首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
本文针对钢板剪力墙结构自振周期缺乏研究的现状,将钢板剪力墙简化为Timoshenko梁,提出了考虑周边框架影响的钢板剪力墙等效抗剪刚度计算的方法,然后根据Southwell-Dunkerley理论,给出了钢板剪力墙结构基本自振周期的简化计算公式。然后,通过56个算例比较分析了本文公式计算结果与有限元计算结果发现:本文公式计算结果与有限元结果之比的平均值为1.015,标准差为0.049,说明本文公式具有足够的可靠性。接着,又对结构高度、均布质量、等效抗剪、抗弯刚度、钢板的高厚比、高宽比等参数进行了分析,分析结果表明:随着结构高度与均布质量开方的乘积增大,结构的基本自振周期增长;层数相同时,随着等效抗剪刚度、抗弯刚度的增大,周期有减小的趋势;层数相同时,随着钢板高厚比与高宽比乘积的增大,周期增长。  相似文献   

2.
This study consists of two parts. In this two‐part research, four two‐story narrow steel plate shear walls (SPSWs) were cyclically tested at the Taiwan National Center for Research on Earthquake Engineering in 2007. This paper, Part 1, proposes a capacity design method for the first‐story boundary column of the SPSW to ensure that the plastic hinges form at the column bottom ends when the SPSW develops the plastic mechanism. The design method was developed based on the superposition method considering the frame sway action and the panel force effects of the SPSW. Restrained steel plate shear wall (R‐SPSW) studied herein adopts pairs of the horizontal restrainers sandwiching over both sides of the infill panels and connected to the boundary columns. Analytical studies on four SPSW example designs using nonlinear finite element (FE) models and the simplified strip models confirm that the restrainers could also effectively reduce the column force demands and allow the infill panel to stretch more uniformly. In addition, the FE analytical studies verify the effectiveness of the proposed column capacity design method and the seismic design recommendations for the restrainer. This paper introduces the designs of the four narrow SPSW specimens, presenting the selections of the boundary beams and columns, the designs of the beam‐to‐column connections and the construction details of the restrainers. The experimental results, key observations and the design implications are reported in the companion paper. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
Coupled steel plate shear wall (C‐SPSW) consists of two or more steel plate shear walls interconnected by coupling beams at the floor levels. In this study, a six‐story C‐SPSW prototype building was designed. A 40% scale C‐SPSW specimen, which is representative of the bottom two‐and‐half‐story substructure of the prototype, was cyclically tested using Multi‐Axial Testing System at the National Center for Research on Earthquake Engineering in 2009. In addition to a constant vertical force representing the gravity load effects, cyclic increasing displacements and the corresponding overturning moments transmitted from the upper stories were computed online and simultaneously applied on the substructural specimen. This paper firstly introduces the designs of the prototype C‐SPSW and the test specimen. Then, the test results and the numerical simulation are discussed in detail. Test results confirm the effectiveness of the proposed column capacity design method, which aims at limiting the plastic hinge formation within the bottom quarter height of the bottom column. Test and analytical results suggest that the coupling beam rotational demands can be estimated as the design story drifts when the formation of desirable plastic mechanism of the C‐SPSW is expected. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
Design recommendations for steel plate shear wall (SPSW) systems have recently been introduced into seismic provisions for steel buildings. Response modification (R), overstrength (Ωo), and displacement amplification (Cd) factors for SPSW systems presented in design codes were based on professional experience and judgment. A numerical study has been undertaken to evaluate these factors for SPSW systems. Forty‐four unstiffened SPSW possessing different geometrical characteristics were designed based on the recommendations given in the AISC Seismic Provisions. Bay width, number of stories, story mass, and steel plate thickness were considered as the prime variables that influence the response. Twenty records were selected to include the variability in ground motion characteristics. In order to provide a detailed analysis of the post‐buckling response, three‐dimensional finite element analyses were conducted for the 44 structures subjected to the selected suite of earthquake records. For each structure and earthquake record, two analyses were conducted in which the first includes geometrical nonlinearities and the other includes both geometrical and material nonlinearities, resulting in a total of 1760 time history analyses. In this paper, the details of the design and analysis methodology are given. Based on the analysis results, response modification (R), overstrength (Ωo), and displacement amplification (Cd) factors for SPSW systems are evaluated. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
The seismic performance of composite steel plate shear walls (CSPSWs) that consist of a steel plate shear wall (SPSW) with reinforced concrete (RC) panels attached to one or both sides by means of bolts or connectors is experimentally studied. The shear wall is connected to the frame beams but not to the columns. This arrangement restrains the possible out-of-plane buckling of the thin-walled steel plate, thus significantly increasing the bearing capacity and ductility of the overall wall, and prevents the premature overall or local buckling failure of the frame columns. From a practical viewpoint, these solutions can provide open space in a floor as this type of composite shear walls with a relatively small aspect ratio can be placed parallel along a bay. In this study, four CSPSWs and one SPSW were tested and the results showed that both CSPSWs and SPSW possessed good ductility. For SPSW alone, the buckling appeared and resulted in a decrease of bearing capacity and energy dissipation capacity. In addition, welding stiffeners at corners were shown to be an effective way to increase the energy dissipation capacity of CSPSWs.  相似文献   

6.
Previous research has shown that self‐centering steel plate shear walls (SC‐SPSWs) are capable of achieving enhanced seismic performance at multiple hazard levels, including recentering following design‐level earthquakes. When modeling SC‐SPSWs numerically, these studies considered an idealized tension‐only steel plate shear wall (SPSW) web plate behavior. Research has shown that web plate behavior is more complex than predicted by the idealized model, and web plates can provide more strength, stiffness, and energy dissipation than predicted by the idealized model. The idealized model of web plate behavior is used widely in SPSW numerical models where the moment‐resisting boundary frame provides supplemental hysteretic damping and stiffness; however, in SC‐SPSWs, where the post‐tensioned boundary frame is designed to remain elastic during an earthquake, accounting for the more complex web plate behavior can have a significant impact on seismic performance estimates from numerical simulation. This paper presents different methods for modeling SC‐SPSWs. Responses from these models are compared with experimental results. A simple modification of the tension‐only model, referred to as the tension‐compression strip model, is shown to provide a reasonable approximation of SC‐SPSW behavior. Results from nonlinear response history analyses of SC‐SPSWs with the tension‐only and tension‐compression web plate models are compared to assess how the approximation of web plate behavior affects SC‐SPSW seismic performance. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
为了提高装配式剪力墙的抗震性能,提出并设计了一片暗柱内置H型钢装配式内藏钢桁架混凝土剪力墙及一片暗柱内置圆钢管装配式内藏钢桁架混凝土剪力墙,其中H型钢竖向连接采用顶底角钢复合连接,圆钢管竖向连接采用端板焊接.通过对试件进行低周反复加载试验,得到剪力墙试件的破坏模式、滞回曲线、承载力、延性、残余变形、刚度退化和耗能能力等...  相似文献   

8.
Cyclic loading tests were performed on three one‐storey steel frames and four three‐storey concrete‐filled tube (CFT) moment frames reinforced with a new type of earthquake‐resisting element consisting of a steel plate shear wall with vertical slits. In this shear wall system, the steel plate segments between the slits behave as a series of flexural links, which provide fairly ductile response without the need for heavy stiffening of the wall. The steel shear walls and the moment frames behaved in a ductile manner up to more than 4% drift without abrupt strength degradation or loss of axial resistance. Results of these tests and complementary analysis provide a basis for an equivalent brace model to be employed in commercially available frame analysis programs. Test and analytical results suggest that the horizontal force is carried by the bolts in the middle portion of the wall–frame connection, while the vertical forces coupled with the moment in the connection are resisted by the bolts in the edge portion of the connection, for which the friction bolts in the connection should be designed. When sufficient transverse stiffening is provided, full plastic strength and non‐degrading hysteretic behaviour can be achieved for this new type of shear wall. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

9.
The steel plate shear wall (SPSW) system is a robust option for earthquake resistance due to the strength, stiffness, ductility and energy dissipation that it provides. Although thin infill plates are efficient for resisting lateral loads, boundary frames that are proportioned based on capacity design requirements add significant structural weight that appears to be one of the factors limiting the use of the system in practice. An alternate configuration, the SPSW with coupling (SPSW‐WC), was explored recently as an option for increasing architectural flexibility while also improving overall system economy and seismic performance. The SPSW‐WC, which extensively employs flexural boundary frame contribution, has shown promise in analytical, numerical and experimental studies, but recent research on uncoupled SPSWs suggests that boundary frame contribution should not be considered for carrying seismic design shear. As a result, in the present study, boundary frame contribution in SPSWs was explored with detailed three‐dimensional finite element models, which were validated against large‐scale SPSW‐WC tests. Six‐story systems were considered, and the study matrix included single and double uncoupled SPSWs along with coupled SPSWs that had various degrees of coupling. Variations in design methodology were also explored. The modeling framework was employed to conduct static monotonic and cyclic pushover analyses and dynamic response history analysis. These analyses demonstrate the beneficial effect of coupling in SPSWs and illustrate the need to consider boundary frame contribution in design of coupled SPSWs. In addition, sharing design shear between the infill plate and the boundary frame is more generally shown to not be detrimental if this sharing is done in the design stage based on elastic analysis and the resulting boundary frame provides adequate secondary strength and stiffness following infill plate yielding. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

10.
The steel plate shear wall (SPSW) is an effective lateral force resisting system in which unstiffened steel infill plates are connected to the horizontal and vertical boundary elements (VBEs) on all sides of the plates. The boundary elements must be designed to resist the tension field force of the infill panels. When the VBEs are made from a steel box section, the flange of each box VBE connected with the infill panels can be pulled out‐of‐plane by significant panel forces, called pull‐out action. This study investigates capacity design methods for box VBEs in SPSWs. Simplified fixed beam and portal frame models aim to estimate the pull‐out responses of the flange of the box sections with and without infill concrete, respectively. In this study, cyclic tests of three full‐scale two‐story SPSWs using box VBEs with or without the infill concrete are conducted. Inelastic pushover analyses of the finite element models are conducted. The tests and analytical results confirm that the proposed design methods, which aimed to prevent the full yield of the flange under the pull‐out action, are applicable. Furthermore, the test and analytical results suggest that the initial yielding of the flange of box VBEs under the collective effects of the pull‐out action on the flange, the gravity load, and the sway action on the SPSW represents a local yielding. A strict prohibition of the initial yielding on the flange under the aforementioned collective effects is not recommended for pursuing a cost‐effective design. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

11.
钢框架-带缝钢板剪力墙结构受力性能分析   总被引:1,自引:0,他引:1  
本文对4种钢框架、6种带缝(两排)钢板剪力墙片(四周与构件无连接)和6种固接的钢框架-带缝钢板剪力墙结构在3种不同竖向荷载作用下的抗侧能力和往复荷载下的滞回性能进行了研究,并对比分析。结果表明:前两种结构的侧移刚度、抗侧能力相对较低,屈曲后刚度退化快;钢框架-带缝钢板剪力墙结构的侧移刚度、抗侧能力和耗能能力比前两种结构有明显的提高,说明钢框架与带缝钢板剪力墙片固接后工作协调性能良好。带缝钢板剪力墙片与钢框架-带缝钢板剪力墙结构的整体设计参数宽高比W/H,开缝设计参数开缝墙肢的高宽比h/b、宽厚比b/t、开缝墙肢与剪力墙的高宽比h/H对结构的抗侧能力和滞回性能有很大影响。W/H增大,结构的抗侧能力增强,滞回性能降低;h/b、b/t、h/H增大,结构的抗侧能力降低,滞回性能提高。  相似文献   

12.
为研究网格间距对网格剪力墙抗震性能的影响,对两个竖肢中心距不同的小剪跨比网格剪力墙进行了拟静力试验及有限元分析。结果表明:横肢中心距相同、竖肢中心距分别为200 mm及300 mm的网格剪力墙破坏模式不同,竖肢中心距为200 mm的网格剪力墙下部和墙底角部混凝土破坏,破坏模式为剪压破坏;竖肢中心距为300 mm的网格剪力墙沿对角线主斜裂缝错动并产生滑移,破坏模式为剪拉破坏。两个试件的极限位移角均在1/100左右,竖肢中心距为300 mm的网格剪力墙刚度和承载力略大。有限元模拟结果与试验吻合良好,验证了模拟方法的有效性。提出了适用于不同间距网格墙的等效厚度计算方法,网格剪力墙可等效为实体剪力墙计算刚度和承载力。  相似文献   

13.
钢管混凝土边框钢板剪力墙是一种新型抗震剪力墙,为了比较不同构造措施对该新型剪力墙抗震性能的影响,进行了3个剪跨比为1.5的钢管混凝土边框钢板剪力墙低周反复荷载试验。其中,试验模型1为墙体钢板与边框柱钢管焊接,试验模型2为墙体钢板与边框柱钢管螺栓连接,试验模型3为墙体钢板开孔并与边框柱钢管焊接。通过试验研究,比较了各剪力墙的破坏特征、滞回特性、承载力、刚度、延性以及耗能能力。结果表明:在墙体钢板与边框柱钢管的连接方式中,采用焊接或栓接对剪力墙的整体性能影响不大;与普通钢管混凝土边框钢板剪力墙相比,钢板开孔钢管混凝土边框钢板剪力墙在开孔率不大的情况下,其承载力、延性、刚度和耗能能力没有明显变化。  相似文献   

14.
This paper is the second part of a two‐part paper presenting the cyclic tests of four two‐story narrow steel plate shear walls (SPSWs). The first paper introduces the analytical studies and the specimen designs. This paper describes the test results. Some design implications including the capacity design for the first story column and the width‐to‐thickness ratio check for the beam web are discussed based on key observations from the tests. Test results confirm that the simplified strip model can accurately predict the inelastic responses of the specimens. Test results also confirm that the proposed capacity design method is effective in ensuring the plastic hinge formation at the bottom end of the first story column for SPSW with or without restrainers. Test results also show that the horizontal restrainers are effective in reducing the member forces in the boundary beam and column elements. Comparing the test results of the typical SPSW with those of the restrained SPSW (R‐SPSW) specimens, it is found that the R‐SPSW possesses an improved cyclic performance and reduced material weight. Analytical results predict the compressed column moments at the onset of the column plastic hinge formation well. The analytical hysteretic energy distribution in the first story column agrees very well with the observed inelastic actions developed in the four specimens. The detailed frame response analyses and the test results confirm that the assumptions made in developing the proposed column capacity design method are reasonable. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
钢板组合剪力墙在强震作用下受损严重,震损修复问题较为突出。现设计一片以方钢管作为边缘约束构件的竖波钢板组合剪力墙,在最大弹塑性层间位移角时的震损情况进行分析:竖波钢板组合剪力墙边缘约束方钢管刚度较大,与墙体不匹配,最终发生方钢管从地梁拔动的脆性破坏模式。对竖波钢板组合剪力墙进行震损修复,得到墙趾可更换竖波钢板组合剪力墙,然后进行拟静力试验。试验结果表明:(1)在震损后的竖波钢板组合剪力墙的墙趾处安装阻尼器,其抗震性能基本得到恢复。(2)修复后的竖波钢板组合剪力墙承载力较修复前降低了23%,但延性和耗能能力显著提升。(3)改变了竖波钢板组合剪力墙的破坏模式,由脆性破坏转化为延性破坏。借助有限元软件详细讨论了内嵌竖向波形钢板厚度和波角、轴压比、阻尼器腹板数量对修复后竖波钢板组合剪力墙抗剪承载力的影响,结果表明:改变内嵌竖向波形钢板厚度对试件抗剪承载力影响较大,而改变内嵌竖向波形钢板波角、轴压比和阻尼器腹板数量对试件抗剪承载力影响较小。结合有限元算例,提出修复后竖波钢板组合剪力墙抗剪承载力的计算公式,可为工程实际提供参考。  相似文献   

16.
半刚接框架-非加劲钢板墙体系抗震试验研究   总被引:1,自引:1,他引:0  
半刚接钢框架-内填非加劲薄钢板剪力墙结构是一种新型结构形式,它弥补了传统抗弯钢框架侧向刚度不足的缺点,为采用更加经济的半刚性节点提供了可能,目前国内外对该新型结构体系性能研究属刚起步阶段,因此对该结构体系的研究具有重要的理论和实际意义。文中对一榀两层单跨梁柱平齐端板连接半刚性框架-内填非加劲薄钢板剪力墙结构进行了低周往复循环加载拟静力试验,在试验中,试件破坏过程缓慢,钢板墙拉力带充分发育,试验得出的滞回环饱满,表明该新型结构体系具有优异的抗震性能,从而为今后对该新型结构体系做更深入的分析研究打下了良好基础。  相似文献   

17.
对一榀1/3比例的单跨两层梁柱腹板双角钢连接框架-非加劲薄钢板剪力墙结构进行了水平低周往复加载试验研究.从承载力指标、刚度指标、延性指标、消能指标、破坏顺序和破坏模态以及连接节点的受力变形性能对试件作出评价,探究节点刚度与墙体的相互影响效果.结果表明:试件具有较高水平承载力和初始抗侧刚度,试件延性良好.结构具有理想的屈...  相似文献   

18.
在大连国际会议中心核心筒墙体抗震设计中,采用了一种钢管混凝土叠合边框墙肢内藏钢板、连梁内藏钢桁架的组合双肢剪力墙。为研究其抗震性能,进行了1个1/7缩尺的这种新型组合双肢剪力墙模型的低周反复荷载试验,分析了其承载力、延性、刚度及其退化、滞回特性、耗能能力和破坏特征,重点研究了钢管混凝土叠合边框、墙肢内藏钢板、连梁内藏钢桁架之间的共同工作性能。研究表明:内藏钢板-钢桁架可显著提高钢管混凝土叠合边框双肢剪力墙的承载力和延性性能;钢管混凝土叠合边框可充分发挥其承载力高、不易开裂、延性好的优势。文中提出了该新型组合双肢剪力墙的承载力计算模型,计算结果与实测结果符合较好。  相似文献   

19.
针对半刚接钢框架-混凝土墙(PSRCW)结构中连接件易发生疲劳断裂的问题,利用形状记忆合金(SMA)制成连接件并将其应用到PSRCW结构中。对4个2层单跨PSRCW结构试件在水平低周往复荷载作用下的抗震性能进行了试验研究。根据试验现象分析了各试件的受力破坏过程,研究了连接件类型、尺寸和布置位置对各试件的滞回性能、耗能能力、强度、刚度、延性和变形恢复能力的影响。试验结果表明:基于SMA连接件的PSRCW结构整体性较好、耗能能力强、结构强度退化具有2个平台阶段、刚度退化较为缓慢、延性好和结构具有较强的变形恢复能力。同时,增大SMA连接件的直径可以提高结构的承载能力、初始刚度和延性;在框架梁柱与内填墙交界面间均布置SMA连接件时,结构整体性最好,强度退化缓慢,延性好。因此,将SMA连接件应用于PSRCW结构中,对于改善钢混组合结构的力学性能有一定的理论意义和实用价值。  相似文献   

20.
三层单排配筋剪力墙结构抗震性能试验研究   总被引:2,自引:0,他引:2  
为了对双排配筋剪力墙和单排配筋剪力墙的抗震性能进行对比研究,本文设计了1个1/3缩尺的三层混凝土剪力墙结构模型,模型的一侧墙体为双向双排配筋,另一侧墙体为双向单排配筋。对其进行了低周反复荷载下的抗震性能试验研究,分析了其承载力、延性、刚度及其退化过程、滞回特性、耗能能力和破坏特征。研究表明:在墙体的配筋率相同情况下,由于单排配筋墙体钢筋的间距相对于双排配筋墙体钢筋间距小,其首先约束混凝土裂缝的几率更大,其平面内的抗震性能优于双排配筋剪力墙;由于剪力墙的翼缘和腹板共同工作,单排配筋剪力墙平面外的性能也可满足多层剪力墙结构设计的要求。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号