Indicated that the wells were improperly installed and in some cases provided a pathway for contamination. Subsequent down hole television inspections confirmed inaccuracies between construction logs and the existing system as well as identified defects in casing materials. An abandonment program was designed which destroyed the well casings in place while simultaneously providing a competent seal of the re-drilled borehole.  相似文献   

2.
Pitrak M  Mares S  Kobr M 《Ground water》2007,45(1):89-92
Borehole dilution techniques use repeated fluid column profiling after establishment of an initial uniform condition to monitor the rate at which ambient ground water moves into a borehole. Application of the dilution technique in a monitoring well makes it possible to estimate the horizontal Darcy flow velocity of ground water in the aquifer surrounding the borehole. Previous investigators have demonstrated the technique using either relatively concentrated saline solutions or deionized water to produce a fluid column with properties distinctly different from those of local ground water. We present a new dilution technique using the food color Brilliant Blue FCF (Euro code E-133) to mark the fluid column and using a specially constructed photometric sensor to characterize the dilution of this dye over time. The effective application of this technique is documented by two practical examples.  相似文献   

3.
A field lest to evaluate the applicability of an oxygon-releasing compound (ORC) to the rernediation of ground water contaminated with benzone and toluene was conducted in the Borden Aquifer in Ontario. Canada. Benzene and toluene were injected as organic substrates to represent BTEX compounds, bromide was used as a tracer, and nitrate was added to avoid nitrate-limited conditions.
The fate of the solutes was monitored along four lines of monitoring points and wells. Two lines studied the behavior of the solutes upgradient and downgradient of two large-diameter well screens filled with briquets containing ORC and briquets without ORC. One line was used to study the solute behavior upgradient and downgradient of columns of ORC powder placed directly in the saturated zone. The remaining line was a control.
The results indicate that ORC in both briquet and powder form can release significant amounts of oxygen to conlaminated ground water passing by it. In the formulation used in this work, oxygen release persisted for at least 10 weeks. Furthemiore, the study indicates that the enhancement of the available dissolved oxygen content of at least 4 mg/L each of the ground water by ORC can support biodegradation of benzene and toluene dissolved in ground water. Such concentrations are typical of those encountered at sites contaminated with petroleum hydrocarbons; therefore, these results suggest that there is promise for ORC to enhance in situ biodegradation of BTKX contaminants at such sites using passive (nonpumping) systems to contact the contaminated ground water with the oxygen source.  相似文献   

4.
Boreholes drilled through contaminated zones in fractured rock create the potential for vertical movement of contaminated ground water between fractures. The usual assumption is that purging eliminates cross contamination; however, the results of a field study conducted in a trichloroethylene (TCE) plume in fractured sandstone with a mean matrix porosity of 13% demonstrates that matrix-diffusion effects can be strong and persistent. A deep borehole was drilled to 110 m below ground surface (mbgs) near a shallow bedrock well containing high TCE concentrations. The borehole was cored continuously to collect closely spaced samples of rock for analysis of TCE concentrations. Geophysical logging and flowmetering were conducted in the open borehole, and a removable multilevel monitoring system was installed to provide hydraulic-head and ground water samples from discrete fracture zones. The borehole was later reamed to complete a well screened from 89 to 100 mbgs; persistent TCE concentrations at this depth ranged from 2100 to 33,000 microg/L. Rock-core analyses, combined with the other types of borehole information, show that nearly all of this deep contamination was due to the lingering effects of the downward flow of dissolved TCE from shallower depths during the few days of open-hole conditions that existed prior to installation of the multilevel system. This study demonstrates that transfer of contaminant mass to the matrix by diffusion can cause severe cross contamination effects in sedimentary rocks, but these effects generally are not identified from information normally obtained in fractured-rock investigations, resulting in potential misinterpretation of site conditions.  相似文献   

5.
Major challenges exist in delineating bedrock fracture zones because these cause abrupt changes in geological and hydrogeological properties over small distances. Borehole observations cannot sufficiently capture heterogeneity in these systems. Geophysical techniques offer the potential to image properties and processes in between boreholes. We used three‐dimensional cross borehole electrical resistivity tomography (ERT) in a 9 m (diameter) × 15 m well field to capture high‐resolution flow and transport processes in a fractured mudstone contaminated by chlorinated solvents, primarily trichloroethylene. Conductive (sodium bromide) and resistive (deionized water) injections were monitored in seven boreholes. Electrode arrays with isolation packers and fluid sampling ports were designed to enable acquisition of ERT measurements during pulsed tracer injections. Fracture zone locations and hydraulic pathways inferred from hydraulic head drawdown data were compared with electrical conductivity distributions from ERT measurements. Static ERT imaging has limited resolution to decipher individual fractures; however, these images showed alternating conductive and resistive zones, consistent with alternating laminated and massive mudstone units at the site. Tracer evolution and migration was clearly revealed in time‐lapse ERT images and supported by in situ borehole vertical apparent conductivity profiles collected during the pulsed tracer test. While water samples provided important local information at the extraction borehole, ERT delineated tracer migration over spatial scales capturing the primary hydrogeological heterogeneity controlling flow and transport. The fate of these tracer injections at this scale could not have been quantified using borehole logging and/or borehole sampling methods alone.  相似文献   

6.
Cautions and Suggestions for Geochemical Sampling in Fractured Rock   总被引:2,自引:0,他引:2  
Collecting water samples for geochemical analyses in open bedrock boreholes or in discrete intervals of boreholes intersected by multiple fractures is likely to yield ambiguous results for ground water chemistry because of the variability in the transmissivity, storativity, and hydraulic head of fractures intersecting the borehole. Interpreting chemical analyses of water samples collected in bedrock boreholes requires an understanding of the hydraulic conditions in the borehole under the ambient flow regime in the aquifer as well as during sampling. Pumping in open boreholes, regardless of the pumping rate and the location of the pump intake, first draws water from the borehole and then from fractures intersecting the borehole. The time at which the volumetric rate of water entering the borehole from fractures is approximately equal to the pumping rate can be identified by monitoring the logarithm of drawdown in the borehole as a function of the logarithm of time. Mixing of water entering the borehole from fractures with water in the borehole must be considered in estimating the time at which the pump discharge is representative of aquifer water. In boreholes intersected by multiple fractures, after the contribution from the borehole volume has diminished, the contribution of fractures to the pump discharge will be weighted according to their transmissivity, regardless of the location of the pump intake. This results in a flux-averaged concentration in the pump discharge that is biased by the chemical signature of those fractures with the highest transmissivity. Under conditions where the hydraulic head of fractures varies over the length of the borehole, open boreholes will be subject to ambient flow in the water column in the borehole. In some instances, the magnitude of the ambient flow may be similar to the designated pumping rate for collecting water samples for geochemical analyses. Under such conditions, the contributions to the pump discharge from individual fractures will be a function not only of the transmissivity of the fractures, but also of the distribution of hydraulic head in fractures intersecting the borehole. To reduce or eliminate the deleterious effects of conducting geochemical sampling in open boreholes, a straddle-packer apparatus that isolates a single fracture or a series of closely spaced fractures is recommended. It is also recommended that open boreholes be permanently outfitted with borehole packers or borehole liners in instances where maintaining the hydraulic and chemical stratification in the aquifer is of importance. In a field example, a comparison of results from sampling in an open borehole and in discrete intervals of the same borehole showed dramatic differences in the concentrations of chemical constituents in the water samples, even though chemical field parameters stabilized prior to both open borehole and discrete interval sampling.  相似文献   

7.
Ground water flow in karst terranes generally occurs in the solution channels of carbonate aquifers. A hydrogeologist may utilize borehole geophysical methods to identify these solution channels in aquifers. Two specific methods that are applicable in karst terrains are:
1. Natural gamma ray logging
2. Borehole caliper logging.
Gamma ray logging can detect the presence of inter-bedded strata in the main limestone unit, such as shale, which emit high levels of gamma radiation. Gamma ray logging can also detect clay deposits in solution channels that may act to restrict the flow of ground water. The areal extent of these rock strata or clay-filled solution channels can be determined when gamma ray logs are conducted at several borehole locations across the site of investigation.
Borehole caliper logging can be employed to determine the presences of solution channels within the aquifer when penetrated by a borehole. In addition, since shale layers and clay filling are less resistant than the surrounding limestone, the caliper log may detect both the presence and the thickness of shale or clay layers in the aquifer.
Gamma ray logs can be used in conjunction with caliper logs to provide data on the stratigraphic location and thickness of solution channels and clay and shale layers within a limestone aquifer. This information is valuable to the hydrogeologist performing investigations at sites located in limestone terranes because ground water flow preferentially occurs along solution channels.  相似文献   

8.
The Effect of Three Drilling Fluids on Ground Water Sample Chemistry   总被引:1,自引:0,他引:1  
Three monitoring wells were installed in borings that were constructed using water-based drilling fluids containing either (1) guar bean, (2) guar bean with breakdown additive, or (3) bentonite. These fluids were selected to observe their effect on the chemistry of subsequent water samples collected from the wells. The wells were installed to depths of 66 feet, 100.5 feet and 103 feet, respectively, in fine-to-medium sand and gravel outwash deposits near Antigo, Wisconsin. Drilling fluids were necessary to maintain an open borehole during well construction through strata containing cobbles and boulders.
The bentonite and guar drilling fluids caused temporarily elevated concentrations of chemical oxygen demand (COD) in ground water samples collected from the monitoring wells. Using standard development, purging and sampling procedures, elevated COD concentrations persisted for about 50 days for the well bored with the guar-with-additive fluid, 140 days for the bentonite well and 320 days for the guar well. Unfiltered ground water samples for all wells had greater concentrations of COD than samples filtered through a 0.45 micron filter. Sulfate concentrations also decreased with time in the guar-with-additive well and bentonite well, but not in the guar well.
The elevated COD concentrations are attributed to the large concentrations of oxidizable carbon present in the guar bean drilling fluid and in the organic polymers present in the bentonite drilling fluid. Well development and purging procedures, including borehole flushing, surging, bailing and/or chemically induced viscosity breakdown of the guar mud decreased the time before background conditions were achieved. Future research should evaluate the physical and geochemical interaction of different drilling fluid compositions with a variety of geologic matrices and drilling, well development and well purging techniques.  相似文献   

9.
Two borehole geophysical methods—electromagnetic induction and natural gamma radiation logs—were used to vertically delineate landfill leachate plumes in a glacial aquifer. Geophysical logs of monitoring wells near two land-fills in a glacial aquifer in west-central Vermont show that borehole geophysical methods can aid in interpretation of geologic logs and placement of monitoring well screens to sample landfill leachate plumes.
Zones of high electrical conductance were delineated from the electromagnetic log in wells near two landfills. Some of these zones were found to correlate with silt and clay units on the basis of drilling and gamma logs. Monitoring wells were screened specifically in zones of high electrical conductivity that did not correlate to a silt or clay unit. Zones of high electrical conductivity that did not correlate to a silt or clay unit were caused by the presence of ground water with a high specific conductance, generally from 1000 to 2370 μS/cm (microsiemens per centimeter at 25 degrees Celsius). Ambient ground water in the study area has a specific conductance of approximately 200 to 400 μS/cm. Landfill leachate plumes were found to be approximately 5 to 20 feet thick and to be near the water table surface.  相似文献   

10.
The recognition and assurance of the quality of ground water monitoring data are crucial to the correct assessment of the magnitude and extent of a ground water contamination problem. This article addresses an approach being developed to systematically evaluate the quality of a given set of ground water monitoring data collected during site investigation/ remedial action efforts. The system consists of a checklist of criteria, grouped into four major categories, which can be applied to laboratory or field measurements.
The first category, basis of measurement, considers whether the appropriate sampling, boring and/or analytical methods were chosen to obtain the measurement and the limitations of each method. Secondly, application of the method is assessed. This includes examination of the extent to which procedures were correctly performed, the use of quality control measures and calibration, and possible sources of error in the measurements. Third, evaluation of applied statistical methods is made, with consideration given to which statistics are meaningful in a given context and whether measurements are reproducible. The final category, corroborative information, considers whether independent data or other information are available that add credibility to the values measured.
In this approach, a "high quality" data value is defined as one in which accuracy is supported by meeting the preceding criteria. When accompanied by precision information, high quality data allow for defensible assessments and actions. This evaluation system is useful in developing monitoring programs and in guiding documentation of field and laboratory methods during data collection. It relies heavily on experienced judgment and can be catalyst for the beneficial exchange of knowledge and ideas among ground water professionals.  相似文献   

11.
An upsurge in oil- and gas-well drilling in northwestern Pennsylvania and western New York has been accompanied by several incidents of contamination of ground water by methane. Determining which well is causing the contamination is extremely difficult if more than one gas or oil well is present in the area.
The fact that the solubility of methane decreases as the pressure on ground water decreases provides a quantitative basis for monitoring changes in the amount of methane in the ground water. Quantitative measurements of the volume of methane given off by ground water pumped from a well as the water enters atmospheric pressure permit detection of temporal changes in the gas content which are too subtle to be detected visually. These gas volume changes may, in some cases, be correlated with variations in the pressure of methane in the annulus of nearby individual gas/oil wells and thus may provide a means of pinpointing the gas/oil well that is causing the methane contamination.
The basic principle of the gas-volume monitoring apparatus (GVMA) described in this paper is that as a measured amount of ground water enters atmospheric pressure the gas which comes out of solution is trapped and measured. The GVMA can be constructed of materials costing less than $100 and requires no special skills to assemble or operate. In a recent study conducted in a western New York village, four homeowners were able to collect quantitative gas-volume data from their household water wells daily in about one-half hour. Unlike laboratory analyses for dissolved methane, there is no cost involved in monitoring with the GVMA beyond the initial instrument cost and operator time. Another advantage is that the data are available immediately.  相似文献   

12.
利用钻孔雷达探测地下含水裂缝   总被引:4,自引:4,他引:0       下载免费PDF全文
钻孔雷达是地质雷达的一种特殊模式.和通常的地质雷达比起来,它有好几个显著的特点.比如,利用钻孔接近地下的某个区域,天线可以相对接近所要测量的地质异常体或目标,从而导致在较深的范围对目标的精确测量.实验场地位于北京西部的一个石灰岩的小山上.该处有一组钻孔,并被大量的裂缝所切割.在这些钻孔中,我们进行了单孔反射测量和跨孔测量.测量的数据经过处理和解释表明,在该场地雷达的径向探测范围可达30米,地下裂缝的分布可以形成清晰的图像.我们可以看到很多裂缝,它们距钻孔的距离及倾角都可以确定下来.在有些情况下,确定裂缝分布的方位是可能的.  相似文献   

13.
Electrical Leak Detection System for Landfill Liners: A Case History   总被引:9,自引:0,他引:9  
As landfill specifications become more stringent in the United Kingdom, the development of increasingly sophisticated monitoring methods is necessary to meet environmental protection goals. This case history describes the development of a 2-million-cubic-meter-capacity landfill located in a sandstone quarry and 1 km from a public water supply borehole, where the sensitivity of the site to ground water contamination and the proximity to a public water supply borehole are particular issues.
The landfill design incorporated a more sensitive environmental monitoring system, using a geophysical technique. The monitoring system comprises a permanent grid of electrodes installed beneath the landfill, connected by multicore cable to a computer-controlled earth resistance meter and switching unit in the site weighbridge. It was designed to detect holes in the landfill liner prior to and after covering with waste and to monitor the migration of contaminants beneath the landfill before they reach the perimeter observation boreholes, should leakage occur.
Such monitoring can enable the integrity of the landfill to be routinely reviewed; holes can be repaired if they are readily accessible and, if not, monitoring provides an early warning to enable the implementation of any additional monitoring or corrective action, based on the environmental risk posed by the site.
The system was first used as a quality assurance test once the landfill liner, which covered an area of 3 hectares, was installed. The system proved sensitive, detecting a hole consisting of two narrow knife cuts. Such sensitivity allows a high degree of confidence to be placed upon the integrity of the liner resulting in a significant contribution to public reassurance. The landfill is now operational, and monitoring using the geophysical system will be undertaken on a monthly basis for the first year, with the frequency of monitoring reviewed thereafter.  相似文献   

14.
A shallow seismic refraction survey was conducted as part of a geologic and hydrologic investigation of an area adjacent to a proposed coal strip mine in southeastern Illinois. Data obtained from the survey were used to estimate the thickness and geometry of litho-logic units within approximately 40 feet of the surface in unconsolidated material overlying bedrock. Data from a nearby ground water monitoring well and several shallow geologic cores obtained in the survey area indicated the presence of a silt-clay unit roughly 10 feet beneath the surface. This unit strongly inhibits the vertical movement of ground water, resulting in a perched water table.
The refraction survey revealed that the morphology of the top of this silt-clay layer is dominated by a narrow, sinuous channel criss-crossing the survey region with an overall downward trend in elevation from the mine site to a small creek roughly 0.25 miles away. Detailed knowledge of the location of this channel was used to identify optimal sites for shallow ground water monitoring stations. The method proved to be a relatively rapid and cost-efficient means of obtaining detailed information concerning the thickness and geometry of the near-surface unconsolidated materials.  相似文献   

15.
发展钻孔应变观测的战略构想   总被引:13,自引:2,他引:11  
钻孔应变观测正在成为一种与测震和GPS相提并论的地壳形变观测。曾经处于领先地位的我国钻孔应力一应变观测的发展需要回顾历史,面对现实,借鉴国外,放眼长远。建立比测基地、实验场和完善国家前兆监测网,三位一体,应该成为发展我国钻孔应变观测的基本方针。  相似文献   

16.
The reliability of filter pack and annular seal emplacements, and the degree of integrity of installed seals, are two of the most important factors to be considered when both installing and later utilizing ground water monitoring wells.
Numerous, and often costly, problems of using existing methods of installing filter packs and annular seals during the construction of ground water monitoring wells have led to the development of a technique of installing these monitoring well components using a dry injection system.
The dry injection system has been used to construct monitoring wells in extremely complex overburden/bedrock environments with a variety of drilling techniques. The system has shown that a high degree of reliability in the, construction of monitoring wells and greater confidence in obtaining representative ground water samples can be achieved over existing methods of filter pack and annular seal emplacement. The system has also been more cost effective than existing methods, especially for deep boreholes and multilevel monitoring system installations.  相似文献   

17.
Efforts to sample representative, undisturbed distributions of uranium in ground water beneath the Fernald Environmemal Management Project (FEMP) prompted the application of a novel technique that is less invasive in the monitoring well. Recent studies (Kearl et al. 1992; Barcelona et al. 1994) indicate that representative samples can and should be collected without prior well volume exchange purging or borehole evacuation. Field experiments conducted at the FMMP demonstrate that under specific sampling conditions in a welldefined hydrogeologic system, representative ground water samples for a monitoring program can be obtained without removing the conventional three well volumes from the well. The assumption is made that indicator parameter equilibration may not be necessary to determine when to collect representative samples at the P'liMP. Preliminary results obtained from the field experiment suggest that this may be true. The technique employs low purge rates (< 1 L/min) with dedicated bladder pumps with inlets located in the screened interval of the well, while not disturbing the stagnant water column above the screened interval. If adopted, this technique, termed micro-purge low-flow sampling, will produce representative ground water samples, significantly reduce sampling costs, and minimize; waste water over the monitoring life cycle at the FEMP. This technique is well suited for sites that have been fully characterized and are undergoing long-term monitoring.  相似文献   

18.
This paper presents an empirical relationship of quantitatively linked electromagnetic (EM) borehole recordings of the total dissolved solids (TDS) in pore water in the Quaternary deposits of the Belgian coastal plain. First, the long normal (LN) logs are linked to EM logs, then the already developed relationships between LN resistivity measurements and the TDS values are rewritten for EM recordings. The main parameter in these equations is the formation factor, which is derived from ground water analyses and LN logs through Archie's law. The EM recording has several advantages compared to the LN logs. The EM analysis allows measuring in PVC-cased wells and is not hindered by the invasion zone around the well. Furthermore, it has a high vertical resolution. LN logs can be measured only once, after drilling a well; EM recordings can be repeated several times in monitoring wells, which allows the gathering of time-dependent data over a complete vertical cross section. Such data could be obtained with LN logs only in wells with screens over the full-depth interval, which causes a hydraulic short circuit. This short circuit can result in a large artificial flow through the well between different levels, resulting in a salinity profile, which is no longer representative for the studied site. Remediation against short circuiting is a reduction of the screened interval, which strongly reduces the gathered information. The application of the derived equations is one of setting up a monitoring network along the Belgian coast to monitor the trend in salinity levels and comparing present salinity levels with older LN recordings to investigate the salinity changes in the last 30 years. Deep wells already present in the Belgiancoastal plain can then be used to monitor both the fresh water head changes and the salt water evolution. The technique has also been used for parameter identification for which real concentration measurements were needed.  相似文献   

19.
An Overview of In Situ Air Sparging   总被引:3,自引:0,他引:3  
In situ air sparging (IAS) is becoming a widely used technology for remediating sites contaminated by volatile organic materials such as petroleum hydrocarbons. Published data indicate that the injection of air into subsurface water saturated areas coupled with soil vapor extraction (SVE) can increase removal rates in comparison to SVE alone for cases where hydrocarbons are distributed within the water saturated zone. However, the technology is still in its infancy and has not been subject to adequate research, nor have adequate monitoring methods been employed or even developed. Consequently, most IAS applications are designed, operated, and monitored based upon the experience of the individual practitioner.
The use of in situ air sparging poses risks not generally associated with most practiced remedial technologies: air injection can enhance the undesirable off-site migration of vapors and ground water contamination plumes. Migration of previously immobile liquid hydrocarbons can also be induced. Thus, there is an added incentive to fully understand this technology prior to application.
This overview of the current state of the practice of air sparging is a review of available published literature, consultation with practitioners, a range of unpublished data reports, as well as theoretical considerations. Potential strengths and weaknesses of the technology are discussed and recommendations for future investigations are given.  相似文献   

20.
The objective of most ground water quality monitoring programs is to obtain samples that are "representative" or that retain the physical and chemical properties of the ground water in an aquifer. Many factors can influence whether or not a particular sample is representative, but perhaps the most critical factor is the method or type of sampling device used to retrieve the sample.
The sampling equipment available today ranges from simple to highly sophisticated, and includes bailers, syringe devices, suction-lift pumps, gas-drive devices, bladder (Middelburg-type) pumps, gear-drive and helical rotor electric submersible pumps and gas-driven piston pumps. New devices are continually being developed for use in small-diameter wells in order to meet the needs of professionals engaged in implementing elaborate ground water monitoring programs.
In selecting a sampling device for a monitoring program, the professional must consider a number of details. Among the considerations are: the outside diameter of the device, the overall impact of the device on ground water sample integrity (including the materials from which the sampling device and associated equipment are made and the method by which the device delivers the sample), the capability of the device to purge the well of stagnant water, the rate and the ability to control the rate at which the sample is delivered, the depth limitations of the device, the ease of operating, cleaning and maintaining the device, the portability of the device and required accessory equipment, the reliability and durability of the device, and the initial and operational cost of the device and accessory equipment. Based on these considerations, each of the devices available for sampling ground water from small-diameter wells has its own unique set of advantages and disadvantages that make it suitable for sampling under specific sets of conditions. No one sampling device is applicable to all sampling situations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号